| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC 143 C DR RAJENDRA ROAD KOLKATA 700020 | KOLKATA | KOLKATA | WEST BENGAL | 700020 | ₹3.8 L | L1 | Accepted-AOC AOC |
| 2 | L2₹3.9 L+₹8,633 (2.26%)Rejected-Finance KUDARAT DAKSHINPARA P O R K PALLY P S SONARPUR DIST SOUTH 24 PARGANAS PIN 700150 | SONARPUR | SOUTH 24 PARGANAS | WEST BENGAL | 700150 | ₹3.9 L+₹8,633 (2.26%) | L2 | Rejected-Finance Higher than Lowest Bid Quoted |
| 3 | L3₹3.9 L+₹11,423 (2.99%)Rejected-Finance | ₹3.9 L+₹11,423 (2.99%) | L3 | Rejected-Finance Higher than Lowest Bid Quoted |
| 4 | L4₹4.0 L+₹14,436.50 (3.77%)Rejected-Finance MIA GARAGE BUILDING 1ST FLOOR HILLCART ROAD DIST SILIGURI PIN 734401 | SILIGURI | SILIGURI | WEST BENGAL | 734401 | ₹4.0 L+₹14,436.50 (3.77%) | L4 | Rejected-Finance Higher than Lowest Bid Quoted |
| 5 | L5₹4.0 L+₹20,033 (5.24%)Rejected-Finance 14 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | ₹4.0 L+₹20,033 (5.24%) | L5 | Rejected-Finance Higher than Lowest Bid Quoted |
| Sl No | Description | Qty | Unit | T.D.K. ENTERPRISE L5 | VAIRAB ENGINEERING L2 | BANERJEE CONCERN L3 | BIKASH ENTERPRISE L1 | M/S. N.C. HORE L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment.
a) 2way | 2 | sets | 325 ₹650 | 322 ₹644 | 321 ₹642 Lowest | 350 ₹700 | 323 ₹646 |
| 2.00 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.as per directio by EIC.[Make-Legrand],
a) 16A DP MCB | 2 | sets | 655 ₹1,310 | 650 ₹1,300 Lowest | 650 ₹1,300 Lowest | 675 ₹1,350 | 652 ₹1,304 |
| 3.00 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (make-as direction of EIC) of the following sizes in the prelaid polythene pipe/PVC rigid conduit/GI conduit and by the prelaid GI fish wire and making necy. connection as required.
a) 2x1.5sqmm + 1x1.5sqmm | 115 | mtr | 58 ₹6,670 | 57 ₹6,555 | 57 ₹6,555 | 55 ₹6,325 Lowest | 57.5 ₹6,612.5 |
| 4.00 | b) 2x2.5sqmm + 1x2.5sqmm | 120 | mtr | 80 ₹9,600 | 78 ₹9,360 | 88 ₹10,560 | 65 ₹7,800 Lowest | 79 ₹9,480 |
| 5.00 | c)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC | 50 | mtr | 115 ₹5,750 | 113 ₹5,650 | 113 ₹5,650 | 105 ₹5,250 Lowest | 114 ₹5,700 |
| 6.00 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 2x1.5sqmm + 1x1.5sqmm | 4 | sets | 17 ₹68 | 15 ₹60 Lowest | 19 ₹76 | 15 ₹60 Lowest | 16 ₹64 |
| 7.00 | b) 2x2.5sqmm + 1x2.5sqmm | 4 | sets | 22 ₹88 | 20 ₹80 | 21 ₹84 | 18 ₹72 Lowest | 21 ₹84 |
| 8.00 | b)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) | 5 | sets | 27 ₹135 | 25 ₹125 | 23 ₹115 Lowest | 28 ₹140 | 26 ₹130 |
| 9.00 | Supplying and fixing 20 mm dia PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works . | 275 | mtrs | 63 ₹17,325 | 61 ₹16,775 | 60 ₹16,500 | 55 ₹15,125 Lowest | 62 ₹17,050 |
| 10.00 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. | 2 | nos | 940 ₹1,880 | 934 ₹1,868 Lowest | 934 ₹1,868 Lowest | 1,005 ₹2,010 | 935 ₹1,870 |
Tender Value
₹4.0 L
EMD Value
₹7,900
Closing Date
30 Jul 2024, 2:00 pmClosed
AE_KCESD_II
14 Beliaghata Main Road Kolkata 700015
AMC Electrical Installation GCECTKolkata Special repairing of Electrical Installation at Govt College of Engg and Ceramic Technology Kolkata
2024_PWDE_715412_1
WBPWD/AE/29/Q/ KCESD/II of 2023-24 (4th Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Ceramic Technology Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,900
Office of the AE_KCESD_II
7 Sept 2026
16 Jul 2024
1 Aug 2024
16 Jul 2024
30 Jul 2024
23 Jul 2024
23 Jul 2024
Amount
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. a) 2way
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.as per directio by EIC.[Make-Legrand], a) 16A DP MCB
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (make-as direction of EIC) of the following sizes in the prelaid polythene pipe/PVC rigid conduit/GI conduit and by the prelaid GI fish wire and making necy. connection as required. a) 2x1.5sqmm + 1x1.5sqmm
b) 2x2.5sqmm + 1x2.5sqmm
c)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a) 2x1.5sqmm + 1x1.5sqmm
b) 2x2.5sqmm + 1x2.5sqmm
b)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm)
Supplying and fixing 20 mm dia PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works .
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with separate 16A Modular typeswitch, without plug top on 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and makingnecy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 nos 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with separate 2 nos 6A Modular typeswitch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and makingnecy. connections with PVC Cu wire and earth continuity wire etc.
Supply and fixing of single phase timer box recessed in wall, with locking arrangement & DIN Rail consisting of following items including necessary interconnection by suitable size of stranded PVC insulated 1.1 kv grade copper wire after crimping as per direction of EIC and suitable auto-manual bypass arrangement . a) Double door (2+8) way SPNDB with IP-42/43 protection (Make-Legrand/L&T). b)DIN mounted Digital/Analog timer having provision of adjustment 24 hour [Make:Havells,cat no-DHTED15016; OR same spec of Legrand/L&T). c) DIN mounted power contactor with 250 Volts magnetic coil with two pole having one(1) NO & one(1) NC contact(Make:Havells,HPHF018100*18A 2P HGS Contactor ) OR same spec of L&T/ ABB). d) 2- pole 25/32 Amp. 10KA DIN mounted DP MCB, "C" curve (Make: L&T/ Legrand). e) One no. 220 Volts 20 Amp SPDT toggle switch for bypass arrangement(Make: Kayee//L&T or aproved make). f) One no. red and one no. green240V LED indicator for indicating Auto & Bypass indication( Make: L&T Cate No-Gen next Pro LED Indicator,) or aproved make--- 1 set
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run.(8 vertical run for 4 storied)
Supply & fixing of 230V AC full metal body 16 inch sweep wall bracket fan (Make EPC, Orient, Crompton)
Supply of 1200mm sweep ceiling fan complete blades,canopy,fork,rubber bush,etc (Make-Orient Electric Apex Prime 1200mm High Speed Ceiling Fan Smoke Brown or similar spec of Crompton/Usha, as per direction of EIC).
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush, etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S.
Taking down the Ceiling Fan 900/1200/1400 mm sweep (GEC/ Crompton/Usha/Havell’s etc.) with necessary tools and tackles and testing, checking, servicing, cleanning and re-fixing the ceiling fan on its original position.
Opening the Ceiling Fan 900/1200/1400 mm sweep (GEC/ Crompton/Usha/Havell’s etc.) with necessary tools and tackles and testing, checking, servicing, overhauling including supplying 23/36 PVC Copper flexible wire up to length 1.0 Meter. And transportation charges etc. and re-fixing the ceiling fan on its original position.
Opening the Ceiling fan testing, checking and Re-winding by supplying super enamelled copper wire of appropriate gauge, minilex paper, mica sheet, changing the loops, overhauling, backing, varnishing, re-fifling and using and measuring r.p.m. for ceiling fan above 36” sweep up to 60” sweep.
Supplying & fixing of following sizes bearing: a) Bearing No. 6201 (SKF or Equivalent)
b) Bearing No. 6202 (SKF or Equivalent)
Supplying & fixing of following sizes safety twisted wire for existing ceiling fan made with steel materials,1.6 mm tickness. Incl all required accessories for fixing ceiling fan as per direction by EIC.(aprove make) a) upto 400 mm length
b) upto 800 mm length
c) upto 1600 mm length
Extra for suspension of ceiling fan exceeding 25 cm with S&F additional 1 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.as per dirction by EIC.
Driling holes on fan motor and down road incl S&F split pin.
Supply & fixing of split pin.
Di-electric test of transformer oil before filteration and after filteration as per direction of EIC.(TR1, HT OCB,LT OCB)
Dehydration and filteration of transformer oil of (01) no Transformer.
Carrying charges of Transformer oil, filteration Machine, Testing machniary from work shop to work site and work site to work shop.
Supply and pouring of New Transformer Oil for top up of Transformer ( Power oil).
S&F of Gasket to prevent the oil leakage 1no. for top cover 5 nos for LT & HT bushing 4 nos for radiator 1 no for oil pump incl. required accessories.
Supply and pouring of Silica Gel .
Servicing of 250KVA Transformer incl. H.T & L.T bushing incl. clening checking, testing etc as required incl. Testing the IR Value by Insulating testing Megger be for charging.
Supply and fixing oil Seal ( LT-2 Nos & HT-6 Nos each transformer).
Throughly servicing and overhauling of 6/11KV grade 400A capacityHT OCB ( BIECO L) incl. removal of OCB with self contained tank and dismentling all components of electrical and mechnical portion incl. cleaning the dities, moisture of the BBC, HT bushing Spout, incl. V- contract, fingure contract by CTC oil and petrolium jelly after all necessary work and then testing of IR Value by 2500 Volt Insulating testing megger.
SITC of whole system after testing the complete installation like 6KV/440V 250KVA power Transformer, HT OCB including HT cable and all other protective relays & equipmets by Govt authorised Firms and their testing equipments including the necessary test report will be submit within 07 days of servicing.
Repairing servicing and overhauling of 1no. PT ( BIECO ) and dismentling all components of electrical and mechnical portion incl. cleaning the dities, moisture CTC oil and petrolium jelly after all necessary work and then testing of IR Value by 5000 Volt Insulating testing megger.as per direction of EIC.
checking,servicing and cleaning of APFC panel (capacitor bank panel-2 and main LT panel-I no) as per direction of EIC
VAIRAB ENGINEERING
BANERJEE CONCERN
M/S. N.C. HORE
T.D.K. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .