Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC 4 KHEME KA KUA PAL ROAD JODHPUR RAJASTHAN 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Ok | |
| 2 | L2₹23.5 L+₹3.8 L (19.1%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹27.9 L+₹8.2 L (41.6%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLAGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Other than lowest |
Tender Value
₹35 L
EMD Value
₹49,800
Closing Date
1 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UTARLAI
GARRISON ENGINEER AIR FORCE UTARLAI PB NO 11 BARMER (RAJ) PIN 344001
PROVN OF PRE-FABRICATED CABIN AT AF STN UTARLAI
2020_MES_355710_1
8120/02/E8 dt 25 Jun 2020
Open Tender
Civil Works
Item Rate
180 days
GE AF UTARLAI
As per NIT
7 documents required · 7 mandatory
₹500
GE AF UTARLAI
₹49,800
Yes
25 Dec 2020
25 Jun 2020
3 Aug 2020
25 Jun 2020
1 Aug 2020
20 Jul 2020
60 days
Amount
M&L for Design, Manufacture, Supply and Installation of Prefabricated cabin of size Length 08Mtr, Width 05Mtr and Height 04Mtr complete all as shown in the drawings and as specified in Particular Specification. The cabin shall be installed on top of 2.30Mtr hight platform (Plinth) of size length 15Mtr & Width 13Mtr. Note:- (i) Line plan, elevation & section of the structure to be constructed is enclosed with tender documents for reference purpose only. The Pre-Fabricated cabin shall be provided completely as per approved drawing submitted by the contractor. The contractor shall got approve the complete drawings of shelter and drawing & design of platform from GE before execution of the work at site. (ii) Drawing & Design of the structure: The contractor shall produce the complete architechure Drawing & design of the structure including Drg & Design of platform (Plinth) duly vetted by the Govt Engineering Collage. The Soil testing shall also be carried out by the contractor before commencement of work. The soil testing shall be assessed by two Nos of bore hole in entire area of site as per the instruction of the testing agency. The design of structure shall be carried out considering the report of Soil testing as per the safe bearing capacity. The complete cost of Soil testing & Drawing including design and vetting of the structure shall be deemed to be included in the quoted rate of this item. (iii) The cost of Platform (Plinth) is not included in quoted rate of this item. The complete plinth shall be constructed as per appproved design and shall be measured and paid seperately under Ser Item No 02 to 20. (iv) E/M Accessories The cost of following E/M acessories shall deemed to be included in quoted rate of this item:- (a) 15 Amp socket point Ac - 06 Nos (b) 5 Amp socket point AC - 06 Nos (c) OFC cable entry point - 01 Water proof (d) Electrical cable entry point - 01 water proof (v) Tube light / LED lights - 08 Nos (vi) 1.5 Ton Split Ac - 02 nos
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed
Removing excavated material n exc. 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in soft/loose soil complete all as specified and directed
M&L for earth filling under floor spreading and levelling in layers n. exc 25 cm thick well ramming including watering as required complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed
M&L for RCC M-25 design mix foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L for RCC M-25 design mix Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like concrete complete all as specified and directed
Use waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work rough finished surfaces of concretein flat complete all as specified and directed
Use waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified.
Use waste of formwork to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified.
M&L for hardcore broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
M&L for 100mm thick cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in sub base flooring incl finishing the concrete surface concrete complete all as specified and directed
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
-ditto- all as per Item Ser No 15 above but 6mm to 8mm dia complete all as specified and directed
-ditto- all as per Item Ser No 15 above but 5mm dia and over upto and including 10mm dia in stripps, spacers and binder etc complete all as specified and directed
M&L for precast cement concrete block masonary with solid blocks made of PCC (1:3:6) typeC-1 using 20mm graded stone aggregate exc 10cm in width and set in CM 1:6 complete all as specified and directed
M&L for rendering 15mm thick in cement mortar (1:6) on concrete/brick wall surface finished even and smooth without using extra cement complete all as specified and directed
M&L for 75mm thick cement concrete 1:3:6 type B-1 (using 20mm graded stone aggregate) as in plinth protection finished surface even and smooth without using extra cement complete all as specified and directed
M&L for preparation on new plaster surface of walls & applying two coat of cement base paint over a coat of primer complete all as specified and directed
M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in surface channel and drains complete all as specified and directed
S&F MCB DB TPN 415 Volts 200 Amps rated bus bar 4 ways with double door shutter fixed flush with wall surface complete all as specified and directed.
S&F MCCB 3 pole 415 volts fixed type 63 Amps with breaking capacity 60KA complete all as specified
S&F MCB single pole and neutral 240 Volts upto 32 Amps complete all as specified.
Supply, laying and testing of LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sq mm 3.5 core complete all as specified.
S&F GI Pipe lioght grade including all GI fittings fixed on wall, laid under floor/roads of size 50 MM dia for protection of cable complete all as specified and directed.
S&F cable tray for laying of different cable made/fabricated of MS sloted fixed on angle iron of sizes 25x25x3mm , Cable tray size in width 30cm complete painted fixed to the wall/floor with grouting the supports and fixing of cable in roots complete all as specified and directed
M&L for chemical earthing complete with plate 90x60cmx5mm thick copper plate electrode buried direct in ground vertically not less than 4 mtrs deep below ground level with top edge of the plate not less than 3.3 mtrs deep below ground level with connected to copper strip of size 32x6 mm as earthing lead 3 Nos 90 cm long and inter connected 25x5 mm thick copper strip as earth lead by means of bolts, nuts, and brazing , check nuts and washers all as directed to test point including necessary excavation and earth work (in any type of strata) and providing charcoal dust , common salt , copper suphate and all around the plate 15 CM depth and wide and up to 2 mtr height in continuous layers, balance pit will be filled with soil up to ground level including watering pipe GI medium grade of 20mm bore and 40 mm bore pipe medium grade for earth strip protection up to 7.5 mtr , PCC (1:3:6 ) type C1 chamber , cast iron chamber frame , heavy duty funnel and CI pit cover complete all as specified and directed .
Earth continuity conductor fixed to wall on wall or recess or buried in ground or drawn GI pipe or any indicated situation copper strip 32x6 mm complete from the machinaries/plants upto the test point complete all as specified and directed by the Engr-in-Charge
S&F test point terminal box made of gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 03 Nos 8mm dia, 25 mm long Hex head screws complete all as specified and directed
Godara Construction and General Suppliers
Hariom Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .