| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.6 L+₹71,224.50 (3.25%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance L2 | |
| 3 | L3₹22.8 L+₹81,998.50 (3.74%)Rejected-Finance 88 197 B CHAMAN GANJ KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹23.9 L+₹1.9 L (8.77%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹55,600
Closing Date
4 Nov 2023, 6:00 pmClosed
GE (AF) UDHAMPUR
GE AF STN UDHAMPUR
REPAIR MAINTENANCE OF AVIATION LIGHTS / HANGER LIGHT / INDUSTRIAL SOCKETS / INDUSTRIAL SOCKETS PANEL WITH FLEXIBLE CABLE / THREE PHASE SUB MAIN WIRING / BUILDING EARTHING ETC AND CERTAIN REPAIR TO SOLAR WATER HEATER OF VARIOUS LOCATION OF 39 WING AIR
2023_MES_621671_1
GE/AFU-45/2023-24
Open Tender
Civil Works
Works
270 days
GE AF STN UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹55,600
Yes
29 Dec 2023
7 Oct 2023
6 Nov 2023
7 Oct 2023
4 Nov 2023
21 Oct 2023
12 Oct 2023 - 19 Oct 2023
Amount
S&F in repair of Integral LED aviation light luminaire in yellow die-cast aluminium alloy housing with red coloured polycarbonate dome including necessary electric connection with suitable size of PVC copper cable as per manufacture's requirement and building /tower height up to 30mtr complete all as specified and as directed by Engineer-in-Charge Make : Cat part No BGAV 302 LED of Bajaj or equivalent C&S/CG/Philips
S&F in repair Wiring for circuit 2 core 2.5 sqmm copper conductor PVC insulated PVC sheated as per is 694 up to date all including drawing through PVC Conduit making connection with LED Building security Light/ tower light / fitting up to height 30mtr etc complete all as specified and as directed by enginer in charge Note : Light fitting shall be conected by taping the two core cable with pvc/bakelite electrical connector. Connectors shall be installed/inseated /enclosed inside the conduit /box cost shall be deemed to be included in quoted rates Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
Taking down unserviceable hanger lights from the hight of approx up to 25 mts from ground level including electric connections and supply and fixing hangers lights 150W CRI 80, pf>0.90 complete spd with driver Energy saving environment friendly & robust /Highbay LED Luminanire with high high efficacy (150lm/W) IP 66/65 with toughened glass industrial applications,including necessary electric connection, remoing of wire net /mesh and refixing of wire mesh/net up to height 30mtr and making good condition complete all as specified and directed by Engr-in-charge. Make : CAT Part No TIP-320-150-57-SL-GL-NSG of crompton or its equavalent to wipro / philips / Havells/ HPL
M&L in repair Wiring for circuit 2 core 4.0 sqmm copper conductor PVC insulated PVC sheated as per is 694 up to date all including drawing through PVC Conduit making connection with LED Building security Light/ tower light / fitting up to height 30 mtr etc complete all as specified and as directed by enginer in charge . Note : Light fitting shall be conected by taping the two core cable with pvc/bakelite electrical connector. Connectors shall be installed/inseated /enclosed inside the conduit /box cost shall be deemed to be included in quoted rates
Solar water heater Descaling of solar Collectors plate connected to solar water heater of various capicty(by circulating desclaing solution/agent for 20-30 miniute),evacuated tube type,cleaning entire surface (dismaintiling of plates shal be carried out if requied including fixing fixing soldering requied)and cleaning of tank of capicity 100/200/300/400 LPD by solar descaling (such as mild acidic solution vinegaretc) solution/agent including drain ouy all Scales dust, dirt by pressure pip[e Cleaning& replacement of U/S drain plug along with all requied work such as welding,theriding etc all as specified and as directd
S&Fix in repairs Evacutated tube collector type for 100 ltrs solar water heater(MNRE approved) along with GI storage tank of suitable capicity on iron angle stand applying watre sealent around stand fastners including dismaintaling of old unserviceable solar water heater of any type complete as specified and directed.
S&Fin repairs Evacutated tube collector type 200 ltrs solar water heater(MNRE approved) along with GI storage tank of suitable capicity on iron angle stand applying watre sealent around stand fastners including dismaintaling of old unserviceable solar water heater of any type complete as specified and directed.
S&Fin repairs Evacutated tube collector type 300 ltrs solar water heater(MNRE approved) along with GI storage tank of suitable capicity on iron angle stand applying watre sealent around stand fastners including dismaintaling of old unserviceable solar water heater of any type complete as specified and directed.
Supply and replacement Solar water system flat plate collactor with heat exchanger (MNREapproved) type suitable plate size for existing plate complete all as specified and as directed.
Supply and fixing of in replacement of old unserviceable water tank of flate plate solar water heater/Evacuated tube solar water heater capicity 100/200/300/400 LPD along with all connecting items like nut,bolte gasket,soldering welding complete all as specified and as directed.ed.
Supply and fixing of in replacement of old unserviceable tube /Evacuated tube solar water heater capicity 100/200/300/400 LPD along with all connecting items like nut,bolt gasket,soldering welding complete all as specified and as directed.ed.
Labour and material for fixing only serviceable FPC solar plates retrived from 6,7,8 including all nuts washers suitable flexible rubber/silicone hose pipe welding etc including dismainteling of existing non functional FPC solar plate as directed by Engr in charge.
Labour and material for fixing only serviceable Solar heater tank retrived from 6,7,8 including all nuts washers suitable flexible rubber/silicone hose pipe welding etc including dismainteling of existing non functional FPC solar plate as directed by Engr in charge.
M&L for clading of insulated rubber(rockwool/mineral wool/fibre glass wool)as per fixed on site including one layer of aluminium sheet/flakes cover on outer/air vent of solar water heater GI pipe in a minimise any type of heat losses complete all as specified and as directed by engineer in charge.
Supply and repair unserviceable EPDM sheet including requied nut bolt and washer set at both end used for jointing two flate collector/at end of solar flat plate collector(Medium pressure flexible silicon/rubber hose suitable for hot water of suitable size along with tighting clips wherever requied instead of EPDM sheet) for arresting the leakage complete all as spcifeid and as directed.
S&F in repair of heating Heating Element 3000Watt alongwiith thermostat of suitable shape and size fitted in solar water tank any capicity conforming to ISI mark with ruber washers with clamps complete all as specified and as directd by Engr in charge
Suppply and fixing in repair Heating Element 2000Watt alongwiith thermostat of suitable shape and size fitted in solar water tank any capicity conforming to ISI mark with ruber washers with clamps complete all as specified and as directd by Engr in charge
S&F in repairs plug top 3 pin 15 Amp ISI marked complete all as specified and as directed.
Suppply and fixing in repair Stem type thermostate with switch/nob suitable for solar water heater all as specified and as directed
M&L for cross arms brasings supports clamps and back plates fabricatd from structural steel sections including nuts,bolts washers welding bending cold or hot drilling holes for bolts in any type shape or size as indicated or directed and provn of two coat systhic enamed part over a coat of red oxide primer complete primer all as specifed and as directed
S&F in repair of Bib taps 15 mm cast copper alloy with crutch or butterfly handle screwed down screwed down screwed for iron pipe or brass ferrule and fancey type including taking down complete all as specified and as directed.
S&F in repair of Bib taps 20 mm cast copper alloy with crutch or butterfly handle screwed down screwed down screwed for iron pipe or brass ferrule and fancey type including taking down complete all as specified and as directed.
Supply and replacement of GI tubing medium grade of size 25mm bore ISI marked galvanized with all fittings such as bends, elbows, tees, check nuts, unions nipples etc for cold water pipe line complete all as specified and as directed
All as per item No 23 here-in-before but 20mm bore.
S& F in repair Gun metal globe or gate valves 15 mm cast iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed.
S& F in repair Gun metal globe or gate valves 20mm cast iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed.
S& F in repair Gun metal globe or gate valves 25 mm cast iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repairs brass non-return valve 20/25 mm bore ISI marked screwed both ends and connecting to iron pipe complete all as specified and as directed.
M&L for dismantling old unserviceable tank in replacement with new Rotational moulded polyethylene water storage tanks of capacity 500 ltrs three layered (Cylindrical vertical with closed top) hoisted and fixed in position including ball cock brass of size 20mm dia with polythene ball and inlet, outlet including wash out with plug/over flow pipe and anti mosquito rose coupling at one end all as specified in SSR Pt-I complete all as specified and as directed .
M&L for dismantling old unserviceable tank in replacement with new Rotational moulded polyethylene water storage tanks of capacity 1000 ltrs three layered (Cylindrical vertical with closed top) hoisted and fixed in position including ball cock brass of size 20mm dia with polythene ball and inlet, outlet including wash out with plug/over flow pipe and anti mosquito rose coupling at one end all as specified in SSR Pt-I complete all as specified and as directed .
S&F in repair float valve 15/ 20 mm fixing of solar water tank complete all as specified and as directed
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of heavey duty PVC conduit drawn through PVC conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 6.00 sqmm main cable and one RM of 6.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Surface Conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
S&F switch piano, flush type, 5 amps single pole, one way complete all as specified and as directed.
S&F in repairs Recess mounting type LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 36 watt to 42 watt (cool white), minimum system lumen efficacy not less than 100 lumper watt, CRI not less than80, colour temperature not less than 6000 K, power factor not less than 0.95, LED driver IP protection IP 20, powder coated housing with ashthetic bottom frame, suitable for any type of ceiling system including connection with PVC insulated copper conductor complete all as specified.
Supply and fixing in reapir of Building security LED street light fitting 30 Watt 6500K pf >.90 efficency 100lp/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp fixing of wall,pole,building with impact and corrosion resistant including thermal management in multiple optics and suitable size clamp of security light complete with IP 65 protection complete all as specified and as directed.
Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade 20 mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion.
Supply and fixing of Earth continuity conductor or main 4 mm Galvanised iron wire fixed to wall on batten or recess or chases including or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. Complete all as specified and as directed
Supply and fix in repair of industrial metal socket and plug 16 Amp (2 Phase and earth ) 2 mod IP: 30 Protation 16 Amps MCB complete all as specified and as directed.
Supply and fix in repair of industrial metal socket and plug 32 Amp (2Phase and earth ) 2 mod IP: 30 Protation including 32 Amps MCB complete all as specified and as directed.
Supply and fix in repair of industrial metal socket and plug 32 Amp (3Phase and Netural& earth ) 4mod IP: 30 Protation including TPN MCB 32 Amps complete all as specified and as directed.
Supply and fix in repair of industrial metal socket and plug 63 Amp (3Phase and Netural & earth ) 4mod IP: 30 Protation including 63 Amps TPN MCB complete all as specified and as directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 6 Sqmm 2 core laid on walls/floors or in air with saddles and gutties complete all as specified and directed. Make :- Gloster / Havells / CCI.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 10 Sqmm 4 core laid on walls/floors or complete all as specified and directed. Make :- Gloster / Havells / CCI.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 16 Sqmm 4 core laid on walls/floors or in air with saddles and gutties including PVC conduit complete all as specified and directed. Make :- Gloster / Havells / CCI.
M&L in repair of VTPN Vertical three phase distribution board, VTPN, 4 way 440 volts having IP-54 isolated busbar assembly IK 09 Mechnical impact strength door earthing protection, double door with provision and fixing of MCCBs as incomer up to 125 Amps and MCBs as outgoing complete all as specified and as directed .
Supply and fix in repairs of MCCB 4P 63 Amps /415Volts ,having breaking capacity 16 KA with complete accessories as per existing suitable size complete all as specified and as directed
Supply and fix in repairs of MCCB 4P 100 Amps /415Volts ,having breaking capacity 16 KA with Complete accessories as per existing suitable size complete all as specified and as directed
M&L in repair Sheet metal enclosures for DBs SPN 12 way with 200Amps rated busbar including accessories therein and disposing off complete all as specified and directed.
M&L in repair Sheet metal enclosures for DBs SPN 8 way with 200Amps rated busbar including accessories therein and disposing off complete all as specified and directed.
M&L in repair of MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.
M&L in repair MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.
M&L in repair MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.
M&L in repair of MCB TPN 40-63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and as directed by Engineer-in-Charge.
M & L for Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
M&LCommon burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
Supply and fixing of DWC HDPE tubing 40 mm including all fitting/fixtures such as Tee/Elbow/Socket/ Nipple etc.Conforming to IS 16205 bore for laying cable, cut to size and making the tubing for cable protection along with drawn in cable into the HDPE tubing on the surface/on the wall /along drainage etc cutting of road etc cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note :- (a) The using of GI Clamp in the wall/drainage,etc rate are deemed to be included in the quoted rate and nothing shall extra paid to contractor.
M&L 3 core 2.5 sqmm unarmoured copper conductor PVC insulated PVC sheated as per is 694 up to date all including drawing through PVC Conduit light fitting upto height 30mtr tower/hanger/building etc complete all as specified and as directed by enginer in charge .
M&L 4 core 10 sqmm copper conductor PVC insulated PVC sheated as per is 694 up to date all including drawing through PVC Conduit light fitting etc complete all as specified and as directed by enginer in charge .
Supply and fixing ,instalation,commissioning and testing moveable type polycarbonate ASTA CPRI appproved OEM made Outdoor power supply panel .the panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4; anti-acid, anti corrosive & Shock Proof. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. DEGREE OF INGRESS PROTECTION IP 65 ACCORDANCE WITH IEC 60529 and panel should passed glow wire test 960oC in accordance with 60695-2-11 (flam retardant and self-extiguishing). The gasket should be internally embedded amde of polyurethane and Enclousers make Hensel/ Clipsal. The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Ploycarbonate thermoplastic panel in accordance with IEC 60439-1 the ASTA CPRI report shall have mention of following tests performed and passed out satisfacorily Temperature Rise, Dielectric properties, Short circute withstand current - Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective circutes and submit the copy of type test reports for Plycarbonate Thermoplastic Board only. The panel Floor mounting type with stand and Copper Bus 125A TPN with color Coding. Make - Hensel//Schneider/ABB. Incomer MCCB 100A FP 25 KA Thermal/Maganetic Released with Spreader Link - 1 No LED indicator RYB-1 Set Outgoings Qty No 1 (i)Socket 63A 5P 3P+N+E+ CEE Type -Qty 1 No (Make - Hensel//Schneider/ABB) (ii)Socket 32A 3P 1P+N+E+ CEE Type -Qty 1 No (Make - Hensel//Schneider/ABBl)
ANIKET TRADERS
DAVINDER SINGH
ASIA BUILDER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .