Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.0 LAccepted-AOC FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC FOUND LOWEST | |
| 2 | L2₹56.0 L+₹3.2 L (6.03%)Rejected-Finance H NO 107 A RAJENDRA NAGAR DIGARI KALAN JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹57.9 L+₹5.1 L (9.57%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹58.2 L+₹5.3 L (10.1%)Rejected-Finance B 101 3RD FLOOR JHILMI COLONY DELHI 110095 | DELHI | EAST DELHI | DELHI | 110095 | L4 | Rejected-Finance other than lowest | |
| 5 | L5₹69.0 L+₹16.1 L (30.6%)Rejected-Finance | L5 | Rejected-Finance other than lowest |
Tender Value
₹70.9 L
EMD Value
₹1.3 L
Closing Date
3 Aug 2022, 6:00 pmClosed
CWE DELHI CANTT
CWE DELHI CANTT DELHI 110010
SPECIAL REPAIRS TO BLDG NO P 24 AND P 79 AT OD SAKURBASTI UNDER GE NORTH DELHI CANTT 10
2022_MES_535318_1
CWE/D-12/2022-23
Open Tender
Civil Works
Item Rate
120 days
DELHI CANTT
As per NIT
7 documents required · 7 mandatory
₹1,000
GE NORTH DELHI CANTT
₹1.3 L
Yes
1 Sept 2022
2 Jul 2022
4 Aug 2022
2 Jul 2022
3 Aug 2022
22 Jul 2022
Amount
Demolition of existing water proofing treatment of any description and in any position to expose the top surface of RCC slab including cleaning the surfaces with wire and brush complete all as specified and directed.
M&L cutting out racks to V-section in exisiting roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 mix with WPC complete all as specified and directed.
M&L for 15mm thick screed bed or bedding layer of mortar in cement mortar (1:4) for laying roof finish as padding finish with and incl liquid WPC 200ml by wt of 50 kg cement or as per manufacturer instruction complete all as spcified and directed.
Providing,cement concrete Type B-0 (1:2:4) in roof kerbs of mud stops, rounded or chamfered on edges,roof padding complete all as spcified and directed.
M&L for prepration of the plastered roof surface and fix the APP poluymeric water proofing membrane of minimum 3mm thickness & weighing not less than 3.0 kg/sqm of make : IWL, STP, BENGAL BITUMEN as approved by GE, black finished reinforced with non-woven polyester 160 gsm matt with a thermo fusible finished laid over primer confiming to IS:3384-1965 @ 0.5kg/sqm and thereafter apply computable hot blown bitumen 85/25 @ 1.20 kg/sqm to torching overlaps with a propane or butane gas torch with a overlap of 75mm at the sides and 100mm at the end sealing complete all as specified and directed.
Material and labour for chipping off spoiled and loose concrete from soffits and sides of beam, slab, chajjas and parapet etc clean the surface as directed and apply one layers of guniting using mechanical pressure machine over steel wire mesh 2mm dia 75x75 mm aperture of wire layers n.exc average thickness fixed with tinned tacks/galvanised wire staples/ screws , average thickness of gunite layers n exc 25 mm in Cement concrete 1:1.5:3 using 12.5 mm stone aggregate and finishing with 5 mm thick plastering in CM (1:3) including necessary form work if required at any height from GL and removing off rubbish etc complete all as specified and directed.
Demoltion of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness ( below or above ground level) complete all as specified and as directed.
Taking down cement plaster of any description from brick, stone walls or concrete surfaces including raking out joints, hacking for key,scrubbing down with water etc all as directed and specified.
M&L for rendering 15mm thick on fair of faces of brick work surfaces in cement mortar 1:6, Finish the surface even and fair without using extra cement all as specified and directed.
M&L for preparation of new plastered surfaces any description and apply two coats of cement base paint over a coat of alkali resistant primer on plastered surface area all as specified and directed. .
M&L for rendering 15mm thick on fair of faces of brick work surfaces in cement mortar 1:4, Finish the surface even and fair without using extra cement all as specified and directed.
M&L for preparation of new plastered surfaces any description and apply two coats of oil based paint over a coat of white chalk whiting on plastered surface area all as specified and directed. .
M&L for 10 mm thick plastering in CM 1:3 over ceiling incl finished the surfaces even and fair without using extra cement complete all as directed and specified.
M&L preparation of newly plastered ceiling surfaces of any description and apply three coats of white wash all as directed and specified.
M & L for preparation of old decorated ceiling surfaces plastered or unplastered any description including brooming down or steel wire brushing scrapping down smoke shoot, moulds, mass, efflorescent salts trading oil, greasy spots, stopping holes etc and apply one coat of white lime wash complete all as directed and specified.
M&L for preparation of old decorated previously treated surfaces of wall by brooming down scrapping down smoke and efflorescent salts etc and applying one coat of white wash on walls complete all as specified and directed by Engineer-in-charge.
M&L Preparing plastered or unplastered old decorated surfaces of walls complete removal of exiting treatment and applying two coats of oil bound distemper all as specified .
M&L Preparing plastered or unplastered old decorated surfaces of walls complete removal of exiting treatment and applying two coats of cement based paint all as specified .
Material and labour preparation of new wooden surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer all as directed and specified.
Material and labour preparation of old/previously treated wooden surfaces of any description over 10cm width or girth and apply one coats of synthetic enamel paint all as directed and specified.
Material and labour preparation of old/previously treated steel surfaces of any description over 10cm width or girth and apply one coats of synthetic enamel paint complete all as directed and specified.
M&L 75 mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate, 40mm thick as in floors, finish the surface even & smooth without using extra cement complete all as specified and directed.
M&L for Glass dividing strips, 3mm thick and 38 mm wide complete all as specified and directed
Dismantling floor, hearth or wall tiling incliding cement mortar bedding (but not backing ), removing serviceable tiles to store and rubbish off the premisses, complete all as specified and directed.
M&L granite (of any type) work 18 to 22 mm thick (table rubbed and polished ) in steps , jambs, pillars , window-cills , cooking platforms set and pointing in white cement with admixtures of pigment to match with shade of granite over 15mm thick screed bed or bedding layer of mortar in cement mortar (1:6) for laying floor finish, complete all as specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick, (square/rectangular), area of each tile exceeding 0.11 sqm but nexc 0.18 sqm, in floors etc. set & jointing in neat cement slurry and pointed in white or coloured cement to match over 20 mm thick screed bed or bedding layer of mortar in cement mortar (1:6) for laying floor finish,complete all as specified and directed.
Material and labour for machine cut Kota stone slab 18 to 22mm thick as in flooring, laid over and including cement screed bed 20mm thick in cement mortar 1:6, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
All as per item above but in riser in steps,skiting, dado and pillar laid over and including 10 mm thick plaster in CM 1:4 complete all as specified and directed.
M&L for glazed ceramic tiles of size 350x250x7mm/ 450x350x7mm thick, on vertical surface such as skirting, dados, and risers to steps etc, set & jointing in neat cement slurry and pointing in white or coloured cement to match over 10 mm thick plaster in cement mortar (1:4) as in backing coat to receive wall tiles complete all directed.
Taking down Chowkats or frames shutters (without taking off shutters from the frames)of any descriptions not exc 1.5 sq.m each complete all as specified and directed.
Taking down Chowkats or frames shutters (without taking off shutters from the frames)of any descriptions exc 1.5 sq.m & n'exc 4.00 Sqm each complete all as specified and directed.
Taking down shutters of any description n.exc 1.00 sqm each complete all as specified and directed.
Taking down shutters of any description exc 1.00 sqm but n.exc 2 sqm each complete all as specified and directed.
S&F, pressed steel frame for doors with double re-bate in size 125x60 mm with necessary fixing lugs hinges, lock strike plate etc complete all as specified and directed.
All as per item No. 35 above but single re-bate of size 105x60 etc complete all as specified and directed.
S & F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet re-inforced with MS square tube, S & F in opening as per specification.
S&F35 mm thick 2nd class hardwood plain framed panelled shutters (two panel ) with lock rail and panels of 9mm CWR plywood. The size of rail and stile as per IS 1003 (Qart I), klin seasoned and chemically pressure treated complete all as specified and directed.
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes, top & bottom rail, MS frame shall be covered with heat moulded PVC 'C' channels having PVC strip of 20mm widht struckhuck in side with solvent cement for stiles and wood grain sheet for top rail and bottom rail. Panelling to be fitted in the MS frame welded/sealed to stile and rail with 5mm thick x 15mm wide PVC sheet beading used inside styles and rail decorated PVC beading of 10mm x 10mm (90 digree) used and jointed together with solvent cement supplying and fixing in the frame at site as per manufacturers instructions complete all as specified and directed,
S&F aluminium door shutter with frame100X45X1.5mm powder coated fixed to wall with steel fastnes min four number each side partly glazed with 5 mm thick tinted glass and partly panelled with 8mm thick coloured aluminium composit panels incl rubber beading, joining cleat for fixing in position, 2 numbers aluminium door handle 250 mm long, 1 number aluminium barrel tower bolt 200 mm long ,1 number aluminium floor door spring & one No 4 liver mortice lock of Godrej of size 100 mm in each shutter will be provided all as specified and directed as per following specifications -- (a) Vertical Members of shutter (Style) Section shall be of size 85.00 x 44.45 x 1.50 mm (Section No 19560) (b) Top rail ( Top Members) of shutter Section shall be of size 85.00 x 44.45 x 1.50 mm (Section No 19581) (c) Lock rail (Middle member) of shutter Section shall be of size 150.00 x 44.45 x 1.50 mm (Section No 19596) (d) Bottom rail ( Bottom Members) of shutter Section shall be of size 150.00 x 44.45 x 1.50 mm (Section No 19584) (e) Glazing clip for securing glass of shutters shall be of 0.80 mm thick (Section No 19370). Standered quality rubber beading shall be used for securing of glass (f) Top, Bottom and verticle member of shuttert will be tightened with hexagonal nut and purpusly made bolt of 10mm dia MS round bar threaded on both the end . Note:-(i) Section Number given above are of make Jindal, Contractor may use similar section of other make mention in Appx B.
S&F 150 mm long extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section length of bolts 200mm complete all as specified and directed.
S&F 300 mm long aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
M&L for Preparation of new untreated surfaces of steel of any description , over 10cm in width or girth , not otherwise described and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed
S&F in repair, Galvanised mild steel wire cloth 0.52 to 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staple or tinned tacks including replacing of wooden beads, if broken/damage, or in steel window complete all as specified and as directed.
Hacking out old broken glass ( any thickness ,size,quality or description) from wooden or steel frame work, glazed with oil putty or fixed with wooden beads complete all as specified and directed.
S&F, 3 mm thk sheet glass ordinary quality and galzing with oil putty/wooden/aluminium beads in square n.exc 0.5 sqm each complete all as specified and directed.
S&F of mild steel 300 mm in length sliding door bolts plate type stove enameled black with bright bolt not less than 12 mm dia with and incl a minimum of 06 bolts and nuts , four on bolt plate and two on staple plate,complete all as spd and directed.
S&F mild steel cold rolled" Medium Weight "butt hinges 100 mm in size fixed with screws to wooden frames or with welding to steel frames including all accessories complete all as specified and directed.
S&F for 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels commercial type on both sides complete all as specified and directed.
Demolition of brick work built in Cement mortar complete all as specified and directed.
M&L brick work with sub class 'B' size, straight or curved on plain exc 6m mean radius in cement mortar 1:6 complete all as specified and directed.
S&F in repairs stop valves, cast copper alloy, screwed down high pressure with capastan head screwed both ends 15 mm bore fancy type chromium plated with long shank and cup (concealed type),Complete all as specified and directed.
M&L in repairs for 75mm dia of cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S&F in repairs 32 to 40mm dia PVC waste pipe for wash basin and kitchen sink Complete all as specified and directed.
Dismantling of cast iron drain pipes, nexc 100 mm jointed in cement mortar and taking out of trenches, if required Complete all as specified and directed.
S&F for 100mm dia of cast iron (sand cast pipes) soil, waste and vent pipe in any length with or without ears with cement joints laid and fixed to wall Complete all as specified and directed.
S&F for 100mm dia of cast iron bends (any radius) diminishing pieces or tapers (larger bore measured Complete all as specified and directed.
S&F in repair fancy type 15mm bore bib taps chromium plated long shank with capastain head screwed down, screwed for iron pipe and fixed Complete all as specified and directed.
S&F in repairs for 15mm bore dia of pillar taps fancy type chromium plated screwed down high pressur with or without lettered HOT or cold with long screwed shank and fly nut, screwed for iron pipe Complete all as specified and directed.
Taking down steel tubing 15 mm bore and connections and removal to store complete all as specified and directed.
All as per item No 61 above but 20 mm bore
S & F tubes 15mm dia medium grade galvanised, with all fittings and fixed complete to walls (concealed/ on surface) and ceiling as laid in floor complete all as specified and directed.
All as per item No 63 above but 20 mm bore
M&L for Cutting chases, pinning in Brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and ctting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed.
Dismantling water tanks exc 250 and n'exc 500 ltrs and removing to store complete all as specified and directed.
S&F for 500 ltr capacity of rotational moulded polyethylene tripple layered water storage tanks ( Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm excluding ditto but including brackets including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe all as specified and directed.
S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (padestal pattern) white colour closed pattern including soft closing black seat cover all as specified and directed.
S&F in repair PVC low level flushing cistern 10 ltrs capacity incl PVC float valves, PVC connection and out let pipes complete.
S&F 32 mm dia Waste coupling of PTMT (half or full threaded) .(Minimum weight 32mm- 45gms/40mm-60 gms) all as specified and as directed.
S&F 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms) all as specified and as directed.
Material and labour for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 complete all as specified and directed.
Demolition of reinforced cement concrete in roof floor (other than ground floors) beams staircase, landing chajja and similiae work complete all as specified.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in chajjas and the like, all as specified and directed by Engr-in-charge.
Use and waste of formwork to soffits of suspended slab such as chajja slab landing and similar work not exceeding 200mm thick surface horizontal or sloping, fair finished surface of concrete all as specified.
M&L TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality all as specified and directed.
M&L TMT bars 6mm dia & 8mm,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality all as specified and directed.
M&L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sqm of vertical surface of the sub structure to a depth of 300 mm including excavating channel along the wall land rodding etc. complete all as specified and directed
M&L for treatment of soil under existing floors using emulsion @ 1L per hole, 300 mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and directed.
M&L for antitermite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @0.5 L/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, buzzer, socket or power & AC Points) complete, including fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets, light fitting etc. removing materials to store for keeping safe custody or for taking credit and making good disturbed surfaces of walls, floors etc as per existing complete
M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC surface conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories,GI metal flush box of 1.60 mm thick suitable for modular/conventional P/switches/sockets/fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :-
(a) One light point/ceiling fan/exhaust fan/bell/buzzer point/socket outlet on independent board controlled by one one way switch
(b) One 5 Amps 3/5 pin socket outlet on same board with other switches.
All as per serial item No 85 above but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board with 1.5 Sqmm nominal cross sectional area copper conductor cable as continuous earth wire (colour green)
S&F Switch piano flush type 5/6 Amps single pole one way
S&F Socket Outlet 2 in 1, 3 pin 5 Amps flush type
S&F Switch piano flush type 15/16 Amps, single pole one way
S&F Socket Outlet 2 in 1 3/6 pin 5 and 15 Amp flush type
S&F electronic fan step regulator fiush type 120 watt, 230 Volt complete
S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
S&F modular switch 6 Amps, one way, one module 240 volts complete
S&F modular socket, 3 pin 6 Amps, 240 volts, 2 module complete
S&F modular switch 16 A, 1 module, 240 volts complete
S&F modular socket 6/16 A, 5 pin, 2 module, 240 volts complete
S&F modular fan regulator, step type, 120 W, humfree, AC, 230 volts, 2 module complete
S&F modular Bell push 6 Amps, one module 240 volts complete
S&F ding dong bell, AC, 230 volts, single pole complete
Taking down ceiling/exhaust fan any make from ceiling carefully, cleaning to remove any type of sticky dust with cleaning material as required and re-fixing in its original position with necessary connection after repairing, greasing, oiling, replacement of minor items such as pins, nut bolts, flexible wire etc incl spray painting in white colour complete.
S&F ceiling fan complete with three blades, down rod, accessories 230 V, 1200mm sweep, min air delivery 210 CFM, BEE 5 star rated with bushless direct current motor and old/unsv fan to be deposited in E/M store yard complete.
S&F heavy duty exhaust fan AC single phase 230/240 V of size 300mm sweep, with louver incl cutting of hole at wall of required size and making good disturbed surface complete all as directed
Taking down existing light fitting any type/wattage carefully and refixing at wall/ ceiling after re-wiring at desired/ directed location incl connection complete all as directed
S&F on wall LED batten lighting fixture 20 watts LED 5700K (4'), with extruded aluminium heat sink, integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as directed
S&F in repair energy saving security light fitting of 35 watts LED pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete.
M&L in repair for two single core (submain) PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 25 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete
All as per above item No 106 but with 6 sqmm and 6 sqmm as earth wire.
S&F in repair sheet metal enclosure flush type, Single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB with 20 Amps complete
S&F in repair Sheet metal enclosure DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, IP-43, and making good to the disturbed surface complete for the following No of ways :-
S&F in repair MCB loadline distribution box 4 way, AC, TP & neutral metal enclosure, glazed double door, 415 V, AC, IP-43, factory made internally prewired, concealed type with IP-43 protection complete with suitable bus bar, neutral link, earth link suitable for upto MCCB 125 Amps, 4 Pole as incomer and MCB SP as out going complete all as directed (Note : MCCB and MCB SP will be measured & paid seperately)
S&F MCCB 4 pole, 100 amps, 415 volt, AC, fixed type with breaking capacity 16 KA suitable for load line DB incl connection complete
S&Fof MCB SP 6 to 40 amps, 240 Volts, 10 KA breaking capacity 'C' curve incl connection complete
S&F of MCB SPN 40 amps, 240 Volts of 10 KA breaking capacity 'C' curve incl connection complete
M&L for earthing with Galvanised Steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI wire of size 4mm dia as earthing lead (upto the body of the equipment) by means of GI bolts, nuts, check nuts and washers and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete
M/S SHARMA ASSOCIATES
BEHAL TRADERS
shiva enterprises
M/s SAAR ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .