| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance PLOT NO 15 VASUDEV HARI NIVAS DATTATRAY NAGAR BADA BAZAAR TUMSAR TH TUMSAR DIST BHANDRA MAHARASHTRA 441912 | BHANDARA | MAHARASHTRA | 441912 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Non submitted documentation substantiating experience in similar type of works as mandated in the tender. The agency has provided evidence of experience limited to civil road construction projects only and dealership certificate from the OEM |
| 4 | Rejected-Technical | Rejected-Technical Omitted submission of documentation specifying the make and model of the air conditioning units proposed for installation. Additionally the agency has failed to provide essential documents as per stipulated under the general terms and conditions |
| 5 | Rejected-Technical 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | Rejected-Technical Not submitted the required specifications regarding the make and model of the air conditioning units |
Tender Value
Refer Docs
Closing Date
25 Apr 2025, 3:00 pmClosed
SO S and P
19A Gurusaday Road Kolkata 700019
Supply Installation Testing and Commissioning of 08 Nos Inverter type 4 TR Cassette Split type 03 Nos 2 TR and 02 Nos 1 pt 5 TR inverter split Air Conditioning units ar SRSC Bikaner Rajasthan
2025_NCSM_855232_1
BM-47(31)/PUR/2025(01) Supply Installation testing and Commissioning of AC
Open Tender
Electrical Goods/Equipment
Supply
20 days
Sub Regional Science Centre Bikaner
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
21 May 2025
1 Apr 2025
26 Apr 2025
1 Apr 2025
25 Apr 2025
2 Apr 2025
Electronics & Electrical Items :
Supply, Installation, Testing, and Commissioning of 3-star rating Hi wall split Inverter Air conditioning units consisting of one outdoor unit 2TR each of 230 volts, 50 Hz, Single Phase and one indoor unit 230 volts, 50 Hz, Single Rotary compressor, thermo sensor temperature control, timer setting, auto air swing, multifunction cordless remote, and using R-32 or R-410A eco-friendly refrigerant including( Installation kit) 3.0 meter copper pipe with insulation and 2.5 sq mm x4.0 core wire . (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier)
Supply, Installation, Testing, and Commissioning of 3-star rating Hi wall split Inverter Air conditioning units consisting of one outdoor unit 1.5TR each of 230 volts, 50 Hz, Single Phase and one indoor unit 230 volts, 50 Hz, Single Rotary compressor, thermo sensor temperature control, timer setting, auto air swing, multifunction cordless remote, and using R-32 or R-410A eco-friendly refrigerantincluding (installation kit )3.0 meter copper pipe with insulation and 2.5 sq mm x4.0 core wire . (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier)
Supply and fixing of floor/ wall mounting table stand suitable for holding the outdoor unit of 4 Tr. , made of 50mm x 50mm x 6mm MS angle as per the attached tentative drawing dimensions subject to actual dimensions of outdoor units, for the installation of the outdoor unit with anti-vibration pads on the roof of the building. This includes grouting on the wall/floor as required, depending on site conditions and as per instructions. Grouting shall be done by cutting necessary holes and securing with M12 anchor fasteners or cement concrete in a 1:2:4 mix. The damaged areas will be restored with a similar finish. Two coats of synthetic enamel paint will be applied over a coat of metal primer. Installation to be done as per direction of Engineering Incharge.
Supply and fixing of floor/wall mounting table stand suitable for holding the outdoor unit of 2.0 Tr. and 1.5 Tr, made of 35mm x 35mm x5mm MS angle bracket as per the attached tentative drawing dimensions subject to actual dimensions of outdoor units, for the installation of the outdoor unit with anti-vibration pads on the roof of the building. This includes grouting on the wall/floor as required, depending on site conditions and as per instructions. Grouting shall be done by cutting necessary holes and securing with M12 anchor fasteners or cement concrete in a 1:2:4 mix. The damaged areas will be restored with a similar finish. Two coats of synthetic enamel paint will be applied over a coat of metal primer.Installation to be done as per direction of Engineering Incharge.
Supply and fixing of copper piping with high-quality, high-density Nitrile Rubber foam insulation, covered with PVC Tape or Alumiinium Tape Covering to protect the insulation, all complete as per standard specifications and practices. The piping will be properly saddled (S.S Saddle) on the wall/terrace, including repairing any damage using cement mortar in a 1:2:4 mix on walls/floor to match the existing finish. Payment will be made based on actual execution. The copper piping sizes for the 4.0 TR cassette-type air conditioning unit are 9.52mm x 0.8mm (liquid line) and 15.88mm x 0.9mm (suction line). Copper line make: Totaline/Max Flow/Mandev.
Supply and fixing of copper piping with high-quality, high-density Nitrile Rubber foam insulation, covered with PVC Tape or Alumiinium Tape Covering to protect the insulation, all complete as per standard specifications and practices. The piping will be properly saddled (S.S Saddle) on the wall/terrace, including repairing any damage using cement mortar in a 1:2:4 mix on walls/floor to match the existing finish. Payment will be made based on actual execution. The copper piping sizes for the 2.0 TR & 1.5 TR Hi wall mounted split air conditioning unit are 6.4mm x 0.8mm (liquid line) and 15.88mm x 0.9mm (suction line). Copper line make: Totaline/Max Flow/Mandev.( Payment will be made as per actual execution)
Supply Installation, Testing & commisssioining of DOL starter 415 V, relay rating 16-25 A, with single phase prevente, Make: Seimens, L& T
Supply Installation Testing & Commissioning of Double door Distribution board of 4 Way SPN DB inclusive of DIN Rail , Earth Bar etc. make: siemens, L&T, Legrand etc.
Supply Installation & Termination of of 4 Pole Isolator of 40 Amp in existing SPN DB .
Supply and laying of 2.5 sq. mm, 4-core control cable, for connecting the indoor unit to the outdoor unit. Make: Plaza, Havells, RR Cables, Finolex, or any approved equivalent. Payment will be made based on actual execution. For (4 Tr., 2 Tr. and 1.5 Tr.)
Supply, installation, and testing of a 230V single phase motor starter 18A with a complete enclosure box, including all necessary connections (Relay setting: 11-18A). Make: Wipro, Havells, or equivalent
Supply and laying of 4.00 sq. mm, 4-core armoured PVC-insulated copper control cable from MCB DB to outdoor unit, along with double earthing using GI wire. Make: Plaza, Finolex, RR Cable, Havells, or any approved equivalent. The copper control cable will be properly saddled on the wall / terrace. Payment will be made based on actual execution.
Supply and fixing of ISI-marked extra PVC AC water drain pipe (15mm dia) wire breaded falexible for condensate water drainage with proper saddling . Make: National, Supreme, Prince, Astral, or equivalent. Payment will be made based on actual execution.
Supply and fixing of ISI-marked extra UPVC pipe (25mm/32mm dia) with 6.00mm thick closed-cell Nitrile rubber insulation, including elbows, tee sockets for condensate water drainage. Make: National, Supreme, Prince, Astral, or equivalent. Payment will be made based on actual execution.
Supplying and installing following size of perforated painted with powder coating (Black) M.S. Cable trays with perforation not more that 17.5% in convenient sections, joined with connectors suspended from the ceiling witj M.S. Suspenders including bolts & nuts painting suspenders etc as required. The connection pipeline, Copper pipe and cable wire between Indoor and Outdoor units along with water drain pipes must not rest on the false ceiling . They should be layed above the cable tray as above. (A) 100mm Width X 50mm DepthX1.6mm Thickness
COOLCREW AIRCON (BID ID -3201963)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .