Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Ok | |
| 2 | L2₹39.8 L+₹53,960 (1.37%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Other than Lowest tenderer | |
| 3 | L3₹46.3 L+₹7.0 L (17.8%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance Other than Lowest tenderer |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
10 Dec 2022, 6:00 pmClosed
GE (E/M) BASE HOSP DELHI CANTT
GE (E/M) BASE HOSP DELHI CANTT-110010
REPAIR/ MAINT OF E/M INSTALLATIONS AND CERTAIN CONNECTED MISC E/M WORKS AT DR SR KVS AUDITORIUM UNDER GE (E/M) BASE HOSPITAL DELHI CANTT-10
2022_MES_562263_1
GE/BH-82/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (E/M) BASE HOSP DELHI CANTT
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE (E/M) BASE HOSP DELHI CANTT
₹99,800
Yes
2 Feb 2023
12 Nov 2022
12 Dec 2022
12 Nov 2022
10 Dec 2022
26 Nov 2022
Amount
S&F in replacement switch piano, flush button type, single pole, one way 5 Amps switch complete all as specified and directed.
S&F in replacement switch piano, flush button type, single pole, one way 15 Amps switch complete all as specified and directed.
S&F in replacement socket outlet 3 pin 5 Amps, flush type complete all as specified and directed.
All as per Ser item No 3 here in before but socket 15 Amps complete all as specified and directed.
S&F in replacement modular switch piano flush button type, single pole, one way, 10 Amps, one module complete all as specified as directed.
All as per Ser item No 5 here in before but 20 Amps, two module complete all as specified as directed.
S&F in replacement modular socket outlet 3 pin and 2 pin, 10 Amps, two module complete all as specified as directed.
All as per Ser item No 7 here-in-before but 20 Amps, two module complete all as specified as directed.
M&L in replacement single core copper conductor, FRLS, PVC insulated unsheathed 1100 Volt grade flexible 1.5 Sqmm copper conductor drawn through concealed rigid PVC conduit complete all as specified and directed.
All as per Ser item No 9 here in before but 2.5 Sqmm complete all as specified and directed.
All as per Ser item No 9 here in before but 4 Sqmm complete all as specified and directed.
All as per Ser item No 9 here in before but 6 Sqmm complete all as specified and directed.
M&L for sub main wiring with 2 runs of 4.0 sqmm single core, PVC insulated & unsheathed (FR) cable 1100 Volts grade with multi stranded, copper conductor drawn through concealed conduit including PVC rigid conduit medium grade as per ISS and one run of 4 sqmm size PVC insulated copper conductor complete all as specified and directed. (Note: Two run of cable and earth conductor with conduit shall be measured as one length)
S&F in replacement MCB SP 6-32 Amps, 240 Volts, complete all as specified and directed.
S&F in replacement MCB TP 25-63 Amps, 415 Volts, complete all as specified and directed.
S&F in replacement MCB TPN 40-100 Amps, 415 Volts, complete all as specified and directed.
S&F in replacement Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps complete all as specified and directed.
Taking down unserviceable HPSV Lamp street light from the existing pole and Repair/Replacement of HPSV Lamp 150 watts complete ass as specified and directed. Make: Philips/CG/Havells
S & F in replacement of open copper Wound Ballast of capacity 150 watts 230 volts, 50 Hz for HPSV Light fitting complete all as specified and directed. Make: Philips/ CG/Havells
S&F in replacement starter 18/20 W, 110 V/220 V for FTL fittings and ceiling fittings complete all as specified and directed. Make- Philips/ Havells/ CG.
S&F in replacement starter 36/40 W 110 V/220 V for FTL fittings and ceiling fittings complete all as specified and directed. Make- Philips/ Havells/ CG.
S&F in replacement Fluorescent tube rod 20 W complete all as specified and directed. Make - Philips/ Bajaj/ Surya
S&F in replacement Fluorescent tube rod 36 W, super bright type complete all as specified and directed. Make - Philips/ Bajaj/ Surya
S&F in replacement FTL Electronic ballast, 240V, 18/20/36/40W complete all as per specified and directed. Make- Havells/CG/Legrand
Supply and fixing PVC electric tape of size 20mm, 20 mtr length complete all as specified and directed. Make-Steel grip/ 3 M/Kalinga
S&F in replacement Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
S & F in replacement electronic ignitor suitable for HPSV Light fitting 150 watts complete all as specified. Make: Philips/CG/Havells
S & F in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd.
Taking down the ceiling fans/exhaust fan/wall fan of any make & sizes, carrying out minor repairs such as greasing, oiling, fitting, testing complete all as directed and required at site and hanging to its existing position after minor repair of any size and make and connecting complete all as specified and directed.
M&L in replacement bearing No 6200/6201/6203/6204 for ceiling fans/ exhaust fan of any make & size for proper running and testing complete all as specified and directed.
M&L in replacement bush of ceiling fans/ pedestal fan/ wall fan any make & size for proper running and testing complete all as specified and directed.
M&L in replacement capacitor of 3.15 MFD or existing type capacitor complete all as specified and directed. Make- Epcos/Asian/Tiscon
M&L for disconnecting and repair and re-winding the electric motor by disconnecting the electric connection, removing bolts and nuts carrying the motor of exhaust fan, single phase, 240 Volts complete all as specified and directed.
Taking down carefully defective existing Miniature fluorescent lamp/CFL/LED Bulb down light fitting by unscrewing from high bay (false ceiling height up to 60 feet) down to floor, dismantling and supply & Fixing new Round type 18W LED light fitting, white colour light complete with electrical connection, making good the disturbed surfaces of walls, ceiling etc complete all as specified and directed. Make- Havells Cat part No. EDGEPRORDDLR18WLED857S or equivalent Model of Philips/WIPRO. Note: The contractor shall arrange his own Ladders/Elevators for taking down & fixing of Light fitting & electric wiring up to 60 feet heights and nothing extra shall be admissible on this account.
Taking down existing spot down light or existing fluorescent lamp/CFL/LED Bulb and supply and fixing in replacement new Round type LED Light of 5/6 Watt with complete fittings, retrofit, white in colour, circular recess, dia 75 mm fitted in existing cutting grooves of the ceiling as per site requirement without disturbing the ceiling up to 60ft height complete all as specified and directed. Make- Havells Cat part No- . EDGEPRORDDLR6WLED857S or equivalent Model of Philips/WIPRO. Note: The contractor shall arrange his own Ladders/Elevators for taking down & fixing of Light fitting & electric wiring up to 60 feet heights and nothing extra shall be admissible on this account.
S & F in replacement Luminaries round smart slim LED Panel with round recess white colour LED lamp 12W, 220 V & 50 Hz including necessary electrical connection complete as per sample at site and directed. Make- Havells Cat part No- EDGEPRORDDLR12WLED857S or equivalent Model of Philips/WIPRO.
S & F in replacement LED type based chair lights complete fittings as per sample at site complete all as specified and directed. Make- Rana Chairs/ Havells/ Bajaj/ Philips
Taking down the unserviceable strip light and refixing the same Strip lights of size 4/5 ft/ required at site, after repair at site including replacement of PCB plate, connector, LED, upper case, wiring and testing complete all as specified and directed.
S&F Emergency Exit light with electronic ballast, LED driver, battery charger, battery, diffuser, LED board etc. for emergency door complete all as specified and directed..
M&L for repairing of Main Stage curtain mechanism including replacement of necessary items of stage curtain for front and back stage, curtain cloth stitching, flaps including replacement/repairing of stage operating motor, stage motor pulley, motor pulley steel rope, stage light bars including gear box repairing and replacement of MCBs and DBS of matching specifications, relay, contactor and also replacement of existing GI made master certain rail, 20 metre long at 40 feet height including making the system functional complete all specified and directed.
Taking down curtains from auditorium stage (height up to 30 ft) and refixing at existing position after dry cleaning of curtains including necessary stitching and I-let complete all as specified and directed.
M&L for disconnecting and repair and re-winding the electric motor by disconnecting the electric connection, de-coupling motor and pump, removing foundation bolts and nuts carrying the motor 75 HP for fire fighting, 3 phase, 415 Volts to workshop and carried out the following repair & rewinding work complete all as specified and directed:- Note:- (i) Cutting the complete burnt and defective winding after opening body cover and separate starter and rotors. (ii) Cleaning the starter body complete by rubbing sand paper remove all carbon. (iii) Insert insulating materials such as insulating paper sleeves varnish. (iv) Replacement of ball bearings as per size required (v) Re-winding the stator with existing size and quantity of super enamelled copper winding wire. (vi) Clean the rotor, re-assemble the motor 7 coupling and re-connection electric connections & earth connection and making the system functional and testing on full load complete all as specified and directed.
All as per Srl item No 42 here in before but 15 HP for AHU blower motor complete all as specified and directed.
All as per Srl item No 42 here in before but 15 HP for terrace fire pump complete all as specified and directed.
All as per Srl item No 42 here in before but 15 HP for condenser water pump/ chiller water supply of Central AC plant complete all as specified and directed.
All as per Srl item No 42 here in before but 12.5 HP for Water supply complete all as specified and directed.
All as per Srl item No 42 here in before but 10 HP for Jockey fire pump complete all as specified and directed.
All as per Srl item No 42 here in before but 5 HP for Cooling tower pump complete all as specified and directed.
M&L for complete servicing, greasing, oiling, filling of glands various type of pump/ blower/ motor of 75 HP capacity including replacement of unserviceable nut, bolts complete all as specified and as directed.
All as per Srl item No 49 here in before but 15 HP for AHU's.
All as per Srl item No 49 here in before but 15 HP for terrace Fire pump & condensor/ chilled water pumps.
All as per Srl item No 49 here in before but 12.5 HP.
All as per Srl item No 49 here in before but 10 HP.
All as per Srl item No 49 here in before but 5 HP.
Taking down old unserviceable condensor water pump/ chiller water pump/ domestic water supply pump of head range-32.00 to 50.00 M, 2880 RPM, 15 LPS, decoupling motor and pump including removing electrical & water connections complete , disconnected from foundation by removing nut bolts, and repairing/replacement necessary parts i.e. impeller, casing, bearings, foundation vibration pads etc and refixing same after repair from authorised workshop including transportation, tightening nut bolt, greasing at necessary parts, making connection water and electrical, etc. including testing and commissioning complete all as specified and directed.
S & F in replacement of GI wire 4.0 mm dia with saddle and screw for earthing complete all as specified and directed.
Taking out defective submersible pump set from bore well by help of tripod chain pulley, disconnecting electrical connection, taking out all column pipe from bore well & dismantling column pipe from pump set of capacity 5 HP and repairing the same, including replacement of bearing, impeller, etc, rewinding of submersible motor with PVC insulated copper winding wire of existing gauge after removing the old wire & insulated material, clearing of stator slots & making good for winding all insulating material for submersible pump set of 5 HP, including transporting to authorised workshop and testing of pump set including lowering of column pipe along with submersible pump set complete all as specified and as directed.
S & F in replacement 100 mm CI Foot Valve complete all as specified and directed.
Supply, laying & testing in replacement PVC insulated, and FR PVC flate sheathed, copper conductor (flexible) cables of size 2.5 sq mm ,3 core, 1100 Volts grade complete all as specified and directed.
S&F in repair LED street light fitting 120 Watt 230 Volt AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistance including thermal management in multiple optics complete with IP 65/66 protection complete.
M&L for cleaning the old painted surfaces by scraping with scrap paper, sand paper and applying two coat of synthetic Enamel paint of colour required at site on street light poles complete all as specified and directed.
M&L for KOISK box made out of 6 guage CRCA sheet size 200X160X98 mm with covered locking arrangement incl Bus Bar TPN 32 Amp with sure link protection 6 Amp -01 and having fixing arrangement made of F I clamp 25X3 mm on pole with nut and bolt and washers and painting over coat of red oxide complete all as specified and directed.
Taking down the fire extinguisher from its existing position and supply/ refilling the multipurpose A/BC/ABC stored type CEASE FIRE powder type, fire extinguisher of capacity 2 Kg and refixing in old position including complete denting/painting/ new sticker with testing from authorised dealer complete all as specified and directed. Note- contactor shall provide testing certificate of filling fire extinguisher after filling from authentic dealer of fire extinguisher.
All as per Ser item No 63 here-in-before but capacity 5 Kg complete all as specified and directed.
All as per Ser item No 63 here-in-before but capacity 10 Kg complete all as specified and directed.
All as per Ser item No 63 here-in-before but capacity 15 Kg complete all as specified and directed.
M & L for cleaning the old painted surfaces by scraping with scrap paper, sand paper and applying two coat of synthetic Enamel paint of required colour as per site on fire hydrant pipe, Hose box, hose reel, fire alarm control panel, fire bde inlet with connected items and central AC plant connected items i.e pipe line 100/125/150/200 mm size, valve, etc complete all as specified and directed.
Taking down old unserviceable fire hose boxes any type any size form wall, disconnecting form hydrant pipe and all connection and fixing new hose boxes of MS sheet of 18 gauge, suitable size as per site requirement, making good surface & connection complete all as specified and directed.
S&F in replacement of MS ERW pipe 150mm NB heavy duty ,duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth in soft/ loose soil and getting out for laying of pipe ,underground cables and foundation for poles, shaft, wells, cesspit, manhole, pier holes etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed.
M&L for removing excavated materials not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 with 20 mm graded stone aggregate for making base of air cushion tank stand at terrace or any work present at site including necessary from work, fair finishing to exposed surfaces using extra cements complete all as specified and directed.
Supply and fix in replacement Pressure gauge 100 mm dia with ball valve of pressure 10.5 Kg/Sqcm complete all as specified and directed.
M&L for servicing of voltage stabilizer 2.0/3.0 KVA Cap, complete cleaning with Chemical regent including replacement of necessary equipment/ items complete all as specified & directed.
S & F in replacement of 3 pin plug top 5/ 15A complete all as specified and directed.
M & L for repairing and Servicing of 10 KVA UPS including replacement of UPS control card, display card, and LCD display set & repair UPS system as per requirement complete all as specified and directed.
S & F in replacement of type SMF battery of cap 42AH/12V, warranty should be at least 24 months complete all as specified and directed. Make : Exide/ Amron/ Luminous
S & F in repair rotational moulded polyethylene, triple layer food grade plastic water storage tank of capacity 5000 ltr (cylindrical, vertical, with closed top) hoisted and fixed in position, including complete connection of inlet and out let pipe, tank nipple, float valve fixing of GI pipe (over flow) etc as per site requirement complete all as specified and directed.
S & F in replacement 50 mm bore Gun metal gate valve with brass spindle & iron wheel complete all as specified & directed.
All as per Srl item No 80 here-in-before but 25 mm complete all as specified & directed.
All as per Srl item No 80 here-in-before but 20 mm complete all as specified & directed.
All as per Srl item No 80 here-in-before but 15 mm complete all as specified & directed.
Supply laying and testing in replacement 20 mm bore GI water tubing, medium grade, with all fittings, with screwed and socketed joints and fixed complete to wall, ceiling or laid in floor etc. and making good the disturbed surface complete all as specified and directed.
All as per Srl item No 84 here-in-before but 15mm bore complete all as specified and directed.
M&L in replacement PVC float valve complete with EPOXY coated Aluminium rod and HD Ball of size 40 mm bore complete all as specified and directed.
M&L in replacement PVC float valve complete with EPOXY coated Aluminium rod and HD Ball of size 25 mm bore complete all as specified and directed.
M&L in replacement PVC float valve complete with EPOXY coated Aluminium rod and HD Ball of size 20 mm bore complete all as specified and directed.
S & F in replacement of ACB 3 Pole, 415 V, with microprocessor based (Manual Drawout type) of capacity 1000 Amps 50 KA, complete all as specified and directed.
S & F in replacement of MCCB 4 Pole, 415 V, with microprocessor release based of capacity 800 Amps 50 KA, complete all as specified and directed.
S&F in replacement MCCB 3 pole, 415 Volt, fixed type, 25 Amp to 100 Amp, with 16 KA breaking capacity complete all as specified & directed.
S&F in replacement MCCB 3 pole, 415 Volt, adjustable type, 250 Amps, with 36 KA breaking capacity complete all as specified & directed.
S&F in replacement 3 pole power contactor type ML-6, 60 Amps rated capacity, 50 cycles, 220/240 volts including Incoming & outgoing wiring with copper conductor of 10 sq mm size with suitable copper lugs and taking down the existing unserviceable one complete all as per specified and directed.
All as per Srl item No 93 here in before but ML-4 type complete all as specified and directed.
All as per Srl item No 93 here in before but ML-1.5 type complete all as specified and directed.
S & F in replacement power contactor MNX type 18/25 or as per site requirement complete all as specified and as directed.
M&L for servicing, cleaning, oiling , greasing, preventive & periodical maintenance including checking electrical connection & control wiring of DG set 630 KVA, Make-Kirloskar installed at KV-2 Auditorium including replacement of minor parts with testing and commissioning etc complete all as specified and directed. Note:- (i) Major Spares parts and oil shall be measured and paid separately under respective item of this BoQ as Supply only. (ii) Any other minor items required for overhauling except described here-in-after shall be supplied by the contractor with out any extra cost to the deptt and the rates for the same shall deemed to be included in the quoted rates. (iii) Servicing shall be done through authorized service centre of Kirloskar
Supply only engine wiring harness assembly complete all as specified and directed.
Supply only PCB of starter panel complete all as specified and directed.
Supply only coolant level indicator complete all as specified and directed.
Supply only Lube oil filter cartridge complete all as specified and directed.
Supply only Air cleaner primary element complete all as specified and directed.
Supply only Air cleaner safety element complete all as specified and directed.
Supply only Fuel filter assembly complete all as specified and directed.
Supply only Fuel pre filter assembly complete all as specified and directed.
Supply only Greaves lube oil 20 ltr pack complete all as specified and directed.
Supply only Greaves lube oil 10 ltr pack complete all as specified and directed.
Supply only Radiator pre-mixer greaves kool 10 ltr complete all as specified and directed.
Supply only Battery exide-180AH complete all as specified and directed.
Supply only Charge towards fuel tank cleaning complete all as specified and directed.
M&L for complete servicing of cooling tower of 100 TR AC plant installed at KV No.2 auditorium including cleaning, welding, painting and applying the suitable chemical, removing all the deposited dust, foreign material, cleaning of filter and Checking electric connection of CT fan motor, sprinkler and PVC arms coating of FRP compound for filling of its tray joint and remove its leakage with testing, commissioning etc. complete all as specified and directed. Make: DELTA/POLO Note:- The major parts to be replaced shall be measured and paid separately as supply only under respective item of this BoQ.
Supply only PVC fills 600 x 300 x 150 mm double folded complete all as specified and directed.
Supply only Fan assembly 1500 mm complete all as specified and directed.
Supply only SS Sprinkler 5'' complete all as specified and directed.
Supply only Tie Rod & Turn Buckle (04 Nos) complete all as specified and directed.
Supply only FRP Eliminator (04 Nos) complete all as specified and directed.
Supply only PVC Eliminator 3'' complete all as specified and directed.
Supply only FRP compound for basin repair complete all as specified and directed.
M & L for dehydration of transformer oil of 630 KVA transformer including filtration by dehydration machine including testing of sample of oil before and after dehydration and filtration, cleaning of transformer, tightening of nut bolt of HT/LT side of transformer, changing of silica gel with breather of suitable size including bend pipe, and cleaning at site after dehydration complete all as specified and directed. Note: Dehydration of transformer to be done by authorised service center as per existing make of transformer.
Supply and filling new transformer oil, low viscosity type, confirming to IS-335 for topping up/ replacement wherever required complete all as specified and directed.
S&F in repair power supply controller , DC 24 Volt in control room for connecting chair light complete all as specified and as directed .
M & L for coated hot rolled fibreglass roof sheet of thickness at least 4mm for roof covering of terrace fire pump fixed with proper nut and bolt complete all as specified and directed.
S & F in replacement Strip light of length 4/5 feet as per sample at site complete all as per specified and directed. Make-Plainton or equivalent
M & L for testing of complete fire detection system in and outside Auditorium Building on quarterly basis complete all as specified and directed. Note:- Complete testing shall be done through OEM of Fire Detection system installed at site.
M & L for repairing/servicing of complete existing fire alarm control panel system with multiplex system for 16 zone by checking its proper functioning and replacing defected smoke detectors and control cable at various locations as per site requirement including battery backup system including connection as required at site complete all as specified and as directed. control cable and detectors shall be paid respective item of this schedule. Note: Work shall be executed through OEM at 60 feet height.
S & F in replacement smoke detector with fittings complete all as specified and directed. Note: Work shall be executed through OEM at 30 feet height.
Supply and lay in replacement of cable, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of Size 10 Sqmm 4 core complete all as specified and directed.
M&L sand filling in and around LT/HT cables 8 cm thick below and 15 cm above the cable respectively after laying the cable and gently punned down all as specified and directed.
Supply and laying old size brick common brunt clay building brick sub class 'B'designation 75 for cable cover.
S & F in replacement of GI pipe of light grade of size 40mm bore with all fitting laid in trenches complete all as specified and directed.
Taking out all air filters from existing AHU of central AC plant of capacity 100 TR, cleaning the cooling coil with suitable chemical and jet of water pressure with pump and remove all the scale and foreign material deposited inside the coil followed with air pressure to sweep up all the particles and ensure thorough flow of air over the cooling coil for existing AHU and refixing the air filter after cleaning complete all as specified and directed.
Taking out the filters of 5 micron type from the cooling coil of AHU, and S&F new filter as per existing specification and size 600 x 600 x 15 mm complete all as specified and as directed.
M&L for replacement of M/c base channel 40X75 of AHU complete all as specified and directed please.
M & L for replacement of AHU Fan Belt of size A80 complete as per sample complete all as per specified and directed. Make: Fenner/ECODRIVE/DUNLOP
M&L for insulation of AHU rooms with resin bonded fibre glass with factory laminated aluminium barrier having thickness of 25 mm including taking down the existing insulation with glass wool and suitable fixing arrangement complete all specified and directed.
M&L in replacement insulation of 25 mm MS pipe with PUF insulation of 30 mm thick and applying bituminous compound and GI cladding with 26 gauge GI sheet including removal of old insulation from site complete all as specified and directed.
All as per Ser item No 133 here-in-before but 40 mm complete all as specified and directed.
All as per Ser item No 133 here-in-before but 50 mm complete all as specified and directed.
Supply, assembly and erection of GI sheet with TDF flange rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as corner, cleat, carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete, size 24 Gauge including complete fixing at wall up to 60 feet heights using clamps & angle iron complete all as specified and directed. Note: Necessary arrangement done by contractor to fixing the duct at height up to 60 feet.
Supply and filling compressor oil (BSL 'C' oil - 5 Gal. Can) suitable for Blue Star compressor of capacity 100 TR with complete all as per specified and directed.
Supply and filling of refrigerant gas R22 including detecting of leakage and rectifying them complete all as specified and directed . Make : Mafron/Rafron
Taking down the compressor and fill up existing refrigerant gas in separate cylinder, disconnecting of electric motor, refrigerant line, gauges pipe, taking out the rotor crank shaft, opening and dismantling of compressor for general overhauling, Mode-l JS 83 F, Make : Blue Star, Capacity- 100 TR, carry out the inspection of compressor, Carry out the general overhauling including replacement of springs, aluminium washer packing, screw, lath work, cleaning with detergent, cotton waste etc and cleaning the suction filter, oil filter, replacing the defective parts, assembling the compressor, testing for leakage with nitrogen gas and rectify them, recharging of refrigerant Gas R-22 & compressor oil and testing the compressor and complete servicing of chiller units along with chiller electrical panel complete all as specified and as directed. Note:- (i) Spares and compressor oil shall be measured and paid separately as supply only under respective item of this BoQ. Supply and charging Refrigerant Gas is included in the rate quoted. (ii) Any other minor items required for overhauling except described here-in-after shall be supplied by the contractor with out any extra cost to the deptt and the rates for the same shall deemed to be included in the quoted rates. Note:- Servicing shall be done through Authorised service centre of Blue Star.
Supply only complete gasket set complete all as specified and directed.
Supply only Loading unloading frame complete all as specified and directed.
Supply only Suction reed complete all as specified and directed.
Supply only Discharge Reed complete all as specified and directed.
Supply only Piston ring complete all as specified and directed.
Supply only Piston complete all as specified and directed.
Supply only Piston Liner complete all as specified and directed.
Supply only Main bearing complete all as specified and directed.
Supply only CR bearing complete all as specified and directed.
Supply only Discharge valve assy complete all as specified and directed.
Supply only Piston pin complete all as specified and directed.
Supply only Connecting rod complete all as specified and directed.
Supply only Suction plate complete all as specified and directed.
Supply only Oil regulating valve complete all as specified and directed.
Supply only Oil filter cartridge complete all as specified and directed.
Supply only Refrigerant suction filter element (Set of 2) complete all as specified and directed.
Supply only Piston Pin Bush complete all as specified and directed.
S&F in replacement outdoor unit complete set, suitable for 1.5 TR split AC of existing make & model, including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed.
S&F in replacement S.S Syphon 1/2" with cork with fitting complete all as specified and directed.
S&F in replacement outdoor unit complete set, suitable for 2.0 TR Split AC of existing make & model, including condenser coil, blower motor, chassis, base plate complete set except compressor complete all as specified & as directed.
S&F in replacement 100 mm dia, 7 Kg/cm2 SS pressure gauge including all fittings complete all as specified and directed. Make: H Guru/Danfoss or equivalent.
S&F in replacement of industrial thermometer as per existing make at site including all fittings complete all as specified and directed.
S&F in replacement of water flow switch as per existing make at site including all fittings complete all as specified and directed.
M&L for cleaning of the surface of duct applying of cold setting CPRX compound on duct , fixing of 25 mm thick thermocol sheet on the duct and wrapping with PVC polythene sheet with help of PVC tape, then fixing of 26 Gauge aluminium sheet cladding by using self threaded SS screw etc as required as per site complete all as specified and as directed.
Supply and fixing in replacement Microprocessor card of 100 Ton Central AC plant of Model : JS83 F York of Make: Blue Star compressor chiller unit, including testing & commissioning etc complete all as specified and as directed.
S&F in replacement hermetically sealed reciprocating compressor including compressor oil, gas charging and testing complete for water cooler of cooling Capacity 150 Litre/Hr complete all as specified and as directed.
S&F in replacement CI butterfly valve, 125mm size, single lever Butterfly valve of size 125 mm dia including cutting, jointing, welding all as per site requirement complete all as specified and as directed.
All as per srl item No 166 above here in before but size 100 mm complete all as specified and as directed.
S&F in replacement of thermal overload relay of range 9-14A suitable for 12.5 HP star delta starter complete all as specified and directed.
S&F in replacement of thermal overload relay of range 14-23A suitable for 15 HP star delta starter complete all as specified and directed.
M&L in repair Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
M&L in repair Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using GI strip as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth in Hard/dense soil and getting out for laying of pipe, underground cables and foundation for poles, shaft, wells, cesspit, manhole, pier holes etc.
M&L in replacement of control cable for connecting of smoke detector, single core copper conductor, FRLS, PVC insulated unsheathed 1100 Volt grade flexible 1.0 Sqmm copper conductor drawn through concealed rigid PVC conduit complete all as specified and directed. Note: Work shall be executed at 60 Feet height.
Providing, fixing, testing and commissioning of 8 Zone, fire alarm control panel for Manual call box, power card rectifier relay for actuation of hooter on respective floor, adjustable timer, sealed maint free battery 15 AH 24 Volts capable of running minimum of 12 hours with battery charger. LED indicators for fire signal of individual unit. Each floor shall have a separate relay for actuation of sounder. through tone generator and PA panel. Panel shall also be provided with key operated auto dialer and connection to P&T lines with 4 auto programmed into the panel complete all as specified and as directed.
Supply only in replacement of AHU's bearing of size P180 complete all as specified and as directed. Make : Kenix/ Skn/ SKF
Supply and fixed rectangular PVC water tank of cap 200 litre complete all as specified and as directed.
S&F in replacement monoblock pump set, single phase, 240 V, capacity 0.75 HP, suction/delivery pipe 25 mm x 25 mm, Head range-6 to 40 mtrs & discharge range - 4000 to 950 LPH, fitted with thermal overload protector & IP-44 protection, 'B' class of insulation, Both side ball bearing double shielded complete all as specified and as directed. Make : Crompton Greaves/ Kirloskar/ KSB
Supply and fixing of LED bulb 12W complete all as specified and as directed. Note: Work to be done at 60 feet height.
S&F in replacement and test sluice valves of under mentioned type, size and class, cast iron body with forged brass spindle, non rising type, and cast iron wheel head, both ends flanged, IS-14846 marked, complete with neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, complete all as specified and as directed.
(a) 200 mm bore, class PN 1.6
(b) 150 mm bore, class PN 1.6
(c) 100 mm bore, class PN 1.6
(d) 80 mm bore, class PN 1.6
S&F in replacement for butterfly valve of under mentioned size complete all as specified and directed.
(a) 80 mm bore
(b) 50 mm bore
S&F in replacement of fountain light 12 Watt with LED driver of IP 66 rating complete all as specified and as directed.
S&F in replacement wall mounted digital Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed. Make: V-Guard model No-VND 500 or equivalent model of Bluebird, Emerson or any other Make mentioned in PS. Note- Old dismantled voltage stabilizer shall be deposited to MES store yard from existing location. The quoted rate shall includes necessary transportation & Manpower for dismantling and transporting the unit.
S&F in repair PCB suitable for split type AC/ window type AC of 1.5/2.0 TR Capacity and any model complete all as specified and as directed.
S & F in replacement sealed compressor unit, rotary type, suitable for 1.5/ 2.0 TR window type AC/ Split AC of existing capacity and make complete all as specified and as directed.
Supply only in replacement running capacitor 50+6 MFD complete all as specified and as directed.
Supply only in replacement Split AC outdoor unit fan motor for any capacity, Single shaft suitable for existing make and model complete all as specified and as directed.
Supply only in replacement fan blade of Condenser motor for Split AC of capacity 1.5TR/2.0 TR complete all as specified and as directed.
S&F in repair Condenser Coil, size 24 inch and 2 row, made out of copper tube & Aluminium fins, suitable for Outdoor Unit of split AC of capacity 1.5/ 2.0 TR of existing make and models complete all as specified and as directed.
M&L for servicing of split type AC of 1.5/2.0 TR capacity, of any type/ make, at site/ wall, including removing power connections and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil, cooling unit and condenser coil of outdoor unit, checking and making serviceable electrical connection of DB's, stabilizer, wiring of AC's as per site condition and tightening all electrical connection with thimble and replacing the spare parts of the AC units wherever required, testing & commissioning including refixing at the original position and connecting with the system complete all as specified and as directed. Note: Spare parts required for repairs shall be measured and paid separately under respective item of this Schedule as supply only.
S&F in replacement C.C. heater for 100 TR compressor unit as per sample at site including all fittings complete all as specified and as directed.
S&F in replacement of condensor and chiller water line sensor complete all as specified and as directed.
Descalling of water cooled condensor of chiller unit of capacity 100 TR, Make : Bluestar complete all as specified and as directed. Note:- Descalling shall be done through Authorised service centre of OEM i.e Blue Star.
Repairing and servicing of LT panel including replacement of unserviceable parts i.e. heat burnt thimble, connectors, dust and dirt cleaning, tight all loose parts and other connected misc work complete all as specified and as directed.
S&F in replacement power pack unit with battery back up 24V DC 7 AH for HT panel protection complete all as specified and as directed.
S&F in replacement over current earth fault with instantaneous micro based programmable relay digital relay in HT panel complete all as specified and as directed.
S&F in replacement sun trip and closing coil assembly 24 V DC for ALSTOM VCB - 01 No. in HT panel complete all as specified and as directed.
S&F in replacement HT panel space heater for panel moisture reduction reduction 220 Volt input 80 Watt complete all as specified and as directed.
Supply and filling Diesel to DG Set of Capacity 630 KVA, Diesel will be collected from Diesel pump filling station private agency approved by i.e Govt IOC/BP /HP including transportation from Petrol/Diesel filling station to Site DG Set Auditorium complete all as directed. Note:- Contractor will be submitted bill/ purchase Vr of diesel from IOC/HP/BP diesel pump filling station to this office, maintain fuel consumption detail resister and verified by JE/ Engr-in-Charge.
Note: The contractor shall arrange their own Ladders/ Elevators and all security arrangement for taking down & fixing of Light fitting & electric wiring, Duct fabrication, duct insulation and all other connected work upto 60 feet heights.
M/S Rohit Enterprises
Sumit Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .