Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹32,490Qualified Make: BPE
Model: BPE NIY LI 1.0KVA 168VAH 5YR 3PIN AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE NIY LI 1.0KVA 168VAH 5YR 3PIN | ₹32,490 | L1 | Qualified |
| 2 | L2₹65,000+₹32,510 (100.1%)Qualified Make: MICRO POWER
Model: MPT-1168 KALI MANDIR ROAD GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | Make: MICRO POWER
Model: MPT-1168 | ₹65,000+₹32,510 (100.1%) | L2 | Qualified |
| 3 | L3₹71,990+₹39,500 (121.6%)Qualified Make: Uniline
Model: Smartline-SL-1000-168-EA 198 23 UNILINE HOUSE EAST OF KAILASH RAMESH MARKET NEW DELHI DELHI 110065 | SOUTH EAST DELHI | DELHI | 110065 | Make: Uniline
Model: Smartline-SL-1000-168-EA | ₹71,990+₹39,500 (121.6%) | L3 | Qualified |
| 4 | L4₹72,750+₹40,260 (123.9%)Qualified Make: microtek
Model: ADUPS06 2 RANA SAMAY SINGH DURG MAHARANA PRATAPGARH KAKROLA VILLAGE SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | Make: microtek
Model: ADUPS06 | ₹72,750+₹40,260 (123.9%) | L4 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
27 Jun 2018, 10:00 pmClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 5 Years 5 Years Installation and commissioning instructions No - CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through inverter) No Yes
No 1/4 Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) - - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - 2/4 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 81000043 DATED – JUN -16 - Name Of Lab BIS REGISTERED AND ETDC (GOVT OF INDIA LAB) - Address of Lab BIS DELHI AND ETDC MOHALI PUNJAB (GOVT OF INDIA LAB) - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dr.Hanumant Singh Chouhan 307026
S.M.C.C. COLLEGE ABUROAD
PALANPUR ROAD
KESARGANJ
ABUROAD 10 15 EMD Required No ePBG Required No
203851
GEM/2018/B/29024
Line Intractive UPS with AVR
15 days
Rajasthan; Sirohi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 5 Years 5 Years Installation and commissioning instructions No - CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through inverter) No Yes | - | - | - |
| No 1/4 Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) - - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - 2/4 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 81000043 DATED – JUN -16 - Name Of Lab BIS REGISTERED AND ETDC (GOVT OF INDIA LAB) - Address of Lab BIS DELHI AND ETDC MOHALI PUNJAB (GOVT OF INDIA LAB) - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dr.Hanumant Singh Chouhan 307026 | - | - | - |
| S.M.C.C. COLLEGE ABUROAD | - | - | - |
| PALANPUR ROAD | - | - | - |
| KESARGANJ | - | - | - |
| ABUROAD 10 15 EMD Required No ePBG Required No | - | - | - |
Exempted
27 Jun 2018
13 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_203851.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .