Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹2.2 Cr+₹26.8 L (13.5%)Rejected-AOC DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹2.2 Cr+₹26.8 L (13.5%) | L2 | Rejected-AOC Being Not L1 |
| 3 | L3₹2.4 Cr+₹46.3 L (23.4%)Rejected-AOC | ₹2.4 Cr+₹46.3 L (23.4%) | L3 | Rejected-AOC Being Not L1 |
| 4 | L4₹3.1 Cr+₹1.1 Cr (55.8%)Rejected-AOC GURDWARA LINE SHOWROOM NO 6 DESHMESH MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹3.1 Cr+₹1.1 Cr (55.8%) | L4 | Rejected-AOC Being Not L1 |
Tender Value
₹2.3 Cr
EMD Value
₹3.0 L
Closing Date
8 Sept 2021, 6:00 pmClosed
Col PS Chand, CWE
Commander Works Engineer Military Engineer Serivces Minniebay Junglighat Post Port Blair 744103
80853 Augmentation of Gearing and Shafting Facilities at NSRY Port Blair
2021_MES_460754_1
80853 Aug of Gearing and Shafting Port Blair
Open Tender
Civil Works
Lump-sum
540 days
GE P North Port Blair
Class B Category a i
8 documents required · 8 mandatory
₹2,000
GE P North
₹3.0 L
Yes
20 Nov 2021
17 Jul 2021
13 Sept 2021
17 Jul 2021
8 Sept 2021
25 Aug 2021
Amount
SCHEDUEL 'A' PART- I TO XII NOTES: Schedule ‘A’ Part- I to X are prepriced by MES under Ser No. 1.00 to 12.00. Bidders shall insert their lump sum amount in the Green coloured field under Col-6 only.
Lump sum price worked out by the tenderer for "Building/Structures" as listed in Schedule 'A' Part-I
Lump sum price worked out by the tenderer for "Excavation, Earth work, site clearance and Land Development" as listed in Schedule 'A' Part-II
Lump sum price worked out by the tenderer for "Internal Water Supply" as listed in Schedule ‘A’ Part-III
Lump sum price worked out by the tenderer for "Internal Electrification" as listed in Schedule ‘A’ Part-IV
Lump sum price worked out by the tenderer for "External Water Supply" as listed in Schedule ‘A’ Part-V
Lump sum price worked out by the tenderer for "External Electrification" as listed in Schedule ‘A’ Part-VI
Lump sum price worked out by the tenderer for "Road, Hard standing, Path" as listed in Schedule ‘A’ Part-VII
Lump sum price worked out by the tenderer for "Sewage Disposal" as listed in Schedule ‘A’ Part-VIII
Lump sum price worked out by the tenderer for "Area Drainage" as listed in Schedule ‘A’ Part-IX
Lump sum price worked out by the tenderer for "Lightening Protection" as listed in Schedule ‘A’ Part-X
Lump sum price worked out by the tenderer for "Water Coolers" as listed in Schedule ‘A’ Part-XI
Lump sum price worked out by the tenderer for "Fire Alarm System" as listed in Schedule ‘A’ Part-XII
Subtotal
NOTE: Schedule ‘A’ Part - XIII is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
SCHEDULE `A' PART - XIII (MISC ITEMS)
Internal Water supply
Supply and fix Health faucet chromium plated with 1.5m length pipe, wall hook, non return valve complete all as specified
Internal Electrification
S&F telephone socket RJ-11, with shutter 1 module all as directed. Make:Havells, Cat No:AHLKPWG001 or equiv in Havells
M&L for Telephone cable 5 pair, Make: Havells, cat no:WHTTATEA5P40 or equiv in Finolex
S&F ultra slim elegance LED lighting fixture with extruded Aluminium heat sink, integrated electronic driver ( Minimum 105 lum/watt), 18 watts, 5700K(2ft) Energy Efficient and environmental friendly, all as directed by the Engg-in-charge. Make : Havells/ Wipro/Philips/ Crompton
S&F ultra slim elegance LED lighting fixture with extruded Aluminium housing for heat dessipation, integrated electronic driver, 10 watts, 5700K(2ft) Energy Efficient and environmental friendly, all as directed by the Engg-in-charge. Make : Havells/ Wipro/Philips/ Crompton
S&F TPN DB vertical 12 way with MCCB incoming/ 4 pole and MCB Outgoing all as directed by the Engg-in-charge. Make: Havells , Legrand/ L&T
S&F MCB, 4 pole,40 Amp rating, 415Volts,16 Ka Breaking capacity, with fixed thermal and magnetic setting all as directed by the Engg-in-charge. Make: Havells, Legrand/L&T
S&F MCB, SP, B-Series 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA. Make-Havells /Legrand/ L&T
S&F MCB, SP&N, C-Series 240 Volts of capacity 6-32 Amps as ordered breaking capacity 10 KA. Make-Havells /Standard/L&T/Indo Asian.
S&F MCB, SP&N, C-Series 240 Volts of capacity 40 Amps as ordered breaking capacity 10 KA. Make-Havells /Standard/L&T/Indo Asian.
S&F MCB, SP&N, C-Series 240 Volts of capacity 63 Amps as ordered breaking capacity 10 KA. Make-Havells /Standard/L&T/Indo Asian.
S&F exhaust fan of sweep 250mm, pace type, single phase with their all accessories fixed properly on wall surfaces including connecting/testing complete as directed. Make: Havells Venti Air-DX-White or equiv. in Usha/Almonard
S&F ceiling fan 1200mm sweep, 5 star rated ,230V, complete including all accessories. Make: Havells, Cat no: ES-40 or equiv Bajaj/ Crompton
S&F SMD bay light 100 watt with pressure diecast aluminium housing complete with all accessories and fixing in wall, ceiling/steel truss with clamps in and including 1.5 Sqmm 3 core copper cable from ceiling rose to light fitting and luminaries efficacy not less than 110 Lm/watt Make:- Havells/C&S/Crompton/ Luker
Supply and fix air circulator high speed fan 600mm sweep, wall mounted working on single phase 230 volts, 50 Hz AC Supply complete including electric connection from ceiling rose to fan connector with PVC insulated 3 core copper cable of suitable size complete all as directed by Engineer-in-Charge. Maker: Havells/ Bajaj/ CG/ Almonard
External Water Supply
Cutting cast iron pipes/GI pipes of size 80 mm dia and inserting Tee of size 80x80x40 mm and branches including necessary earth work and other connected work complete all as specified and as directed.
External Electrification
Supply, installation, testing and commissioning outdoor LT Distribution Panel suitable for 3 phase, 4 wire, 415 volts to Hz supply system with suitable size and powder coating provided with suitable to make it dust/vermin proof. The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 2mm thick CRCA sheet, double door with front and back openable with locking arrangement, provision of threaded earthing stud at bottom, inner shell completely vermin proof and to accommodate incoming / outgoing MCCB, MCBs and suitable rated TPN aluminum bus bar and extension links of rating not less than 1.5 times the rates capacity of the respective MCCBs. The TPN busbar and extensions link shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on epoxy resin insulator. Current transformer with ration 400/5 Amp -1 No. All control wires shall be with 2.5 sqmm multistandad copper conductor wire and shall be properly bunched, tied ferruled for proper identification and crimped with adequate size of lugs. The panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground level and 45cm embedded in ground with PCC 1:3:6, type C2 complete, computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided. The panel shall be consist of the following accessories:-
Incoming:- a) MCCB 4 Pole, 400 Amp , 415 Volts, 50 Hz, breaking capacity 35 KA - 01 No Out going:- (a) MCCB 3 Pole, 200 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA - 02 Nos (for user panel Eqpt.) (b) MCCB 3 Pole, 63 Amp , 415 Volts, 50 Hz, breaking capacity 16 KA - 02 No (for user panel Eqpt) (c) MCCB 3 Pole, 32 Amp , 415 Volts, 50 Hz, breaking capacity 16 KA - 02 No ( for street light and misc) (d) Digital multifunction meter measuring V.I.PF, KVA KVR, KWH-01. (e) LED panel indicators R, Y B-02 Set. (f) CT with ratio 400/5Amp-1.
Supply and fix LED street light 36W IP 66 with high power LED, uniform light distribution, minimum efficacy 100 Lum/watt, high pressure die cast aluminium housing poly carbonate/glass cover. Make: Philips/Havells/Crompton/ Luker
Supply and fix HDGI Hexagonal/octagonal pole 5 meter height having top dia 70 mm and bottom dia 135 mm and thickness 3 mm , including heavy duty GI pile light mounting bracket with nuts and bolts , 4 Nos 'J' hook foundation bolts of dia 16 mm and 450 mm long with base plate. Note : PCC/RCC foundation will be measured and paid separately.
Excavation in post holes not exceeding 0.5 cum for erection of pole , removing the excavated material to a distance not exceeding 50 meter and providing PCC bed and RCC foundation as per the following including form work. (a) Excavation- 0.45x0.45x1.2 m (b) Steel 12mm 1.7 M x 4 Nos = 6.8M (c) Steel 08 mm 1.6 M x 7 Nos = 11.2M (d) RCC column M-20 aggregate =0.4mx.0.4mx1.3 m (e) PCC bed - 450mmx450mmx100mm D2 1:4:8 using 40 mm graded aggregate
AIR CONDITIONING & WATER COOLER
Supply, install & commissioning of inverter type hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 Ton complete of indoor and out door unit with copper condenser coil, necessary copper pipe connection between indoor and out door unit as required length with suitable size of PVC insulated copper cable 3 core and factory made bracket for mounting of out door unit complete, all as specified and directed by Engr-in-Charge. Make: Blue star/Voltas/Samsung
Supply and fix 3KVA voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% all as specified and as directed.
Supply and fix 1 KVA voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% all as specified and as directed.
FIRE ALARM
Supply and laying testing PVC insulated PVC sheathed cable galvanised steel strip or wire armoured, electric control cables (heavy duty) stranded copper conductor of size 1.5 sqmm 4 core 1100 Volts
PILE FOUNDATION
Drilling / boring through any type of soil (soft/loose soil or hard/dense soil/stiff clay/sand/cobble stone/soft conglomerate/loose boulders) up to the depth as directed/indicated for 500mm outer dia bored cast-in-situ vertical piles duly stabilizing the sides by drilling fluids (Reverse or DMC method) or by driving 6mm thick casing pipe upto loose strata or refusal level or by any other approved method and disposal of drilling/bored material to a distance exc. 50m. and not exc. 100m all as specified and shown on drawings.
All as per Item No.38 above but on soft rock
All as per item No.38 above but on hard rock
Note for Item No.38 to 40 (i) Concrete and reinforcement shall be measured and paid separately. (ii) The boring of piles shall be commenced from original ground level before carrying out site leveling work. The depth of boring of piles shall be measured from the top of original ground level to the approved founding level. (iii) Bentonite slurry used for mixing with soil (obtained from the boring) shall be disposed off out side MD land as directed by the Engineer-in-Charge. The unit rate quoted against above item shall interalia be deemed to included for this operation and no extra payment shall be admissible on this account. (iv) Casing pipe used while driving of piles shall be removed after providing RCC cast in situ piles as directed by the Engineer-in-Charge. The unit rate quoted against above items shall interalia be deemed to include for this operation and no extra payment shall be admissible on this account
M&L for M-35 design mix concrete for cast-in-situ piles using termite method including chipping of piles from cut off level to a minimum height of 50cm including necessary excavation and earth work together with disposal of chipped off concrete and spoil obtained from excavation to a distance exc. 500m. and n.exc. 1000m. complete all as specified and shown in drawings. Note :Reinforcement shall be measured and paid separately under relevant items of this Schedule.
M&L for high strength deformed steel CRS bars 10mm dia and over, cut to length, bent to shape required, including cracking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified. and as directed.
M&L for high strength deformed steel CRS bars, 5mm to 10mm dia cut to length, bent to shape required including cranking and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders all as specified and as directed.
Carryout /Conducting SPT all as per IS - 2911 Part -IV - 1985 in the strata where pile is proposed to be rested / terminated incl bringing at site all testing equipment making arrangement for testing and removal of the same after completion and recording the test results and test sheets completed for 600 dia to 700 dia piles all as specified and directed.
Carrying out/conducting testing of pile for Initial load test all as per clause 6.1.5. & 6.1.6 of IS-2911 Part - IV - 1985, for 71MT ultimate load on test pile of 500mm bore including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion and recording the test results and preparing the test sheets complete all as specified and directed.
Carrying out/conducting testing of pile for routine load test all as per clause 6.1.5. & 6.1.6 of IS-2911 Part - IV - 1985, for 43 MT ultimate load on working pile of 500mm bore including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion and recording the test results and preparing the test sheets complete all as specified and directed.
M&L for carrying non-destructive integrity test on piles as per IS:2911 Part IV by using pile integrity tester complete as specified as directed
EOT CRANE 20 TON
Design, Supply, install fix, Testing and commission of indoor type class M7 duty electrically operated, overhead travelling crane (EOT) of capacity 20 Ton, Double girder type over head travelling crane (EOT) of capacity 20 Ton,suitably designed for the proposed building/structure.confirming to following specification complete:- (a) Cross travel (CT) span - 8 mtr (b) Long travel (LT) span 15.3mtr (c) Clear Hook high - 6 mtr from FFL (d) Speed (M/Min) (i) Cross travel - 15 M/min (ii) Long travel - 25 M/min (iii) Main hoist - 03 M/min (e) Control system - The control panels shall be provided with VWF controls. (f) Method of operation - The crane shall be operated by pendant from floor level with provision for two speed micro and main speed. (g) Load indicator - LED display load indicator with load pin type load cell with provision for indication of load, alarm and shut down of Crane in case of load greater than 10% of rated load. 47 Contd…/-
47.00 Contd…/- (h) Audio & Visual indicators - Siren with audio and visual facility shall be provided to provide indication white crane is in operation NOTE:- (i) The scope includes long travel beam along with rail, box type double girder with rail shouded bus Bar, all safety provision with limit switch, EHT Breakers and any accessories of recommended by OEM. (ii) The contractor shall submit design data, drawings, detailed specification of the crane and shall be get approved by the Accepting Officer.
Supply and fix electric motor 3 Phase, 440 volts 50Hz capacity 3 HP with gear box, chain & sprocket for opening & closing (forward & reverse motion) of rolling shutter with suitable starter panel with facility for forward & reverse operation of motor, including door limit switches, LT copper cable from starter panel to motor.
Supply and fix roof mounted Turbo ventilator 600 mm sweep, including metal base plate with SS variable duct suitable for roof mounting complete all as specified and as directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60x60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected using galvanised iron strip 32x6mm as earthing earthing lead by means of bolts nuts, check nut and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point all as specified or indicated including testing on completion. Note: 1. The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC M-25 (design mix) cover 50 mm thick reinforced with 8 mm dia CTD bars @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe medium grade 40 mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. page No.347 of SSR Part-II. 2. On completion if desired value is not obtained the contractor shall redo the earthing at his own expenditure.
M & L, Earthing complete with GI plate electrode of size 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal Ground Level connected to GI wire 4.0 mm dia as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 5 of SSR Part-I connected to main board/distribution board complete all as specified and directed. Note 1. The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC M-25 (design mix) cover 50 mm thick reinforced with 8 mm dia CTD bars @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe medium grade 40 mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. page No.347 of SSR Part-II. 2. On completion if desired value is not obtained the contractor shall redo the earthing at his own expenditure.
M& L for cutting existing road/hard standing notexc 45x60 cm in wide and depth getting out excavated material for laying GI tube returning filling & well ramming watering finish surface 15 cm from top using PCC 1:3:6 including removal of surplus soil all as directed.
Subtotal
Sree Tirumala Enterprises
SACKSON ENTERPRISES
SALCON ENGINEERS AND FABRICATORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .