Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹44.8 L+₹1.7 L (3.95%)Rejected-Finance KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹45.2 L+₹2.1 L (4.88%)Rejected-Finance 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L3 | Rejected-Finance Not being L1 | |
| 4 | Rejected-Technical OPP MARICAR HOSPITAL JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | - | Rejected-Technical Not having category and residual work load not submitted | |
| 5 | Rejected-Technical PB NO 809 ABERDEEN BAZAR PO ATLANTA POINT NEAR POLICE WIRELESS PORT BLAIR 744104 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744104 | - | Rejected-Technical Not having category |
| Sl No | Description | Qty | Unit | Kakolil Trade Agencies L2 | Tropical Refrigeration L3 | Everest Cooling Works L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling old unserviceable/defective Split AC of Capacity 1.5 TR / 2 TR complete with indoor units & outdoor unit all connected accessories complete, transporting and depositing to MES store yard. | 34 | Each Job | 2,000 ₹68,000 Lowest | 2,100 ₹71,400 | 2,000 ₹68,000 Lowest |
| 2.00 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit with minimum 5 star rating of capacity 2.0 TR complete all as specified and as directed.
Make: - Blue Star/ Daikin/Hitachi/Carrier/Voltas. | 16 | Each | 1,29,000 ₹20,64,000 | 1,30,000 ₹20,80,000 | 1,27,000 ₹20,32,000 Lowest |
| 3.00 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit with minimum 5 star rating of capacity 1.5 TR complete all as specified and as directed.
Note for item No 2.00 & 3.00:
(a) The cost of remote with batteries, compressor oil, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate.
(b) Drilling of the wall should be done by core cutting machine.
(c) Cost of copper tubing, refrigerant gas & mounting bracket will be measured and paid separately. | 18 | Each | 84,000 ₹15,12,000 | 86,000 ₹15,48,000 | 81,000 ₹14,58,000 Lowest |
| 4.00 | S&F of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps including dismantling of olne one complete all as specified and as directed. | 34 | Each | 2,400 ₹81,600 | 2,300 ₹78,200 Lowest | 2,300 ₹78,200 Lowest |
| 5.00 | M&L for Air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on wall complete suitable for 1.5/2.0 TR suitable for outdoor unit including dismantling of olne one complete all as specified and as directed. | 34 | Each Set | 2,300 ₹78,200 | 2,300 ₹78,200 | 2,200 ₹74,800 Lowest |
| 6.00 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and as directed. | 16 | Each | 5,500 ₹88,000 | 5,400 ₹86,400 | 5,000 ₹80,000 Lowest |
| 7.00 | Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 3.0 KVA complete all as specified and as directed. | 18 | Each | 5,000 ₹90,000 | 4,900 ₹88,200 | 4,500 ₹81,000 Lowest |
| 8.00 | Supply and fixing for replacement of Copper tubing of size 1/2" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed. | 20 | RM | 1,450 ₹29,000 | 1,390 ₹27,800 Lowest | 1,390 ₹27,800 Lowest |
| 9.00 | Supply and fixing for replacement of Copper tubing of size 3/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed. | 25 | RM | 2,000 ₹50,000 | 1,950 ₹48,750 | 1,900 ₹47,500 Lowest |
| 10.00 | Supply and fixing for replacement of Copper tubing of size 1/4" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed. | 20 | RM | 1,690 ₹33,800 | 1,600 ₹32,000 | 1,560 ₹31,200 Lowest |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
11 Jan 2025, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8505- SPECIAL REPAIR FOR REPLACEMENT OF OLD VINTAGE/ BER SPLIT AC AND CONNECTED ACCESSORIES AT INHS DHANVANTRI AND PROVN OF GEYSER AND EXHAUST FAN AT BUILDING NO P-163 (SINGLE LIVING BLOCK) OF STATIC WKSP EME UNDER AGE E/M-I, GE MINNIEBAY,
2024_MES_689745_1
8505/E8
Open Tender
Civil Works
Item Rate
180 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
GE, Minniebay
₹83,000
Yes
22 Aug 2025
21 Dec 2024
13 Jan 2025
21 Dec 2024
11 Jan 2025
4 Jan 2025
Amount
Dismantling old unserviceable/defective Split AC of Capacity 1.5 TR / 2 TR complete with indoor units & outdoor unit all connected accessories complete, transporting and depositing to MES store yard.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit with minimum 5 star rating of capacity 2.0 TR complete all as specified and as directed. Make: - Blue Star/ Daikin/Hitachi/Carrier/Voltas.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit with minimum 5 star rating of capacity 1.5 TR complete all as specified and as directed. Note for item No 2.00 & 3.00: (a) The cost of remote with batteries, compressor oil, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate. (b) Drilling of the wall should be done by core cutting machine. (c) Cost of copper tubing, refrigerant gas & mounting bracket will be measured and paid separately.
S&F of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps including dismantling of olne one complete all as specified and as directed.
M&L for Air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on wall complete suitable for 1.5/2.0 TR suitable for outdoor unit including dismantling of olne one complete all as specified and as directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and as directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 3.0 KVA complete all as specified and as directed.
Supply and fixing for replacement of Copper tubing of size 1/2" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed.
Supply and fixing for replacement of Copper tubing of size 3/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed.
Supply and fixing for replacement of Copper tubing of size 1/4" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed.
Supply and fixing for replacement of Copper tubing of size 5/8" flare size conforming to relevant IS with foam insulation & wrapping tape including required copper brazing work complete all as specified and as directed.
Supply & fixing submain wiring with PVC insulated unsheathed multi-stranded copper conductor cable two run of 4 Sqmm single core (FRLS) 1100 volts grade drawn through in and including PVC casing caping for surface wiring with casing caping accessories laid on wall/ceiling and one run of 4 Sqmm PVC insulated copper conductor(FRLS) for earth continuity wire including taking down old wiring complete all as specified and as directed. Note : Two run of single core cable with one run of earth continuity conductor and PVC casing caping and accessories will be measured as one length.
Supplying and laying of CPVC pipes of 25mm outer dia, SDR 11 & Plain CPVC SDR 11 fittings for drain out AC condensation with complete fixed on wall with suitable clamps including taking down old unserviceable drain complete all as specified.
Supply and charging refrigerant gas environmental friendly refrigerant gas as per OEM design for gas charging complete.
M&L for point wiring of exhaust fan controlled by one switch with two run of PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm (FRLSH), PVC conduit medium grade/ PVC casing caping and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing one run of 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable (FRLSH) as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and as directed by Engr-in-Charge.( In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.
M & L for submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable of size 4.0 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 4.0 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification complete all as specified and as directed. Note : (i) Three run of cable with one run of PVC conduit/PVC casing and caping will be measured as one length. (ii) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.
Supply & fixing switch piano, flush type single pole, one way 5 Amps complete all as specified and as directed
Supply & fixing ceiling Rose, 3 terminal polycarbonate isolated body complete all as specified and as directed.
Supply & fixing exhaust fan made of steel body complete with louvers, voltage 230V, 50 HZ, RPM 900, Copper winding of sweep 300mm and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of exhaust fan complete all as specified and as directed.
Supply & fixing electric water heater, storage type steel body with MS inner tank, wattage 2 KW, capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece, fastner bolts including stainless steel hose pipe complete all as specified and as directed.
Supplying and laying on wall of CPVC pipes outer diameter 20mm SDR 13.5 pipes & plain CPVC SDR 11 fittings complete all as specified and as directed.
Supply and fixing Stop valves 20mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
Supply and fixing Bib tap standard 20 mm PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 20mm-125gms) complete all as specified and as directed
Supply and fixing Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed.
Kakolil Trade Agencies (BID ID -3210830)
Tropical Refrigeration (BID ID -3211436)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .