Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
18 Dec 2021, 2:00 pmClosed
Executive Engineer JPDCL ED Kathua
Office of the Executive Engineer JPDCL ED Kathua
Fixing of Rate Contract for Improvement /Maintenance/Emergent works of HT/LT Distribution Network including 11/.433KV Sub Stations in various Sub Division of Electric Division, Kathua(JPDCL) on Turnkey basis
2021_PDD_152678_1
KED/38 of 2021-22 Dt.09.12.2021
Open Tender
Electrical and Maintenance Works
Turn-key
5 days
kathua
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Executive Engineer JPDCL ED Kathua
Exempted
31 Dec 2021
11 Dec 2021
20 Dec 2021
11 Dec 2021
18 Dec 2021
11 Dec 2021
11 Dec 2021 - 15 Dec 2021
Amount
Replacement of damaged pole by way of Supply, Transportation, Erection including excavation of pit and back filling of soil & consolidating by ramming, watering etc.& dismentaling/disposal of existing pole including carriage of dismantled ST Poles to Divisional Store at Kathua
8.0 Mtr Long PCC Pole(W/L-200Kgs)
9.0 Mtr Long PCC Pole(W/L-300Kgs)
11.0 Mtr Long PCC Pole(W/L-360Kgs)
8.0 Mtr Long ST Pole(410 SP 15)
9.0 Mtr Long ST Pole(410 SP 33)
11.0 Mtr Long ST Pole(410 SP 56)
13.0 Mtr Long ST Pole(410 SP 69)
Erection of pole by way of Supply, Transportation, Erection including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
8.0 Mtr Long PCC Pole(W/L-200Kgs)
9.0 Mtr Long PCC Pole(W/L-300Kgs)
11.0 Mtr Long PCC Pole(W/L-360Kgs)
8.0 Mtr Long ST Pole(410 SP 15)
9.0 Mtr Long ST Pole(410 SP 33)
11.0 Mtr Long ST Pole(410 SP 56)
13.0 Mtr Long ST Pole(410 SP 69)
Replacement of damaged conductor by way of Supply, Laying & Stringing through insulators including proper binding & twisting with soft Aluminium Wire and dismantling/disposal of old conductor in HT/LT Network including carriage of dismantled Conductor to Divisional Store at Kathua
ACSR Squirrel Conductor
ACSR Weasel Conductor
ACSR Rabbit Conductor
ACSR Dog Conductor
Laying of conductor by way of Supply, Laying & Stringing through insulators including proper binding & twisting with soft Aluminium Wire
ACSR Squirrel Conductor
ACSR Weasel Conductor
ACSR Rabbit Conductor
ACSR Dog Conductor
Supply, Laying & Stringing of ACSR Conductor through insulators including proper binding & twisting with soft Aluminium Wire for thickening
ACSR Weasel Conductor(For Thickening from Squirrel to Weasel)
ACSR Rabbit Conductor(For Thickening from Weasel to Rabbit)
ACSR Dog Conductor(For Thickening from Rabbit to Dog)
Supply and Fixing of
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Earthing complete by GI Pipe of 40mm or GI rod 20mm , 2.5 Mtr long through GI Strip of 25 X 3 mm to each pole
Earthing complete with GI Spiral Earthing 8 SWG 115 Turns Coil Earthing
11 KV Link Set (450 x 50 x 6mm)
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11 KV Pin Insulator with Pins (Polymer) 10 KN
11 KV Disc Insulator with Fittings (Polymer) 45 KN
11 KV Pin Insulator with Pins (Porcelain) 10 KN
11 KV Disc Insulator with Fittings (Porcelain) 45 KN
MS U-Clamp with Shackle Insulator (Porcelain) alongwith Nut & Bolt of sorts
16 KN Shackle Insulator (Porcelain)
GI Pin for 11KV Pin Insulator(800gms)
Galvanised Nuts and Bolts of sizes
Suspension clamps for HTABCables
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated
Supply, Transportation, Fabrication & Fixing of Galvanised Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated
Supply and Replacement of
HT XLPE Cable 50sqmm
HT XLPE Cable 95sqmm
HT XLPE cable 120sqmm
HT XLPE Cable 185sqmm
HT XLPE Cable 300sqmm
HT XLPE cable 400sqmm
HT XLPE cable 630sqmm
HT AB Cable 50sqmm
HT AB Cable 95sqmm
HT AB cable 120sqmm
HT AB Cable 185sqmm
HT AB Cable 300sqmm
HT AB cable 400sqmm
HT AB cable 630sqmm
LT XLPE Cable 3.5 Core 50sqmm
LT XLPE Cable 3.5 Core 95sqmm
LT XLPE cable 3.5 Core 120sqmm
LT XLPE cable 3.5 Core 185sqmm
LT AB Cable 3.5 Core 50sqmm
LT AB Cable 3.5 Core 95sqmm
LT AB cable 3.5 Core 120sqmm
LT AB cable 3.5 Core 185sqmm
Supply & erection of Heat Shrinkable Outdoor Kit for
HT AB/XLPE Cable 50sqmm
HT AB/XLPE Cable 95sqmm
HT AB/XLPE cable 120sqmm
HT AB/XLPE cable 185sqmm
HT AB/XLPE cable 400sqmm
HT AB/XLPE cable 630sqmm
LT AB/XLPE Cable 50sqmm
LT AB/XLPE Cable 95sqmm
LT AB/XLPE cable 120sqmm
LT AB/XLPE cable 185sqmm
Supply and Fixing of Mid Span Straight Jointer Kit for
HT AB/XLPE Cable 50sqmm
HT AB/XLPE Cable 95sqmm
HT AB/XLPE cable 120sqmm
HT AB/XLPE cable 185sqmm
HT AB/XLPE cable 300sqmm
HT AB/XLPE cable 400sqmm
HT AB/XLPE cable 630sqmm
LT AB/XLPE Cable 50sqmm
LT AB/XLPE Cable 95sqmm
LT AB/XLPE cable 120sqmm
LT AB/XLPE cable 185sqmm
01 No.8Mtr ST/PCC Pole, Cement bottoming with 1:2:4 mix as per RE Standard upto 0.25 Mtr above ground and 1.33 Mtr below ground width 0.6 Mtr X 0.6 Mtr including plastering and curing of Concrete
01 No.9 Mtr ST/PCC Pole, Cement bottoming with 1:2:4 mix as per RE Standard upto 0.25 Mtr above ground and 1.5 Mtr below ground width 0.6 Mtr X 0.6 Mtr including plastering and curing of Concrete
01 No.11 Mtr ST/PCC Pole, Cement bottoming with 1:2:4 mix as per RE Standard upto 0.25 Mtr above ground and 1.8 Mtr below ground width 0.6 Mtr X 0.6 Mtr including plastering and curing of Concrete
01 No.13 Mtr ST/PCC Pole, Cement bottoming with 1:2:4 mix as per RE Standard upto 0.25 Mtr above ground and 2.1 Mtr below ground width 0.6 Mtr X 0.6 Mtr including plastering and curing of Concrete
Supply fixing of PG clamps for jointing of snapped conductor for ACSR Dog/,Rabbit /Weasel
Supply and Painting of ST Poles with Red Oxide & Aluminium Paint
8.0 Mtr Long ST Pole(410 SP 15)
9.0 Mtr Long ST Pole(410 SP 33)
11.0 Mtr Long ST Pole(410 SP 56)
13.0 Mtr Long ST Pole(410 SP 69)
Supply &Fixing of Anchoring Clampsfor HT ABCables
Supply & fixing of jumper on 11kv line with ACSR Dog
Supply & fixing of jumper on 11kv line With ACSR Rabbit
Supply & fixing of jumper on 11kv line with ACSR Weasel
Supply & fixing of Jumpers on LT Line with ACSR Dog
Supply & fixing of Jumpers on LT Line with ACSR Rabbit
Supply & fixing of Jumpers on LT Line with ACSR Weasel
Supply & fixing of Jumpers on LT Line with ACSRSquirrel
Supply & Fixing of PVC Cable Single Core for replacement of burnt out
Supply & Fixing of Al. Thimbles for replacement of burnt out
Supply & Fixing of LT Distribution Box with
63 Amp MCCB
100 Amp MCCB
200 Amp MCCB
250 Amp MCCB
400 Amp MCCB
Providing and fixing of pre fabricated LT Switch
Earthing of substation -Earthing by GI Pipe 40mm or GI Rod 20mm 2.5 Mtr Long through GI Strip of 50 X 6 mm for Neutral earthing, 25 X 3mm for 2 Nos. Transformer body earthing as per J-2 REC Drawing. 1 No. LA Earthing 1 No. G.O Earthing Note:- For LA Earth 1 Pipe shall be kept seperatly
Supply ,erection testing and commissioning of LT 3-Ø, 4-wire Trivector Meter (Prodigy Meter)
Supply and fixing of 11KV CT/PT Units of various ratios including 3-Phase, 4-wire Trivector Meter with compatible Meter Box and PVC Copper Control cable 10 core having 10 Mtr Length(Complete Unit)
Supply and fixing of 11KV CT/PT Units(Dry Type) of various ratios including 3-Phase, 4-wire Trivector Meter and PVC Copper Control cable of required length and 3 Core HT XLPE cable 95sqmm ,2X10 Mtr=20mtr(Kiosk Type)(Complete Unit)
Supply & Fixing of LT Line Spacers
Supply &Fixing of Suspension clamps for LT ABCables
Supply &Fixing of Anchoring Clamps for LT ABCables
Supply and fixing of service line 1 Phase connection upto 10Mtr length
Supply and installation of 1-Phase energy meter with box and sealing
Supply and installation of 3-Phase energy meter with box and sealing
Supply and making, fixing of cradle guard of 8SWG G.I wire comprising of a minimum of 10 No. cross pieces per span including connection to earth on both ends
Average Carriage of Poles upto Ist 100 Mtr (only applicable to sites where vehicle could not reach)
8.0 Mtr Long PCC Pole(W/L-200Kgs)
9.0 Mtr Long PCC Pole(W/L-300Kgs)
11.0 Mtr Long PCC Pole(W/L-360Kgs)
8.0 Mtr Long ST Pole(410 SP 15)
9.0 Mtr Long ST Pole(410 SP 33)
11.0 Mtr Long ST Pole(410 SP 56)
13.0 Mtr Long ST Pole(410 SP 69)
Average Carriage of Poles from 100 mtr to 200 Mtr (only applicable to sites where vehicle could not reach)
8.0 Mtr Long PCC Pole(W/L-200Kgs)
9.0 Mtr Long PCC Pole(W/L-300Kgs)
11.0 Mtr Long PCC Pole(W/L-360Kgs)
8.0 Mtr Long ST Pole(410 SP 15)
9.0 Mtr Long ST Pole(410 SP 33)
11.0 Mtr Long ST Pole(410 SP 56)
13.0 Mtr Long ST Pole(410 SP 69)
Average Carriage of Poles beyond 200 Mtr(on per 100Mtr basis) (only applicable to sites where vehicle could not reach)
8.0 Mtr Long PCC Pole(W/L-200Kgs)
9.0 Mtr Long PCC Pole(W/L-300Kgs)
11.0 Mtr Long PCC Pole(W/L-360Kgs)
8.0 Mtr Long ST Pole(410 SP 15)
9.0 Mtr Long ST Pole(410 SP 33)
11.0 Mtr Long ST Pole(410 SP 56)
13.0 Mtr Long ST Pole(410 SP 69)
Manual carriage of line material to site of work beyond 25 Mtr. for first 100 Mtr .(only applicable to sites where vehicle could not reach)
Manual carriage of line material to site of work for additional 50 Meters or part thereof (only applicable to sites where vehicle could not reach)
Supply and Fixing of 11KV CT/PT unit of various ratios(Oil Type)
Replacement of Suspension Clamps for AB Cable of sizes
Replacement of Tension Clamps for AB Cable of sizes
Supply and fixing of IPC Connectors for AB Cables of sizes
Suuply and fixing of Plastic Tamper Proof Seals for sealing Energy Meters and CT Pt Unit
Supply and fixing of LT Bush Clamps for Transformers of Various Capacities
Supply and fixing of Aluminium Bus Bar 50X100mm for LT switch
Supply and fixing of Bus Bar Insulators for LT switch
Repalcement of damaged 11KV/LT Bushing of Different Transformers
Repalcement of damaged 11KV Bush Rods of Different Transformers
Repalcement of damaged LT Bush Rods of Transformers(25/63/100KVA)
Repalcement of damaged LT Bush Rods of Transformers(250KVA)
Repalcement of damaged LT Bush Rods of Transformers(400/630KVA)
Excavation and laying of HT cables of sizes in underground channels/paths
M/S SUKRALA ELECTRICAL WORKS
EMINENT ENGINEERING SEVICES
SUMIT SHARMA
M/S SINGH ELECTRICAL CONTRACTOR AND SUPPLIERS
VARUN PATHAK GOVT CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .