Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.3 LAccepted-AOC | 1 | Accepted-AOC 1st lowest | |
| 2 | 2₹14.0 L+₹68,232.98 (5.13%)Rejected-AOC | 2 | Rejected-AOC 2nd Lowest | |
| 3 | 3₹14.6 L+₹1.3 L (10.1%)Rejected-AOC 258 SECTOR 5 REWARI 123401 | REWARI | REWARI | HARYANA | 123401 | 3 | Rejected-AOC 3rd Lowest | |
| 4 | 4₹14.8 L+₹1.5 L (11.0%)Rejected-AOC | 4 | Rejected-AOC 4th lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Technically disqualified |
Tender Value
₹15.6 L
EMD Value
₹31,160
Closing Date
30 Dec 2024, 5:00 pmClosed
GAJENDER SINGH
PD - II, Gurgaon
Construction of underground water tank and UG pump room for firefighting at 50 bedded hospital at Farrukhnagar in Gurugram District. (Against the A/A of construction of 50 bedded hospital at Farrukhnagar in Gurugram District)
2024_HRY_419957_1
2024772596D6 B317 4C68 BE6D 0DB28DB89B08622BAR
Open Tender
Civil Works
Works
90 days
Farukh Nagar
2 documents required · 2 mandatory
₹1,000
₹31,160
Yes
17 Apr 2025
24 Dec 2024
31 Dec 2024
24 Dec 2024
30 Dec 2024
24 Dec 2024
[10.35.1]FLAT BRICK OR TILE FLOORING 1. Providing and laying of flat brick or tile flooring with bricks of class designation 7.5 laid in cement sand mortar 1:4 on 100 mm thick cement concrete 1:8:16 and 100 mm sand filling and cement pointing 1:2 on top.
[11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand)
[11.5.1]12 mm cement plaster of mix : 1. 1:2 (1 cement: 2 fine sand)
[11.52]Cement rendering on plaster 1 mm thick
[15.1.1.3]Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per clause 304 of MORTandH specifications Ordinary soil 1.3. Manual Means Depth above 6 m
[21.93.1]Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening
[6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
[6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
[6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
[6.30.2]Centering and shuttering including strutting, propping etc. and removal of form for 2. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform
[6.33.3]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 3. Cold twisted bars
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .