| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC | ₹38.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹42.2 L+₹3.8 L (9.87%)Rejected-Finance HOUSE NO 415 ALIKAN ROAD MANDI DABWALI SIRSA HARYANA 125104 | MANDI DABWALI | SIRSA | HARYANA | 125104 | ₹42.2 L+₹3.8 L (9.87%) | L2 | Rejected-Finance Quoted other than lowest rate. |
| 3 | L3₹42.4 L+₹4.0 L (10.4%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹42.4 L+₹4.0 L (10.4%) | L3 | Rejected-Finance Quoted other than lowest rate. |
| 4 | L4₹43.4 L+₹5.0 L (13.1%)Rejected-Finance | ₹43.4 L+₹5.0 L (13.1%) | L4 | Rejected-Finance Quoted other than lowest rate. |
| 5 | L5₹43.5 L+₹5.1 L (13.4%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹43.5 L+₹5.1 L (13.4%) | L5 | Rejected-Finance Quoted other than lowest rate. |
Tender Value
₹44.2 L
EMD Value
₹88,400
Closing Date
7 Jun 2024, 6:00 pmClosed
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA Pin-151004 C/o 56 APO
SPL REPAIR/ REPLACEMENT OF CEILING FANS AND GEYSERS AGAINST BER, PROVN OF GEYSER, EXHAUST FAN, CEILING FAN, SOLAR WATER HEATER AND ISOLATION TRANSFORMER CAPACITY 10 KVA UNDER AGE E/M -V OF GE (N) BATHINDA AT BATHINDA MIL STN
2024_MES_654421_1
8939/NIT-09/24-25
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
BATHINDA
Class D Category b(i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹88,400
Yes
3 Sept 2024
17 May 2024
10 Jun 2024
17 May 2024
7 Jun 2024
31 May 2024
17 May 2024 - 23 May 2024
Amount
E/M Works
Supply and fixing in provision of BLDC (Brushless direct current motor) ceiling fan 5 star rated, complete with blades, down rods, and accessories, 230 Volts, 1200mm sweep, Min air delivery 210 CFM with service value 6.00 BEE, including electrical connection providing twin core round copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Srl Number of ceiling fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Ceiling fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing of PVC insulated, unseathed multistranded, three core twisted copper flexible cable of size 1.5 sqmm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed point wiring complete with 1.5 sqmm (nominal cross section area ) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked ) drawn through and including PVC rigid conduit 20mm dia( heavy duty ) with all fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken boxe of suitable size (min 60mm deep, suitable length and 1.2mm thick ), 3mm thick bakelite plastic laminated sheet for mounting switches and socket ,fan regulator, for light/fan point controlled by one switch, top cover fixed with brass screws & cup washers including provn of 1.5 sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good distrubed surface of wall/ceiling/floors etc by using CM (1:3 ) to matching with existing surface, complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch piano flush type, single pole,one way, 5/6 Amps ISI mark, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose 3 plate flush type 6 Amp 250V AC topline series with polycarbonate 20 X 50 mm two to three terminal, complete all as specified and directed by Engineer-in-charge.
Supply and fixing Fan regulator modular Electronic step type (1-4), socket type 230- 240 volt AC supply, complete all as specified and directed by Engineer-in-charge.
Supply and fixing in provision of storage type water heater (Geyser) electrical operated 230/240 Volts 25 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, plug top, etc. required for proper functionality & including electric/earth connections complete all as specified and directed by Engineer-in-Charge. Note :- (i) Srl Number of Gyeser and 'GE North BTD' shall also be writing on Gyeser with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Gyeser installed at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account.
Supply & fixing 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply & fixing stop valve/angle valve cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing in provision of (concealed in wall or as directed) single pole and neutral sheet metal enclosure (geyser Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 25 Amps, 240 volts, AC supply, complete all as specified and directed by Engineer-in-Charge.
Material and labour for fixing of 4 Nos rawl plug of suitable size (4"-6") nuts & bolts, grouting work in RCC/Brick wall, cemented works labour charges for cutting to exisiting GI pipe line of size 15 mm dia in position for insertion of tee or branch connection jointing complete with necessary GI fittngs, plumbing work all as per site requirement.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Labour for cutting of existing GI pipe of size 25/20 mm dia in position for addition/alteration or insertion of TEE for branch connection complete with cutting, threading and jointing/fixing including GI fitting as per requirement
Material and labour for Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH with continuous copper earth conductor of 4 sqmm in & including PVC conduit size 20mm complete all as specified and directed by Engineer-in-charge.
Supply and fixing of exhaust fan steel body 450 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing in provision of (concealed in wall or as directed) single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 63 Amps, 240 volts, AC supply, complete all as specified and directed by Engineer-in-Charge.
Supply, install, testing and commissioning of 'Solar Hot Water System' (flat plate collector) based on indirect transfer of heat of capacity 300 LPD including stand complete all as specified & directed by Engr-in-charge. Note :- Rate of solar water system includes the cost of backup stainless steel hot water tank only insultated but does not include the cost of cold water tank, cold water piping and hot water piping.
Supply, install, testing and commissioning of 'Solar Hot Water System' (flat plate collector) based on indirect transfer of heat of capacity 200 LPD including stand complete all as specified & directed by Engr-in-charge. Note :- Rate of solar water system includes the cost of backup stainless steel hot water tank only insultated but does not include the cost of cold water tank, cold water piping and hot water piping.
Material and labour of Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore complete all as specified & directed by Engr-in-charge.
Supply & installation, commisioning and testing of 10KVA Isolation transformer single phase, air cooled, complete all as specified & directed by Engr-in-charge. Technical specification :- capacity/rating : 10KVA Input voltage : 230V Single phase,50Hz Output voltage : 230V Single phase,50Hz Conductor : single electrolytic copper core : CRGO M-4 Grade, LOW LOSS LAMINATION INSULATION : CLASS F Regulation : +/-5% Coolong : Dry type, natural air cooled Temperature : 50 deg C (above ambient) Duty cycle & use : 24x7 continuos, Indoor C.M.N.R. : 100 db Load regulation : better than 3.5% Insulation resistance : more than 5 mega Ohms Dielectric strength : 25000V AC fro 60sec Leakage current : less than 50 microA Efficiency : 97% Reference standard : IS:2026
Supply & fixing of copper strip 20 x 3.15mm buried in ground with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engr-in-charge.
Supply & fixing of Test point of MS sheet of terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engr-in-charge.
Material and labour of chemical earthing with copper plate electrode 90×60cm ×5mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below normal ground level) with top edge of the plate vertically to depth of not less than 1.5 mtr below normal ground level sourrounded from all sides with alternate layers of copper sulphate chemical, coat dust and common salt, connected to and including copper strip as size 32x6 mm earth lead connected by means of MS bolts, nuts washer & check nuts etc connected to earth test point/ main control board including 40 mm dia light grade GI pipe for protection to extent 7.5 mtr as earthing lead and GI pipe 20 mm bore for watering including providing funnel and wire meash, 10 mm thick CI cover hanged to CFI frame PCC chamber pit with PCC 1:3:6 type C-1 using 20 mm graded stone aggregates complete all as per electrical plate No 3 of SSR Part - I of 1991 including excavation and earth work in any type of soil and testing on completion all as specified. Note : PCC chamber shall be constructed at least 1.5m away from earth pit pipe for watering shall be provided in slanting manner complete all as specified and directed by Engr-in-charge.
SIGMA ENGINEERS AND CONTRACTORS
M/s Rohit Construction Co.
M/s DHEERAJ JAIN CONSTRUCTION COMPANY
M/s badrinath Traders
M/s VISHAL ELECTRIC STORE
M/s PANKAJ KUMAR
M/s MITTAL CONSTRUCTIONS
SATTYAM BUILDERS
SWARN SINGH AND CO.
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .