| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.1 LAccepted-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L1 | Accepted-AOC L1 | |
| 2 | L2₹47.1 L+₹3.6 L (8.28%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹47.2 L+₹3.7 L (8.61%)Rejected-Finance 9 SHUBHASH BHAWAN RAJENDAR MARG MOUNT ABU 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹47.6 L+₹4.1 L (9.48%)Rejected-Finance INDEX NO B 48 HQ CE SWC JAIPUR A 202 RATHRAM PANORAMA GALA GIMAKHANA ROAD NEAR AMMANJARI BUNGLOWS SOUTH BOPAL AHMEDABAD 380058 | AHMEDABAD | AHMEDABAD | GUJARAT | 380058 | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹48.4 L+₹4.9 L (11.4%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹46.5 L
EMD Value
₹93,060
Closing Date
19 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Chiloda
GE (AF) Chiloda, LekawadaPatia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
SPL REPAIR/ REPLACEMENT OF OLD WATER SUPPLY PIPE LINE AND CONNECTED WORKS, SPL REPAIR TO SUB MAIN WIRING AND CONNECTED ITEMS IN HQ BLDG, SPECIAL REPAIR/ REPLACEMENT OF MISC E/M ITEMS AGAINST BER AND CERTAIN MINOR WORKS AT GNR UNDER GE (AF) Chiloda
2024_MES_686384_1
8208/24-25/E8
Open Tender
Miscellaneous Works
Item Rate
GANDHINAGAR
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹93,060
Yes
14 Feb 2025
30 Nov 2024
21 Dec 2024
30 Nov 2024
19 Dec 2024
14 Dec 2024
Amount
Taking out GI pipe 80/100 mm bore with all fittings and accessories etc, from trenches/ surface complete all as specified and directed.
Taking out GI Pipe 40/50mm bore with all fittings and accessories etc, from trenches/ surface complete all as specified and directed.
Taking out GI Pipe 25/20mm bore with all fittings and accessories etc, from trenches/ surface complete all as specified and directed.
M & L for laying & jointing 100 mm dia UPVC pipes Sch- 80 with all fittings fixed to walls or laid in floors /trenches including testing complete all as specified and directed.
M & L for laying & jointing 80 mm dia UPVC pipes Sch- 80 with all fittings fixed to walls or laid in floors /trenches including testing complete all as specified and directed.
M & L for laying & jointing 50 mm dia UPVC pipes Sch- 80 with all fittings fixed to walls or laid in floors /trenches including testing complete all as specified and directed.
M & L for laying & jointing 40 mm dia outer dia CPVC pipes SDR-11 with all fittings fixed to walls or laid in floors /trenches including testing complete all as specified and directed.
S & F 25 mm dia outer dia CPVC pipes SDR-11 with all fittings fixed to walls or laid in floors /trenches including testing complete all as specified and directed.
S & F 20 mm dia outer dia CPVC pipes SDR-11 with all fittings fixed to walls or laid in floors /trenches including testing complete all as specified and directed.
Supply and fixing steel water tubing 80mm bore heavy duty galvanised ISI maked with all fittings of with double end flanged (thickness of flanged not less than 10mm) welded to pipe in multiple length including jointing rubber gasket, bolt and nuts complete fixed on walls/floors etc including painting with approved synthetic enamel paint complete all as specified and directed. (For motor pipe)
Material & labour for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in copping, as in floor/road finishing even and fair, as in making cement concrete thrust block for supporting of pipe bend, tee, dead end etc including any necessary work or in any other situation work complete all as specified and directed.
Demolition for cement concrete paving n. exc 15 cm thickness Roofs, floors beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
M & L for core cutting holes into or through Brick wall, cement concrete slabs, RCC wall etc for inserting of pipe upto 100 mm dia and making good disturbed surface of walls, floors, etc. complete all as specified and directed.
M & L for boring under road/ hard standing by machine /manual method for inserting the GI tubing up to 80 mm dia complete all as specified and directed by Engineer in Charge.
Supply and lay Pipes MS ERW including specials, nominal dia 200 mm as per IS 3589 (1981) thickness not less than 5.4 mm for making hydral point with flnage end ( thickness of flanged not less than 10 mm ) incl three incoming branch pipe connection 80 mm dia -2 Nos and one 50mm dia , Two out going connection 100 mm dia and 50 mm dia with welded flanged end. and supporting PCC piller etc complete including two coat of anti-corrosive paint over a coat of red oxide primer complete all as specified and directed.
S & F for heavy duty bellows expansion joint 16 PN flanged end type suitable for 80 mm dia water pipe complete all as specified and directed.
S & F for Electromagnetic flow meter flange end type, 2 digital outputs, Integral mount design With separate LCD display, 230 V AC supply, Nominal pressure rating not less than PN 10, Robust construction for rough environmental conditions Protection Class -IP 67 suitable for 80 mm dia pipe incl connection cable complete all as specified and directed.
S & F PVC insulated and FR PVC Round Sheathed, 6 core x 0.50 sqmm copper conductor cable, for water level indicator fixing on wall/ floor in PVC conduit or hanging in air with the help of GI wire complete all as specified and directed by Engineer-in-Charge.
S & F Water Level Indicator with Low & High Water Level Alarm conforming with 4 levels of LED indication representing 25%, 50%, 75% and 100% levels in the tank, Power ON Led indication, Audio & visual Level indication including with 4 Nos moulded silver steel contact type sensor complete all as specified and directed by Engineer-in-Charge.
M & L for Reinforced cement concrete 1:2:4 type B1 (20 mm graded aggregate) as in pipe route indicator pillars size not less than 0.3x0.1 x0.75 mtr including use and waste of necessary formwork etc. and Engraving "UPVC Pipe 80/50/40mm Dia" on one side surface of each boundary pillar (when concrete is green) as per approved pattern including painting synthetic enamel paint etc. and grouting complete all as specified and directed.
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/ loose soil for taking up/ laying cable/pipe etc complete all as specified and directed.
Returning, filling including spreding, leveling watering & well ramming in laying not exc. 25cm for soft/ loose soil complete all as specified and directed.
Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point for soft/ loose soil complete all as specified and directed.
S & F in replacement old u/s non return butterfly valve suitable for 80 mm dia pipe complete all as specified and directed.
S & F in replacement old u/s butterfly Valve 100 mm dia (Wafer Type) Lever Operated, S.G. Iron body PN-1.6 with S.S Disc , EPDM Rubber Lining complete ISI marked complete all as specified and directed.
S & F in replacement old u/s butterfly Valve 80 mm dia (Wafer Type) Lever Operated, S.G. Iron body PN-1.6 with S.S Disc , EPDM Rubber Lining complete ISI marked complete all as specified and directed.
S & F in replacement old u/s butterfly Valve 50 mm dia (Wafer Type) Lever Operated, S.G. Iron body PN-1.6 with S.S Disc , EPDM Rubber Lining complete ISI marked complete all as specified and directed.
S & F in replacement old u/s Foot Valve conforming to IS 4038, Made of cast iron material one side flange end and other side strainer and floating reinforced rubber coated ball as per exixting sample for 80 mm dia pipe complete all as specified and directed.
Supply and fixing in replacement old u/s Pressure gauge 4" dial 0-14 kgs rating complete all as specified and directed.
Supply and fixing gun metal Ball/gate valve, screwed both ends and fixed suitable for 50mm bore pipe including dismantling and taking out existing unserviceable one complete all as specified and directed.
All as per item No 30 here in before but gun metal Ball /gate valve for 40 mm dia .
All as per item No 30 here in before but gun metal Ball /gate valve for 25 mm dia .
All as per item No 30here in before but gun metal Ball /gate valve for 20 mm dia .
M & L for brick masonry valve pit of size 90 x90x 90 cm (internal dimensions of chamber) including 23cm thick wall built in CM 1:6, 15mm thick plain cement plaster internally in CM 1:4 and flush pointing externally as the work proceeds, PCC 1:5:10 type E2 in foundation 40mm thick PCC 1:2:4 type B-1 in floor, 50mm thick PCC 1:2:4 as coping over brick work and providing valve pit cover double door type made of 3mm thick MS sheet/plate welded with 25 x 25 x 4mm angle iron frame , provision of hinges, handle and locking arrangement including 40 x40 x 4mm iron frame fixed on top of valve pit painted with two coats of synthetic black paint over a coat of red of red oxide primer on steel work complete all as specified and directed.
M&L for disconnecting electrical/ mechanical connection and taking out submersible pump set from existing bore well approx depth varying from 110 m to 130 m with all accessories and after replacing the pipe, re-lowering the pump set in bore well with all accessories, including making connection with existing starter and testing complete all as specified and directed.
Supply and fixing of 3" dia UPVC heavy duty column pipe coupler type 3 mtr long ISI marked 30 Kg/cm2 with an adequate factor of safety high torque resistant locking system and a specially designed rubber “O” ring, column pipes have been designed to withstand system load comprising the weight of the pump, water and pipes with an adequate factor of safety complete all as specified and directed.
S&F PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 16.0 Sqmm 3 core complete all as specified and directed.
S & F Ball brass valve high pressure with polyethelen float and fly nut complete for 25mm dia pipe complete all as specified and directed.
S & F Ball brass valve high pressure with polyethelen float and fly nut complete for 20mm dia pipe complete all as specified and directed.
S & F for UPVC/CPVC 25/40 mm dia verticle pipe supporting hot dip galvanized clamping system consisting with mono braket U bolt R/M system complete all as specified and directed.
S & F in replacement sub main wiring using four single core FRLS PVC insulated, unsheathed multi stranded copper conductor cable of size 6.0 Sqmm of voltage rating upto and including 1100 Volts drawn in concealed PVC conduit or in surface conduit of dia not less than 25 mm with standard accessories, along-with one run of FRLS PVC (green colour) insulated , unsheathed, multi stranded copper conductor of size 6.0 Sqmm as earth continuity conductor complete all as specified and directed. (Note : Four run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.)
S & F in replacement sub main wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sq.mm of 1100 Volts voltage rating drawn through in rigid PVC conduit with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sq.mm as earth continuity conductor complete all as specified and directed. Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit.
S & F in replacement sheet metal powder coated versatile double door Verticle TPN 4 way distribution system as per IS 8623 with copper bus bar rated 200 amps neutral link, earth bar and din rail etc suitable for use on 415 Volts, 50 Hz supply suitable for 3P/4P MCCB as incomer complete all as specified and directed.
S&F in replacement sheet metal enclosure, double door Metalica designer distribution board flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links 4 ways TPN DBs complete complete with making good disturbed surface of walls complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosures, double door Metalica designer distribution board for using MCBs suitable for single pole and neutral, 12 way with having copper bus bars suitable for 200 amps rating complete with making good disturbed surface of walls complete all as specified and directed.
All as per item No 45 here in before but 8 way
All as per item No 45 here in before but 4 way
S & F MCB Triple pole & neutral (TPN), 32 to 63 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and directed.
Supply and fixing miniature circuit breaker (MCB) of TP and current carrying capacity 32 to 63 AMP, 415V, 10 KA 'C' curvein the MCB DB complete all as specified and directed.
Supply and fixing MCB single pole & neutral (SP&N), 20 to 40 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and directed.
Supply and fixing MCB single pole (SP) 6 to 32 Amps, 240 volts, 10KA, ‘B’ series, with proper size lugs and connections complete all as specified and directed.
Supply and fixing for MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA fixed in V TPN MCB DB as incomer complete all as specified and directed.
S & F in replacement for MCCB 4 Pole, 415 V, fixed type, 125 Amps with breaking capacity 25 KA with including IP 30 sheet metal encloser complete all as specified and directed.
S & F in replacement Single pole and neutral enclosure with a two pin and earth plug and socket complete with double pole, 250 V, 20 amp MCB complete all as specified and directed.
Taking down carefully copper/ aluminum point wiring of any size and description (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets etc , removing material for taking credit and making good disturbed surface of walls, floors, etc complete all as specified and directed.
Material and labour for point wiring for one light point or one fan point or one bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core,FRLS PVC insulated & unsheathed cable, 1100 volts grade drawn through and including concealed PVC conduit with accessories like bends, tees, junction boxes etc and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly factory made GI sheet sunken box with cover plate complete all as specified and directed.
All as per Serial item No. 56 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on same board.
All as per Serial item No. 56 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on independent board.
All as per Serial item No. 56 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/15 amps (independent) with using 2.5 sq.mm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 amps.
Supply & Fixing Modular switch 1 way 10A, 1 module complete all as specified and directed.
Supply & Fixing Modular Socket, 10A - 2/3 pin combined 2 module (with Shutter), ISI marked complete all as specified and directed.
Supply & Fixing Modular switch 1 way 20A, 1 module ISI marked complete all as specified and directed.
Supply & Fixing Socket 10A/20A - 2/3 pin combined 2 module (with Shutter), ISI marked complete all as specified and directed.
S& F Ceiling rose 3 terminal/ poly carbonate, isolated body as per existing including all electrical connection complete all as specified and directed.
S & F for Modular Bell push 6A 1 module ISI marked complete all as specified and directed.
Supply & Fixing Bell Multi Music type complete all as specified and directed.
Supply & Fixing Fan step regulator, 120W - 2 module, ISI marked compete all as specified and directed.
Disconnecting and taking up or down existing unserviceable light fitting of any description and in any position fittings complete all as specified and directed.
Fixing only servieable Surface and wall mounted light fitting of any type complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing in surface mounted round or Square shape 18 watt 230 volts AC with high efficiency PMMA diffuser light fitting including connecting & testing complete all as specified and directed.
Supply and Fix industrial compact batten suitable for twin LED Tube light with integral LED driver including making electric connection from ceiling rose to tube light fitting complete all as specified and directed by Engr in Charge.
Supply and Fix Photon Ultra LED Tubelight 20 w (single side connection) Ultra bright LED polycarbonate Tubelingt with THD < 15% with very high efficacy suited for intalltion in existing T8 Tubelingh with G 13 lamp holders to give glare free lingt complete all as specified and directed by Engr in Charge.
S & F Surface and wall mounted high efficiency 18 watt LED batten, aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver , Beam Angle 120° Lumen efficiency >110 Lm/W complete with all accessories internally pre wired and connection up with twin core flexible copper conductior cable incl LED light fixed on PVC box complete all as specified and directed.
S & F Surface and wall mounted high efficiency 8/10 watt LED batten, aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver , Beam Angle 120° Lumen efficiency >110 Lm/W complete with all accessories internally pre wired and connection up with twin core flexible copper conductior cable incl LED light fixed on PVC box complete all as specified and directed.
S & F for outdoor type IP66, Energy saving LED light fitting 30 Watt 230 V AC with PDC Aluminium body & Secondary optical lens for superior light distribution Efficacy >110 Lm/W with high pressure die cast aluminum hosing and heat resistant LED street light fitting with driver complete all as specified and directed.
S & F for Decorative, wall mounting, brushed nickel finish fixture with dual Opal Glass diffuser suitable for LED lamp B22 Base complete all as specified and directed.
Supply and fixing in round or square shape LED COB downlighter 12 watt 230 volts AC with swivel arrangement upto 90 degree recessed type suitable for roof ceiling including connecting & testing complete all as specified and directed.
S&F in replacement decorative tricolour (Saffron, white and green) LED AC rope light 120 LED/M IP 65, 15 meter length water proof, with adaptor suitable for 180 volt to 280 volt complete all as specified and directed by Engr-In-Charge.
S&F in replacement decorative LED AC rope light 60 LED/M, CCT -3000K IP 65, 30 meter length water proof, with adaptor suitable for 180 volt to 280 volt complete all as specified and directed by Engr-In-Charge.
S&F in replacement LED Post top decorative aluminium die-cast aluminiumbottom housing and spun aluminium top reflector with decorative acrylic diffuser luminary -25 watt ,IP 65 , CCT 3000K suitable for 180 volt to 280 volt, long life aesthetically designed complete all as specified and directed.
S & F in replacement of multi stranded copper conductor of size 2.5 sq.mm, 3 core PVC insulated and over all PVC Round Sheathed cable complete all as specified and directed.
M & L for laying & jointing 25 mm dia sch 40 UPVC pipe with all fittings complete to walls or laid in floors /trenches including Soil excavation not less than 0.5 mtr and returning filling testing complete all as specified and directed.
Labour only for boring under road/ drain by manual method for inserting the GI pipe tubing up to 50 mm dia cable protection complete all as specified and directed by Engineer in Charge.
Disconnecting the existing unserviceable SMC junction boxes and Supply and fix weather proof SMC junction box of outside size 300mm x 200mm x 105mm including MCB SPN, 32 Amps and MCB SP 6 Amps 01 Nos, 250 volts with cable gland etc. SMC junction box fixed on wall with 25 x 4mm new GI clamp complete all as specified and directed.
S & F in replacement post top lantern GI pipe pole made of 50 mm bore "medium grade" galvanised iron pipes with base plate complete with necessory drill hole and silver colour paint over a red oxide complete all as specified and directed by Engr-in-Charge.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5 meter below the normal ground level connected to galvanized wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron. Earth wire protected by GI pipe 15 mm bore (medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of MES Schedule Part-I including necessary concrete pit in PCC (1:3:6) type C-1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8 mm dia bar, funnel, wire mesh, 20 mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as specified and directed by Engineer - in Charge.
Material and labour for earthing complete with galvanized steel earth plate electrode 30cm x 30cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5 meter below the normal ground level connected to copper strip 20x3 mm by means of bolts, nuts, check nuts and washers of galvanised iron. Earth wire protected by GI pipe 15 mm bore (medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of MES Schedule Part-I including necessary concrete pit in PCC (1:3:6) type C-1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8 mm dia bar, funnel, wire mesh, 20 mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as specified and directed by Engineer - in Charge.
S & F copper earth continuity conductor 20X3 mm main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed.
M & L for chemical earthing complete copper earth plate of copper earth plate of 900 x 600 x 5 mm buried directly in ground) Earth pit not less than 4.0 meter below the ground level with top edge of the earth plate at a depth not less than 3.25 meter below ground level connected to test point terminal test block by means of copper nuts, bolts, check nuts & washer etc with including necessary earth work and Pre- cast RCC earth pit and cover lifting arrangement and with two coat red paint including marking the chamber as earth pit with writing of inspection test & earth result with black & white paint including dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed. Note: The rate quoted shall deemed to be inclusive of the followings. a). Excavation & earth work ( filling in, ramming in layers, watering etc as directed)in any type of soil for earth pit of size 1.2 meter X 1.2 meter X 4 meter deep. (b) 20 mm bore mild steel galvanised iron tubing light grade with funnel for watering purpose complete. (c) 40mm bore mild steel galvanized iron tubing light grade for strip protection (d) main cooper earth strip 32 x 6 mm upto 7.5 meter long or upto earth test point (f) common salt and charcoal dust in alternative layers of 15 cm up to 90cm above the top of copper plate & one layer of 15cm magnesium sulphate, ( approximate quantity of salt 500kg, charcol dust 1000kg, magnesium sulphate150 Kg, 100 Kg soil resistivity improvement powder/ GEL) complete all as specified and directed (g ) Earthing earth testing value should be less than 1.0 Ohm and this should be the sole responsibility of contractor .
S & F for Manual change over switch 400 Amps , 415 volts in sheet steel encloser complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushoning under the cable for protection of cable from being broken due to external load complete all as specified and directed by Engr-in-charge.
Supply and lay burnt brick sub class `B' old size in trenches abouting each other width equal to length of brick etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for GI pipe 50 mm dia light grade laid in trenches at road crossings/ foot paths complete all as specified and directed.
Supply and laying in replacement LT UG cable XLPE multi stranded armoured cable 3.5 Core, 95 Sq mm with aluminium conductor for working voltage upto and including 1100 volts grade, in trenches/duct/ on walls/on poles etc incl. necessary Glands of suitable size and Aluminium Lugs for fixing the cables complete all as specified and directed.
S & F new fabrication frame work for desert cooler stand made from angle iron, flat iron, Squar Tube, etc. quality confirming to Fe Gde-E 290 quality with including drilling holes, cutting , welding , bending cold or hot, polishing , in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint etc complete all as specified and directed.
M & L for 500 litres Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in any position complete all as specified and directed.
Supply & fixing PVC connection 15 mm dia 600 mm long with brass fly nut at both ends complete all as specified and directed.
S & F 16 mm dia outer dia CPVC pipes SDR-11 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S & F for Stop valve high pressure of PTMT suitable for 15 mm bore of pipe, fancy type complete all as specified and directed.
S & F for brass ball valves suitable for 15 mm bore of pipe, high pressure with polythene float and flynut complete srewed fixed in desert cooler complete all as specified and directed.
Supply, Fixing and testing for Auto change over digital timer switch 1 To 24 Hr’s programmable micro Controller Based Technology Split AC With Auto/ Manual Facility for suitable for upto 2 TR Air conditioner (for 24 hrs operation / for operation of standby AC) complete all as specified and directed.
S & F for Unplasticised PVC pipes 20 mm dia of ISI marked with tee, bend, coupler etc fixed on wall/ floor or as required as site for AC water drain pipe complete all as specified and directed.
S & F in replacement MCB single pole & neutral (SP&N), 16 to 32 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and directed.
Supply & fixing for storage water heater (Geyser) 25 Ltr of capacity verticle mounting type electric driven (single phase), not less than 5 Star rating (BEE) and grouting new suitable size anchor fastner in wall and mounting geyser on anchor fastner and writing MES No on geyser and testing complete all as specified and directed.
Supplying & fixing for switch socket outlet combination, multipurpose, three pin, 15 Amps & three pin 5 Amps controlled by one switch , flush type, 230 volts AC circuit complete all as specified and directed.
S & F Ball valve (brass inserted) of size for 20mm dia CPVC pipe complete all as specified and directed.
S & F Ball valve (brass inserted) of size for 25mm dia CPVC pipe complete all as specified and directed.
S & F for Bib taps, fancy type cast copper alloy with fancy type crutch or butterfly handle, screwed for 15 mm bore of pipe complete all as specified and directed.
S & F for round overall sheathed PVC FRLS insulated multi stranded copper conductor 4.0 Sq mm, 3 core 1100 volt grade cable drawn through with incl PVC conduit (size of as required at site but not less than 20mm) with accessories like socket , bends tees etc. fixed on recessed in wall or ceiling complete all as specified and directed.
Supply, fixing, connecting & testing 2 way sheet metal enclosures single door type for DBs with MCB single pole and neutral complete all as specified and directed.
Supply, install, testing and commissioning of solar water (Evacuated Tube Collector) based on direct transferring of heat of capacity 100 LPD solar water stainless steel tank with mounting structure and electric backup complete all as specified and directed.
Supply , installation and testing for wall mounted Digital Inverter 4 -in-1 convertible 1.5 TR 5 star rating split AC, eco frendly refrigerant with indoor & outdoor unit complete with copper condenser cordless remote air ioniser and 3D air flow, PM 2.5 air filter electric driven single Phase of capacity of 1.5TR complete all as specified and directed.
Supply & Fixing for wall mounted 15 Amp capacity digital voltage stabilizer, for automatic voltage correction single phase, naturally air cooled, indoor type, designed for or input voltage of 170 V to 270 V and output voltage stabilized between 230 V with accuracy of 2.5% complete all as specified and directed.
S & F for MCB single pole, 16 to 32 Amps (`B’ series ) having current rating 10 KA complete all as specified and directed.
Ramdev and Sons (BID ID -3189969)
DMA PROJECTS (BID ID -3190806)
Haritwal traders (BID ID -3190923)
UMIYA BUILDCON (BID ID -3189953)
ARTI CONSTRUCTION (BID ID -3190651)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .