Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.4 L+₹49,260 (1.50%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹34.3 L+₹1.4 L (4.14%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹34.5 L+₹1.6 L (4.90%)Rejected-Finance NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹34.5 L+₹1.6 L (4.97%)Rejected-Finance MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
10 Dec 2022, 6:00 pmClosed
GE AF UDHAMPUR
GE AF UDHAMPUR
RE-WIRING OF CERTAIN OMQs AT AF STN UDHAMPUR
2022_MES_564249_1
GE/AFU-53/2022-23
Open Tender
Civil Works
Item Rate
120 days
GE AF Udhampur
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹74,000
20 Dec 2022
21 Nov 2022
12 Dec 2022
21 Nov 2022
10 Dec 2022
5 Dec 2022
21 Nov 2022 - 28 Nov 2022
Amount
Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete with fittings such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCBs, Main switches from control board and making good disturbed surfaces of walls, floor to match with existing specifications complete all as specified and as directed by Engineer in charge .
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications including wall painting of cutting/chasess portion complete all as specified and as directed by Engineer in charge Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Description all as per serial item No.2 here-in-before but 2 way point controlled by two switches complete all as specified and as directed by Engineer in charge
Description all as per serial item No.2 here-in-before but for one 6 Amps socket outlet on the same board complete all as specified and as directed by Engineer in charge
Description all as per serial item No.2 here-in-before but for one 6 Amps socket outlet on the Independent board complete all as specified and as directed by Engineer in charge
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified and as directed by Engineer in charge Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Switch modular type 6 AMP,one way , one module conforming to IS-3854 complete all as specified and as directed by Engineer in charge
Switch modular type 16 AMP,two way , one module conforming to IS-3854 complete all as specified and as directed by Engineer in charge
Switch modular type, 16/20 Amp, one way, one module conforming to IS-3854 complete all as specified and as directed by Engineer in charge
Socket shuttered outlet 2/3 pin, 6 Amp, modular type, 2 modules complete all as specified and as directed by Engineer in charge
Socket shuttered outlet 2-in-1, 6/16 Amp, modular type, 2 modules complete all as specified and as directed by Engineer in charge
Modular type blanking plate, 1 module,complete all as specified and as directed by Engineer in charge
Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed by Engineer in charge
Lamp holder, insulated body, cord grip pattern SP 230 volt,complete all as specified and as directed by Engineer in charge
Modular electronic fan regulator 2 modules rotary step type 230 volts complete all as specified and as directed.
Electric bell, AC 230 volt, single pole, Ding Dong type complete all as specified and as directed by Engineer in charge
Modular bell push, single pole one way, 1 module, 6 Ampcomplete all as specified and as directed by Engineer in charge
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from sitecomplete all as specified and as directed by Engineer in charge Note: Two runs each of one RM of 4.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with three single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire,including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from sitecomplete all as specified and as directed by Engineer in charge . Note: Three runs each of one RM of 10.00 sqmm main cable and one RM of 10.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Sheet metal enclosures for DBs SPN 12 way single pole and neutral Double door IK 09 215 Volt With metal door to be used) flush mounted including taking down existing unserviceable DBs /board /box including accessories therein and disposing off complete all as specified and as directed by Engineer in charge
Sheet metal enclosures for DBs TPN 12 way Tripple pole and neutral Double door IK 09 415 Volt With metal door to be used) flush mounted isloted neutal Bar including taking down existing unserviceable DBs /board /box including accessories therein and disposing off complete all as specified and as directed by Engineer in charge
MCB TPN 63 Amps, 415 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed by Engineer in charge.
MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed by Engineer in charge.
Supply and fixing of Sheet metal enclosures with socket plug top and MCBs single pole and netural enclosure with a two pin and earth plug and socket complete one single pole 32 Amps Flush mounted including taking down existing unserviceable DBs /board /box including accessories therein and disposing off complete all as specified and as directed by Engineer in charge .
MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed by Engineer in charge.
MCB single pole, 6-32 Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed by Engineer in charge.
MCB single pole, 40 Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed by Engineer in charge .
Sheet metal enclosures for DBs SPN 4 way 200Amps rated busbar including taking down existing unserviceable DBs /board /box including accessories therein and disposing offcomplete all as specified and as directed by Engineer in charge .
Taking down carefully old serviceable/ unserviceable existing conventional light fittings such as T-5/ T-8/ box type /bulk head, 1x40 watt; 1x20 watt, ceiling panel lights etc from existing buildings and disposing off from site complete all as specified and as directed by Engineer in charge Note : Existing serviceable LED luminaries will not be taken down / replaced.
S&F integrated LED bulk head luminarie fittings in engineering plastic housing with clear prismatic /opal diffuser /pressure aluminium die cast housing in white powder coating minimum IP-65 protection, system wattage not more than 10 watt (lumen output not less than 800 lumen) power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation light fitting long life burning hours 50000 hours with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and as directed by Engineer in charge
S&F in repairs of 20 Watt indoor decorative extruded aluminium anodised housing/CRCA sheet steel coated housing LED batten type luminaries 4 feet high efficency electronic driver system wattage 20watt wall mounting arrangement and making connnection with PVC insulated copper condutor 3 core of .5sqmm complete all as specified and as directed by Engineer in charge.
S&F in repairsof 10Watt indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing LED batten type luminaire retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 2 feet (appx) size, high efficiency electronic driver, system wattage 10 watt power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, 0 UV radiation light fitting long life burning hours 50000 hours with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmmcomplete all as specified and as directed by Engineer in charge
Supply and fixing LED Building light of 35 watt, IP66 power coated pressure die cast aluminium compact high power LED buildimg light with heat resistant toughened glass complete with GI pipe bracket light grade 1.2m long of suitable bore fixed on wall with GI clamps, nuts and bolts of suitable size all as specified and as directed complete all as specified and as directed by Engineer in charge
Cutting of existing wall and fixing of Exaust fan and making good such as plaster /randering and white wash etc and fixing exhaust fan bracket with and suitable size of faistner not less than 30cm complete all as specified and as directed by Engineer in charge
Supply and fixing steel iron exhaust fan of 300mm sweep with louvers, single phase 240 volts, isuitable for throwing proper air of exhast fan, making good disturbed surfacecomplete all as specified and as directed by Engineer in charge
S&F in replacement LED retrofit lamp with maximum wattage 9 watt with B 22 holder base with thermal conductive engineering plastic white colour housing and aluninium heat sink with specially designed fins clear/cool white,complete all as specified and as directed by Engineer in charge .
M&L in repair of single pole and earth encloser with three pin and earth plug plus neutral with socket 20 Amps 240Volts complete indrustial type with Tripple pole MCB complete all as specified and as directed by Engineer in charge
Earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using r earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion. Note :- 1.5 cubic metre of soil shall be provided by the contractor from outside the MOD land for refilling the remaining portion of earth pit for increasing soil resistance without any extra cost to the Govt.
Earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using iron strip 25x 4mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion. Note :- 1.5 cubic metre of soil shall be provided by the contractor from outside the MOD land for refilling the remaining portion of earth pit for increasing soil resistance without any extra cost to the Govt.
Supply and fixing of Earth continuity conductor or main25x4mm Galvanised iron streep strip or main earthing lead fixed to wall on battenor recess or chases including plastic type insulatoror buried inground or drawn in conduit/pipe orfixed to poles or any other indicatedsituation for loop earthing etc. all as required and including taking out old unsv up to building height .complete directed by Engr-in-Charge
Supply and fixing of Earth continuity conductor or main 4.0mm Galvanised iron steel wire fixed to wall on battenor recess or chases buried inground or drawn in conduit/pipe or fixed to poles or any DBs other indicatedsituation for loop earthing etc. all as required and including taking out old unsv up to building height .complete directed by Engr-in-Charge
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 70 Sqmm 3.5 core laid on walls/floors or in air with saddles and gutties complete including taking down all as specified and directed.
M&L in replacement of of GI tube light grade of bore 40 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building height complete including taking down all as specified and directed
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 50 Sqmm 3.5 core laid on walls/floors or in air with saddles and gutties complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out, , complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge
Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed by Engineer-in-Charge
Dry sand cushioning to under ground cable all as per clause 19.75 of SSR Part - I laid before and after laying of cable,complete all as specified and as directed by Engineer in charge .
Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable in repair ,complete all as specified and as directed by Engineer in charge.
PCC 1:4:8 type D-2 (Using 40mm graded crushed stone aggregate) as in foundation of poles/stays/Roads/walls etc complete all as specified and as directed by Engineer in charge .
PCC 1:2:4 type B-1 (Using 40mm graded crushed stone aggregate) as in foundation of poles/stays/Roads/walls etc complete all as specified and as directed by Engineer in charge.
Cutting out conctrete blocks slabs brickworks or stone masonary forming tooth ings for and bonding new work in motor into old work including new materials entering old wall type B1 1:2:4 complete all as specified and as directed by Engineer in charge .
Disconnecting and taking down old unserviceable switch fuse unit of any description and capacity and Fabrication, Supplying, Installation, testing and commissioning of 4 compartment energy meter panel 150mm deep made out of 3.15 mm thick CRCA sheet wall/floor mounted type with cubical construction with Aluminium bus bar of capacity 400 Amps 3 phase and neutral bar mounted on epoxy insulators with stainless bolts & nuts, inner connections with 10 Sqmm size, thimbled PVC copper wire, size of each compartment should be 300mm x 300mm x 150mm deep suitable for accomodating one single phase energy meter mounted on 25mm thick hard wood of suitable size having front opening with hinges and sighting window of suitable mesh and glass cover for each compartment with independent MCB control complete with and including following additional accessories :- (Note:- The quoted rate shall be deemed to include disconnecting and refixing of suitable energy meter and repairs including cutting chases to wall, making good the disturbed surfaces to match with the existing specifications complete Civ works all as specified.) (a) One Compartment at the bottom of height 250mm (NS) having one number MCCB of capacity 100 Amps 36 KA for incomming and digital type voltmeter and ammeter with indicating lamps including control wiring. (b) One centre located compartment 200mm wide (NS) for cable entry with front opening. (c) One Top mounted campartment of full width of panel and 150mm height x 200 mm deep (50mm projected at the back side) for all internal connections of submain wiring with front opening. (d) Supply and fixing of 32 Amps SPN MCB 'C' Series-04 Nos duly mounted on rail on each compartment. MAKE :DVEPL/SCHNEIDER /HAVELLS
DAVINDER SINGH
JANDIAL ENTERPRISES
CITY TOP ELECTRICAL WORKS
RANBIR ENTERPRISES
K S BUILDERS
JOGINDER SINGH
M/S M P Construction Co
shivom builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .