| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.0 L+₹2.2 L (8.06%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹30.6 L+₹3.8 L (14.0%)Rejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹31.9 L+₹5.1 L (18.9%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in relevent category b(ii) |
Tender Value
₹24.9 L
EMD Value
₹50,000
Closing Date
3 Jan 2023, 6:00 pmClosed
CWE Hisar
HQ CWE Hisar Hisar Mil Stn Hisar
REPAIR/REPLACEMENT OF HT/LT OH HT/LT U/G CABLES LT PANELS TRANSORMER INCL ALLIED WORKS AT EBS, BHOJRAJ AND (ASCON NODE) CHHANIBARI UNDER GE (W) HISAR
2022_MES_557177_2
CWE/HSR-30 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Hisar Military Station
As per tender document
9 documents required · 9 mandatory
₹500
GE(W) Hisar
₹50,000
16 Jan 2023
13 Dec 2022
5 Jan 2023
13 Dec 2022
3 Jan 2023
27 Dec 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable etc. and for foundation of poles, stays etc. n exc 10 sqm on plan and n exc 1.5 in depth and getting out complete all as specified.
Description all as per Serial item No 1 above but Add to item 1 for each additional 1.5m or part thereof in depth beyond the first 1.5 mtr complete all as specified and directed.
Returning filling with earth obtained from excavation including spreading, watering & consolidation in layers not exceeding 15 cms thick, complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m & depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material & labour for Sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete all as specified and directed.
Material & labour for bricks covering to under ground electric cable using sub class 'B' bricks laid dry, flat, perpendicular to the direction of the cable complete all as specified and directed.
Dismantling of old broken PCC pole of any size including foundation and removing the same from site complete all as directed by Engineer-in-charge.
Supply errecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 9 mtr long,102 mm x 172 mm at top and 102 mm x 279 mm at bottom,class 10 complete as specified & directed (Note : Earth work & PCC shall be measured and paid separately)
Material & labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate . in mass concrete and filling complete for foundation of pad of pole all as specified & directed.
Material & labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate . in mass concrete and filling complete for foundation of Panel & Transformer yeard, pole/stay/ of pole all as specified & directed by Enge-in- Charge
Material & labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping for replacement of new pole and breaking old existing coping and like including weather slightly rounded or chamfered angles and throaty and necessary form work complete for pole ,all as specified and directed .
Supply and fixing in replacement stay assembly comprising of GI stay bow 14 mm dia, 40 cm long complete with accessories as shown in Electrical plate No. 1 of SSR Part – I using galvanised stay rod 20mm dia, 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30 cm x 30 cm x 6 mm thick 2 Nos of thimbles, MS clamps made out of 50x6mm flat iron, loop stay insulator, stay wire 7/8 SWG complete including painting all exposed surfaces of MS work shall be given two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge. Note :- PCC and earth work shall be measured and paid for separately under the respective item of schedule)
Supply and Stretching in replacement Aluminium conductor steel reinforced (ACSR) of any size for HT/LT OH lines on poles including stringing ,binding with aluminium wire 14 SWG or aluminium tape incl jumpers complete connecting of disconnected cable, service cable and street light connection complete all as specified and directed.
Supply and Stretching in replacement 4mm dia GI earth wire/guard cradles on existing LT poles binding with and including GI binding wire 1.63 mm complete all as specified and as directed.
Supply and fixing in replacement of insulators pin type porcelain, vitreous ,white or brown or green insulator of size 50 mm height, 65 mm dia suitable for 1100 V grade including one galvanized mild steel spindle, two GI washers and one nut including removing the existing unserviceable one complete all as specified and directed.
Supply and fixing in replacement of shackle type ,procelain, vitreous, white,brown, or green insulator of size 75mm height and 90mm dia suitable for 1100V, including Galvanised MS straps,washers, insulator bolts,washers and nuts complete,all as specified and as directed.
Material & labour in replacement of Cross Arms bracings supports, channels, clamps, anti climbing device, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps nuts, bolts , washers,welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Re-stringing/stretching incl jointing in situ of different sizes of ACSR conductors or GI earth continuity conductors with/ without guarding wires on HT/ LT electric poles at different locations all as ordered manually or by mechanical means to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium binding wire or aluminium tapes after stringing complete all as specified and directed. Note :- (a) Stretching of 4 conductor will be considered as one span length for measurement purpose. (b) Qty of GI earth wire or ACSR conductor reqd to be replaced or extended during stringing operation shall be measured and paid separately.
All as per item No-18 above but 5 conductor complete all as specified and directed.
All as per item No-18 above but (1or 2) conductor complete all as specified and directed.
Cutting/trimming the branches of trees if any along HT/LT overhead line, 1.5 mtr on all side below/above/sides of HT/LT overhead line and removing the same upto 150 mtr away each span not exceeding 40 mtr complete all as specified and directed by Engineer-in-Charge (The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required).
Supply and fixing installation, commissioning and testing in replacement of MCCB 400 Amps fixed on existing panel 415 volt, 4 pole, 36 KA breaking capacity with adjustable current range for overload protection and thermal release including taking down of MCCB complete with spreader terminals all as specified & directed.
All as per item 22 here-in- before but 200 Amps, 4 pole 25 KA complete all as specified and directed.
All as per item 22 here-in- before but 160 Amps, 4 pole 25 KA complete all as specified and directed.
All as per item 22 here-in- before but 125 Amps ,4 pole,415 volts 25KA breaking capacity complete all as specified and directed..
All as per item 22 here-in- before but 100 Amps ,4 pole,415 volts 25KA breaking capacity complete all as specified and directed..
All as per item 22 here-in- before but 63 Amps ,4 pole,415 volts 16KA breaking capacity complete all as specified and directed..
Supply & fixing in replacement main switch DP 32 Amps 240 Volt fixed on pole/panel/wall etc including making connections with existing cable at site complete all as specified and directed.
Taking down unserviceable/old LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable of any size and removal from site complete all as specified and directed.
Relaying of old serviceable LT/HT under ground PVC/XLPE cable any grade and any size in trenches/fixed to wall/pole/roof/laid in floor including necessary connections and thimbling complete all as specified and as directed by Engineer-in-charge. (Earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item).
Supplying laying, jointing, testing and commissioning of LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of the 185 Sqmm 3.5 core all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc.Execavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
All as per item 31 here-in- before but 150 Sqmm 3.5 core complete all as specified and directed.
All as per item 31 here-in- before but 120 Sqmm 3.5 core complete all as specified and directed.
All as per item 31 here-in- before but 70 Sqmm 3.5 core complete all as specified and directed.
All as per item 31 here-in- before but 50 Sqmm 3.5 core complete all as specified and directed.
All as per item 31 here-in- before but 35 Sqmm 3.5 core complete all as specified and directed.n
All as per item 31 here-in- before but 25 Sqmm 3.5 core complete all as specified and directed.
All as per item 31 here-in- before but 16 Sqmm 3.5 core complete all as specified and directed.
All as per item 31 here-in- before but 10 Sqmm 3.5 core complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode size 600x600x6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40 mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
All as per item 40 here-in- before but GI wire 4 mm as earthing lead
M & L for replacement for PVC separator in position to keep ACSR conductor on equal spacing all as specified & directed. (a) 2 Wire
M & L for replacement for PVC separator in position to keep ACSR conductor on equal spacing all as specified & directed. (b) 3 wire
M & L for replacement for PVC separator in position to keep ACSR conductor on equal spacing all as specified & directed. (c) 4 wire
M & L for replacement for PVC separator in position to keep ACSR conductor on equal spacing all as specified & directed. (d) 5 Wire
Material & Labour for replacement of GI strip 32 mm x 6 mm from test point upto equipment to be earthed with connecting material like nut bolts etc complete all as specified and directed.
Material & labour for replacement of 80 mm bore GI pipe light grade laid in trenches or fixed to wall/pole for protection of cable/earthing strip etc complete all as specified and directed.
Material & labour for replacement of 50 mm bore GI pipe light grade laid in trenches or fixed to wall/pole for protection of cable/earthing strip etc complete all as specified and directed.
Material and labour for making the hole under road and hard standing suitable for laying and inserting pipe upto 100 mm dia any length by trenchless technology, mechanical drill system or Auger system and making the surface good as existing surface.complete all as specified and as directed by Engineer-in-charge.
Surface Dressing/Cutting of grass,bushes,shrubs and wilds n exc.15 cm deep and removing the same from the site to clear the area of dressing complete all as specified and directed. (The above is to be ensured for the entire contract period for any number of times as required).
Supply installation, connecting and testing in replacement of gang operated air break switch, mounted on insulators HT 11KV ,200 Amps rating , triple pole,twelve insulator suitable for horizontal mounting fixed and spring loaded revolving tinned brass/copper copper contacts, galvanized steel base frame, 32 mm bore med grade pipe Galvanized operating rod(Medium Grade), operating handle, locking arrangement complete including taking down the existing gang operated air break switch complete all as specified and directed. (i) Cross arms of 2 pole/4 pole structure reqd for installation of GO switch,if reqd additional, shall be measured and paid seperately. (ii) Scope of wk shall include ACSR conductors PVC sleeves, PG clamps and thimbles reqd for jumpers/connections to OH lines of 2 poles/ 4 poles structures and outgoings feeders.
S & F in replacement lightening arrester metal oxide non-linear expulsion type rupturing capacity 65 KA, porcelain, conforming to IS-3070 Pt-I suitable for 11 KV, HT over head line complete including nuts, bolts, clamps, brackets etc and connecting with GI earth wire, discharge capacity 65 Kilo Amps.
Supply and installation replacement of drop out fuse assembly 11KV,25 Amps rating complete expulsion fuse element mounted on four/two pole structures all as specified and directed.
Repairs to existing two/ three/Four pole gang operated air break switch horizontal/vertical throw incl taking down old unsv male/female contact set and providing in replacement new male female contact set copper ,spring loaded suitable for 200 Amps complete with jumpers from GOD to OH line & DO to GOD complete with thimbles incl HT tape reqd for repairing HT end termination joint icluding reuired GI pipe rod nd handle complete all as specified and directed.
Supply and fixing in replacement of insulators pin type porcelain, vitreous ,white or brown or green insulator of size 150 mm height, 150 mm dia suitable for 11 kV grade including one galvanized mild steel spindle, two GI washers and one nut including removing the existing unserviceable one complete all as specified and directed.
Supply and fixing in replacement of single Disc insulator assembly for tension with tension clamps for conductors, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green with tension clamps for conductors, working pressure 11 kV for disc assembly complete,all as specified and as directed.
Supplying laying, jointing, testing and commissioning of XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11000 volts grade, cross sectional area 95 Sqmm 3 core suitable for 11 KV earthed systems complete all as specified and directed by Engr -in-Charge. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc . Excavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid separtely) .
Material & labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination Cold shrinkable type joint complete with jointing material and accessories suitablae for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm complete all as specified and directed.
Material & labour in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled Red, with letters, figures, and coventional skull and bones, in signal white colour and fixed with MS CLAMPS, bolts, and nuts of approved size, for HT 25 X 20 Cm size complete all as specified and directed.
Material & Labour Painting to HT PCC pole with fluorescent post office red and black synthetic enamel paint at a distance of 30 cm wide complete all as specified and directed.
All as per item 60 here-in- before but on PCC 2 pole structures painting of bracings.
All as per item 60 here-in- before but on PCC 4 pole structures painting of bracings.
All as per item 60 here-in- before but on 33/11 KV 2 pole structures including painting of iron angle structures and bracings.
Material & Labour Painting to LT PCC poles with fluorescent Black and White synthetic enamel paint at a distance of 30 cm wide complete all as specified and directed.
Dismantling insulator any type/ any size from LT/HT poles complete all as directed.
Dismantling unserviceable concrete pole/struts of any size and removing from site .
Dismantling unserviceable stay assembly complete and removing from site
Dismantling unserviceable cross arms, clamps etc and removing from site
Dismantling unserviceable galvanized earth steel wire of any size and existing hexagonal cradle guard HT/LT poles and removing binding wire and removal of the same from site complete all as specified and directed.
Taking down unserviceable/old ACSR conductor any size from over head lines, poles by removing binding wire, service wire, cables and removal from site complete all as specified and directed.
Dismantling of air break gang operated switches/ DO assembly vertical/horizontal mounted including insulators and operating mechanism and removing the same from site and carrying to MES store complete all as specified and directed.
Servicing of 33 KV SF6 panel, Make ABB, Rated Voltage - 36 kV, cleaning of all carbon particles, dust etc complete and cleaning of all parts, adjusting contacts, springs, locking arrangements, tripping coil circuits (closed/ open) CRC spray for elect contact cleaning etc cleaning of CT and PT supporting insulators, bush trolley auxiliary contact, male female contact Charging motor and check all wiring including all minor item required for repair complete all as specified and directed. Note:- 1.The rate quoted in this item are excluding testing and adjusting / Calliberation of relay including checking and rectifying the tripping circuit complete.
Supply and fixing in replacement Annunciator for 33/11 KV SF6 Panel to control the alarm & Tripping acc to specify range of winding temp, oil temp and Bucholz relay complete all as specified and directed.
M & L for testing and adjusting the following relay including checking and rectifying the tripping circuit complete, Calibration of relay for 33 KV incoming panel. (a) Master Trip relay, Make-ABB – 01 No (b) Relay for Over current & earth fault, Make-Schnider - 01 No (c) Relay for Winding temp high alarm, Winding temp high trip, Make-ABB – 01 No (d) Relay for Oil temp high alarm, Oil temp high trip, Make-ABB – 01 No (e) Relay for Bocholz Relay alarm, Bocholz relay trip, Make-ABB – 01 No Note: - (I) The tripping system of relays are to be calibrated with 33Kv receiving station DHBVN Hisar and test result in this effect to be submitted to Engr-in- Charge (II) The tripping timing of the relay to be adjusted less than 33KV system at DHBVN Hisar (III) The testing instrument whatever required to test the relays will be arranged by the contractor at his own cost (IV) The test shall be provided from authorized agency.
Servicing of 11 KV VCB,current rating - 100 Amp/ 60 Amp, Type -UNIVAC, cleaning of all carbon particles, dust etc complete and cleaning of all parts, adjusting contacts, springs, locking arrangements, tripping coil circuits (closed/ open) using CRC spray for elect contact cleaning etc cleaning of CT and PT supporting insulators, bush trolley auxiliary contact, male female contact and check all wiring including minor item required for repair complete all as specified and directed. Note:-1.This item quoted rate not include testing and adjusting the following relay including checking and rectifying the tripping circuit complete.
M & L for testing and adjusting the following relay including checking and rectifying the tripping circuit complete, Calibration of relay for 11 KV VCB incoming/ Outgoing panel. (a)Trip circuit suervision Relay, Make - AREVA – 01 No (b) Master Trip Relay, 24 DC Make - AREVA - 01 No (c) Instantaneous earth fault relay, Make-L&T – 01 No (d) Intelligent Panel Meter, Make-L&T – 01 No (e) Ammeter & Voltmeter Note: - (I) The tripping system of relays are to be calibrated with 33Kv receiving station EBS Hisar and test result in this effect to be submitted to Engr-in- Charge (II) The tripping timing of the relay to be adjusted less than 33KV system at EBS Hisar (III) The testing instrument whatever required to test the relays will be arranged by the contractor at his own cost (IV) The test shall be provided from authorized agency.
Supply only in replacement of Shunt trip coil 220 /110/24 volts DC
Supply only in replacement of Closing coil 220/110/24 volts DC
Supply only in replacement of Spring charging motor for HT breaker Make:-ABB/CG/Siemns
Supply only in replacement of On Off Indicator (Display) V6061 suitable for HT breaker Make:-ABB/CG/Siemns
Supply only in replacement of Aux switch suitable for HT breaker Make:-ABB/CG/Siemns
Supply and fixing in replacement of indicator lamp 220/110/24 V DC lamp type with holder base in different colours as directed
Isolating 11 KV HT over head supply from the substation, 2pole /4 pole structure and earth the complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips, removing transformer and taking out from plinth , 2pole /4 pole structure and shifting to another plinth and re-connect to LT and HT side and earth connection including installing , commissioning & testing of capacity 200 kva
Isolating 11 KV HT over head supply from the substation, 2pole /4 pole structure and earth the complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips, removing transformer and taking out from substation , 2pole /4 pole structure and transporting to authorized service centre/ work shop for repair and back to the installation after repair including installing , commissioning & testing of the capacity Upto 63 KVA
Isolating 11 KV HT over head supply from the substation, 2pole /4 pole structure and earth the complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips, removing transformer and taking out from substation , 2pole /4 pole structure and transporting to authorized service centre/ work shop for repair and back to the installation after repair including installing , commissioning & testing of the capacity Upto 100 KVA to 200 KVA
Draining out the complete transformer oil and keeping in safe custody in clean and dry containers for reuse. Opening the top cover of the transformer ,disconnecting and taking out complete core assy and dismantling it for checking the serviceability of the coil winding, checking the condition of the body, cleaning the tank and remove sludge/dirt, cleaning the coils limbs, re-fixing of core, core assy , tap changer assembly ,HT/LT Rewinding and connection , terminal studs of HT/LT sides and reassembling of transformer after repairs, refitting the transformer coil including improvement of Insulation Resistance value within desired level by heating or any other method to required level complete all as directed to the entire satisfaction of Engr-in-Charge:- (a) Upto 63 KVA NOTE:- The above quoted rates include labour charges for replacing Spares/ parts as required which shall be measured and paid separately as supply only in relevant items .
Draining out the complete transformer oil and keeping in safe custody in clean and dry containers for reuse. Opening the top cover of the transformer ,disconnecting and taking out complete core assy and dismantling it for checking the serviceability of the coil winding, checking the condition of the body, cleaning the tank and remove sludge/dirt, cleaning the coils limbs, re-fixing of core, core assy , tap changer assembly ,HT/LT Rewinding and connection , terminal studs of HT/LT sides and reassembling of transformer after repairs, refitting the transformer coil including improvement of Insulation Resistance value within desired level by heating or any other method to required level complete all as directed to the entire satisfaction of Engr-in-Charge:- (b) 100 KVA to 200 KVA NOTE:- The above quoted rates include labour charges for replacing Spares/ parts as required which shall be measured and paid separately as supply only in relevant items .
Material only for primary (HV side) double paper cover aluminium winded coils of existing type size and gauge and in weight complete with including11000 volt grade insulating material for transformer of 50 KVA to 160 KVA
All as per item 77 here-in- before but LV size 415 voltage graded.
Material only for (HV side) copper winded coil of existing type size and gauge 11000 voltage complete with insulating material for transformers 50 KVA to 160 KVA .
All as per item 90 here-in- before but LV side, 415 voltage rade. Note for 75-78: Actual weight of the each coil shall be measured and paid in the relevant items (ii) Labour Charges for rewinding of coil and fitting of formed coil included in the quoted rate)
Supply and fixing in replacement of new off load tap changer assembly complete, making connection and testing complete of the transformer of 50 KVA to 200 KVA capacity complete all as specified and directed.
Supply and fixing in replacement of cork sheet gasket of 06 mm thick for transformer tank complete all as specified and directed.
Supply and fixing in replacement , HV bushing (11000 voltage graded) with heat resistance gasket suitable for following capacity of outdoor/ indoor type transformer:- (a) Up to 63 KVA
Supply and fixing in replacement , HV bushing (11000 voltage graded) with heat resistance gasket suitable for following capacity of outdoor/ indoor type transformer:- (b) 100 KVA to 200 KVA
Supply and fixing in replacement of copper terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV size 11000 volts grade for following capacity of outdoor / indoor type transformer. (a) Up to 63 KVA
Supply and fixing in replacement of copper terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV size 11000 volts grade for following capacity of outdoor / indoor type transformer. (b) 100 KVA to 200 KVA
Supply and fixing in replacement of LV bushing (415 voltage grade) with heat resistance gasket suitable for following cap of outdoor/indoor type transformer:- (a) up to 63 KVA
Supply and fixing in replacement of LV bushing (415 voltage grade) with heat resistance gasket suitable for following cap of outdoor/indoor type transformer:- (b) 100 KVA to 200 KVA
Supply and fixing in replacement of copper terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV size 415 volts grade for following capacity of outdoor / indoor type transformer. (a) up to 63 KVA
Supply and fixing in replacement of copper terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV size 415 volts grade for following capacity of outdoor / indoor type transformer. (b) 100 KVA to 200 KVA
Material and labour for replacement of breather assembly filled with silica gel complete for transformer of capacity up to 200 KVA.
Supply & pouring of fresh transformer oil in transformers for topping up the level or replacement complete all as directed by Engineer-in-Charge. (Transformer oil shall confirm to relevant IS -335 and dielectric strength of 45 KV and getting it tested before and after filling complete all as directed and specified.
Material & labour for cleaning sprinkled transformer oil and all other foreign materials from external surface of transformer of capacity up to 63 KVA and preparing the surface to receive paint, and applying one coat of synthetic enamel paint, including writing SM No/MES No with paint on black base complete all as directed and specified.
All as per item 104 here-in- before but for 100 KVA to 200 KVA.
M & L for Opening / disconnecting the electrical connection of defective / burnt out LT/HT cable of any size 3 to 4 core from Transformer, LT Panel, DBs and any other connection, cutting the defective portion of cable, providing required size of thimbles/connectors at cable end and reconnecting the cable in previous location all as specified and directed by Engr-in-Charge.
Material & labour for dehydration and filtration of transformer oil of existing transformer of cap up to 200 KVA , 11/0.433 KV to obtain dielectric strength more than 40 KV at 2.5 mm gap including, testing complete all as specified and directed.. Note - Contractor has to bring Centrifusing machine at site for dehydration.
All as per item 91 here-in- before but for 1 MVA, 33/11 KV Transformer.
Supply and fixing in replacement oil temp gauge 0-120 degree Celsius with inbuilt sensor to be fitted on transformer and dismantling of existing unserviceable gauge of any capacity.
Supply and fixing in replacement silica gel Crystals complete all as specified and directed.
Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape,overall PVC sheathed 6 sqmm 2 core nominal cross section complete all as specified and directed
All as per item 95 here-in- before but size of 10 sqmm 2 core
Material and labour for replacement of breather assembly filled with silica gel complete for transformer of capacity of 1 MVA.
Isolating 11 KV HT over head supply from the distribution transformer mounted on platform/ 2 or 4 pole structure and earth the complete system properly, disconnecting all complete electric connection of the transformer from both HT/LT side including earthing strips, opening of transformer head and replacing cork sheet/gasket for stopping oil leakage from bushing/body including refixing all the accessories and making good to the entire satisfaction of EIC complete all as specified and directed.Note The rate of hydra crane are included in the quoted rate.
Shifting of trolly mounted transformer from sub stn to required location & connecting the LT and HT connection and all earthing connection and testing to restoring the supply during the period of repair of existing transformer in workshop and disconnecting and reshifting the transformer in the sub stn after the repaired transformer shifted in the existing location complete all specified and directed. Note The rate of hydra crane are included in the quoted rate.
Suplying and laying of gravels of size 25 mm to 40 mm for all electrical sub station, transformer and panel plateform and making even surface complete all as specified and directed.
Supply, fabricating, installation, testing , commissioning and electrically connecting in replacement of LT panel of size 100 x 80 x 50 cm, 415 volts factory made dust and vermin proof for out door type made out of CRCA sheet 3.15 mm thick powder coated machine pressed both side opening in two halves with rubber beading including aluminium bus bar of 200 amps capacity 4 strip mounted on porcelain insulator. Bus bar chamber shall be provided with inspection covers , each ACB/MCCB /cubical switch shall have be independent opening. Panel shall be mounted on angle iron frame and legs made from angle of size 40x40x5mm frame including lifting arrangement and legs, duly spray painted internally and externally with two coats of synthetic enamel paint after a coat of red oxide primer grouted in PCC 1:3:6 type B:2 ( 40 mm graded stone aggregate ) foundation with required earth work complete including all connections for incoming / outgoing ACB/MCCBs, cable gland suitable for incoming/outgoing cable and control wiring with suitable size of copper conductor cable comprising of following accessories including testing complete all as specified and directed by Engineer-in-charge. (i) MCCB 125 Amps, 25 KA, 4 Pole, Ics = 100% Icu with adjustable thermal and fixed magnetic release (Incoming) =01 No (ii) --do-- but MCCB 63 Amp, 25 KA,4 Pole, Ics = 100% Icu (outgoing) =02 No . (iii) Indicator lamp RYB = 01 set.
Supply, installing, testing and commissioning in replacement of automatic power factor control panel board outdoor type suitable for 50 (20+20+10) KVAR metal clad double door type made out of 3.15 mm mild steel CRCA plain sheet and support for fixing switch for LT 3 phase 4 wire, 415 volts 50 c/s with proper front and back side opening door and locking arrangements duly powder coated as specified, mounted on PCC (1:2:4) type B1 using 20mm graded stone aggregate as in foundation as per manufacturer instructions complete all as specified includuing provision of following accessory/ components housed in it :- (a) 100 Amp rated copper bus bar with PVC slieve supported on insulators : 01 set (set of 04 bus bars) (b) Power factor control relay 5 step with intelligent control - 01 No. (c) MCCB 100 Amps 4 Pole 25 KA -01 No (d) ML contactor suitable for 20,20,10 KVAR capacitor with suitable size of MCB.
Material and labour for replacement of indicator lamp in differenet colour code LED/Neon type (as per sample) complete (RYB) including wiring with copper conductor cable of suitable size all as specified and as directed by Engineer-in-Charge.
Material & labour for cleaning, rubbing by amren paper and other foreign materials external surface of feeder pillar box/LT panels and preparing the surface for paint, spraying by gun one coat of synthetic enamel paint of existing colour of panel on Internal and External surface, including minor repairing of panels like door hinges with welding/nuts bolts etc complete all as specified and directed .
Repair to LT panel board body by replacing MS sheet of existing gauge size and shape for door shutter/body of feeder piller, including replacement of broken hinges and all as specified and as directed by Engineer in Charge.
Supply and fixing in replacement Aluminium bus bar of suitable Amp capacity in existing LT panel/feeder piller etc including provision of insulation tape RYB in colour and holes, nuts & bolts etc
Supply and fixing in replacement Copper bus bar of suitable Amp capacity in existing LT panel/feeder piller etc including provision of insulation tape RYB in colour and holes, nuts & bolts etc
Supply and fixing in replacement of LT cable junction box, dust and water proof made out of PVC non- metallic sheet FRP type, factory made, size of box 250x200x100mm deep with swiveling cover and locking clamp, consisting of aluminium bus bar strip 150mm x 30mm x 3mm, 4 Nos mounted on PVC insulator fixing the box along the pole with suitable size of clamps and nut bolts, provision of incoming/outgoing cables with grommets, including in built 6 Amp MCB, SP, 9/10KA one No complete all as specified and as directed by Engineer-in-charge.
Supply and fixing PVC pipe 20 mm on pole with suitable clamp, nut and bolt all as specified and directed
Supply and fixing aluminium service wire stranded PVC sheathed two core 1100 Volts of size 4 Sqmm for connection of street light fitting.
Supply and fixing in replacement energy efficient LED street light fitting of 45 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge
Supply and fixing in replacement energy efficient LED street light fitting of 60 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge
Supply & fixing driver suitable for 45 watt LED .
Supply & fixing driver suitable for 60 watt LED .
Supply and fixing surge protector device 10 kv
Supply and fixing in replacement energy efficient LED high mast light fitting of 120 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge
fauji electric works
M/s Devendera construction
MAHI PALL CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .