Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.8 L+₹2.3 L (23.8%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹13.0 L+₹3.4 L (36.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹13.9 L+₹4.3 L (45.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹15.3 L+₹5.8 L (60.8%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹40,600
Closing Date
1 Aug 2022, 6:00 pmClosed
GE (AF) BHISIANA
GE (AF) BHISIANA PIN-151201
AS PER BOQ/PRICE SCHEDULE
2022_MES_531188_1
GE/BHI/T-70/2022-23
Open Tender
Civil Works
Item Rate
273 days
GE (AF) BHISIANA
AS PER NIT/TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
GE (AF) BHISIANA
₹40,600
Yes
8 Sept 2022
15 Jun 2022
3 Aug 2022
15 Jun 2022
1 Aug 2022
2 Jul 2022
21 Jun 2022 - 28 Jun 2022
Amount
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable Pipes, Bricks, etc. and depositing to MES store yard for reuse complete all as specified and as directed. NOTE : Necessary Earth Work will be Measured and Paid under appropriate Items.
Supply & Laying/ Fixing of XLPE insulated, screened armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 25 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
Supply & Laying/ Fixing of XLPE insulated, screened armoured heavy duty Electric Cable with Aluminium Conductor Multi Stranded, 1100 Volt grade, Cross sectional area 16 Sqmm 4 Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated copper conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 2.5 sq. mm nominal cross section in service connections.
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
M&L Sand (Fazilka) Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply & Laying old bricks to provide brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10 mm complete all as specified and directed.
Material and labour for preparation of old painted steel pole surfaces and applying alternatively in yellow and black one coat of synthetic enamel black paint to steel tubular pole upto 1 mtr height from ground level and remaining with two coats aluminium paint to LT pole including numbering of pole with black paint complete as specified and directed by Engr-in-Charge.
Material and labour for preparation of old painted PCC pole surfaces and applying alternatively in yellow and black one coat of synthetic enamel black paint to PCC pole upto 1 mtr height from ground level to LT pole including numbering of pole with black paint complete as specified and directed by Engr-in-Charge.
Supply, installing, testing and commissioning factory made LT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200Amps including 1 No MCB SPN 06 Amps on suitable foundation of concrete surface, complete all as directed by Engineer in Charge.
Supply and fix Pole Mounted Junction Box having aluminium bus bar suitable for street light connections including single pole MCB of rating 6 Amps, 2.5 sqmm copper comductor for connection and fixing arrangement to pole all as specified and directed by Engineer-in charge
S&F Tubular swaged pole including taking down for steel tubular swaged poles with welded brackets type 410-SP-31 (09 mtr long) with mild steel base plate of size 30cmx30cmx6mm thick, welded at bottom including taper plugs, bolt, nuts and screw as directed and fixed in true vertical position complete all as directed by Engineer in Charge. Note :- (a) Earth work, shall be measured and paid separately under respective items. (b) Poles shall be painted with two coats of black bituminous paint throughout internally and externally up to foundation depth and Exterior surface shall be painted with two coats of aluminium paint over a coat of red oxide primer (c) Cement Concrete 1:3:6 Type C-1 (20mm graded stone aggregate)and necessary form work of required depth shall be measured and paid seperately under appropriate items.
M&L Galvanised Steel Tubing Pipe 15mm bore (dia), Medium grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Cement Concrete 1:3:6 Type C-2 (40mm graded stone aggregate) as in Foundation of Electric Poles/ Strut/ Stay, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork including dismantling existing concrete work, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 Type C-1 (20mm graded stone aggregate) as in Pole Pedestal, etc. including weathering slightly rounded or chamfered angle and throating, finishing all exposed faces of Concrete with necessary Formwork including dismantling existing concrete work, complete all as specified and as directed.
M&L for Galvanized steel tubing 50 mm dia light grade for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings etc including taking out existing complete all as specified and directed
Taking down unserviceable street light fitting upto 11 mtrs HPSV/fluorescent light fitting /CFL Fitting/LED Fitting /Flood light fitting of any size from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractor Note : All T&P ie ladder,Tools,Safty glooves etc shall be provided by the contractor without any extra cost
Supply and fixing 60 W LED based street light luminaries new generation energy saving & environment friendly light fitting high power LEDs as light sources.LED luminous efficiency should be > 80Lm/w.It should have active power factor correctio (APFC) electronic gear (electronic driver).Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission.It shall have epoxy powder coated grey finish phosphochromate treatment,IP-66 protection class I operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz.fitting should be suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5sqmm with OH line or PVC junction box, complete all as specified and directed by Engr-in-charge. Make : Havells LHRD01230674 /Philips Cat No GPLS 30 LED 60W/68W LEH2 240/50Hz NP/CG Cat No LSTO60 CDL
Supply and fixing 45 W LED based street light luminaries new generation energy saving & environment friendly light fitting high power LEDs as light sources.LED luminous efficiency should be > 80Lm/w.It should have active power factor correctio (APFC) electronic gear (electronic driver).Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission.It shall have epoxy powder coated grey finish phosphochromate treatment,IP-66 protection class I operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz.fitting should be suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5sqmm with OH line or PVC junction box complete all as specified and directed by Engr-in-charge. Make : Havells LHRD01230674 /Philips Cat No GPLS 30 LED 60W/68W LEH2 240/50Hz NP/ CG Cat No LSTO60 CDL
Supply and fixing 80 watt LED Flood light luminaire of epoxy powder cated CRCA MS housing with epoxy powder coated aluminium heat sink with system wattage .with 120 degree view angle,>100 lumen/watt,luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.The LED used in fitting is of make must be of make CREE/NICHIA/OSRAM/PHILIPS.
Supply and fixing 150 watt LED Flood light luminaire of epoxy powder cated CRCA MS housing with epoxy powder coated aluminium heat sink with system wattage .with 120 degree view angle,>100 lumen/watt,luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.The LED used in fitting is of make must be of CREE/NICHIA/OSRAM/PHILIPS.
Supply and fixing 200 watt LED Flood light luminaire of epoxy powder cated CRCA MS housing with epoxy powder coated aluminium heat sink with system wattage .with 120 degree view angle,>100 lumen/watt,luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.The LED used in fitting is of make must be of CREE/NICHIA/OSRAM/PHILIPS.
Supply and fixing LED active power factor correction (APFC) electronic gear (electronic driver) which uses 60 Nos.1W ( 60 W) high power LEDs as light sources all as directed by Engr-in-Charge.
Supply and fixing LED active power factor correction (APFC) electronic gear (electronic driver) using 45 W LED as light sources all as directed by Engr-in-Charge.
M&L for GI Pipe Bracket made out of Galvanised Iron Tubing 50mm bore (dia), light grade, 1.50 METRE long bent to shape with two Nos of MS Clamp duly painted nuts and bolts as per specified for fixing Street Light Fitting including taking down unserviceable GI Pipe Bracket, complete all as specified and as directed.
M&L for GI Pipe Bracket made out of Galvanised Iron Tubing 25mm bore (dia), light grade, 1.50 METRE long bent to shape with two Nos of MS Clamp duly painted nuts and bolts as per specified for fixing Street Light Fitting including taking down unserviceable GI Pipe Bracket, complete all as specified and as directed.
S&F MCB SPN 32 Amps 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, to be fixed on existing DB, complete all as directed by Engineer in Charge.
S&F MCB SP 6 to 32 Amps 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, to be fixed on existing DB, complete all as directed by Engineer in Charge.
Repair/mantenance of street light/security lights any type flood lights, Post Top lanterns or any other external light in its position fixed on pole/high mast/building structure or by taking down to round,if required,testing all the components /parts wiring etc. identifying and replacing the defective components wise choke (ballast) electronic driver,igniter,capactor, lamp,lamp holder,connector,connection wire/cables,MCB etc.including refixing the fixing to its original position (if) taken down including repair,aint of street light control timer & junction box all as directed by Engr-in-charge for the period of 11 months from the date of commencemnt of the work. Note : The rate against the above mentioned items is deemed for cost of labour, Tools & Plants and allied expenses only.
NOTE FOR SER ITEM No 32 (a) Cost of spare choke (ballast) electronic driver, igniter,capacitor, lamp,lamp holder connector replaces against above maintenance item will be measured and paid seperately under respective item of of schedule. (b) The contractor's representative will report to concerened JE E/M at 0900 hrs daily to collect the list of defective street light fitting and shall submit the completion report on the same day before 1730 hrs to JE E/M and submit the report to GE along with RAR. (c) The contractor has to rectify the defects/reports and make the street light servicable with in 24 hours from time the list of defective street lights is handed over to rep by the concerened JE E/M. In case the street light is not made functional for whatsever reason with in the specified time line,an amount of Rs. 100 per such defective street light per day will recovered from the amount due to him through RAR /Final Bill and submit the report to GE.The contractor shall be carry out repair/maint will simultaneously both domestic & tech area by engaging seperate team of electrician/technician in order to ensure proper & timely rectification of defects. (d) The contractor shall maintain sufficient stock of spares/materials required for repair/maint of street light with the concerened JE E/M. Note :Vehicle and T&Pwill be arrange by the contractor. (e)The contractor shall be fully responsible for the safety of their labours engaged for executing this work and they will provide all requisite safety equipments and clothing to his men and department shall not be responsible for any mishappening/accident/injury to their labours.
SWARN SINGH AND CO.
Aman Enterprises
REYANSH GARG AND COMPANY
KAY VEE CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .