Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.9 LAccepted-AOC 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | 1 | Accepted-AOC accept | |
| 2 | 2₹23.7 L+₹1.7 L (7.73%)Rejected-AOC 00 RL QR NO 388 B KALIBARI COLONY ALIPURDUAR JN JALPAIGURI WEST BENGAL 736123 | ALIPURDUAR | WEST BENGAL | 736123 | 2 | Rejected-AOC reject | |
| 3 | 3₹32.0 L+₹10.0 L (45.5%)Rejected-AOC 00 INFRONT OF S R K PG COLLEGE KOTLA ROAD OM MARKET FIROZABAD UTTAR PRADESH 283203 | FIROZABAD | UTTAR PRADESH | 283203 | 3 | Rejected-AOC reject |
Tender Value
₹22 L
EMD Value
₹22,000
Closing Date
14 Nov 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EWC
Bareilly
System strenthening work at differrent 33/11 kv sub-stations under edc, Shahjahanpur
2023_MVVNL_860215_1
26/EWC(B)/2023-24
Open Tender
Electrical Works
Item Rate
90 days
Shahjahanpur
as per tender document
3 documents required · 3 mandatory
₹3,540
SE EWC
₹22,000
5 Mar 2025
7 Nov 2023
14 Nov 2023
7 Nov 2023
14 Nov 2023
7 Nov 2023
Amount
PART (A) WORK SPECIFICATION FOR SYSTEM STRENGTHENING WORK AT 33/11 V SUB-STAION JAMAUR,IN EDD I SPN, SHAHJAHANPUR
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
33 KV Lightening Arrestor
33 KV Line Isolator
33 KV 400 A Bus Isolator
33 KV VCB 800A 750 MVA
33 kv O/D CT CTR 200/100/1
33 KV CONTROL PANNAL FOR SINGLE LINE FEEDER
33 KV FUSE SET
33 KV CONTROL PANNAL FOR DOUBLE TF
DC supply system with 1 no float cum boost charger and 1 no battery set for 24V DC supply system with 200AH battery capacity with cabinet
Earthing of indoor & outdoor equipments of Sub-Station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per RESPO approved drawing & resistance of earthing should be not more than 2Ω as per details given below.
Making of triangular bridge by using MS electrode, GI strip 50x6mm and GI Pipe 40 mm dia with providing of well type pipe earthing upto 15 Mtr. depth below ground level including welding etc. by boaring process at T/F neutral, LA and newly erected structure including cost of GI pipe of size 40 mm dia 15 mtr. long of ISI mark.(all the required material will be supllied by the contractor).
Supply of GI strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. All LA will be seprately earth also as per RESPO norms. (All the required materials will be provided by firm.)
Installation of followig equipments on their respective structures including mechanical & electrical fixing after proper adjustment on their structure.
33 KV Bus Isolator
33 KV Line Isolator
33 kv O/D CT CTR 200/100/1
Lightening Arrestor
33 KV VCB 800A 750 MVA
33 KV FUSE SET
Dismentaling of existing following damage equipments on their structure.
33 KV Bus Isolator
33 KV Line Isolator
33 kv O/D CT CTR 200/100/1
33 KV VCB 800A 750 MVA
33 KV FUSE SET
33 KV Lightening Arrestor
33 KV CONTROL PANNAL FOR DOUBLE TF
Complete laying and termination of copper control cables from 10 MVA/5 MVA power T/F, 33 KV VCB, 33 KV CT in the out door switch yard to the existing transformer relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per RESSPO drawings, including cost of testing of transformer, VCB, CT, relay pannel & proper relay settings as per requirement etc.
Control Cable 4x2.5 mm2
Control Cable 2x2.5 mm2
Erection & testing of double T/F Control penel in substation control room including grouting of anchor bolts of panel and making of pocket for control cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Erection & testing of Single Line feeder Control penel in substation control room including grouting of anchor bolts of panel and making of pocket for control cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Repairing of existing 33KV VCB in switchyard including repalcement of all required accessories as relay,motor, intrruptor etc. All type of material should be provided by the firm.
Carriage of old scrap/dismentaling material from site to store center Shahjahanpur
Repairnig of swichyard fencing complete in all respect, including cost of welding painting etc.
PART(B) WORK SPECIFICATION FOR SYSTEM STRENGTHENING WORK AT 33/11 KV SUB-STAION ATSALIYA,IN EDD I SPN, SHAHJAHANPUR
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
33 KV Lightening Arrestor
33 KV Line Isolator
33 KV 400 A Bus Isolator
33 KV VCB 800A 750 MVA
33 kv O/D CT CTR 200/100/1
33 KV FUSE SET
33 KV CONTROL PANNAL FOR DOUBLE TF
DC supply system with one no float cum boost charger and 1 no battery set for 24v dc supply system with 200AH battery capacity with cabinet
Earthing of indoor & outdoor equipments of Sub-Station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per RESPO approved drawing & resistance of earthing should be not more than 2Ω as per details given below.
Making of triangular bridge by using MS electrode, GI strip 50x6mm and GI Pipe 40 mm dia with providing of well type pipe earthing upto 15 Mtr. depth below ground level including welding etc. by boaring process at T/F neutral, LA and newly erected structure including cost of GI pipe of size 40 mm dia 15 mtr. long of ISI mark.(all the required material will be supllied by the contractor).
Supply of GI strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. All LA will be seprately earth also as per RESPO norms. (All the required materials will be provided by firm.)
Installation of followig equipments on their respective structures including mechanical & electrical fixing after proper adjustment on their structure.
33 KV Bus Isolator
33 KV Line Isolator
33 kv O/D CT CTR 200/100/1
Lightening Arrestor
33 KV VCB 800A 750 MVA
33 KV FUSE SET
Dismentaling of existing following damage equipments on their structure.
33 KV Bus Isolator
33 KV Line Isolator
33 kv O/D CT CTR 200/100/1
33 KV VCB 800A 750 MVA
33 KV FUSE SET
33 KV Lightening Arrestor
33 KV CONTROL PANNAL FOR DOUBLE TF
Complete laying and termination of copper control cables from 10 MVA/5 MVA power T/F, 33 KV VCB, 33 KV CT in the out door switch yard to the existing transformer relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per RESSPO drawings, including cost of testing of transformer, VCB, CT, relay pannel & proper relay settings as per requirement etc.
Control Cable 4x2.5 mm2
Control Cable 2x2.5 mm2
Erection & testing of double T/F Control penel in substation control room including grouting of anchor bolts of panel and making of pocket for control cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Repairing of existing 33KV VCB in switchyard including repalcement of all required accessories as relay, motor, intrruptor etc. All type of material should be provided by the firm.
Carriage of old scrap/dismentaling material from site to store center Shahjahanpur
Repairnig of swichyard fencing complete in all respect, including cost of welding painting etc.
PART (C) WORK SPECIFICATION FOR SYSTEM STRENGTHENING WORK AT 33/11 V SUB-STAION NIGOHI,IN EDD I SPN, SHAHJAHANPUR
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
33 KV Lightening Arrestor
33 KV Line Isolator
33 KV 400 A Bus Isolator
33 KV VCB 800A 750 MVA
33 kv O/D CT CTR 200/100/1
33 KV FUSE SET
33 KV CONTROL PANNAL FOR DOUBLE TF
33 KV CONTROL PANNAL FOR SINGLE TF
33 kv PT 33KV/110V
11 KV Cable 3x300 sq mm xlpe
11 KV Cable jointing Kit 3x300 mm2 I/D
11 KV Cable jointing Kit 3x300 mm2 O/D
DC supply system with one no float cum boost charger and 1 no battery set for 24v dc supply system with 200AH battery capacity with cabinet
Earthing of indoor & outdoor equipments of Sub-Station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per RESPO approved drawing & resistance of earthing should be not more than 2Ω as per details given below.
Making of triangular bridge by using MS electrode, GI strip 50x6mm and GI Pipe 40 mm dia with providing of well type pipe earthing upto 15 Mtr. depth below ground level including welding etc. by boaring process at T/F neutral, LA and newly erected structure including cost of GI pipe of size 40 mm dia 15 mtr. long of ISI mark.(all the required material will be supllied by the contractor).
Supply of GI strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. All LA will be seprately earth also as per RESPO norms. (All the required materials will be provided by firm.)
Installation of followig equipments on their respective structures including mechanical & electrical fixing after proper adjustment on their structure.
33 KV Bus Isolator
33 KV Line Isolator
33 kv O/D CT CTR 200/100/1
Lightening Arrestor
33 KV VCB 800A 750 MVA
33 KV FUSE SET
33 kv PT 33KV/110V
Dismentaling of existing following damage equipments on their structure.
33 KV Bus Isolator
33 KV Line Isolator
33 kv O/D CT CTR 200/100/1
33 KV VCB 800A 750 MVA
33 KV FUSE SET
33 KV Lightening Arrestor
33 KV CONTROL PANNAL FOR SINGLE/ DOUBLE TF
33 kv PT 33KV/110V
Complete laying and termination of copper control cables from 10 MVA/5 MVA power T/F, 33 KV VCB, 33 KV CT in the out door switch yard to the existing transformer relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per RESSPO drawings, including cost of testing of transformer, VCB, CT, relay pannel & proper relay settings as per requirement etc.
Control Cable 4x2.5 mm2
Control Cable 2x2.5 mm2
Erection & testing of double T/F Control penel in substation control room including grouting of anchor bolts of panel and making of pocket for control cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Erection & testing of single T/F Control penel in substation control room including grouting of anchor bolts of panel and making of pocket for control cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Repairing of existing 33KV VCB in switchyard including repalcement of all required accessories as relay, motor, intrruptor etc. All type of material should be provided by the firm.
Laying of single circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m including fixing of cable route marker with difference of 50 mtr. at time of cable laying with complete engraved details of 33 KV Line and depth of 33 KV cable. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts.
Fixing of 33 KV O/D Cable Jointing Kit
Fixing of 33 KV I/D Cable Jointing Kit
Carriage of old scrap/dismentaling material from site to store center Shahjahanpur
Repairnig of swichyard fencing complete in all respect, including cost of welding painting etc.
PART (D)WORK SPECIFICATION FOR POWER TRANSFORMER PLINTH WORK AT 33/11 KV S/S JAMAUR EDD I SPN CAPACITY 10+8 MVA IN DISTRICT SHAHAJAHANPUR
Construction of augmentation and repairing of existing transformer plinth of size 4.5x3.5 Mtr. for upto 10 MVA Transfomer having depth 0.5 Mtr. below ground level & 0.5 Mtr. above ground level. Existing plinth is in very damage condition and its height is below ground level. The work including excavation of foundation. base & concreting of foundation base of CC 1:6:12 ratio (cement, fine sand & brick ballast) first class brick work of cement morter of ratio 1:4 for masonry & lintring work of transformer plinth of RCC work of ratio 1:2:4 (cement, coarse sand and store grit of 20mm using MS Bars of 10mm dia(tor) for reinforcement of linter including cutting, bending & binding of MS bars of required plinth size & shape. The work also includes laying of 2 Nos. 3.5 Mts. long rail pieces after cutting in proper size & shape & fitting etc. The plinth will be made as per RESSPO/Approved drawing suitable for 10 MVA transformer & shall be plastered of walls of ratio 1:4 (cement & fine sand)/finished on top and sides of the plinth. (all material will be provided by firm).
Shifting and dragging of 33/11 KV 5/10 MVA transformer from plinth side to safe side at substation alongwith its dismentling of all assessories and draining of T/F oil.
Shifting and dragging of 33/11 KV 5/10 MVA transformer from road side to its plinth alongwith its erection including fixing of all assessories and top-up of T/F oil.
PART (E) WORK SPECIFICATION FOR POWER TRANSFORMER PLINTH WORK AT 33/11 KV S/S NIGOHI EDD I SPN CAPACITY 2X10+5 MVA IN DISTRICT SHAHAJAHANPUR
Construction of augmentation and repairing of existing transformer plinth of size 4.5x3.5 Mtr. for upto 10 MVA Transfomer having depth 0.5 Mtr. below ground level & 0.5 Mtr. above ground level. Existing plinth is in very damage condition and its height is below ground level. The work including excavation of foundation. base & concreting of foundation base of CC 1:6:12 ratio (cement, fine sand & brick ballast) first class brick work of cement morter of ratio 1:4 for masonry & lintring work of transformer plinth of RCC work of ratio 1:2:4 (cement, coarse sand and store grit of 20mm using MS Bars of 10mm dia(tor) for reinforcement of linter including cutting, bending & binding of MS bars of required plinth size & shape. The work also includes laying of 2 Nos. 3.5 Mts. long rail pieces after cutting in proper size & shape & fitting etc. The plinth will be made as per RESSPO/Approved drawing suitable for 10 MVA transformer & shall be plastered of walls of ratio 1:4 (cement & fine sand)/finished on top and sides of the plinth. (all material will be provided by firm).
Shifting and dragging of 33/11 KV 5/10 MVA transformer from plinth side to safe side at substation alongwith its dismentling of all assessories and draining of T/F oil.
Shifting and dragging of 33/11 KV 5/10 MVA transformer from road side to its plinth alongwith its erection including fixing of all assessories and top-up of T/F oil.
SHIV TRADERS
SHREE KRISHNA TRADING CO
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .