Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 0 S F ENTERPRISES CHANDAK CHANDAK POONCH POONCH JAMMU KASHMIR 185101 UDYAM JK 14 0008974 | POONCH | JAMMU AND KASHMIR | 185101 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 245 2 RAJPUR ROAD OPPOSITE HOTEL MADHUBAN DEHRADUN | Admitted-Finance |
Tender Value
₹5,000
EMD Value
₹5.4 L
Closing Date
26 May 2025, 2:00 pmClosed
Superintending Engineer
PDD Choglamsar
same as above
2025_PDNRE_16298_1
e-NIT No. 22 of ED Leh of 2025-26 dated 15-05-2025
Open Tender
Electrical Works
Turn-key
60 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,000
Payable To Executive Engineer EDD Leh
₹5.4 L
3 Jun 2025
15 May 2025
27 May 2025
15 May 2025
26 May 2025
16 May 2025
Amount
DT (Supply Part)
250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
200 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
63 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 200 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (200KVA) and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp (63/100/250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 100Amp and suitable MCCBs for outgoing circuits with terminal extensions
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, jumper binding Tape
Transformer Fencing
Installation/Testing/Commissioning Part)
250 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
200 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
63 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, (Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) , and with LV Cable Box having detachable Aluminium Gland plate
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 25/63/100KVA & 250KVA DTs
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
LT Distribution Box for 250 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 200 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 340Amp (200KVA) and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 100 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 140Amp (63/100/250KVA) and suitable MCCBs for outgoing circuits with terminal extensions
LT Distribution Box for 63 kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 100Amp and suitable MCCBs for outgoing circuits with terminal extensions
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards.5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, jumper binding Tape
Transformer Fencing
HT Line (Supply)
11 Mtr. Long Pole( ST-410 SP56)
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
30 mm² ACSR Conductor
Supply of GI Channel X-arm 1600mm long including clamps and braces (75X40X6mm GI Channel of 1600mm long=40 No.(weight per channel=11.42Kg,back clamp for cantiliver 50X8mm, 365mm long =1.15Kg Total weight=12.57Kg/channel +clamp GI angle 65XiX6mm, 1760mm long =40 nos (weight=10.21Kg, Guy clamp for cantiliver 50X8mm,300mm long=.9Kg, Total weight=11.11Kg Total weight of X-arm and cantiliver=23.68Kg
GI Channel X-arm including clamps and Braces for DP (80Kg/DP)
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards 0.6cum /pole
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11KV Link Set
HT Line (Installation/Testing/Commissioning Part)
11 Mtr. Long Pole( ST-410 SP56)
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp(14.631 kg/complete V-set)
30 mm² ACSR Conductor
GI Channel X-arm 1600mm long including clamps and braces (75X40X6mm GI Channel of 1600mm long=40 No.(weight per channel=11.42Kg,back clamp for cantiliver 50X8mm, 365mm long =1.15Kg Total weight=12.57Kg/channel +clamp GI angle 65XiX6mm, 1760mm long =40 nos (weight=10.21Kg, Guy clamp for cantiliver 50X8mm,300mm long=.9Kg, Total weight=11.11Kg Total weight of X-arm and cantiliver=23.68Kg
GI Channel X-arm including clamps and Braces for DP (80Kg/DP)
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards 0.6cum /pole
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11KV Link Set
LT Line (Supply)
8 Mtr. Long Pole( ST-410 SP15)
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
30mm² ACSR Conductor
50mm² ACSR Conductor
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Eye Hook with clamp set
Suspension Clamp
Tension Clamp
50sqmm LT AB Cable (3x120+1x16+1x70sqmm) XLPE (1.1KV, 3+1C, AL)
35sqmm 1-Core Cable, 1.1KV Grade XLPE unarmoured FRLS Type
IPC Connectors
SMDB Box
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
LT Line (Installation/Testing/Commissioning Part)
8 Mtr. Long Pole( ST-410 SP15)
GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=4Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg)
GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg)
30mm² ACSR Conductor
50mm² ACSR Conductor
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Eye Hook with clamp set
Suspension Clamp
Tension Clamp
50sqmm LT AB Cable (3x120+1x16+1x70sqmm) XLPE (1.1KV, 3+1C, AL)
35sqmm 1-Core Cable, 1.1KV Grade XLPE unarmoured FRLS Type
IPC Connectors
SMDB Box
Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
MODERN ELECTRIC CO (BID ID -158222)
M/S VEENA CONSTRUCTION COMPANY (BID ID -158371)
TL CONSTUCTION COMPANY (BID ID -158356)
M/S CHHEIRPON ENTERPRISES (BID ID -158328)
DRUK ELECTRICALS (BID ID -158325)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .