| Sl No | Description | Qty | Unit | GLOBAL PROJECT L2 | Kavery Electricals L1 |
|---|---|---|---|---|---|
| 1.00NON BSR ITEMS | |||||
| 1.01Supply, installation, testing and commissioning of factory fabricated Double Skinned DX Coil Air- handling unit fabricated out of extruded aluminum section with 0.8mm pre-plasticized / pre-coated Galvanized steel sheet outside & 0.8 mm polished SS sheet inside complete with supply & exhaust blower section with single / multiple AMCA certified backward curved plug fan with aerofoil design blades, VFD with built in harmonic filters for both supply & exhaust fan motor, power control panel with necessary switchgears incoming & outgoing for VFD, HRW & humidifier, blower suitable for static pressure as required (Fan Static given below is for guideline), blower motor TEFC (IE3) type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 8 row cooling & 2 row heating coil made of Aluminum finned Copper tube, Copper header with coil section, pre-filter section with non woven synthetic media MERV 8 filters in extruded aluminum frame in both the supply & exhaust side of AHU, fine filter section with MERV 13 filters in extruded aluminum frame in supply after fan, (Hepa filters shall be at terminals along with laminar flow plenum & not to be included in the cost), Heat Recovery Wheel with HRW Section, mixing chamber, polished stainless steel drain pan made out of 22 G sheet duly insulated etc. without face and bypass dampers, coilotron UV section only of 600 mm in length in floor mounted AHU (Coilotron UV System quantified separately). The AHU panels shall be insulated with 48mm thick & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminum extruded section only. These AHUs shall have air inlet / outlet connection made of aluminum 20 G & all fixing arrangement / blank off shall be of SS The complete AHU shall conform to standard speciation. The face velocity across cooling / heating coil shall be limited to 152 MPM maxm. The capacity of Air-handlers shall be as follows: | |||||
| 1.02 | 2800 CFM (7.0 TR ) ESP - 120 mm | 2 | Nos. | 2,99,000 ₹5,98,000 Lowest | 2,99,500 ₹5,99,000 |
| 1.03 | 2000 CFM (5.0 TR ) ESP - 120 mm | 1 | Nos. | 2,24,800 ₹2,24,800 Lowest | 2,25,000 ₹2,25,000 |
| 1.04 | Supply, installation testing, commissioning and validation of Laminar Flow Units (LFU) comprising of Terminal EU 13 HEPA Filters of 99.997% Efficiency down to 0.3 Micron particle size installed in zero leakage Al frame with Al perforated plate type Al grille, LFD laminar flow diffusers are constructed from 18 swg aluminium
sheet, perforated face with approx. 50% perforation of size 900x600mm-6nos, 600x600mm-3nos, including the cost of supply air 18 gauge Al plinum of size 8'x6'x2', including all connection complete in all respect. Make as approved by Engineer in charge. | 3 | Each | 1,38,500 ₹4,15,500 Lowest | 1,60,000 ₹4,80,000 |
Tender Value
₹2.0 Cr
EMD Value
₹4.0 L
Closing Date
28 May 2026, 6:00 pmClosed
Executive Engineer, Medical and Health, Div. Alwar
CMHO Office, Near Nangali Circle, Alwar
SITC of HAVC work in SDH Sikrai, Distt. Dausa
2026_MEDIC_560415_1
NIT NO. 04/2026-27(03)eemhalwar
Open Tender
Electrical Works
Percentage
180 days
DAUSA
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
BOB, A/C No. 06680100019402, IFSC - BARB0ALWARX
₹4.0 L
11 Jun 2026
19 May 2026
29 May 2026
19 May 2026
28 May 2026
19 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1NON BSR ITEMS | |||||
| 1.01 | Supply, installation, testing and commissioning of factory fabricated Double Skinned DX Coil Air- handling unit fabricated out of extruded aluminum section with 0.8mm pre-plasticized / pre-coated Galvanized steel sheet outside & 0.8 mm polished SS sheet inside complete with supply & exhaust blower section with single / multiple AMCA certified backward curved plug fan with aerofoil design blades, VFD with built in harmonic filters for both supply & exhaust fan motor, power control panel with necessary switchgears incoming & outgoing for VFD, HRW & humidifier, blower suitable for static pressure as required (Fan Static given below is for guideline), blower motor TEFC (IE3) type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 8 row cooling & 2 row heating coil made of Aluminum finned Copper tube, Copper header with coil section, pre-filter section with non woven synthetic media MERV 8 filters in extruded aluminum frame in both the supply & exhaust side of AHU, fine filter section with MERV 13 filters in extruded aluminum frame in supply after fan, (Hepa filters shall be at terminals along with laminar flow plenum & not to be included in the cost), Heat Recovery Wheel with HRW Section, mixing chamber, polished stainless steel drain pan made out of 22 G sheet duly insulated etc. without face and bypass dampers, coilotron UV section only of 600 mm in length in floor mounted AHU (Coilotron UV System quantified separately). The AHU panels shall be insulated with 48mm thick & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminum extruded section only. These AHUs shall have air inlet / outlet connection made of aluminum 20 G & all fixing arrangement / blank off shall be of SS The complete AHU shall conform to standard speciation. The face velocity across cooling / heating coil shall be limited to 152 MPM maxm. The capacity of Air-handlers shall be as follows: | - | - | - | - |
| 1.02 | 2800 CFM (7.0 TR ) ESP - 120 mm | - | Nos. | - | - |
| 1.03 | 2000 CFM (5.0 TR ) ESP - 120 mm | - | Nos. | - | - |
| 1.04 | Supply, installation testing, commissioning and validation of Laminar Flow Units (LFU) comprising of Terminal EU 13 HEPA Filters of 99.997% Efficiency down to 0.3 Micron particle size installed in zero leakage Al frame with Al perforated plate type Al grille, LFD laminar flow diffusers are constructed from 18 swg aluminium
sheet, perforated face with approx. 50% perforation of size 900x600mm-6nos, 600x600mm-3nos, including the cost of supply air 18 gauge Al plinum of size 8'x6'x2', including all connection complete in all respect. Make as approved by Engineer in charge. | - | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
Tendernotice_2.pdf
PDF • 7.07 MB
Tendernotice_3.pdf
PDF • 1.73 MB
tenderdocs_3.pdf
Tender Documents • 0.40 MB
Annexure_DLP_Condition.pdf
Other Document • 0.42 MB
BOQ_997536.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .