Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC WZ 199 LAJWANTI GARDEN GALI NO 4 NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.1 L+₹22,153 (0.72%)Rejected-Finance RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹31.6 L+₹80,562.72 (2.61%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹33.4 L+₹2.6 L (8.46%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹34.9 L+₹4.1 L (13.1%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
11 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
PROVN OF CERTAIN SANCTION WORK IN THE AREA OF AGE B/R-II AND AGE E/M (CENTRAL) UNDER GE (CENTRAL) DELHI CANTT-10
2023_MES_620150_1
GE/C-54/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹92,000
Yes
9 Nov 2023
22 Sept 2023
13 Oct 2023
22 Sept 2023
11 Oct 2023
6 Oct 2023
22 Sept 2023 - 6 Oct 2023
Amount
M & L for removal of plants ( area with in n exc 0.50sqm) growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water, including taking out roots from roof / brick work and making good the disturbed surface with plaster and PCC 1 :2:4 type B0 and disposing the rubbish from site (MOD land) for a block of eleven flats of 5 storey height complete and as specified.
M &L for Brushing neat cement slurry with 3 Kg of cement per square metre complete all as specified and directed .
M&L for PCC 1:2:4 of 50 mm thick (using 12.5 mm aggregate) type B-0 as in levelling course using WPC (@ 3% of cement wt.) finished even and smooth without using extra cement upto G+3 storey bldg. Note:- cost of WPC will be paid separtely.
M&L for 15mm average thick (average) rendering in cement mortar 1:4 using WPC (@ 3% of cement wt.) on roof surfaces & finished even and smooth with using extra cement in any position upto G+3 storey bldg complete all as specified. Note:- cost of WPCwill be paid separtely.
M & L for applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on top of roof surface in multiple coats @2 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and other coats needs to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. When the 2nd coat is wet, the Smartcare EPDM tape (at corners and edges)shall be inserted between second and third coat to secure corners & edges, let the material ooze out from the tapes corner. Same treatment of Smartcare Dampproof shall be continued to the parapet walls to better envelope the whole area. The coating shall be terminated carefully to the other side of the parapet wall.
Dismantling floor hearth or wall tiling including cement mortor bedding (but not backing) laid bedded and pointed in any mortar and removal of old tiles from premises complete all as specified and directed.
M&L Non skid Coloured ceramic rectified tile 300x300x7-8 mm thick as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L Coloured ceramic rectified tiles 300x600 x 7 to 8mm thick, as in vertical surfaces of wall such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement over and including 10mm thick rendering in CM 1:4 complete all as specified.
S&F for digital glossy finish vitrified tiles 10 mm thick of Dark shade (Square/rectangular) polished area of each tile not exceeding 0. 36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM 1:6 Complete all as specified and directed.
All as per item No 09 hereinbefore but in vertical surfaces such as skirtings, dados and risers to steps etc. incl 10 mm thick rendering in CM 1:4.
S & F in repairs vitreous China coloured European type WC with seat cover and "P" or "S" trap for 100 mm bore , including connection to drain and to flushing cistern with pipe 32mm dia PVC pipe and fixing bolts complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash basin, white, flat back, size 550mm x 400mm complete, Ist quality, incl provn of pair of mild steel angle iron brackets of suitable size duly painted and cutting for and pinning in ends of brackets in walls,making good incl providing and fixing of suitable 32mm dia CP Waste coupling complete all as specified and directed.
S&F 20mm dia GI tubing medium grade with all fittings and connections fixed to wall or ceiling or laid on floor etc incl cutting chasing where required complete all as specified an directed.
All as per item no.13 here-in-before but dia of GI pipe is 15mm.
S & F in repairs PVC valveless syphonic action Dual Flush cistern 10ltr capacity, low level, white with inlet, ball valve, float and handle incl brackets and connection to pipes and fixing of chain and pull or lever if any complete all as specified and directed.
S & F Brass CP basin mixer for mixing hot & cold water screwed down for iron pipe 15 mm bore, screwed down high pressure, screwed for iron pipe and fixed complete all as specified and directed.
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracked guard and railing 60 cm long complete all as specified and directed.
S&F in repairs 15mm bore bib taps fancy type of Chromium plated high pressure screwed for iron pipe and fixed etc. complete all as specified and directed.
S&F in repairs CP brass shower rose 125mm dia with chromium plated arm fixed to 15mm pipe of revolving type complete all as specified and directed.
S&F in repair Stainless steel grating 100mm dia of best quality as approved including fixing in CM 1:4 to floor/nahani traps etc complete all as specified .
S&F in repair PVC connection 15 mm bore and 45cm long with washers complete all as specified and directed.
S&F1000 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and S & F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed incl Dismantling of PVC water tanks of exc 250 litres and n.exc 500 litres capacity of any condition or type incl complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position, complete all as specified.
M&L for Brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
All as per serial item No 25 but except bricks, all as specified. (Servicable bricks retrieved from Serial Item No 01 shall be used).
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish,vegetation etc outside complex (MOD land) complete all as specified and directed.
M & L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed with water proofing compound finished even and smooth without using extra cement with water proofing compound complete all as specified. Note: Cost of WPC will be paid separtely.
M & L for 15 mm thick internal rendering in cement mortar 1:6 on fair face of brick walls/ concrete surfaces & finished even and smooth without using extra cement, complete all as specified.
M&L for applying of wall care putty on newly/old plastered walls of 2-3mm thick including preparing the surface with even and smooth complete all as specified and directed. Note : Wall putty to be procured from manufactures directly.
M&L Preparation of newly/old plastered surfaces of walls and applying two coats of Oil bound distember on walls complete all as specified and directed.
M&L Preparation of newly/old plastered surfaces of walls and applying three coats of white wash on walls complete all as specified and directed.
M&L Preparation of newly/old plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M&L Preparation of newly/old plastered surfaces of walls and applying two coats of weather coat/apex paint on walls/ceilings complete all as specified and directed. Note: The weather coats will be carried by authorised applicator. (a) MOU with authorised applicator will be uploaded with tender documents, in absence of the same the tender will not be admitted. (b) On completion 10% amount for amount of weather coat will be retained for 5 years in token of guaranttee of quality.
Taking down chowkats or frames not exc. 1.5 sqm each (with shutter without taking off shutter) complete all as specified.
Taking down chowkats or frames exc 1.5 sqm but n.exc 4 sqm each (with shutter without taking off shutter) complete all as specified.
M&L second class hard wood plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints including treating the back of chowkhat with two coat of black japan/bituminiuos paint complete all as specified and directed.
S& F 35 mm thick flush shutters (factory made) solid core construction, with block board core and plywood face panel, commercial type on both sides. Flush shutters shall have teak wood edging as specified in IS (incl two nos 150 mm long extruded aluminium tower bolts, three nos 100mm long medium weight MS butt hinges, two nos 150 mm long extruded aluminium handles, one door stopper140mm long extruded aluminium and one no 300 mm long Aluminum Sliding door bolts and two coats synthetic enamel paint along with one coat of pink primer), complete all as specified and directed. Note :- Rate quoted are deemed to be inclusive of fixture and fittings mentioned to each door shutter and painting.
Aluminium anodised single/double shutter window (glazed and wire gauge) side hung/sliding with aluminium window frame or chowkat 1.5 mm thick aluminium anodised of size 100 mm x 44.5 mm and window shutter frames glazed and wire gauze (middle, toprail, bottom rail) and styles 1.5 mm thick aluminum anodised of size 44.5x44.5 mm incl aluminium grill,stinless steel wire mesh and all fitting such as rubber gasket aluminium glazing clips locking cabinet and 75 mm handle and including 4 mm thick tinted glass pane in panes fixed with rubber gasket and glazing clip/aluiminium beads aluminium tower bolt 75 mm 02 Nos , aluminium butt hinges 75 mm 02 Nos in each shutter aluminium handle 100 mm 01 No in each shutter incl all accessories complete all as specified and directed.
M&L for followings :- (i) M&L for chipping of spalled and loose concrete and Removing plaster & finishes all around the coloumns, slabs & beams (on all four sidescription of column to full height , three sidescription of beam to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. Note : The rate quoted by the contractor is inclusive of scaffolding and the item shall be executed in small patches/large patches based on site requirement.
M & L for removal of rust from reinforcement completely by rubing with wire brush or emeray paper and proper cleaning of reinforcements with RUSTKLENE or Sika rust off-100 (Rust converter manufactured by Sika India Pvt Ltd) or equivalent in MC Bauchemie India Pvt Ltd, or FOSROC Industries Bangalore as per manufacturer’s instructions complete all as specified and directed. Note : The rate quoted by the contractor is inclusive of scaffolding and the item shall be executed in small patches/large patches based on site requirement.
M & L for application of zinc rich primer coat for corrosion protection on reinforcement bars BUILDCOAT (ZP) or Friazinc-R (Primer manufactured by Sika India Pvt Ltd) and shall be applied in a manner such that primer shall be a coating of atleast 40micron complete all as specified and directed. Note : The rate quoted by the contractor is inclusive of scaffolding and the item shall be executed in small patches/large patches based on site requirement.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed.
S&F Mild steel TMT bars of 10 mm dia and over cut to length bent to shape required including cranking, bending etc and S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for providing reinforced cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in kitchen slab, Chajjas, lintels incl form work complete all as specified and directed. Note : The rate quoted by the contractor is deemed to include the necessary scafoldings, supports etc. Nothing extra will be claimed on this account. The work will be executed upto G+3 Storyes building.
M & L for 75 mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished fair and even without using extra cement, complete all as specified.
M&L mild steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes including necessary welding etc complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L applying two coats of syntheic enamel paint over a coat of red oxide on steel surfaces of any description over 10 cm width or girth including preparation of new surfaces complete all as specified.
M&L Hardcore of broken stone of gauge n. exc 63mm deposited, spread and levelled in layers not exc 100 mm thick watered and rammed to a true surface complete all as specified and directed.
M&L 100mm thick PCC (1:4:8) type D 2 (40mm graded stone aggregate) as in sub base, complete all as specified.
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose or disintegrated soil complete all as specified by Engineer-in-Charge .Note; Most of the Excavation will be done manually and no extra cost will be paid to contractor seperately for manual excavation. If any UG Cables, Pipes are damaged during excavation,entire cost for restoration will be borne by the contractor
S&F DWCPE(SN4) 150mm diameter sewage pipes including snap fit coupler and rubber ring incl testing ,properly jointing and laying in trenches to a level bed complete all as specified by Engineer-in-Charge
M & L for concrete (1:3:6) type C2 as in bed suitable for 150 mm bore of pipes including forming cradles; complete all as specified by Engineer-in-Charge.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose/disintegrated soil or rocks complete all as specified.
Removing excavated material rocks to a distance exc 1.5 kms but n exc 5 km and depositing where directed .
S&F Precast plastic fibre reinforced concrete man hole covers" medium duty " of overall size 1000 mm x 500 mm x 75 to 80 mm factary made complete all as specified and directed .
M&L Cement Concrete work as in floor/pavement/hardstanding of flexural strength 40 kg/per square centimeter in field using 400kg of cement per cubic metre thickness of concrete 10 cm, finished concrete surface even and smooth without using extra cement in proper leveling, slope and spike rolling to surface or making impressions of expanded metal while concrete is green complete including demolition of existing all as specified and directed.
Forming construction joints 100mm deep x 10mm wide filled with sealing compound Grade'A' completed all as specified and directed.
Supply only WPC
Taking down carefully copper/aluminium point wiring from wooden battan or conduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc.
Taking down old MCCB , TPN DBs , SPN DBs, & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed.
Taking down old submain wiring of any size and make from the site and making good surface complete all as specified.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified.
(a) One light /Ceiling fan/exhaust fan point controlled by one switch.
(b) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
(c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
All as per item No.65 herein before but with 4 Sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. Note for Item 1 & 2 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing&caping/Existing conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC.
M&L for Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLSH cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls all as specified and as directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.
M&L for Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLSH cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls all as specified and as directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible. Note for Item No 66, 67 & 68: (i) PVC conduit shall be Medium grade, ISI marked ,FRLSH Grade
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm FRLS 1100 Volts in New PVC concealed conduit in new M S steel terminal boxes modular including one run of using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, all as specified
M&L switch Modular type 6 Amps one way 230V AC complete all as specified.
M&L Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified.
M&L switch Modular type 16 Amps one way 230V AC complete all as specified.
M&L Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified.
Supply & Fix Modular five stepped type electronic fan regulator 2 module 230V AC complete all as specified.
M&L ceiling rose 3 phase PVC polycorbonate,isolated body.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 4 Sqmm size stranded conductor as earthwire.
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
M&L MCB SPN 40 Amp "C " curve.
M&L MCB SP 6 to 32 Amp "C" curve.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete.
Supply and fix 12 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<20%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 0.75 Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and Fix 100 W High efficient LED Flood light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV for fixing the light fittings on Wall fixed complete as specified and directed.
Supply and fixing ceiling fans against BER three blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, rated Air delivery >220 cum/min, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as directed. Note BLDC Fan should work on existing electronic fan regulator.
Supply & fix in repair factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
M&L in replacement MCCB 125 Amps, 16 KA , 4P, 415 Volts, 50Hz , with thermal magnetic setting.
Supply and fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete
Taking down carefully the existing ceiling fan of 1200/1400mm from its position after disconnecting electric connection and making good surface deposits to MES store all as specified and directed.
S&F in repair MODULAR AC/GEYSER BOX enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed.
Schedule of Credit
SHREE RAM BUILD TECH
M/s SAAR ENGINEERS
imran construction company
POONAM ENTERPRISES
ANSH VANSH CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .