| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.5 L+₹99,830 (5.72%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-AOC L2 | |
| 3 | L3₹20.4 L+₹3.0 L (16.9%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹21.5 L+₹4.1 L (23.3%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-AOC L4 | |
| 5 | L5₹22.2 L+₹4.7 L (26.9%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹50,280
Closing Date
7 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIR/REPLACEMENT OF LT NETWORK AND ALLIED WORKS AT AF STN YELAHANKA
2020_MES_380176_2
8828/E8
Open Tender
Civil Works
Item Rate
180 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹50,280
Yes
8 Mar 2021
23 Oct 2020
9 Nov 2020
23 Oct 2020
7 Nov 2020
24 Oct 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size250 mm x 150mm x 40mm all as specified and directed.
Supply, lay, spread in trenches river sand including spreading, levelling, punning for cushioning of cable.
Supply and laying in trenches, LT underground cable of size 4 core 10 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-cahrge.
Supply and laying in trenches, LT underground cable of size 4 core 16 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-cahrge.
Supply and laying in trenches, LT underground cable of size 4 core 25 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-cahrge.
Supply and laying in trenches, LT underground cable of size 3.5 core 35 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-cahrge.
Supply and laying in trenches, LT underground cable of size 3.5 core 95 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-cahrge.
Supply and laying in trenches, LT underground cable of size 3.5 core 70 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-cahrge.
Supply and laying in trenches, LT underground cable of size 3.5 core 120 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-cahrge.
Supply and laying in trenches, LT underground cable of size 3.5 core 185 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-cahrge.
Supply and laying in trenches, LT underground cable of size 3.5 core 240 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-cahrge. Note:- (1) For Sl No 6 to 10 ,necessary excavation, returning filling and removal of soil shall be measured and paid under respective items of the same schedule separately
Supply and fix 9.0 meter long Steel tubular swaged poles type 410 SP-31 complete with cast iron base plate, finial taper plug, bolts, nuts & screws all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation,filling and mass concrete complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate for stay and couping for poles including necessary form work to exposed surface finished smooth and even all of specified.
Supply and jointing staright through joint outdoor type 1100 volts grade heat shrinkable type suitable for 3.5x 35 sqmm to 3.5x 95 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed by Engr-in-charge
Supply and jointing staright through joint outdoor type 1100 volts grade heat shrinkable type suitable for 3.5x 120 sqmm to 3.5x 150 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed by Engr-in-charge
Supply, install and commmissionng of LT out door loop in loop out terminal box with sloping canopy of size 600x450x250mm made out of 3 mm thick CRCA sheet duly painted with two coars of syntehtic enamel paint over a coat of rex oxide, front and rear hinged doors mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 250 Amps 4 pole ,415 mps, 50 Hz of breaking capacity 35 KA as incomer and MCB TPN 63 Amps-02 Nos as out going including taking down old terminal boxes complete all as specified and directed.
Supply and fix bus bar box of size 0.45x0.3x.50 mtrs fabricated by 3 mm thick MS sheet outdoor type,mounted/fixed on angle Iron frame of MS equal angle size 40x40x6mm of height 0.90 mtr and fixed in ground complete box with dust/vermin proof including aluminium flat of size 50x 6 mm fixed as bus bar over the insulators,sleeved for three phase and neutral and spray painting the box with two coats of enamel paint over a coat of metal primer complete all as specified and directed by Engr-in-charge including necessary excavation,PCC for fixing the box all as directed.
Preparing old faded painted surfaces of 9 m long steel tubular pole complete including all accessories such as cross arms bracings, brackets etc and paints with two coats of Aluminium paint of approved tint including writing pole number with paint same as existing earlier.
Preparing of old faded paint surface and painting with paint to existing LT PCC/RCC/steel tubular poles of size 9m long upto the height of 1.2m from the bottom with approved white and Blue colour alternatively including numbering of poles same as existing earlier all as directed
Supply and laying GI tubing light grade 50mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable
Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including GI pipe of 50/80/100mm dia suitable for 0.4mpa working pressure.
Supply and fixing of terminal box made out of SMC with hinged door and locking arrangements of size 140x140x95mm product code no GSJB-1414 including ,Backlite 4 way connector,MS Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer ,electrical connections incl MCB SP 6-32 Amps complete all as specified and as directed. Make - Sintex or its techno commercial equivalent.
S&F pole mounted junction box (Street light box) sliding type doors fits to base by 3 phase busbar insulator - 04 Nos for street lighting system with nuts and bolts with fixing arrangment outdoor type of dismension 240 x 130 x 110 mm product code no GSJB-2817 for with suitable screen printed skull and bones for danger notice on middle and top cover of the box Make - sintex or its techno commercial equivalent.
Supply and fix cable route indicator made out of 3 mm thick ms sheet of size 20 cm x 15 cm duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, capacity, size with white paint, mounted on angle iron 40x40x3 mm, angle height 45 cm, (30cm below ground level) with PCC 20cmx20cmx15cm all as specified and as directed by Engineer- in- charge.
Supply and Fix MCB TPN 63 Amps, 10 KA rupturing capacity, C curve rupturing capacity. Make - Indo Asian Cat No. 811242 or its techno commercial equivalent.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 32x6 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I of 2009 connected to and including earthing test point or disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe for watering and funnel, GI Pipe medium grade 40mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1 all as specified and directed by Eng-in-charge.
Supply and fixing of MCCB 4 pole 250 Amps 415 volts of breaking capacity 35 KA adjustable thermal and magnetic based type all as specified
Supply and fix MCCB 4 pole 100 Amps,415Volts,50 Hz,AC with adjustable microprocessor released of breaking capacity 35 KA all as specified and as directed.
Supply and fix MCCB 400 Amps,4 pole 415 Volts,50 Hz,36 KA adjustable thermal and magnetic based type all as specified and directed.
Supply and fix aluminium lugs suitable for UG cable of size 35 to 95 sqmm all as specified and directed.
Supply and fix aluminium lugs suitable for UG cable of size 120 to 150 sqmm all as specified and directed.
Supply and fixing of PVC spacers for 4 wire LT 1100 Volts grade overhead line all as directed.
Maintenance for Solar control system with inserting a new postpaid sim cards(21 Nos) in the favour of GE(AF) Yelahanka and recharging of the same for the period of 6 Months as received by Airtel office complete all as specified.
Removing of old un used PCC/RCC poles from existing place and throw the same within 1 km radious all as directed by Engr-in Charge.
Cutting and taking out old unserviceable LT panel of any capacity, old unused cable from all the sub stations and surrounding area including checking the functioning of the exsting system all as specified and as directed. Note:- The old unserviceable items obtained from item no 35 shall be handed over to the MES store yard.
Cleaning of all the substations located at technical and domestic area once in a month as per Engr-in-charge's instructions by applying cloth for removing dirt on all the installations located inside the sub stations complete all as directed. Notes:- (i) Cleaning of side wall and roof, Cleaning of floor, Removing the dirt away from the sub station all as specified and as directed. (ii) The quoted rate shall include labour, cleaning materials and tools. (iii) The quoted rate shall also include the rate of materials like cottton, Broom, Mope, Stick for mountingBroom, Phenol which are required for the cleaning of installations
Supply only Fuse HP 10M15 15 Amps, 1000 VDC.
devan enterprises
MATA GUJRI CONSTRUCTION CO.
RRK PROJECTS
SREE VARU ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .