Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC AT JANTA NAGAR BOKARO THERMAL DIST BOKARO PIN 829107 | BOKARO | JHARKHAND | 829107 | ₹3.2 L | L1 | Accepted-AOC BIDDER IS L1 AND RECOMMENDED BY TC AND APPROVED BY COMPETENT AUTHORITY |
| 2 | Rejected-Technical | - | - | Rejected-Technical Documents examined and is NOT as per NIT. Bid rejected. |
| 3 | Rejected-Technical 116 PRINTKRAFT FRONT PORTION OF 1ST FLOOR 116 B BLOCK ROAD SECTOR 65 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | - | - | Rejected-Technical Documents examined and is NOT as per NIT. Bid rejected. |
| 4 | Rejected-Technical 00 KALU KUWAN BANDA BANDA UTTAR PRADESH 210001 | BANDA | UTTAR PRADESH | 210001 | - | - | Rejected-Technical Documents examined and is NOT as per NIT. Bid rejected. |
| Sl No | Description | Qty | Unit | M/S SINGH ENTERPRISES L1 |
|---|---|---|---|---|
| 1.01 | Providing and fixing of digital water flow meter of size 200mm of following specification :-1 Flow meter shall have trans receiver type probes working on transit time principle of correlation of ultrasound. 2. It is ultrasonic flow meter and flow meter body shall be PTEE coated to make it acidic water resistant. 3. Digital dispaly 4. Data Logging-1440 Hourly logs, 460 daily logs and 48 monthly logs 5. RS485 (modbus) shall be provided for communication with computer system. 6. Ingress protection. 7. Battery operated. 8. Display parameter shall be flow rate, totalizers-net total forward and reverse, no. of hours since water meter installed and run hours 9. Accuracy- of water meter shall be as per ISO 4064 class B 10. Range ability ; 1:125 OLML, MID and ISO 9008 certified, 11. Output : Modbus RS485 pluse. | 1 | set | 79,850 ₹79,850 Lowest |
| 1.02 | Providing and fixing of digital water flow meter of size 150mm of following specification :-1 Flow meter shall have trans receiver type probes working on transit time principle of correlation of ultrasound. 2. It is ultrasonic flow meter and flow meter body shall be PTEE coated to make it acidic water resistant. 3. Digital dispaly 4. Data Logging-1440 Hourly logs, 460 daily logs and 48 monthly logs 5. RS485 (modbus) shall be provided for communication with computer system. 6. Ingress protection. 7. Battery operated. 8. Display parameter shall be flow rate, totalizers-net total forward and reverse, no. of hours since water meter installed and run hours 9. Accuracy- of water meter shall be as per ISO 4064 class B 10. Range ability ; 1:125 OLML, MID and ISO 9008 certified, 11. Output : Modbus RS485 pluse. | 1 | set | 70,900 ₹70,900 Lowest |
| 1.03 | Cutting of two sides of 8 inch dia. G.I./MS pipe for making two nos. of short pieces (2 x 24.30”) x 2 nos. | 97.2 | inch | 12 ₹1,166.4 Lowest |
| 1.04 | Cutting of two sides of 6 inch dia. G.I./MS pipe for making two nos. of short pieces (2 x 20.42”) x 2 nos. | 81.68 | inch | 12 ₹980.16 Lowest |
| 1.05 | Welding of 02 nos. 08 inch dia. G.I./MS flange of 02 nos. of G.I. short pieces (inner dia. and out dia. welding) (2x2x24.30”) x 02 nos. | 194.4 | inch | 14.68 ₹2,853.79 Lowest |
| 1.06 | Welding of 02 nos. 06 inch dia. G.I./MS flange of 02 nos. of G.I. short pieces (inner dia. and out dia. welding) (2x2x20.42”) x 02 nos. | 163.36 | inch | 14.68 ₹2,398.12 Lowest |
| 1.07 | Supply of flange 08” dia. (type-table D) | 2 | no | 1,205 ₹2,410 Lowest |
| 1.08 | Supply of flange 06” dia. (type-table D) | 2 | no | 980 ₹1,960 Lowest |
| 1.09 | Supply of M.S. nut, bolts and washers of required size | 20 | kg | 120 ₹2,400 Lowest |
| 1.10 | Supply of rubber packing of 08” dia. | 2 | no | 125 ₹250 Lowest |
Tender Value
₹3.3 L
EMD Value
₹4,100
Closing Date
21 Mar 2025, 9:00 amClosed
PE EnM
PO OFFICE, BOKARO COLLIERY
Installation testing and commissioning of 150 mm and 200 mm diameter digital flow meters with telemetry units at bokaro colliery
2025_CCL_332186_6
CCL/BnK/Bokaro/EnM/24-25/12
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Bokaro colliery
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,100
15 May 2026
11 Mar 2025
22 Mar 2025
12 Mar 2025
21 Mar 2025
12 Mar 2025
12 Mar 2025 - 18 Mar 2025
Amount
Providing and fixing of digital water flow meter of size 200mm of following specification :-1 Flow meter shall have trans receiver type probes working on transit time principle of correlation of ultrasound. 2. It is ultrasonic flow meter and flow meter body shall be PTEE coated to make it acidic water resistant. 3. Digital dispaly 4. Data Logging-1440 Hourly logs, 460 daily logs and 48 monthly logs 5. RS485 (modbus) shall be provided for communication with computer system. 6. Ingress protection. 7. Battery operated. 8. Display parameter shall be flow rate, totalizers-net total forward and reverse, no. of hours since water meter installed and run hours 9. Accuracy- of water meter shall be as per ISO 4064 class B 10. Range ability ; 1:125 OLML, MID and ISO 9008 certified, 11. Output : Modbus RS485 pluse.
Providing and fixing of digital water flow meter of size 150mm of following specification :-1 Flow meter shall have trans receiver type probes working on transit time principle of correlation of ultrasound. 2. It is ultrasonic flow meter and flow meter body shall be PTEE coated to make it acidic water resistant. 3. Digital dispaly 4. Data Logging-1440 Hourly logs, 460 daily logs and 48 monthly logs 5. RS485 (modbus) shall be provided for communication with computer system. 6. Ingress protection. 7. Battery operated. 8. Display parameter shall be flow rate, totalizers-net total forward and reverse, no. of hours since water meter installed and run hours 9. Accuracy- of water meter shall be as per ISO 4064 class B 10. Range ability ; 1:125 OLML, MID and ISO 9008 certified, 11. Output : Modbus RS485 pluse.
Cutting of two sides of 8 inch dia. G.I./MS pipe for making two nos. of short pieces (2 x 24.30”) x 2 nos.
Cutting of two sides of 6 inch dia. G.I./MS pipe for making two nos. of short pieces (2 x 20.42”) x 2 nos.
Welding of 02 nos. 08 inch dia. G.I./MS flange of 02 nos. of G.I. short pieces (inner dia. and out dia. welding) (2x2x24.30”) x 02 nos.
Welding of 02 nos. 06 inch dia. G.I./MS flange of 02 nos. of G.I. short pieces (inner dia. and out dia. welding) (2x2x20.42”) x 02 nos.
Supply of flange 08” dia. (type-table D)
Supply of flange 06” dia. (type-table D)
Supply of M.S. nut, bolts and washers of required size
Supply of rubber packing of 08” dia.
Supply of rubber packing of 06” dia.
Telimetery connected with in built sim connection complete set.
All items installation, commissioning and testing with twin core copper cable, switches, pin socket and top for line 220-V with modular board power supply of the digital water flow meter and telemetery set in the existing pipe line at site.
Providing, fabricating of folding type and movable guard/cover assly. M.S. sheet, angle and grill for protection of flowmeter and telimetery.
Complete repairing, reconditioning and overhauling of old & damaged deigital flow meter with digital card replacement, fitting, fixing and testing of complete assly. of digital flow meter. 150mm dia.
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.18 MB
BOQ_344377.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .