Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC MADURAI | TAMIL NADU | 625001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.7 L+₹3,324.47 (0.11%)Rejected-AOC 1035 A 2ND FLOOR J V STREET SUDHAKAR NAGAR VILUPPURAM | L2 | Rejected-AOC L2 |
Tender Value
₹30.0 L
EMD Value
₹30,000
Closing Date
5 Aug 2024, 4:00 pmClosed
BLOCK DEVELOPEMENT OFFICER(VP), KANAI
BLOCK DEVELOPEMENT OFFICE, KANAI
VPM/KANAI/JJM- NABARD RIDF-XXIX/03
2024_RDTN_468573_1
VPM/KANAI/JJM- NABARD RIDF-XXIX/03
Open Tender
Civil Works
Works
90 days
KANAI
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹30,000
1 Sept 2024
1 Aug 2024
5 Aug 2024
1 Aug 2024
5 Aug 2024
1 Aug 2024
Amount
CONSTRUCTION OF 60000 LITRES OHT AND PUMPING MAIN PIPE LINE 687M IN MAMBALAPATTU PANCHAYAT
Earth work excavation and depositing on bank with initial lead and lift in hard stiff clay and hard gravelly soil as per SS20B for narrow foundations .
a) First Depth 0.0 m - 2.0 m below GL
b) Second Depth from 2 . 0 m - 4 . 0 m below GL
Supplying and Filling in Basement with Filling M.Sand in layers not more than 15 cm thick , well ramed and consolidated complying with standard specification
Cement Concrete 1:4:8 Using 40mm ISS size Hand Broken granite stone jelly including labour charges for mixing concrete watering and laying the concrete in layers not more the 15 cm thick compacting etc complete complying with standard specification etc complete
Supplying and erecting shuttering including complying with standard speficiation including all labour charges etc.complete.
PLAIN SURFACE
Below Ground Level
From GL - 3.30 m Brace bottom
From 5.30 m to 6.30 m above GL
From 8.30m to 9.30m above GL
From 11.30 m to 12.30 m
CURVED SURFACE
0 to 3.30m from Floor Level
From 3.30 - 4.30 m
SQUARE COLUMN
Below Ground Level
Ground Level to 3.30m
From 3.31 to 4.30m
From 4.31 to 5.30m
From 5.31 to 6.30m
From 6.31 to 7.30m
From 7.31 to 8.30m
From 8.31 to 9.30m
From 9.31 to 10.30m
From 10.31 to 11.30m
From 11.31 to 11.45m
RCC in M30 GRADE using graded aggregtes of HBGs excluding cost of reinforcement, centering, shuttering strutting, but including cost of mixing concrete, placing, vibrating with mechanical vibrator, finishing, curing etc., complete as directed by Departmental officers
Below GL from 1.50 m - 4.50 m
Below 1.50m from GL
From 0 to 4.50m Above Ground Level
From 4.51 to 7.32 m Above Ground Level
From 7.32 to 10.98 m Above Ground Level
From 10.98 to 14.64 m Above Ground Level
From 14.64 m and upto 18.30 m from Ground Level
Supplying, Fabricatung and placin g in position of RTS or MS rod for all reinforced cement concrete works as per design given including cost of steel and binding wire in all floors etc,complete complying with standard specification
Painting Two Coats with approved Cement Paint over the Plastered surface over one coat of Whie Cement including cost of all materials and labour charges etc complete
Fabrication, supply, delivery and fixing of outside MS ladder of 45cm wide made out Fabrication, supply, delivery and fixing of outside MS ladder of 45cm wide made out of 50x50x6mm MS angle for sides and steps in 16mm MS plain rods fixed at 30cm
Providing and fixing of RCC inner access ladder in RCC 1:1.5:3 (one cement, one and half sane! and three aggregates) using 20mm HBG stone for OHT including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete
Providing PVC ventilating arrangements mosquito proof nylon net with 110 mm PVC pipes and cowl and as directed by Departmental officers
Providing cut stone slab in CM 1:3 and as directed by Departmental officers
Providing Man hole Cover of size 0.60m x0.60m in Rc c 1:1.5:3 with suitable Reinforcement and 50 x50x6mm MS angle fixed along edges and as directed by dept officer
Provision for pipe connection arrangements
65 mm GI Pipe Inlet
65 mm GI Pipe Over Flow
65 mm GI Pipe Deleivery
50 mm GI Pipe for Scour
90 mm PVC Thread Coupler
75 mm PVC Thread Coupler
63 mm PVC Thread Coupler
65 mm GI Tee
65 GI Ell
65 x 50 mm GI Reducer
75 mm X 63 mm PVC Reducer
65 mm GI Union
65 mm GI Flange
65 mm GI Coupling
65 mm Gate Valve
50 mm Gate Valve
Refilling the foundation with excavated earth including consolidation as directed by the Departmental officers.
Labour charges for GI Pipe connection to the OHT , for inlet, out let ,overflow pipe and scour arrangements including cutting and threading , earth work excavation & refilling
Providing Hand rails over the Roof slab by using 32 mm GI Pipe with 40mm x6mm MS Flate and fixied with 12mm dia fastner bolt 75mm long and as directed by dept officer
Providing Pumping main line and Distribution Pipe line
Earthwork Excavation and Depositing on bank with an initial lead of 10m and lift of 2 mts in all types of soil for pipe line works
Supplying and delivery of following Pipes and specials including transporting charges etc.
90mm OD PVC Pipes
63mm OD PVC Pipes
Laying and jointing the following PVC Pipes to trench with proper allignment with PVC Coupler & Cement Paste including conveying & testing with required preasure and leakage etc.
Refilling the Trench with excavated other than sand Labour charges only
Provision for New bore well and accessories
Provision for Name Board Charges
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
DEVAKI CONSTRUCTIONS (BID ID -1101401)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .