REPAIR/ REPLACEMENT OF ACS, REFRIGERATOR, DEEP FREEZER, VOLTAGE STABILIZER CONNECTED E/M ALLIED SERVICES, MISC WORKS, FAN COIL UNITS (FCU) AND HEATING AND COOLING APPLIANCES ALONGWITH BOILERS, PIPE LINES UNDER AOR OF GE 864 EWS AT BB CANTT SRINAGAR
2024_MES_676622_1
864/WS-66/2024-25
Open Tender
Miscellaneous Works
Item Rate
GE 864 EWS
Class D and Category c(i)
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹90,000
Yes
12 Dec 2024
25 Sept 2024
4 Nov 2024
25 Sept 2024
29 Oct 2024
10 Oct 2024
Amount
M&L for cleaning and servicing of AC outdoor unit of Spilt type AC of rating capacity 1.5 Ton to 2.0 Ton 230 Volt any type/size any model/make by well qualified technician/mechanic including dismantling of body system and disconnecting of electric wiring /refrigerant gas pipe lines connections from fitted items in any position and removing all it connected electrical and electronic parts from inside/outside area of existing out door unit of AC system and also carry over work like washing, cleaning, servicing, and normal maintenance work of complete body system and cleaning with the help of high efficiency air pressure blower/vacuum pump along with water pressure jet pump with water system and also providing of cleaning solution materials for cleaning of condenser unit by wire mesh brush / nylon brush etc after cleaning/servicing work making oiling & greasing work for all moving parts of out door compartment and they after also re fixing & hanging the all removing parts on same to its original position including checking/tightening and replacement of minor defected item like of all type of nut, bolt, screws, gasket, electric wire and it connection etc and after making/ jointing of electric and refrigerant gas pipe lines connections and also making welding work if required for any broken/damaged part at site and after completion of job checking all type of leakage for water/electric/gas system and ensure that making it leakages proof and including testing it on load complete upto the satisfaction of Engr-in-Charge and all as specified & directed. Note:- The quoted rate shall be inclusive of T&P required at site to complete the Job. Nothing extra shall be admissible to the contractor on this ground.
Ditto all per serial item No. 1.00 described here-in-before but cleaning and servicing of wall mounted type based AC indoor unit suitable for using of Spilt type AC of rating capacity 1.5 Ton to 2.0 Ton any type/size, any model/make complete.
Ditto all per serial item No. 1.00 described here-in-before but cleaning and servicing of AC outdoor unit suitable for spilt type AC of rating capacity 2 Ton to 3.5 Ton 3 phase 415 Volt any type/size any model/make complete.
Ditto all per serial item No. 1.00 described here-in-before but cleaning and servicing of AC indoor unit used as in ceiling mounted cassette type & floor mounted tower condensing unit any type/size any model/make complete.
M&L for checking, testing of refrigerant gas leakage in refrigent gas pipe lines & AC outdoor & indoor unit system any type/size any model/make complete for Spilt type AC of rating capacity 1.5 Ton to 2 Ton 230 Volt by well qualified technician/ mechanic including dismantling of system item and disconnecting of electric wiring/ refrigerant gas pipe lines connections from fitted items in any position of system and also providing of N2 gas filling cylinder and after putting/ filling/ charging of nitrogen gas (N2 Gas) by pressure to entire body system of complete AC component after checking / detecting and arresting of the refrigerant gas leakage problem in system area and ensure that to carry over repairing/ jointing work for all leakage points with the help of welding/ brazing/ soldering by electrode rod and after make it gas /air/ water leak proof of complete system again after providing air vacuum pressure in system for holding gas to stand upto satisfaction level in system complete all as specified and directed Note- The quoted unit rate shall deemed to be included cost for charging/ filling and also required quantity of N2 gas for used numbers of times of nitrogen gas (N2 Gas) by pressure for testing to each AC entire system including T&P. Nothing extra admissible for many time testing in each AC system to contractor on this account.
Ditto all per serial item No. 5.00 described here-in-before but checking of refrigerant gas leakage in refrigent gas pipe lines & AC unit outdoor & indoor system any type/size any model/make complete unit of Spilt AC along with connected ceiling mounted cassette type/Tower based type condensing unit of AC complete of rating capacity 2 Ton to 3.5 Ton 3 phase 415 Volt complete.
S&F in replacement of single phase operating non invertor model AC type new one sealed rotary type AC compressor unit complete set all as per existing type of sample/ size & model/make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for window AC non invertor AC type hot & cold unit of rating capacity 1.5/2.0 Ton system and after making/ jointing of electric & refrigerant gas pipe lines connections complete all as specified & directed.
S&F in replacement of single phase operating non invertor model AC type new one sealed rotary type AC compressor unit complete set all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor AC type hot & cold unit of rating capacity 1.5 Ton system and after making/ jointing of electric & refrigerant gas pipe lines connections complete all as specified & directed.
Ditto all per serial item No. 8.00 described here-in-before but non invertor model AC type sealed rotary type AC compressor unit complete set and suitable using for split AC non invertor AC type hot & cold unit of rating capacity 2.0 Ton system complete
S&F in replacement of single phase operating invertor model DC type new one sealed rotary type DC compressor unit complete set all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC invertor DC type hot & cold unit of rating capacity 1.5 Ton system and after making/ jointing of electric & refrigerant gas pipe lines connections complete all as specified & directed.
Ditto all per serial item No. 10.00 described here-in-before but invertor model DC type sealed rotary type DC compressor unit complete set and suitable using for split AC invertor DC type hot & cold unit of rating capacity 2.0 Ton system complete .
S&F in replacement of three phase operating non invertor model AC type new one sealed rotary type AC compressor unit complete set all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor AC type hot & cold unit of rating capacity 2.0 Ton to 3.5 Ton 3 phase 415 volt system and after making/ jointing of electric & refrigerant gas pipe lines connections complete all as specified & directed.
S&F in replacement of split AC outdoor unit inside area, new one condensing coil unit along with existing type of tubes and fins complete set all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor/invertor model AC/DC type hot & cold unit of rating capacity 1.5 Ton to 2 Ton system and after making/jointing of electric/refrigerant gas pipe lines connections complete all as specified & directed.
S&F in replacement of split AC outdoor unit inside area, new one condenser electric fan motor single phase AC/DC type operating complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor/invertor model AC/DC type hot & cold unit of rating capacity 1.5 Ton to 2 Ton system and after making/ jointing of electric connections complete all as specified & directed.
S&F in replacement of split AC outdoor unit inside area, new one fan blade all as per existing type of sample/ size & model and suitable using for AC hot & cold type of rating capacity 1.5 Ton to 2.0 Ton system complete all as specified & directed.
S&F in replacement of split AC outdoor unit inside area, new reverse valve assembly with coil made out of cooper /brass complete set all as per existing type of sample/ size & model and suitable using for AC non invertor/invertor model AC/DC type hot & cold type of rating capacity 1.5 to 2.0 Ton system complete all as specified & directed.
S&F in replacement of new wiring kit set complete all as per existing type of sample/size & model and suitable using for electric connection purposed for indoor/outdoor unit in side area of AC non invertor/invertor model AC/DC type hot & cold type AC of rating capacity 1.5 Ton to 2.0 Ton system and making electric connection complete all as specified & directed.
S&F in replacement of single phase operating non invertor model AC type Split AC indoor unit inside area, AC operated new one PCB card (Printed circuit board) complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor AC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton system and making electric connection complete all as specified & directed.
S&F in replacement of single phase operating invertor model DC type Split AC indoor unit inside area, DC operated new one PCB card (Printed circuit board) complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC invertor DC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton system and making electric connection complete all as specified & directed.
S&F in replacement of single phase operating invertor model DC type Split AC outdoor unit inside area, DC operated new one PCB card (Printed circuit board) complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC invertor DC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton system and making electric connection complete all as specified & directed.
S&F in replacement of non invertor model AC type Split AC hot and cold type of rating capacity 2.0 Ton to 3.5 Ton system indoor unit inside area, ceiling mounted cassette type/floor mounted Tower/wall mounted type condensing unit fitted AC operated new one PCB card (Printed circuit board) complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item complete system and making electric connection complete all as specified & directed.
S&F in replacement of non invertor model AC type Split AC outdoor unit inside area fitted AC operated new one PCB card (Printed circuit board) complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor AC type hot & cold unit of rating capacity 2.0 Ton to 3.5 Ton 3 phase 415 volt system and making electric connection complete all as specified & directed.
S&F in replacement of non invertor/invertor model AC/DC type Split AC indoor unit inside area fitted new one single line/double line type multi mode operating AC/DC type display control card panel unit complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor/invertor AC/DC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton system and making electric connection complete all as specified & directed.
S&F in replacement of non invertor model AC type Split AC hot and cold type of rating capacity 2.0 Ton to 3.5 Ton system indoor unit inside area, ceiling mounted cassette type/floor mounted Tower/wall mounted type condensing unit fitted AC operated new one line/double line type multi mode operating AC display control card panel unit complete set all as per existing type of sample/ size & model & make make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item complete system and making electric connection complete all as specified & directed.
S&F in replacement of split AC new suction/discharge charging line valve for low/high pressure purposed complete set all as per existing type of sample/ size & model and suitable using for refrigent gas pipe line connection system for non invertor/invertor model AC/DC type AC unit hot & cold type of rating capacity 1.5 Ton to 2.0Ton system and including making gas pipe line connection complete all as specified & directed.
S&F in replacement of split AC indoor unit inside area fitted, new PVC filter complete all as per existing type of sample/size & model and suitable using for split AC hot & cold type of rating capacity 1.5 Ton to 2.0 Ton system complete all as specified & directed.
S&F in replacement of AC new capillary tube complete all as per existing type of sample/ size & model and suitable using for split AC hot & cold type of rating capacity 1.5 Ton to 2.0 Ton system and including making gas pipe line connection complete all as specified & directed.
S&F in replacement of split AC outdoor unit area outer side new outer cover body cabinet frame with it connected outer fixing accessories complete set made out of MS sheet all as per existing type of sample/size & model and properly match to all outer size details as per the existing replacement item and suitable using for non invertor/invertor outer body unit system of split AC hot & cold type of rating capacity 1.5 Ton to 2.0 Ton system and including make jointing work complete all as specified & directed.
S&F in replacement of split AC indoor unit attachment new PVC drain pipe of size 15 mm dia bore 3 meter long complete all as per existing type of sample/size complete all as specified & directed.
S&F in replacement of split AC indoor unit attachment new PVC drain pipe of size 15 mm dia bore 1.5 meter long complete all as per existing type of sample/size complete all as specified & directed.
S&F in replacement of new running capacitor of rating capacity 45 MFD to 60 MFD of 4/6/12 pin type complete all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item, properly match to each other as per the existing replacement item and suitable using for AC non invertor/ invertor model AC/DC type hot & cold unit system of rating capacity 1.5 Ton to 2 Ton and making electric connection complete all as specified & directed.
S&F in replacement of non invertor/invertor model AC/DC type split AC indoor unit inside area, new one evaporator coil unit with existing type of tubes, fins & blower etc complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor / invertor AC/DC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton system and making/ jointing of electrical and pipe line connection complete all as specified & directed.
S&F in replacement of non invertor/invertor model AC/DC type split AC indoor unit out side area new one outer body cabinet frame cover with base & top along with front louver flap grill & fins and it outer fixing connected fixing accessories complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor / invertor AC/DC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton system and making/ jointing of electrical connection complete all as specified & directed.
S&F in replacement of non invertor/invertor model AC/DC type split AC indoor unit new one electric blower fan motor with SS shaft unit single phase operating complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor / invertor AC/DC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton system and making of electrical connection complete all as specified & directed.
S&F in replacement of non invertor/invertor model AC/DC type split AC indoor unit electric new swing motor unit single phase operating complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor / invertor AC/DC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton system and making of electrical connection complete all as specified & directed.
S&F in replacement of non invertor/invertor model AC/DC type split AC new reversible valve coil single phase operating complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor / invertor AC/DC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton system and making of electrical connection complete all as specified & directed.
S&F in replacement of non invertor/invertor model AC/DC type split AC new starting relay coil single phase operating complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor / invertor AC/DC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton system and making of electrical connection complete all as specified & directed.
S&F in replacement of split AC indoor unit inside area new axial PVC blower with bush complete set all as per existing type of sample/ size & model & make and suitable using split AC hot and cold type of rating capacity 1.5 Ton to 2.0 Ton system complete all as specified & directed.
S&F in replacement of AC new heating and cooling sensor with lead complete all as per existing type of sample/ size & model & make suitable using for AC hot and cold type of rating capacity 1.5 Ton to 2.0 Ton system and making of electrical connection complete all as specified & directed.
S&F in replacement of new multi core round type PVC insulated and PVC round sheathed, flexible multi stranded copper conductor cable heavy duty 1100 volt grade of nominal area of cable conductor of size 4 Sqmm 3/4 core and also making electrical connection complete all as specified & directed.
S&F in replacement of new multi core round type PVC insulated and PVC round sheathed, flexible multi stranded copper conductor cable heavy duty 1100 volt grade of nominal area of cable conductor of size 2.5 Sqmm 3/4 core and also making electrical connection complete all as specified & directed.
S&F in replacement of AC indoor unit wall mounting type new MS bracket hanging stand frame base with nut and bolt and suitable for fixing of split AC indoor unit complete set all as per existing type of sample/ size and model complete all as specified & directed.
S&F in replacement of AC outdoor unit wall mounting type new MS bracket hanging stand frame base along with fastners,nut and bolt and suitable for fixing of split AC out door unit complete set all as per existing type of sample/ size and model complete all as specified & directed.
S&F in replacement of single phase operating three star rating invertor model DC type split AC hot and cold type outdoor unit of rated capacity 1.5 Ton complete set along with consisting it all attachment compartment of complete unit system and making/ jointing of electric and gas pipe line connection complete all as specified & directed. Note : Old outdoor unit shall be deposite to AGE E/M store.
S&F in replacement of new multi core round type PVC insulated and PVC round sheathed, flexible multi stranded copper conductor cable heavy duty 1100 volt grade of nominal area of cable conductor of size 1.5 Sqmm 3 core and also making electrical connection complete all as specified & directed.
Supply, fixing & jointing in replacement of heavy duty new copper tubing in different any size/type all as per existing sample/model complete suitable using for refrigerant gas pipe line system etc and properly match/jointing to each other as per the existing refrigerant gas pipe line system complete all as specified & directed.
Supply, filling in replacement of all type fresh new refrigent gas like- R-22 / R-32 / R-410 / R-134 / R-600 / R-290 etc for different system of AC & Ref eqpt. The all type of refrigent gas qty is required in each sealed packed based Tin bottle of each Tin bottle having storage capacity upto level 1.0 kg and suitable for using of gas as per the existing type refrigent gas or all as per the demand and site requirement basis complete all as specified and directed.
Supply & jointing in replacement of new butane in cartridge (fire Tin bottle) etc required qty in sealed packed based Tin bottle of each Tin bottle having storage capacity upto level 1.0 kg bottle and suitable using for welding/brazing work purposed in refrigerant gas pipe line system complete all as specified and directed.
Supply, fixing & jointing of new brazing rod and suitable using for welding/ brazing/ soldering work in refrigerant gas pipe line system complete all as specified and directed.
S&F in replacement of new hand operated split AC remote control unit complete all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for split AC non invertor/ invertor type AC hot /cold unit of rating capacity 1.5 Ton to 2.0 Ton complete all as specified and directed.
S&F in replacement of new dry battery AA/AAA pencil type suitable used for remote control unit purposed all as per existing type of sample/ size complete all as specified and directed.
S&F in replacement of new sheet metal enclosure duly powder coated enclosure with having single pole and neural based two pin phase and one pin earth along with providing top plug and including having mounting channel and complete with one 01 MCB SP 20 Amp and making all necessary electrical connection and dully fixed on surface complete all as specified and directed.
S&F in replacement of new flat type over all PVC sheathed insulated twin core type cable of size 10 sqmm 1100 Volt grade with having PVC outer weather proof insulated and inner PVC sheathed with aluminium multistranded conductor cable including making all necessary electrical connection complete all as specified and directed.
S&F in replacement in any position of new one nitrile insulation /aroma flex insulation material or round tube shape type runner sponge form or all as per existing type and size/ sample/ model and suitable use for upon the refrigent pipe line system & its connected fixture etc and duly covered it with the layer of insulation tap and to be properly match /finishing with as per the existing system complete all as specified and directed.
S&F in replacement of new single pole MCB SP 20 Amp, 10 kA, 'C' Series and making all necessary electrical connection complete all as specified and directed.
S&F in replacement of metal plug top with base socket with having three pin male & female adaptor system and making all necessary electrical connection complete all as specified and directed.
S&F in replacement of single phase operating invertor /non invertor model DC/AC type new sealed rotary compressor unit of A/A1 type or G1 type complete set all as per existing type of refrigerant gas system/ existing sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for Refrigerator single door system of storage capacity 190 Ltr system and after making/ jointing of electric & refrigerant gas pipe lines connections complete all as specified and directed.
S&F in replacement of single phase operating invertor/non invertor model DC/AC type new sealed rotary compressor unit of B/A2 type or G2 type complete set all as per existing type of refrigerant gas system/existing sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for Refrigerator single/double door system of storage capacity 200 to 290 Ltr system and after making/ jointing of electric & refrigerant gas pipe lines connections complete all as specified and directed.
S&F in replacement of single phase operating invertor/non invertor model DC/AC type new sealed rotary compressor unit of C/A3 type or G3/G4 type complete set all as per existing type of refrigerant gas system/existing sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for Refrigerator single/double door system of storage capacity 300 to 460 Ltr system and after making/ jointing of electric & refrigerant gas pipe lines connections complete all as specified and directed.
S&F in replacement of single phase operating invertor/non invertor model AC/DC type new sealed rotary compressor unit of KCN 411/ KCN415/ KCN416/ G4 etc type complete set all as per existing type of refrigerant gas system/sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for Deep freezer single/ double door type of storage capacity 300 Ltr to 500 Ltr system and after making/ jointing of electric & refrigerant gas pipe lines connections complete all as specified and directed.
S&F in replacement of single phase operating invertor/non invertor model DC/AC type new sealed rotary compressor unit complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for hot and hold type water dispenser unit of storage capacity 2.5 Ltr to 5 Ltr system and after making/ jointing of electric & refrigerant gas pipe lines connections complete all as specified and directed.
S&F in replacement of single phase operating invertor model DC type refrigerator new one DC operated PCB card (Printed circuit board) unit complete set all as per existing type of sample/ size & model & make and completely it to be properly match the all details rating capacity & technical specification to the each other as per the existing replacement item and suitable using for Refrigerator single/double door type of storage capacity 200 Ltr to 320 Ltr system and making electric connection including complete all as specified and directed.
S&F in replacement of single phase operating invertor model DC type refrigerator new one DC operated PCB card (Printed circuit board) unit complete set all as per existing type of sample/ size & model & make and completely it to be properly match the all details rating capacity & technical specification to the each other as per the existing replacement item and suitable using for Refrigerator single/double door type of storage capacity 380 Ltr to 460 Ltr system and making electric connection complete all as specified and directed.
S&F in replacement of single phase operating Refrigerator new freezer compartment complete set all as per existing type of sample/ size & model & make and completely it to be properly match the all details rating capacity & technical specification to the each other as per the existing replacement item and suitable using for Refrigerator single/double door type of storage capacity 190 Ltr to 290 Ltr system and after making/ jointing of refrigerant gas pipe lines connections complete all as specified and directed.
S&F in replacement of single phase operating Refrigerator new freezer compartment complete set all as per existing type of sample/ size & model & make and completely it to be properly match the all details rating capacity & technical specification to the each other as per the existing replacement item and suitable using for Refrigerator single/double door type of storage capacity 300 Ltr to 460 Ltr system and after making/ jointing of refrigerant gas pipe lines connections complete all as specified and directed.
S&F in replacement of single phase operating three star rated invertor model DC type split AC hot and cold type indoor unit of rated capacity 1.5 Ton complete set along with consisting it all attachment compartment of complete unit system and after making/ jointing of refrigerant gas pipe lines connections complete all as specified and directed. Note : Old indoor unit shall be deposite to AGE E/M store.
S&F in replacement of single phase operating new one outer condenser coil tube jali shape type unit complete set all as per existing type of sample/ size & model & make and and completely it to be properly match the all details rating capacity & technical specification to the each other as per the existing replacement item and suitable using for Refrigerator/Deep freezer single/double door type of storage capacity 190 Ltr to 290 Ltr system and after making/ jointing of refrigerant gas pipe lines connections complete all as specified and directed.
S&F in replacement of single phase operating new one outer condenser coil tube jali shape type unit complete set all as per existing type of sample/ size & model & make and and completely it to be properly match the all details rating capacity & technical specification to the each other as per the existing replacement item and suitable using for Refrigerator/Deep freezer single/double door type of storage capacity 300 Ltr to 460 Ltr system and after making/ jointing of refrigerant gas pipe lines connections complete all as specified and directed.
S&F in replacement of single phase operating new thermostat complete all as per existing type of sample/ size & model & make and suitable using for Refrigerator/Deep freezer single/double door type of rating capacity 190 Ltr to 460 Ltr system and including making electric connection complete all as specified and directed.
S&F in replacement of single phase operating new over load protection relay complete set all as per existing type of sample/size & model & make and suitable using for Refrigerator/Deep freezer single/double door type of rating capacity 190 Ltr to 460 Ltr system and including making electric connection complete all as specified and directed.
S&F in replacement of single phase operating new capillary tube complete all as per existing type of sample/size & model & make and suitable using for Refrigerator/ Deep freezer single/double door type of rating capacity 190 Ltr to 460 Ltr system and including jointing gas pipe line connection complete all as specified and directed.
S&F in replacement of single phase operating invertor/non invertor based DC/AC type new water dispenser electric water geyser heater with hot water tank of storage capacity 1 to 1.5 ltr complete set all as per existing type of sample/ size & model & make and suitable using for water dispenser of rating capacity 2.5 Ltr to 5 Ltr system and including making electric connection complete all as specified and directed. Note : Old dispenser shall be deposite to AGE E/M store.
S&F in replacement of single phase operating invertor/non invertor based DC/AC type new drier filter complete all as per existing type of sample/ size & model & make and suitable using for Refrigerator and deep freezer of rating capacity 190 Ltr to 600 Ltr system and including jointing gas pipe line connection complete all as specified and directed.
S&F in replacement of new starting /running capacitor of rating capacity 3 MFD to 20 MFD complete all as per existing type of sample/ size & model & make and suitable using for AC/Refrigerator and deep freezer etc purposed including making electric connection complete all as specified and directed.
S&F in replacement of new defrost timer complete all as per existing type of sample/ size & model & make and suitable using for Refrigerator and deep freezer purposed including making electric connection complete all as specified and directed.
S&F in replacement of new heating /cooling cut off sensor with lead complete all as per existing type of sample/ size & model & make and suitable using for non invertor /invertor type AC/DC based AC/Refrigerator and deep freezer purposed including making electric connection complete all as specified and directed.
S&F in replacement of PVC ventilation new fan with motor complete all as per existing type of sample/size & model & make and suitable using for Refrigerator and deep freezer purposed including making electric connection complete all as specified and directed.
M&L for isolating the single phase type voltage stabilizer burnt out core winding of rating capacity 4KVA to 5KVA by disconnecting the all electrical connections and dismantling of burnt out main transformer coil and unserviceable winding wire and after carrying out new rewinding wire with the super enameled winding wire as per existing type & size of gauge including providing of proper all type of insulating material and varnishing complete work and after completion of work reassembling and re fixing back to its original position and making necessary electric connections and testing on load complete all as specified and directed.
M&L for isolating the single phase type voltage stabilizer burnt out core winding of rating capacity 2KVA to 3KVA by disconnecting the all electrical connections and dismantling of burnt out main transformer coil and unserviceable winding wire and after carrying out new rewinding wire with the super enameled winding wire as per existing type & size of gauge including providing of proper all type of insulating material and varnishing complete work and after completion of work reassembling and re fixing back to its original position and making necessary electric connections and testing on load complete all as specified and directed.
S&F in replacement of single phase operating air cooled type voltage stabilizer AC/DC operated New PCB card (Printed circuit board) complete set all as per existing type of sample/size & model & make and completely it to be properly match the all details rating capacity & technical specification to the each other as per the existing replacement item and suitable using for voltage stabilizer of rating capacity 4KVA to 5KVA complete and making eclectic connection complete all as specified and directed.
S&F in replacement of single phase operating air cooled type voltage stabilizer AC/DC operated New PCB card (Printed circuit board) complete set all as per existing type of sample/size & model & make and completely it to be properly match the all details rating capacity & technical specification to the each other as per the existing replacement item and suitable using for voltage stabilizer of rating capacity 2KVA to 3KVA system complete and making eclectic connection complete all as specified and directed.
S&F in replacement of single phase operating air cooled type Voltage stabilizer new Volt/Amp meter with indicator lamp and switch complete set all as per existing type of sample/ size & model & make and suitable using for voltage stabilizer of rating capacity 2KVA/ 5KVA system complete and making eclectic connection complete all as specified and directed.
S&F in replacement of single phase operating air cooled type new Voltage stabilizer socket or connector port complete set all as per existing type of sample/ size & model & make and suitable using for voltage stabilizer of rating capacity 2KVA/ 5KVA system complete and making eclectic connection complete all as specified and directed.
S&F in replacement of single phase operating air cooled type Voltage stabilizer new over load cut off relay complete set all as per existing type of sample/ size & model & make and suitable using for voltage stabilizer of rating capacity 2KVA/ 5KVA system complete and making eclectic connection complete all as specified and directed.
S&F in replacement of new wall mounting hanging based single phase naturally air cooled indoor type automatic digital operation type voltage stabilizer complete set along with consisting all it attachment compartment of complete unit system and suitable for operation on single phase AC supply and with having designed voltage for input & output voltage 90 Volt to 230 Volt with accuracy +- 2.5% and having low and high voltage cut low voltage cut off 90 (-) 5 volts high voltage cut off 230 V (+ 5 ) Volts along with start time delay system with time delay adjustable from 30 second to 1.5 minutes system complete set of rating capacity 5 KVA complete and making eclectic connection complete all as specified and directed. Note : Old stabilizer shall be deposite to AGE E/M store.
Ditto all per serial item No. 85.00 described here-in-before but automatic voltage stabilizer of rating capacity 4 KVA complete
Ditto all per serial item No. 85.00 described here-in-before but automatic voltage stabilizer of rating capacity 2 KVA complete
S&F in replacement of ceiling mounted cassette type square shape indoor type condensing unit new electric fan motor with bush unit single phase operating complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for indoor cassette type condensing unit and it duly inter link attachment with outdoor unit of split AC non invertor type hot & cold unit of rating capacity 2 Ton to 3.5 Ton 415 Volt system complete and making eclectic connection complete all as specified and directed.
S&F in replacement of non invertor/invertor model AC/DC type new PCB power supply transformer coil complete all as per existing type of sample/ size & model & make and suitable using for AC non invertor/invertor model AC/DC type hot & cold unit of rating capacity 1.5 Ton to 2.0 Ton complete and making eclectic connection complete all as specified and directed.
M&L for cleaning, servicing and testing & checking of gas leakage in all Ref system of mortuary chamber inside and outside complete unit area suitable for three body holding capacity any type/ size any model/ make by well qualified technician/ mechanic including dismantling of all system and disconnecting of electric wiring connection/ refrigerant gas pipe lines connections from fitted items in any position and removing all it connected electrical and mechanical fitting from inside/ outside area of existing unit system and also carry over work like washing, cleaning, servicing, leakage testing and normal maintenance work of complete system and cleaning with the help of high efficiency air pressure blower/ vacuum pump along with water pressure jet pump with water system and also providing of cleaning solution materials for cleaning of condenser unit by wire mesh brush nylon brush etc after cleaning /servicing work and after completion of complete job if any type of leakage found in system providing of N2 gas filling cylinder and after putting/ filling/ charging of nitrogen gas (N2 Gas) by pressure to entire body system of complete component after checking / detecting and arresting of the refrigerant gas leakage problem in complete system area and ensure that to carry over repairing/ jointing work for all leakage points with the help of welding/ brazing/ soldering by electrode rod and after make it gas /air/ water leak proof and after making oiling & greasing work for all moving parts of compartment and they after also re fixing the all removing parts on same to its position including checking/ tightening and replacement of minor defected item like of all type of nut, bolt, screws, gasket, electric wire and it connection etc and after making/ jointing of electric and refrigerant gas pipe lines connections and also making welding work if required for any broken/ damaged parts at site and after testing it on full load complete all as satisfaction pressure level and all as specified & directed. Note:- The quoted rate shall be inclusive of T&P required at site to complete the Job. Nothing extra shall be admissible to the contractor on this ground.
M&L for cleaning, servicing, descaling of plant by well qualified technician/ mechanic for oil fired based hot water generator type system for CHS/ Boiler plant used as a hot water/ hot air circulation purposed including cleaning only inside area of combustion chamber any type/ size any model/ make complete work for CHS/ Boiler plant of rated heating capacity 400000 KCal/ hrs system including dismantling of electrical/ water/ fuel line connection and removing burner assembly along with it connected mechanical parts fitted on body system of plant in any position and also removing of all type of nut, bolt and other connected parts from plant body system and opening of top cover plate by providing adequate lobour and T&P for removing and taking out cover frame of entry gate area of combustion chamber and after carried over work in side area of chamber like cleaning with de-carbonization of combustion chamber and connected parts complete and removing of deposit all type of carbon material, sludge, scale, dust particle etc with the help of scrubbing by hand rub wire mesh brush / nylon brush cum steel wire rod fitted brush through cleaning push and pull method etc after cleaning it washing by cleaning solution and ensuring that the inside area of chamber has been cleaned upto max clean range and after cleaning/ servicing work providing of flame proof moldable refractory castable cement with packing materials for making filling/ plastering work inside area of damage/ broken portion complete and after re fixing the all removing parts on same to its original position including checking / tightening and also replacement of minor defected item like of nut, bolt, screws, gasket, electric wire connection etc and jointing of electric/ fuel/ water pipe lines connections and also making welding work if required for any broken/ damaged part at site and after completion of complete job checking any type of leakage problem for water/ fuel in system and ensure that making it leakages proof complete all as satisfaction and all as specified & directed. Note:- The quoted rate shall be inclusive of T&P required at site to complete the Job. Nothing extra shall be admissible to the contractor on this ground.
Ditto all per serial item No. 91.00 described here-in-before but CHS/ Boiler plant of rated heating capacity 300000 KCal/hrs system.
Ditto all per serial item No. 91.00 described here-in-before but CHS/Boiler plant of rated heating capacity 200000 KCal/hrs system.
Ditto all per serial item No. 91.00 described here-in-before but CHS/Boiler plant of rated heating capacity from 100000 KCal/hrs to 110000 KCal/hrs system.
Ditto all per serial item No. 91.00 described here-in-before but CHS/Boiler plant of rated heating capacity above 70000 KCal/hrs to 90000 KCal/hrs system.
M&L for cleaning, servicing of plant by well qualified technician/ mechanic for oil fired stand based hot Air generator type heating plant system used as hot air circulation purposed including cleaning inside area of combustion chamber complete any type/size any model/make complete work for CHS plant of rated heating capacity from 22000 KCal/hrs to 70000KCal/hrs system including dismantling of electrical/ fuel line connection and removing burner assembly along with it connected mechanical parts fitted on body system of plant in any position and also opening of combustion chamber and after carried over work in side area of chamber like cleaning with de carbonization of combustion chamber and connected parts and removing of deposit all type of carbon material, sludge, scale, dust particle etc with the help of scrubbing by hand rub wire mesh brush / nylon brush etc after cleaning it washing by cleaning solution and ensuring that the inside area of chamber has been cleaned upto max clean range, and after cleaning/servicing work and after re fixing the all removing parts on same to its original position including checking / tightening and also replacement of minor defected item like of nut, bolt, screws, gasket, electric wire connection etc and jointing of electric/ fuel pipe lines connections and also making welding work if required for any broken/damaged part at site and after completion of complete job checking all type of leakage problem for air/fuel in system and ensure that making it leakages proof complete all as satisfaction and all as specified & directed. Note:- The quoted rate shall be inclusive of T&P required at site to complete the Job. Nothing extra shall be admissible to the contractor on this ground.
M&L for checking & removing of leakages / damage of existing boiler heating coils single / double type size made out of MS water tube based or compact inbuilt water heating compartment and duly fitted inside area of CHS/Boiler plant chamber system of oil fired based hot water generator type system of CHS/Boiler plant of rated heating capacity from 90000 KCal/hrs to 400000 KCal/hrs system including disconnecting of electric/water/fuel pipe line connection any type any position from each CHS/Boiler plant system any type/size any capacity & model /make after dismantling and opening of outer cover frame plate with all type of nut, bolt and other connected parts from body system including providing adequate lobour and all type of T&P for finding of leakage problem work in side of boiler heating coils system and thereafter rectification the same leakage problem work in heating coils with the help of cutting/welding/brazing/ soldering of hot/cold any type of in any position of complete work and make it water leak proof after also re fixing the all removed parts on same to its original position including checking/tightening and replacement of minor defected item like of any type of nut, bolt, screws, packing gasket, electric wire connection etc and after making/ jointing of electric/ fuel/water pipe lines connections and also making welding work if required for any broken/damaged part at site and after completion of complete job checking all type of leakage for water/fuel in plant system and ensure that making it leakages proof and including testing on load complete all as satisfaction and all as specified & directed. Note:- The quoted rate shall be inclusive of T&P required at site to complete the Job. Nothing extra shall be admissible to the contractor on this ground.
M&L for cleaning, descaling of existing boiler heating coils single / double type size made out of MS water tube based coil or compact inbuilt water heating compartment and duly fitted inside area of CHS/Boiler plant chamber system of oil fired based hot water generator type system for CHS/Boiler plant of rated heating capacity 400000 KCal/hrs system of any type/size any model complete work by well qualified technician/mechanic by dismantling of electrical/ fuel/ water along with connected mechanical parts fitted on body system in any position and also opening of inlet & outlet water pipe line connection of both side end of coil and after carried over work like descaling of inside area of boiler heating coil or compact inbuilt water heating compartment system with the help of full filling of chemical solution compound/ acid for descaling of coil/chamber before descaling of boiler heating coil /chamber to allow the descaling chemical solution material to hold for 2 hrs for chemical reaction. After the completion of chemical reaction of given duration hrs including providing of separate high speed pressure pump motor & making the arrangement of suitable size/type of piping flange with nipple along with suitable type/size of in/out let flexible pipe line along with water tank for the purpose of circulation the chemical solution for minimum 4 hrs duration and ensuring that the coil/chamber has been descaled upto max clean range and after descaling/servicing work also re fixing the all removed parts on same to its original position including checking/ tightening and replacement of minor defected item like of any type of nut, bolt, screws, gasket, electric wire and it connection etc and after making/ jointing of electric and water pipe lines connections and also making welding work if required for any broken/ damaged part at site and after completion of job circulating clean water in the tubes /chamber and draining out it complete and after checking all type of leakage for water/fuel in system and ensure that making it leakages proof complete all as satisfaction and all as specified & directed. Note:- The quoted rate shall be inclusive of T&P required at site to complete the Job. Nothing extra shall be admissible to the contractor on this ground.
Ditto all per serial item No. 98.00 described here-in-before but CHS/Boiler plant of rated heating capacity 300000 KCal/hrs system.
Ditto all per serial item No. 98.00 described here-in-before but CHS/Boiler plant of rated heating capacity 200000 KCal/hrs system.
Ditto all per serial item No. 98.00 described here-in-before but CHS/Boiler plant of rated heating capacity from 100000 KCal/hrs to 110000 KCal/hrs system.
Ditto all per serial item No. 98.00 described here-in-before but CHS/Boiler plant of rated heating capacity from 70000 KCal/hrs to 90000 KCal/hrs system.
M&L for cleaning, descaling of water make up tank /storage water tank / fuel tank / hot/ cold water tank any type/ size any model suitable used for oil fired based hot water/ Air generator type CHS /Boiler plant system including cleaning inside area of tank complete by cleaning solution & scrubbing with the help of wire mesh brush / nylon brush with cloth and removing of deposit all type of sludge, scale, dust particle materials etc and after washing of tank with clear water and ensuring that the inside area of tank has been cleaned complete all as satisfaction and all as specified & directed.
S&F in replacement of ignition transformer unit with wire adaptor and having single phase rated voltage of capacity 14500V large shape based type complete all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS/ Boiler/ Incinerator plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of ignition transformer unit with jack adaptor and having single phase large and small shape based type complete all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS/ Boiler/ Incinerator plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of high temperature ignition cable / ignition rod / HT cable with adaptor complete all as per existing type of sample/ size/ length & model & make and suitable using for CHS/ Boiler/ Incinerator plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of electrode set front/ rear pair based type complete all as per existing type of sample/ size/ type & model and suitable using for CHS/ Boiler/ Incinerator plant system and including making/ jointing of connection complete all as specified & directed.
S&F in replacement of photo cell with lead long shape type single phase complete all as per existing type of sample/ size & model & make and suitable using for burner assembly of CHS plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of photo cell with adaptor holder & lead long shape type single phase as per model / type - 8205 complete all as per existing type of sample/ size & model & make and suitable using for Steam boiler plant/ Incinerator plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of sequence controller unit complete and reqd as per the existing site requirement all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS/steam boiler plant/Incinerator plant system and including making electrical connection and taking down of old U/S existing item complete.
S&F in replacement of burner primary controller box compact unit as per model/type of RBL 530SE complete set and reqd as per the existing site requirement all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS/ steam boiler plant/ Incinerator plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of fuel feed pump unit reqd in small/ large shape based type with having single/ double solenoid valve system and also reqd rotation direction as clock wise rotation/ anti clock wise type complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for burner assembly of CHS/ steam boiler plant/ Incinerator plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of copper wounded electric motor of burner assembly unit with having single phase 230 volt system all as per existing type of sample/ size & model and suitable using for burner assembly of CHS/ steam boiler plant/ Incinerator plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of fuel feeding nozzle of suitable size/ type of rating capacity from 0.5 to 1.5 GPH and suitable for observing flame temperature maximum upto 85 degree centigrade complete all as per existing type of sample/ size & model & make and suitable using for CHS plant system and including jointing connection complete all as specified & directed.
S&F in replacement of fuel feeding nozzle of suitable size/ type of rating capacity from 2.5 to 7.0 GPH and suitable for observing flame temperature maximum upto 85 degree centigrade complete all as per existing type of sample/ size & model & make and suitable using for CHS/ Boiler plant/ Incinerator plant system and including jointing connection complete all as specified & directed.
S&F in replacement of heavy duty flexible type fuel pipe of size 15 mm dia bore made out of outer area by wire mesh bounded type complete all as per existing type of sample/ size with existing type length & model and suitable using for CHS/ Boiler plant/ Incinerator plant system and including jointing connection complete all as specified & directed.
S&F in replacement of fuel filter cartage element large & small shape type made out of paper/ wire mess cloth bounded type cartage based complete all as per existing type of sample/ size & model & make and suitable using for CHS/ Steam boiler plant/ Incinerator plant system complete all as specified & directed.
S&F in replacement of fuel filter outer body assembly complete made out of MS/ Aluminum/ Aluminium with transparent PVC body based type all as per existing type of sample/ size & model and suitable using for CHS/ steam boiler plant/ Incinerator plant system complete all as specified & directed.
S&F in replacement of thermostat switch / thermo couple switch complete all as per existing type of sample/ size & model & make and suitable using for CHS/ Steam boiler plant/ Incinerator plant burner system and including making electrical connection complete all as specified & directed.
S&F in replacement of LED display control unit (Subzero unit) complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS/ Boiler plant/ Incinerator plant paneling system and including making electrical connection complete all as specified & directed.
S&F in replacement of pressure/ temp/ fuel gauge meter etc with adaptor nut complete all as per existing type of sample/ size & model & make along with all details rating parameter of item are properly match to each other as per the existing replacement item and suitable using for CHS/ Boiler plant/ Incinerator plant system and including making connection complete all as specified & directed.
S&F in replacement of hooter/ siren unit complete all as per existing type of sample/ size/ sound & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS/ Boiler plant/ Incinerator plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of solenoid valve with coil unit complete all as per existing type of sample/ size & model & make and suitable using for CHS/ Boiler plant/ Incinerator plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of axial type blower fan complete all as per existing type of sample/ size & model & make and suitable using for in side area of burner assembly system of CHS/ Boiler plant/ Incinerator plant system complete all as specified & directed.
S&F in replacement of fire protection pipe piece of burner assembly along with connected fixing accessories complete all as per existing type of sample/ size & model & make and suitable using for in side area of burner assembly system of CHS plant system complete all as specified & directed.
S&F in replacement of heating element of rating capacity 3 KW to 5 KW complete all as per existing type of sample/ size & model and suitable using for AC/ CHS plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of heavy duty PVC made water/ fuel tank with storage capacity of 100 Ltr including making of hole for inlet/ outlet connection and providing of nipple with on /off valve/ stop cock in system complete all as per existing type of sample/ size & model and including making water/ fuel pipe line connection complete all as specified & directed.
Supply, fixing, testing & commissioning in replacement of cylindrical type with dish end hot water storage tank made out of heavy duty stainless steel sheet of grade 304L of 4 mm thick of storage tank capacity 1000 Ltrs along with electric heater backup minimum of electric rated capacity 6 to 9 KW with automatic control system of complete set and suitable for using of CHS/ boiler hot water purpose and also providing and fixing of outer body area insulated materials minimum 20 to 25 mm thick with aluminum foiled nitrile insulation covered with aluminum sheet cladding work complete outer area of tank including making of nos of reqd inlet and outlet, drain, overflow, return, safety valve on /off valve/ stop cock and metering gauge, heater connection of system purposed complete including making water/ fuel/ air/ steam pipe line connection & including testing it on load complete all as satisfaction and all as specified & directed.
Supply, fixing & testing and in replacement of complete burner assembly unit along with all type of it connected fitting/ fixing accessories complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS plant of rated capacity from 22000 Kcal/hrs to 50000 Kcal/hrs system and duly fixed and proper matching on existing CHS plant burner assembly system and including making electrical/ fuel connection and including testing it on load complete all as satisfaction and all as specified & directed.
Supply, fixing & testing and in replacement of complete burner assembly unit along with all type of it connected fitting/ fixing accessories complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS plant of rated capacity from 70000 Kcal/hrs to 90000 Kcal/hrs system and duly fixed and proper matching on existing CHS plant burner assembly system and including making electrical/ fuel connection complete and including testing it on load complete all as satisfaction and all as specified & directed.
Supply, fixing & testing and in replacement of complete burner assembly unit along with all type of it connected fitting/ fixing accessories complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS plant of rated capacity from 100000 Kcal/hrs to 200000 Kcal/hrs system and duly fixed and proper matching on existing CHS plant burner assembly system and including making electrical/ fuel connection and including testing it on load complete all as satisfaction and all as specified & directed.
Supply, fixing & testing and in replacement of complete burner assembly unit along with all type of it connected fitting/ fixing accessories complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS plant of rated capacity from 300000 Kcal/hrs to 400000 Kcal/hrs system and duly fixed and proper matching on existing CHS plant burner assembly system and including making electrical/fuel connection and including testing it on load complete all as satisfaction and all as specified & directed.
S&F in replacement of heating sensor complete all as per existing type of sample/ size & model & make and suitable using for CHS/ Boiler plant/ Incinerator plant system and including making electrical connection complete all as specified & directed.
S&F in replacement of DTC (Digital temp controller) display unit complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for CHS/Boiler plant/Incinerator plant paneling system and including making electrical connection complete all as specified & directed.
S&F in replacement of on/off push button with indication lamp complete set all as per existing type of sample/ size & model & make and suitable using for CHS/ Boiler plant/ Incinerator plant paneling system and including making electrical connection complete all as specified & directed.
S&F in replacement of heavy duty cylindrical rotational moulded polyethylene PVC made storage water tank with closed cap of tank storage capacity 500 Ltr including making of hole for inlet/ outlet connection and providing of nipple with on /off system and also making ball valve high pressure of PTMT with epoxy coated aluminum rod and high density of plastic ball screwed for existing line system complete all as per existing type of sample/ size & model and suitable using for CHS plant system and including making water/ fuel pipe line connection complete all as specified & directed.
S&F in replacement of heavy duty cylindrical rotational moulded polyethylene PVC made storage water tank with closed cap of tank storage capacity 1000 Ltr including making of hole for inlet/ outlet connection and providing of nipple with on /off system and also making ball valve high pressure of PTMT with epoxy coated aluminum rod and high density of plastic ball screwed for existing line system complete all as per existing type of sample/ size & model and suitable using for CHS plant system and including making water/ fuel pipe line connection complete all as specified & directed.
S&F in replacement of electrical power contactor of rating capacity 32 Amp 3/4 pole 415 volt along with auxiliary contactor with NO/ NC complete all as per existing rating capacity with sample/ model & make suitable for safe operational of existing panel controlling system complete all as specified & directed.
S&F in replacement of single phase preventer complete all as per existing size/ sample / model and suitable use for paneling system complete all as specified & directed.
M&L for disconnecting of water pipe lines connections along with outer grill from system any type/ size any in position and removing of electric wiring connections from each ceiling mounted cassette type of square shape fan coil condensing unit system any type any model and any capacity and also dismantling /opening of all type of fitted nut, bolt locking patch and filter parts from inside and outside area of complete system including providing adequate material and lobour and all type of T&P for cleaning and servicing of fan coil unit and its connected fixing accessories of complete system including cleaning it with the help of high efficiency air pressure blower / vacuum pump including providing of suitable cleaning materials for clean of body area and removing dust particles and sludge and also providing of oiling and greasing servicing work on moving parts etc of body system after complete cleaning /servicing work, refixing the all removing items on same to its original position including checking of tightness of all the nuts & bolts of units system complete all as specified and directed.
M&L for disconnecting of water pipe lines connections along with outer grill from system any type/ size any in position and removing of electric wiring connections from each wall mounted hanging based indoor type of rectangular shape fan coil condensing unit system any type any model and any capacity and also dismantling /opening of all type of fitted nut, bolt, locking patch and filter parts from FCU area of complete system including providing adequate material and lobour and all type of T&P for cleaning and servicing of fan coil unit and it connected fixing accessories of complete system including cleaning it with the help of high efficiency air pressure blower / vacuum pump including providing of suitable cleaning materials for clean of body area removing of dust particles and sludge and also providing of oiling and greasing servicing work on moving parts etc of body system after complete cleaning /servicing work, refixing the all removing items on same to its original position including checking of tightness of all the nuts & bolts of units system complete all as specified and directed.
Supplying, mixing and filling of mono ethylene glycol concentrate in sealed packed drum along with the necessary additives and inhibitor in cognition, required for smooth function/ operation of CHS plant and network system. The mixing freezing temperature shall be minus 10 degree complete all as specified and directed.
Supply, fixing & testing and in replacement of Hi wall mounted indoor hanging based hot and cold type fan coil units (FCU) complete with hanging bracket base frame of single phase operating system 230 volt 50Hz of FCU rated capacity 3000kcal/hr or 1.0 Ton capacity unit complete set all as per existing type of sample/ size along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item along with having complete all connected inbuilt fixing & fixture accessories like condenser coil, blower fan with motor and front grill with PCB alonwith operating display control panel with hand operating remote control etc along with providing of both inlet and outlet hot water pipe line connection and adaptor along with open & closing valve system of complete unit system and suitable using it for CHS plant hot water circulation system including making of electrical /water pipe line connection complete all as satisfaction & all as specified & directed.
Ditto all per serial item No. 143.00 described here-in-before but wall mounted hanging based hot and cold type fan coil units complete with hanging bracket base frame of single phase operating system 230 volt 50Hz of FCU rated capacity 4500kcal/hr or 1.5 Ton capacity unit complete set.
Ditto all per serial item No. 143.00 described here-in-before but wall mounted hanging based hot and cold type fan coil units complete with hanging bracket base frame of single phase operating system 230 volt 50Hz of FCU rated capacity 6000kcal/hr to 6300kcal/hr or 2.0 Ton capacity unit complete set.
Supply, fixing & testing in replacement of Cassette type square shape size indoor ceiling mounted hanging based hot and cold type fan coil units (FCU) complete with bracket and outer cover base with grill frame of single phase operating system 230 volt 50Hz of FCU rated capacity 4500kcal/hr or 1.5 Ton capacity unit complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item along with having complete all connected in built fixing & fixture accessories like condenser coil, blower fan with motor and front grill with PCB alonwith operating display control panel with hand operating remote control etc along with providing of both inlet and outlet hot water pipe line connection and adaptor along with open & closing valve system of complete unit system and suitable using it for AC/CHS plant hot water circulation system including making of electrical/ water pipe line connection complete all as satisfaction & all as specified & directed.
Ditto all per serial item No. 146.00 described here-in-before but Cassette type square shape size ceiling mounted hanging based hot and cold type fan coil units complete with hanging bracket base frame of single phase operating system 230 volt 50Hz of FCU rated capacity 6000kcal/hr to 6300kcal/hr or 2.0 Ton capacity unit complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item complete all as satisfaction & all as specified & directed.
Ditto all per serial item No. 146.00 described here-in-before but Cassette type square shape size ceiling mounted hanging based hot and cold type fan coil units complete with hanging bracket base frame single/ three phase operating system of operating system of rated capacity 9000 to 15000 kcal/hr or 3 to 5 Ton capacity unit complete set .complete set all as per existing type of sample/ size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item complete all as satisfaction & all as specified & directed.
S&F in replacement of wall mounted based FCU blower fan motor with blower and connected rubber bush/ bearing complete set all as per existing type of sample/ size/ capacity & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for FCU system and including making electrical connection complete all as specified and directed.
S&F in replacement of wall mounted based FCU system PCB card unit complete all as per existing type of sample/ size & rated capacity and existing model and suitable using for FCU system and including making electrical connection complete all as specified and directed.
S&F in replacement of wall mounted based FCU front operating display control panel unit complete all as per existing type of sample/size & rated capacity and existing model & make and suitable using for FCU system and including making electrical connection complete all as specified and directed.
S&F in replacement of air release vale made out of brass/ copper based material complete all as per existing type of sample/size & existing model & make and suitable using for pipe line system and including making electrical connection complete all as specified and directed.
S&F in replacement of pressure switch unit complete all as per existing type of sample/ size & existing model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for system and including making electrical connection complete all as specified and directed.
S&F in replacement of cast iron sluice valve of size 25 mm dia bore with having flanged and drilled ends, type pattern, along with having spindle, operating wheel including providing suitable size jointing materials as rubber washers/ gaskets along with suitable type/ size of bolts and nuts, etc, complete all as specified and directed.
S&F in replacement of MS pipe line of size 40/ 50 mm bore medium grade along with providing all type/ sizes fittings and including duly fixing and jointing with the help of cutting/ welding/ brazing of hot/ cold any type/ description of work or and laying in trenches/ fixed along walls or laid under floors/ wall after including replacing, jointing/ connection along with existing branch pipeline connections system works all as specified and directed.
S&F in replacement of MS pipe line of size 20/ 25 mm bore medium grade along with providing all type/ sizes fittings and including duly fixing and jointing with the help of cutting/ welding/ brazing of hot/cold any type/ description of work or and laying in trenches/ fixed along walls or laid under floors/ wall after including replacing, jointing/ connection along with existing branch pipeline connections system works all as specified and directed.
S&F in replacement of MS pipe line of size 15 mm bore medium grade along with providing all type/ sizes fittings and including duly fixing and jointing with the help of cutting/ welding/ brazing of hot/ cold any type/ description of work or and laying in trenches/ fixed along walls or laid under floors/ wall after including replacing, jointing/ connection along with existing branch pipeline connections system works all as specified and directed.
S&F in replacement of diffuser plate complete all as per existing type of sample/ size & model & make and suitable using for CHS/ steam boiler plant/ Incinerator plant system and including making /jointing connection complete all as specified and directed.
Supply, mixing, cleaning and descaling cum charging of water softener plant system through providing of industrial salt all as per existing type of sample/ type complete and suitable used for treatment of hard water to convert soft water proposed complete all as specified and directed.
S&F in replacement of electrical and steam based operating iron of rating load capacity 900W single phase 230 volt operating system unit complete with having thumb touch operating switch and both electrical / steam cable and pipe connection system and suitable using for laundry system and including making electrical connection complete all as specified and directed.
S&F in replacement of defected parts from water circulation pump motor and including disconnection of electric and suction and delivery pipe line connection from existing Diesel fuel / water circulation / feeding pump suitable for pump motor of rated capacity from 0.5 HP to 2 HP single/ three phase system any type any size complete including removing from site and carrying out cleaning, servicing, overhauling and maint work etc including repair/ replacement of defected unserviceable parts which is reqd at site like bush/ bearing set with ring, water seal gasket, shaft, fan impeller, gland packing, shaft sleeves, gasket set, cooling fan, inlet/ outlet connection adaptor & remetallic of shaft work and also replacement of damage / broken of body and it connected parts etc and refixing if found any defected parts on eqpt and replacing the same with new one parts complete all as per existing type of sample/ size & rated capacity and existing model and properly match to each other as per the existing replacement item and suitable using for pump motor system and making it perfectly serviceable after completion of cleaning/ servicing work then making oiling & greasing work for all moving parts and thereafter also re fixing the all removing parts on same to its original position including checking/ tightening and replacement of minor defected item like of all type of nut, bolt, screws, gasket, electric wire connection etc and after making/ jointing of electric/ pipe lines connections and also making welding work if required for any broken/ damaged part at site and after completion of complete job checking all type of leakage in system and ensure that making it sound less & leakages proof and including testing on load complete all as satisfaction and all as specified & directed.
Ditto all per serial item No. 161.00 described here-in-before but water circulation pump suitable for motor of rated capacity from 3 HP to 5 HP three phase system complete.
Ditto all per serial item No. 161.00 described here-in-before but water circulation pump suitable for motor of rated capacity from 7.5 HP to 10 HP three phase system complete.
M&L for cleaning, descaling of Steam boiler coil of rated capacity 600Kg/Hr or all as per existing type of capacity & model complete and suitable used it for laundry boiler plant system including descaling of coil & dismantling of electrical/ fuel/ water along with connected mechanical parts fitted on body system in any position and also opening of inlet & outlet water pipe line connection of both side end of coil and after carried over work like descaling of inside area of boiler coil system with the help of full filling of chemical solution compound/ Acid for washing of coil before descaling of boiler coil to allow the descaling chemical solution to hold for 2 hr for chemical reaction. After the completion of chemical reaction for give duration hrs also providing of through separate high speed pressure pump & making the suitable size/ type of piping flange with nipple along with flexible type/ size of pipe along with water tank arrangement for the purpose of circulation the chemical solution for 4 hrs to 6 hrs duration and ensuring that the coil has been descaled upto max clean range and after descaling/ servicing work also re fixing the all removing parts on same to its original position including checking/ tightening and replacement of minor defected item like of any type of nut, bolt, screws, gasket, electric wire and its connection etc and after making/ jointing of electric and water pipe lines connections and after completion of job circulating clean water in the tubes of boiler coil and draining out it complete and after checking all type of leakage for water/fuel in system and ensure that making it leakages proof and including testing it on load complete all as satisfaction and all as specified & directed. Note - (a) Qty of descaling Item/chemical etc which is incorporated for cleaning of Steam boiler coil system will be measured and paid separately under respective items of this schedule. (b) The quoted rate shall be inclusive of T&P required at site to complete the Job. Nothing extra shall be admissible to the contractor on this ground.
Supply and mixing of powder based descaling compound material all as per existing type of sample/ type of existing rated ratio capacity & make as recommended by boiler manufacture complete and suitable used for descaling of steam boiler coil any type any size complete all as directed.
Supply and mixing Hydro caloric acid (HCL) concentrate all as per existing type of sample/ type of rated ratio capacity & type complete and suitable used for descaling of steam boiler coil any type any size complete all as directed.
S&F in replacement of heavy duty steam pressure gate/ ball /hand shut down valve/ blow down of size 15 to 25 mm dia all as per existing type of sample/ size & model & make and suitable using for existing plant system and including making connection complete all as specified and directed.
S&F in replacement of NRV of size 15 to 25 mm dia bore heavy duty and having capacity to adapting and to stop the high pressure of steam pressure / air pressure system all as per existing type of sample/ size & model & make and suitable using for existing plant / eqpt system and including making connection complete all as specified and directed.
S&F in replacement of heavy duty inlet/ outlet hose pipe of size 40 to 80 mm dia bore upto 2 feet long compete all as per existing type of sample/ size and length & including making connection complete all as specified and directed.
M&L for dismantling & taking out existing defective/ burnt out of electric motor of any type /description & in any type/size and any model of rating capacity 0.5 HP to 2 HP any type/size of single / three phase type and carry for motor new rewinding work with the help of providing of super enameled copper winding wire of superior quality of all as per existing size/ gauge & No of turns and also providing insulating materials such as illumines paper, cotton tape, glass sleeve, insulating varnish etc all as per instructions including cutting and taking out existing burnt/ short circuited winding wires and including replacement of existing defected parts if found at site and replacement by new bushes, bearings & starting condenser, cooling fan, re-metallic of shaft work etc complete system and they after re-assembling and re-fixing of the same motor at its original position after repair, making all necessary electrical connections and than testing on load complete all as specified and directed.
Ditto all per serial item No. 170.00 described here-in-before but electric motor of any type /description & in any model of rating capacity 3 HP to 5 HP any type/ size of three phase type and carry for motor new rewinding work and after testing on load complete all as specified and directed.
Ditto all per serial item No. 170.00 described here-in-before but electric motor of any type /description & in any model of rating capacity 7.5 HP to 10 HP any type/ size of three phase type and carry for motor new rewinding work and after testing on load complete all as specified and directed.
Ditto all per serial item No. 170.00 described here-in-before but electric motor of any type /description & in any model of rating capacity 12 HP to 20 HP any type/size of three phase type and carry for motor new rewinding work and after testing on load complete all as specified and directed.
S&F in replacement of inside area first layer of roller Flannel Cloth suitable used for flat work ironer size 32''x13'' complete all as per existing type of sample/size & length along with all details of item are properly match to each other as per the existing replacement item and suitable using for flat work ironer of laundry plant system and including providing of all connected jointing / fitting fixing accessories complete and making jointing connection complete all as specified and directed.
S&F in replacement of outer area second layer of roller Final cover suitable used for flat work ironer size 32''x13'' complete all as per existing type of sample/size & length along with all details of item are properly match to each other as per the existing replacement item and suitable using for flat work ironer of laundry plant system and including providing of all connected jointing / fitting fixing accessories complete and making jointing connection complete all as specified and directed.
S&F in replacement heavy duty MS pipe line fittings from plant /eqpt of any shape/ size and including replacement with new as heavy duty MS pipe line with fitting, joint etc all as per site requirement including necessary jointing, threading, welding work, flange, gasket of any size with nut bolts complete all as directed.
M&L for flame proof high temperature resistance painting work required for steam boiler plant/ CHS/ Incinerator boilers plant any type any size & model capacity along with its all type of connected fitting & fixing accessories of the complete area system by flame proof synthetic high temperature enamel existing type of colour painting work including before painting work scraping old painting complete surface by steel wire brush after cleaning filling cavities with filler, one coat after cleaning all dust complete all as specified and directed.
M&L for water proof high quality resistance painting work required for laundry plant area machine fitted any type any size & model capacity for MS based system along with it all connected all type of pipe line and valve & fitting & fixing accessories of the complete area system by water proof synthetic high quality enamel existing type of colour painting by work including before painting work scraping old rusted painting surface complete surface by steel wire brush after cleaning filling cavities with filler, one coat after cleaning all dust complete all as specified and directed.
S&F in replacement of gland washer nitrile rubber all as per code/ mode- HTB/2N of Make: As per all as per existing type of sample/size and suitable using for steam boiler trilex spray pump system and suitable using and complete replacement of each spray pump washer of qty nine nos washer set complete and including making jointing complete all as specified and directed.
S&F in replacement of valve assembly all as per code/ mode- HTB/VA of Make: As per all as per existing type of sample/size and suitable using for steam boiler trilex spray pump system and suitable using and complete replacement of each spray pump washer of qty six nos washer set complete and including making jointing complete all as specified and directed.
S&F in replacement and testing of Triplex Spray pump of rating capacity 24 Ltrs/hr complete unit all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for laundry plant Steam boiler system of rated capacity 600Kg/Hr and duly fixed on steam boiler plant system and including making electrical & water connection complete all as specified and directed.
S&F in replacement and testing of monoblock centrifugal pump motor of rated capacity 0.5 HP to 1 HP single phase driven type complete set all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and suitable using for feeding / circulation of hot/cold water supply system and with having water flow capacity up to 100 LPM & maximum upto 22 mtr head complete including providing of all connected fitting and fixing accessories complete all as specified and directed.
Ditto all per serial item No. 182.00 described here-in-before but monoblock centrifugal pump motor of rated capacity 1.5 HP to 2 HP single phase driven type complete set
S&F in replacement of MCCB 100/125 Amps 3/4 pole with breaking capacity 16 to 36KA 3 phase 415 volt AC supply system complete all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and having adjustable setting type and also making suitable size / type of electric wiring connection complete all as specified and directed.
Ditto all per serial item No. 184.00 described here-in-before bu MCCB 160 Amps 3/4 pole with breaking capacity 16/25KA 3 phase 415 volt AC supply system complete
Ditto all per serial item No. 184.00 described here-in-before but MCCB 200 Amps 3/4 pole with breaking capacity 16/25KA 3 phase 415 volt AC supply system complete
Ditto all per serial item No. 184.00 described here-in-before but MCCB 250 Amps 3/4 pole with breaking capacity 16/25KA 3 phase 415 volt AC supply system complete
S&F in replacement of MPCB of model/type TCMS 100H of rating capacity 55 to 75 A 3/4 pole with breaking capacity 8 to 10KA 3 phase 415 volt 50HZ AC supply system with having adjustable control setting knob with test button complete all as per existing type of sample/size & model & make along with all details rating capacity & technical specification of item are properly match to each other as per the existing replacement item and having adjustable setting type and also making suitable size / type of electric wiring connection complete all as specified and directed.
Supplying and laying in replacement and testing of 40 mm to 80 mm dia bore 3 layer poly propylene random copolymer pipes (PPR) or composite pipes complete with all type of PPR fitting all as per existing type of sample/size & length and confirming ISI mark complete with all type of jointing fittings & fixture of material in any position of the system by in any method and along with duly covered it insulated materials complete all as specified and directed.
Supplying and laying in replacement and testing of 15 mm to 32 mm dia bore 3 layer poly propylene random copolymer pipes (PPR) or composite pipes complete with all type of PPR fitting all as per existing type of sample/size & length and confirming ISI mark complete with all type of jointing fittings & fixture of material in any position of the system by in any method and along with duly covered it insulated materials complete all as specified and directed.
S&F in replacement and testing of 40 mm to 80 mm dia bore 3 layer poly propylene random copolymer gate valve/ butter fly/ Ball valve/ Hand shut down valve complete with all type of PPR fitting all as per existing type of sample/ size & length and confirming ISI mark complete with all type of jointing fittings & fixture of material in any position of the system by in any method and along with duly covered it insulated materials complete all as specified and directed.
S&F in replacement and testing of 15 mm to 32 mm dia bore 3 layer poly propylene random copolymer gate valve/butter fly/Ball valve/Hand shut down valve complete with all type of PPR fitting all as per existing type of sample/size & length and confirming ISI mark complete with all type of jointing fittings & fixture of material in any position of the system by in any method and along with duly covered it insulated materials complete all as specified and directed.
S&F in replacement of polyurethane inlet /out let hot water pipe line connection pipe of size 15 mm dia bore with open & closing valve along with adaptor & connectors suitable for FCU system complete all as per existing type of sample/size & model and suitable using it for CHS plant hot water circulation system and making of water pipe line connection complete all as specified and directed.
Supply, laying & fixing in replacement of inside area initial layer of roller wire mess type wool / carbon based type steel wool suitable used for flat work ironer system complete all as per existing type of sample/size & length along with all details of item are properly match to each other as per the existing replacement item and suitable using for flat work ironer of laundry plant system and including providing of all connected jointing / fitting fixing accessories complete and making jointing connection complete all as specified and directed.
M/S Razdan Buildersand suppliers (BID ID -3152870)
M/S M.A.S ELECTRICALS (BID ID -3151087)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .