Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC being L1 bidder | |
| 2 | L2₹37.7 L+₹4,730 (0.13%)Rejected-Finance | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹45.9 L+₹8.2 L (21.7%)Rejected-Finance | L3 | Rejected-Finance Being L3 bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (W)
GE (W) Hisar Hisar Mil Stn PIN-125006
GE (W)/HSR-16/2024-25 REPAIR REPLACEMENT CLEANING AND CONNECTED ITEMS OF SEWAGE LINES AT OTM JCOs OR MD ACCN OF ZONE A
2024_MES_652288_2
GE (W)/HSR-16/2024-25
Open Tender
Civil Works
Item Rate
270 days
HISAR
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (W) HISAR
₹98,000
GE (W) HISAR
10 Oct 2024
3 Jul 2024
6 Sept 2024
3 Jul 2024
4 Sept 2024
17 Jul 2024
4 Jul 2024 - 12 Jul 2024
12 Jul 2024
Amount
Attending day to day complaints for cleaning of blockage from floor/Nahani trap, soil waste pipe, WC, chocked rain water pipe etc upto and including 1st manhole and removing sludge water/waste upto 50 metre distance and burring the same in pit complete all as specified and directed. Note :- (i) The unit rates quoted in above items shall deemed to be included for removing of solids, liquids and sludge etc of any description from manholes (ii) OTM & MD accn of Offrs and JCOs/OR ,,and all other type of accn incl MES Colony in Zone 'A' area under AGE B/R-II of GE(W) at Hisar Military Station (iii) All indls will report at complaint cell of AGE B&R-II of GE (W) Hisar alongwith a supervisor deputed by contractor to concerned indl will take attendance on daily basis. (iv) Contractor will collect the collect the complaint slip & submit the same in the evening after attending the complaints. (v) In case of any complaint is not attended by contactor withing 24 hours of reporting, then compensation @ Rs. 50.00 (Flat rate) will be deducted and Rs. 20.00 extra in addition to initial penalty of Rs. 50.00 for each further 24 hours delay.
Cleaning of underground sewage line of any type and size up to and including 200 mm dia all in working and running condition involving removal of blockages of any kind in sewage lines by means of either by mechanical rodding or with manual rodding with vibration /drilling concept ie trolley mounted motorized sewer cleaning machine including desluding descaling & dechoking of line wherever required, flushing the entire stretch with whatever way possible including combined high pressure water jetting com suction (vaccume )type machine suitably fabricated on HCV having facilities of hydraulic application through high pressure thermoplastic, making the stretch clean, functional and removal /deposition of sludge inclusive of solids of any type & sludge water to a distance exceeding 1.5 km but not exc 5 km and covering the entire sludge and solids with local earth complete all as specified and directed.
Description all as per item No 2.00 above but exc 200 mm and upto 600 mm bore sewage line complete all as specified and directed.
Cleaning of manholes n. exc. 3mtr deep by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and depositing where directed including covering the same with at least 30cm thick layer of soil complete all as specified and directed.
Description all as per item No. 4.00 above but depth exc. 3mtr but n. exc. 6mtr complete all as specified and directed.
Complete Dewatering/Desilting /De-sludging of Septic tank /Manholes of any size and any type by removing all sludge both organic or inorganic in nature by vacuum process closed tanker tractor driven and disposing off the same to a distance exceeding 1.5km but not exe 5km at places as complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description below ground level complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Demoliton of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing debries out of MD land complete all as specified and directed.
M & L for Brick work with burnt Bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 for Manhole , GT etc complete and all as specified and directed.
M & L for Brick work of old size Bricks , straight or curved on plan to any in half brick thick walls , built in cement mortar 1:4 complete and all as specified and directed.
M&L brickwork with sub class 'B' old size brick laid on edges in floor in drain bedded and jointed in cement and sand mortar (1:6) and all as specified and directed
M&L Flush pointing to brick walls/floors, surface channels, drains, roofs etc in cement mortar 1: 3 finished even and smooth complete all as specified and directed.
M&L Racking out joints/ Pointing to brick work in wall or bricks on edge in floors, surface channels, drains, roofs etc and pointing to brick walls in cement mortar 1: 3 finished even and smooth complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement) in cement plaster 1:4 complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement) in cement plaster 1:4 complete in Sunken part of backside of Bldg including taking down of existing plaster complete all as specified and directed.
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in coping & benching including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work, finished even and smooth using extra cement complete all as specified and directed.
M&L plain cement concrete type B1 1:2:4 (20 mm graded aggregate) in Bed to drain and mass concrete complete all as specified and directed.
M & L for cleaning drain upto 01 m wide including removing of all sludge, mud, foreign material, sand, ashes, fibre, silt, grease, night soil etc and removing the taken out sludge /material out side of MD land by any means/source complete all as specified and directed.
M&L for precast casting reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs for manholes / GT (square / rectangular / circular ,cover slab over drainage line of any type and size with Angle iron bend to shape of manhole etc, shelves and similar articles with plain faces including necessary formwork and setting in cement mortar 1:4 including necessary use and waste of formwork and demolition of existing RCC cover slabs if any and complete all as specified and directed.
Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Mild steel TMT bars 6 to 8 mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m and n exc 3 m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
S&F 150 mm bore reinforced concrete pipe calss NP3 laid and jointed completed with collars in trenches or in floors including demolition and breaking up existing pipes of any type complete all as specified and directed.
S&F 200 mm bore reinforced concrete pipe calss NP3 laid and jointed completed with collars in trenches or in floors including demolition and breaking up existing pipes of any type complete all as specified and directed.
S&F 300 mm bore reinforced concrete pipe calss NP3 laid and jointed completed with collars in trenches or in floors including demolition and breaking up existing pipes of any type complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm dia pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 200mm dia pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 300mm dia pipe complete all as specified and directed.
Cutting into existing manholes for connecting new drains, 100mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and directed.
Cutting into existing manholes for connecting new drains, 150mm and above all bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete.
M&L for hard core of broken bricks of gauge nexc 63mm deposited and spread and levelled in layers nexc 15cm tick watered and rammed to a true surface in Backside of Bldg of Joginder Vihar & MES Colony & zone A incl of prepairing the surfaces by cleaning of vegetation ,debris, broken bricks, demolished concrete waste,soils of any type by any means and removing the same out of MD land and levelling the surface and complete all as specified and directed.
M&L for 75 mm Cement concrete type D 2, 1:4:8 (using 40 mm graded graded stone aggregate) as in sub base of flooring/ hard standing in Backside of Bldg of Joginder Vihar & MES Colony and Zone A incl of prepairing the surfaces by cleaning of vegetation ,debris, broken bricks, demolished concrete waste,soils of any type by any means and removing the same out of MD land and levelling the surface and complete all as specified and directed.
Supply and fixed 60 mm thick machine pressed precast interlocking coloured (min 2 shades )paver block of any size and shape confirming to IS 15658-2006 of Grade M-35 placed over sand cushioning made up with 12.5mm graded mechanicaly crushed stone aggregate, factory made of any tint, over and including filling the joints with coarse sand complete all as specified and directed. Note:- Sand cushioning shall be measured and paid separately inclusive 25mm thick sand cushioning.
M&L Chequered cement concrete tiles 25 cm X25 cm X 25 mm thick over 15 mm thick bedding of CM 1:6 in floors ,set,jointed and pointed in neat cement slurry with gray cement and pigment and complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B1 as in flooring and complete all as specified and directed.
M&L Pre-cast cement concrete Type B1 1:2:4 (20 mm graded aggregate ) kerb Stone ,setting in CM 1:4 and complete all as specified and directed.
S&F non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) tiles oof size 400 x 400 mm in floors, over and including 15 mm thick screed in CM (1:4) set and jointed in neat cement slurry and pointed flush with white or coloured Epoxy to match and complete all incl dismantling of tiles incl cement morter bedding complete all as specified and directed.
S&F 110 mm bore PVC RWP pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps incl taking down old unsv pipe of any type complete all as specified and directed.
S&F 110mm dia PVC bend any radius including benching of bends provided at ground surface in PCC 1:3:6 and complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps incl taking down old unsv pipe of any type complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps incl taking down old unsv pipe of any type complete all as specified and directed.
S&F 110 mm PVC (SWR) access door bends any radius complete all as specified and directed.
S&F 75 mm PVC (SWR) access door bends any radius complete all as specified and directed.
S&F 110mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed.
S&F 75mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed.
S&F 110mm PVC PVC (SWR) vent cowl complete all as specified and directed.
S&F, PVC Nahani trap 75mm bore with grating incl jointing with solvent cement fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
Treatment of sunken floor slab compraises of the following specifications and complete all as specified and directed :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout. (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with liquid water proofing compound @ 200ml per 50 Kg beg of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out (fixing of nozzle and grouting & WPC will be measured and paid separately). (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (vi) GI pipe 50mm dia medium grade 50cm long laid on each sunken floor as spout complete all as specified and direced by EIC. (vii) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with liquid water proofing compound @ 200ml per 50 Kg beg of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured and paid separately) (viii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 type C-1 all round after painting with anticorrosive paint. Note :- (i) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is included in the rates quoted above. (ii) All debries obtained from site will be thrown away out side MD land by contractor at his own expense. (iii) For payment purpose the plan area of sunken floor shall be taken into accounts.
S&F in repair vitreous china squatting pan "ORISSA" pattern size 580mmx440kmm, white with integral foot rest including cast iron 'P' or 'S' trap and connection to trap includintg cement concrete, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor complete all as specified and directed.
S&F in repair, PVC flushing cistern 10 lir capacity, valveless, syphonic action type with float, handle incl 32mm dia flush pipe of polyethylene of low or high density or PVC & bracket etc complete all as specified and directed.
M/S Sulakh Brothers (BID ID -3081323)
M/s Jai Hanuman Construction (BID ID -3072709)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .