| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC BOOTH NO 15 SHOPPING COMPLEX URBAN ESTATE PHASE II JALANDHAR CITY PIN 144022 | JALANDHAR | PUNJAB | 144022 | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹23.7 L+₹2.8 L (13.6%)Rejected-Finance H NO 21666 POWER HOUSE ROAD STREET NO 9 BATHINDA PB 151001 | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹24.4 L+₹3.6 L (17.1%)Rejected-Finance 158 PADRI BAZAR TINKONIYA NO 1 PARVATIPURAM GORAKHPUR GORAKHPUR UTTAR PRADESH 273014 | GORAKHPUR | UTTAR PRADESH | 273014 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹25.2 L+₹4.4 L (20.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹33.9 L+₹13.1 L (62.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹96,660
Closing Date
25 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
MANNING AND OPERATION OF VARIOUS SEWAGE INSTALLATIONS AND CONNECTED REPAIR/ MAINTENANCE UNDER GE (EAST) JALANDHAR CANTT
2020_MES_387444_2
GE/JULL/ET-49/2020-21
Open Tender
Civil Works
Item Rate
335 days
Jalandhar Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹96,660
Yes
6 Feb 2021
10 Dec 2020
28 Dec 2020
10 Dec 2020
25 Dec 2020
12 Dec 2020
60 days
Amount
Manning & operation of sewage treatment plant of capacity 400 KLD including the operation of silent DG set of capacity 62.5 KVA, panel boards, treated water pumps and raw sewage pump as mentioned below by providing qualified operator with ITI diploma in Electrical/ Fitter/ Diesel Mechanic trade with minimum 02 year experience or matriculate with 05 years minimum experience of plant from any Govt. Department/ Private Sector, responsible for plant operations in 02 shifts/ day (one Operator in each shift of 8 hrs). (a) Raw Sewage Lifting Pumps: KSB Make, Model-RTU PE/115-12 65, Sr No. 831705714 & 731784430, 1.1 KW /1.5 H.P, 2900 RPM (02 Nos). (b) Air diffusing system (i) Set of Air Blower, Everest Make, Model M 5075, Capacity 160m3/ hr, Sr. No EB08011644 & EB08011645- 02 Nos (1 Working + 1 Standby). (ii) Set of motors for Air blowers, Make - Crompton Greaves, 7.5 HP/ 1450 RPM, Sr No. 1832 J/GLG-4172 & 1832 J/ GLG-3909 - 02 Nos (1 Working + 1 Standby). (iii) Air diffusing system in FAB-I & FAB-II - 01 set. (iv) Air diffusing system in Raw sewage collection sump- 01 set. (v) FAB Media- 01 Lot. (c) Chlorine Dosing system (i) Chlorine mixing tank/storage tank and constant dosing system- 01 set. (ii) Alum mixing tank and dosing system- 01 set.
(d) Clari-settler system. (e) Tube Deck Media- 01 Lot. (f) MCC Panel complete system- 01 No. (g) Course Bar screen gate - 01 No. (h) Sludge Drying Bed shutter Gate- 06 Nos. (j) MS Piping net work (Complete system with all accessories like valve, flanges, reducers etc.)- 01 Lot. (k) FAB & Tube Deck Media- 01 set each. (l) MCB distribution box complete with MCB's- 01 Set. (m) Water submersible pump set - 1 HP, Make KSB, single Phase, 230 volts, 50 Hz with MC Panel for bore well- 01 No. (n) Treated water sewage pump of capacity 5 HP 415 Volts- 02 Nos Notes : (a) Contractor will deploy ITI holder Electrical/ Fitter/ Diesel Mechanic trade 01 No each for 02 shifts per day with arrangement of reliever for their weekly rest permanent minimum for 11 months from the date of work order. (b) Electrical safety equipment like glovers, helmet, electrical tool kit, etc will be given to electricians on duty by the contractor and rate for these items will be deemed to be included in the quoted rates of this item
Manning & Operation of two sewage installations at 'Phoola Road' (MAP Ph-I) & BI Lines (MAP Ph-I) comprising of the following machinery equipment by providing qualified operator with ITI diploma in Electrical/ Fitter/ Diesel Mechanic trade with minimum 02 year experience or matriculate with 05 years minimum experience of plant from any Govt. Department/ Private Sector, responsible for plant operations in 2 shifts/ day (one Operator in each shift of 8 hrs):- (a) Phoola Road (Map Ph-l) (i) Submersible pump set horizontal type directly coupled with 3 phase electric motor 50 HZ, 440 V, capacity 5 HP on common base plate discharge 650 LPM at head 13.5m with cyclic control panel Qty- 02 No. Make- Mody Model MS 252 (ii) DG set complete with alternator of 12.5 KVA with 12 volts 90 AH battery for stand by supply. (iii) LT panel for DG set complete with 63 Amp F.P. on load change over switch & 40 Amp TP MCB Isolator. (iv) Suction & delivery valve with GI pipe line 100 mm bore complete. (b) BI Lines (Map Ph-I) (i) Submersible pump set horizontal type directly coupled with 3 phase electric motor 50 HZ, 440 V, capacity 5 HP on common base plate discharge 650 LPM at head 13.5 mtr. with cyclic control panel Qty- 02 No., Make- Mody Model MS 252
(ii) DG set complete with alternator of 12.5 KVA with 12 volts 90 AH battery for standby supply. (iii) LT panel for DG set complete with 63 Amp F.P. on load change over switch & 40 Amp TP MCB Isolator. (iv) Suction & delivery valve with GI pipe line 100 mm bore complete. Notes : (a) Contractor will deploy ITI holder Electrical/ Fitter/ Diesel Mechanic trade 01 No each for 02 shifts per day with arrangement of reliever for their weekly rest permanent minimum for 11 months from the date of work order. (b) Electrical safety equipment like glovers, helmet, electrical tool kit, etc will be given to electricians on duty by the contractor and rate for these items will be deemed to be included in the quoted rates of this item
Manning & Operation of two sewage installations at Jindan Road ( Map Ph-l) & Hudson Lines (Map Ph-I) comprising of the following machinery equipment by providing qualified operator with ITI diploma in Electrical/ Fitter/ Diesel Mechanic trade with minimum 02 year experience or matriculate with 05 years minimum experience of plant from any Govt. Department/ Private Sector responsible for plant operations in 2 shifts/ day (one Operator in each shift of 8 hrs):- (a) Jindan Road ( Map Ph-l) (i) Submersible pump set horizontal type directly coupled with 3 phase electric motor 50 HZ, 440 V, capacity 2 HP on common base plate discharge 325 LPM at head 9m with cyclic control panel Qty - 02 No. Make - Mody Model MS 252. (ii) DG set complete with alternator of 7.5 KVA with 12 volts 90 AH battery for standby supply. (iii) LT panel for DG set complete with 63 Amp F.P. on load change over switch & 40 Amp TP MCB Isolator. (iv) Suction & delivery valve with GI pipe line 100mm bore complete. (b) Hudson Lines (Map Ph-l) (i) Submersible pump set horizontal type directly coupled with 3 phase electric motor 50 HZ, 440 V, capacity 2 HP on common base plate discharge 325 LPM at head 9m with cyclic control panel Qty - 02 No., Make - Mody Model MS 252.
(ii) DG set complete with alternator of 7.5 KVA with 12 volts 90 AH battery for standby supply. (iii) LT panel for DG set complete with 63 Amp F.P. on load change over switch & 40 Amp TP MCB Isolator. (iv) Suction & delivery valve with GI pipe line 100 mm bore complete. Notes : (a) Contractor will deploy ITI holder Electrical/ Fitter/ Diesel Mechanic trade 01 No each for 02 shifts per day with arrangement of reliever for their weekly rest permanent minimum for 11 months from the date of work order. (b) Electrical safety equipment like glovers, helmet, electrical tool kit, etc will be given to electricians on duty by the contractor and rate for these items will be deemed to be included in the quoted rates of this item
Manning & Operation of sewage installations at Thimayya Park comprising of the following machinery equipment by providing qualified operator with ITI diploma in Electrical/ Fitter/ Diesel Mechanic trade with minimum 02 year experience or matriculate with 05 years minimum experience of plant from any Govt. Department/ Private Sector, responsible for plant operations in 02 shifts/ day (one Operator in each shift of 8 hrs) :- (a) Non clog self priming centrifugal pump set horizontal type directly coupled with 3 phase electric motor 50 HZ, 440V, 1450 RPM, capacity 11 KW/ 15 HP on common base plate discharge 17 ltrs/ second at head 13 mtr qty - 02 Nos. Make- Kirloskar. (b) LT panel comprising of Ammeter, Voltmeter, Incoming & outgoing, main switch with individual motor starter & wiring complete all as specified. (c) Suction & delivery valve connecting parts etc. complete. (d) Dewatering of pump of capacity 1 HP single phase as and when required for dewatering. Notes : (a) Contractor will deploy ITI holder Electrical/ Fitter/ Diesel Mechanic trade 01 No each for 02 shifts per day with arrangement of reliever for their weekly rest permanent minimum for 11 months from the date of work order.
(b) Electrical safety equipment like glovers, helmet, electrical tool kit, etc will be given to electricians on duty by the contractor and rate for these items will be deemed to be included in the quoted rates of this item
Manning & Operation of sewage installations at Solanki Line comprising of the following machinery equipment by providing qualified operator with ITI diploma in Electrical/ Fitter/ Diesel mechanic trade with minimum 02 year experience or matriculate with 05 years minimum experience of plant from any Govt. Department / Private Sector, responsible for plant operations in 2 shifts/ day (one Operator in each shift of 8 hrs):- (a) Non clog self priming centrifugal pump set horizontal type directly coupled with 3 phase electric motor 50 HZ, 440V, 1450 RPM, capacity 11 KW/15 HP on common base plate discharge 17 ltrs/ second at head 13 mtr qty - 01 Nos. Make – Kirloskar. (b) LT panel comprising of Ammeter, Voltmeter, Incoming & outgoing, main switch with individual motor starter & wiring complete all as specified.(c) Suction & delivery valve with GI pipe line 100 mm bore complete. Notes : (a) Contractor will deploy ITI holder Electrical/ Fitter/ Diesel Mechanic trade 01 No each for 02 shifts per day with arrangement of reliever for their weekly rest permanent minimum for 11 months from the date of work order. (b) Electrical safety equipment like glovers, helmet, electrical tool kit, etc will be given to electricians on duty by the contractor and rate for these items will be deemed to be included in the quoted rates of this item
Manning & Operation of DG Set installations at Kora Road Exchange comprising of the following machinery equipment by providing qualified operator with ITI diploma in Electrical/ Fitter/ Diesel mechanic trade with minimum 02 year experience or matriculate with 05 years minimum experience of plant from any Govt. Department/ Private Sector, responsible for plant operations in 01 shifts/ day (one Operator in each shift of 8 hrs):- (a) DG set complete with alternator of 62.5 KVA with 12 volts 180 AH battery. (b) LT panel complete with change over switch. (c) Internal electric wiring as per inventory of buildings. Notes : (a) Contractor will deploy ITI holder Electrical/ Fitter/ Diesel Mechanic trade 01 No each for 01 shifts per day with arrangement of reliever for their weekly rest permanent minimum for 11 months from the date of work order. (b) Electrical safety equipment like glovers, helmet, electrical tool kit, etc will be given to electricians on duty by the contractor and rate for these items will be deemed to be included in the quoted rates of this item
Manning & Operation of DG Set installations at 7011 EME Wksp comprising of the following machinery equipment by providing Operator qualified with ITI diploma in Electrical/ Fitter/ Diesel mechanic trade with minimum 02 year experience or matriculate with 05 years minimum experience of plant from any Govt. Department/ Private Sector, responsible for plant operations in 02 shifts/ day (one Operator in each shift of 8 hrs):- (a) DG set complete with alternator of 125 KVA with 12 volts 180 AH battery. (b) LT panel complete with change over switch. Notes : (a) Contractor will deploy ITI holder Electrical/ Fitter/ Diesel Mechanic trade 01 No each for 02 shifts per day with arrangement of reliever for their weekly rest permanent minimum for 11 months from the date of work order. (b) Electrical safety equipment like glovers, helmet, electrical tool kit, etc will be given to electricians on duty by the contractor and rate for these items will be deemed to be included in the quoted rates of this item
Providing Helper (MTS) to assist the operator as and when required responsible for plant operation. (02 shifts/ day, one in each shift of 8 hrs) and responsible for cleaning of plant/ area for uprooting the grass, shrubs, vegetation except the tree and cleaning of the maintaining STP and sewage installations area upto the fencing or boundary wall Notes : (a) Contractor will deploy Helper (MTS) 01 No each for 02 shifts per day with arrangement of reliever for their weekly rest permanent minimum for 11 months from the date of work order. (b) Electrical safety equipment like glovers, helmet, electrical tool kit, etc will be given to electricians on duty by the contractor and rate for these items will be deemed to be included in the quoted rates of this item
Treated water sample collection and analysis from one of the laboratory approved by Punjab pollution control board once in a month or as and when directed and maintain the record of testing. The parameters to be maintained shall be as under:- (a) BOD (Parameter) - < 30 mg/l (Characteristics of treated water). (b) COD (Parameter) - < 250 mg/l (Characteristics of treated water). (c) TSS & TDS (Parameter) - < 50 mg/l (Characteristics of treated water). (d) Coli form Count (Parameter) - < 1000 counts/100 ml (Characteristics of treated water). (e) PH (Parameter)- 6.5 - 8.5 (Characteristics of treated water). (f) Oil & Grease (Parameter). (g) Records of all above parameters found in testing shall be maintained by the contractor without any extra cost to the Deptt. (h) The contractor shall maintain clear record of attendance for workmen and staff. (j) The contractor shall get the routine maintenance like oiling, greasing tightening of nuts bolts, cleaning of impellers/ Suction pipes, foot valves including taking out and re-fixing or any other petty repair required for the smooth working of pump sets etc under the overall amount quoted. However major repair if any shall be carried out by the Deptt. under their own arrangements. Decision of GE shall be final and binding in this regard.
(k) The contractor shall provide sufficient man power for removal, spreading and leveling of dry sludge and other sewage waste which come out from the STP at disposal area as directed by Engineer-in-Charge and for manual handling or cleaning of sewage waste, if required, to maintain the hygienic condition of nearby area adjacent to STP Nothing extra shall be payable on this account. (l) The contractor shall ensure that the treated water reaches to the area connected for the purpose of arboriculture through pipe line laid. Opening/ closing of valves & minor leakages shall be repaired within the overall cost. However major repair if any such as replacement of U/S pipe/valves etc shall be carried out by the deptt under departmentally arrangements. (m) Serviceability of all standby pumps/ machines shall be checked and tested in routine by contractor without any additional cost. (n) Contractor shall be responsible for security and safety of all installations and assets irrespective of 2 OR 3 shifts within overall cost of operation quoted by the contractor. Nothing shall be paid extra on this account.
Supply & used in treated sewage water, Poly Aluminium Chloride in liquid form effective in both high and low turbidity of grade high basicity complete all as specified. In company sealed packing of fresh lot. Make: Vikram PAC of M/S Grasim Industries Ltd (Chemical Division)/ Renuka Water/ BM AQUA Tech Pvt Ltd/ AQUA FIT.
Supply & used in treated sewage water for calcium Hypo-chloride for chlorination having 65% to 70% chlorine contents in granular form Hi-strength in company sealed packing of fresh lot complete all as specified. Make: Vikram PAC of M/S Grasim Industries Ltd (Chemical Divison)/ Renuka Water/ BM AQUA Tech Pvt Ltd/ AQUA FIT
M&L cleaning of sump well at Thimmayya Park (Jindan Rd) of sump well size 5.50 mtr dia, 9.20 mtr depth and making in side area dry by de-silting and removal of deposited solid based sludge including shifting and depositing to approved area to as distance exc. 1.0 Km but n. exc. 3 Km from sump well site complete all as specified.
M&L cleaning of sump well at Solanki Line of sump well size 7.40 mtr dia, 7.00 mtr depth and making in side area dry by de-silting and removal of deposited solid based sludge including shifting and depositing to approved area to a distance exc. 1.0 Km but n. exc. 3 Km from sump well site complete all as specified.
M&L cleaning of sump well at Jindan Road, Hudson Line, B1 Line and Phoola Road under MAP Ph- I of sump well size 4.50 mtr dia, 10.00 mtr depth and making in side area dry by de-silting and removal of deposited solid based sludge including shifting and depositing to approved area to a distance exc. 1.0 Km but n. exc. 3 Km from sump well site complete all as specified.
M&L taking out unserviceable non clog submersible motor pump with suction pipe brought out from 12 mtr deep well with the help of tripod and disconnecting suction pipe from the electric non clog submersible motor & pump set of cap 5HP, 3 phase, 440 v 50 HZ and transporting to shifting same to workshop for opening, dismantling and cutting of old burnt winding wire of motor and rewinding of same existing size of annealed copper winding wire, insulation material, replacement of old oil seal, ball bearing, change of oil and replacement of old connection lead with superior quality PVC insulated FRLS wire with stranded copper conductor with sleeves from motor to connection plate and reassembling the motor, shifting to site and refitted with suction pipe, lowering to sump well 12 mtr deep with the help of tripod for installation, connecting, commissioning and testing on full load complete all as specified and directed.
All as per item No. 15.00 but here-in-before capacity 2/3 HP
M&L disconnecting electric motor 15 HP 3 phase, 440 volts 50 Hz and transporting to workshop, dismantling same and taking out motor assembly removing burnt winding coil of starter, cleaning the complete starter and rotor with carbon tetra chloride solution, rewinding the starter coil with super enameled copper conductor of proper size/ gauge as per existing, inserting the new rewinding coils of starter duly varnishing and insulated with superior quality insulation material, replacement of ball bearing as per existing size and sample and old connection lead with superior quality PVC insulated FRLS wire with stranded copper conductor with sleeves from motor to connection plate, reassembling the motor, shifting to site, connecting, commissioning and testing on full load complete all as specified and directed.
All as per item No. 17.00 but here-in-before capacity 5 HP
All as per item No. 17.00 but here-in-before capacity 1/2/3 HP single phase
Repair/ Replacement of the following parts for air blowers Model M-5075, Capacity 160 Cum/ Hrs at STP MAP Ph-I:- (a) Change of gear oil upto the required level - 02 Job (b) Change of fan belt for air blower - 02 Nos (c) Change of air filter - 02 Nos
S&F DOL panel starter for submersible pump capacity 5 HP, 415V over load relay 3.8 to 6 amps contactor rating 16 Amps including taking out old starter, connecting, commissioning complete all as specified and directed. Make: Havells/ Standard/ BCH/ L&T.
M&L for repair to non clog pump centrifugal pump coupled with electric motor 15 HP capacity of sewage non clog pump set 3 phase, 440 volt 50 Hz after disconnecting electrically, mechanically and transporting to contractor workshop and re-fixing, reconnecting and testing the same after repair of following :- (a) Replacement of ball bearing as per existing make and size - 02 Nos (b) Repair to pump shaft after re-metalling, turning, polishing, adjustment and alignment 01 Job (c) Replacement of old worn out nuts & bolts - 01 Set (d) Replacement of rubber coupling - 01 No (e) Replacement of gland bush and packing - 01 No (f) Cutting to impeller key way and fixing of lock nut - 01 No (g) Repair to CI impeller - 01 job.
S&F in replacement submersible cable 6 Sqmm 3 core multi standard copper conductor cable round type all as specified and directed. Make : BCH/ Finolex/ Havells/ Polycab/ RR.
S&F in replacement submersible cable 4 Sqmm 3 core multi standard copper conductor cable round type all as specified and directed. Make : BCH/ Finolex/ Havells/ Polycab/ RR.
S&F battery 12V of capacity 180 AH maint free type complete all as specified and directed. Make : Express or equivalent in TATA/ AMARON.
Notes for Srl Item No. 1.00 to 8.00 :- (a) The contractor shall be responsible for uprooting the grass, shrubs, vegetation except the tree and cleaning the maintaining the STP area/ Sewage pump installations area with bush cutter machine upto the fencing or boundary wall. (b) If any operator/ helper (MTS) are found absent from duty recovery of Rs. 500/- per shift in addition to his wages as per CA shall be made from contractor's dues. (c) The contractor shall be responsible for treated water sample test as per CA provision but if test not found satisfactory, recovery for each fail test of Rs. 15000/- will be recovered from contractor's dues and after rectification contractor shall be responsible to carry out the re-testing of the sample within week and produce the test report of satisfactory results. Nothing extra shall be paid to the contractor for the re-testing or what so ever may be the expenditure on this account. (d) The area of STP and DG Set installation upto the fencing or boundary wall will be kept clean by contractor within the quoted rate of operation of each installation otherwise recovery of Rs. 1500/- per day will be recovered from contractor RAR or final bill. (e) Chlorination of treatment water shall be tested daily and record maintained by the contractor. However, if chlorine is not found in water at any check, recovery of Rs. 500/- per check will be imposed upon the contractor.
(f) Material required for packing the samples for testing and testing equipments required at site shall be provided by the contractor without any extra cost to the department. (g) All the machinery, panels, motors shall be got repaired by the contractor as per contract provisions. However, for all petty repair such as replacement of gland packings, tightening or replacement of worn out nuts, bolts, greasing the machinery, re-tightening all electrical connection, re-jointing of burnt electrical thimbles and replacement of wire etc adjustment of relays or de-carbonizing and cleaning of contacts of contactors, repair to stucked sluice valves, reflux valves repair to stucked pumps by cleaning of impeller housings including raking out and taking down etc shall be responsibility of contractor cost in this account shall deemed to be included in the overall cost quoted by the contractor for operation. Nothing shall be paid extra on this account. (h) contractor shall responsible for un-interrupted working of plant and machinery. If any problem occurs in machinery, the contractor will get the same checked from mechanic or electrician and details of fault will b submitted to deptt if not covered in their scope within 2 hours and standby machinery shall be made operative during repair. If any machinery found unserviceable at installation and intimation is not rendered to the deptt, recovery @ Rs. 500/- per machine per hour shall be imposed upon the contractor.
(j) In case, any machinery become faulty due to negligence of operating staff, recovery equal to double the cost of actual repairs shall be imposed upon the contractor. (k) Contractor will be responsible for cleaning and taking out all floating material such as polythene, papers, vegetations and other waste material from inside of sump well of including taking out raw sewage pumps as when required with the help of tripod and chain pulley block of suitable size after disconnecting electrically and mechanically from raw sewage collection sump having including opening the pump, cleaning all material accumulated in pump housing and impeller such as polythene, vegetation etc, including greasing of all bearings, tightening of impeller nuts, check nuts and other nut bolts, checking electric connection, re-lowering, re-fixing and re-connecting all pipes, making electric connections commissioning and testing of the same on load including removal of all waste material from installation and depositing as specified area at a distance n.exc 3.0 Km cost on this account whatsoever shall deemed to be included in the overall rate quoted by the contractor for operation and nothing extra shall be paid on this account. (l) All T&P and safety equipment shall be arranged by the contractor within the overall quoted rate for operation and nothing extra shall be paid on this account. (m) Standby pump will run whenever cleaning or any type of maintenance is required to be carried out.
SUNRISE ENGINEERS AND CONTRACTOR
CHOUDHARY AND SONS
R K ENTERPRISES
diamond electrical
P.K.MALL ENTERIPRSES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .