| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.7 L+₹92,240 (4.66%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹21.2 L+₹1.4 L (6.96%)Rejected-Finance RC MINTRI ROAD KALIMPONG 734301 WB | KALIMPONG | KALIMPONG | WEST BENGAL | 734301 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹21.5 L+₹1.7 L (8.50%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹23.3 L+₹3.5 L (17.8%)Rejected-Finance | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
14 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
REPAIRS/REPLACEMENT OF LT DISTRIBUTION SYSTEM AND ALLIED WORKS AT PEDONG, ALGARAH, DALAPCHAND, AP ALGARAH AND TEESTA TCP UNDER GE 867 EWS
2020_MES_383350_2
CA NO GE / 867 / TOKEN / 46 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Pedong
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹36,000
Yes
5 Jan 2021
24 Nov 2020
15 Dec 2020
24 Nov 2020
14 Dec 2020
1 Dec 2020
24 Nov 2020 - 30 Nov 2020
60 days
Amount
Supplying & erecting of steel tubular swaged pole conforming to IS, specification complete with MS base plate, finial taper plug, bolts, nuts, type 410 SP-31, 9.00 mtr long and painted internally two coats of bituminous paint through out and externally upto planting depth and painting external exposed surfaces with two coats of alluminium paint over one coat of redoxide primer including provision of black and yellow paint strips of 05 Nos of 30 cm wide strips or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of poles with writing letters or figures ( Block ), height minimum 10 cm & letters or figures n'exc 10 Nos for electric LT/HT/SL including clamp including taking up existing pole complete all as specified and directed by Engineer-in-Charge.
Taking out existing steel tubular swaged poles of any length including cross arms and shifing upto 2 Km and erecting truly in vertical position complete all as specified and directed by Engineer-in-Charge. Note for Item No. 1&2:Earth work, excavation, PCC foundation, PCC coping shall be measured and paid seperately.
Supply and stringing of aluminium conductor steel reinforced (ACSR) of any size as in overhead lines including binding wires of suitable sizes and suitable conductors / parallel groove clamp Etc. other jointing materials for over head lines including taking down existing ACSR conductors complete all as specified and directed by Engineer-in-Charge.
Taking down existing ACSR conductors and refixing in same location or in new location and stringing of aluminium conductor steel reinforced (ACSR) of any size as in overhead lines including binding wires of suitable sizes and suitable conductors / parallel groove clamp Etc. other jointing materials for over head lines including complete all as specified and directed by Engineer-in-Charge.
M&L for cross arms , bracings, supports, clamps and back plate fabricated from structural sections including nuts, bolts, and washer bending hot or cold , drilling holes for bolts of any size and painting with two coats of aluminum paint over one coat of red oxide primer including preparation of surfaces, including taking down existing cross arms etc., complete all as specified and directed by the Enginee-in-Charge.
Taking down existing cross arms , bracings, supports, clamps and back plate fabricated from structural sections including nuts, bolts, and washer and refixing in same location or in new location and painting with one coat of aluminum paint including preparation of surfaces, complete all as specified and directed by the Enginee-in-Charge.
S & F pin type insulator, porcelain, vitreous white/ brown or green including one galvanised mild steel spindle two GI washer and one GI nut 100mm height, 65mm dia for 1100 Volt grade including taking down existing insulator complete all as specified and directed by Engineer-in-Charge.
S & F Schakle type insulator, porcelain, vitreous white/ brown or green including galvanised mild steel straps of size 31 x 5 mm, washers insulator bolt of 14 mm dia and nuts complete of size 100 mm hight and 115mm dia of working pressure 1100 volts grade including taking down existing insulator complete all as specified and directed by Engineer-in-Charge. Make for iItem No. 7 & 8: (i) Jaipuria (ii) Jayshree (iii) Maysore Electric Industries (iv) Oblum
Taking down existing Pin/Shakle type insulator and refixing in same location or in new location complete all as specified and directed by Engineer-in-Charge.
M&L for galvanised steel wire 3.15 or 4mm dia as earth continuity conductor including binding and connecting to earth test point etc., including taking down existing earth wire complete all as specified and directed by Engineer-in-Charge.
M&L for galvanised steel wire 3.15 or 4mm dia as in cradles, hexogonal/rectangular including binding and connecting to earth etc., including taking down existing cradles complete all as specified and directed by Engineer-in-Charge.
Taking down existing galvanised steel wire cradles, hexogonal/rectangular and refixing in same location or in new location including binding and connecting to earth etc., complete all as specified and directed by Engineer-in-Charge.
M&L for Stay assembly with 16mm dia rod complete with accessories as shown in electrical plate No. 1 including taking out existing stay assembly, insulator complete all as specified and directed by the Enginee-in-Charge. Note: Loop type insulator, stay clamps, stay wire, excavation and concrete shall be measured and paid separately.
S & F loop type insulator, porcelain, vitreous white/ brown or green of size 90 x 65mm with clearence of hole 16 mm including taking down existing insulator complete all as specified and directed by Engineer-in-Charge.
M&L for galvanised stay strand 7/4mm as stay wire including binding etc., including taking down existing stay wire complete all as specified and directed by Engineer-in-Charge.
Restringing of existing LT overhead line for removing exessive sag including removing the existing binding wire and rebinding with new binding wire after tightning of overhead lines including disconnecting existing jumper and connections and reconnecting after tightning of conductor incl replacement of all jumpers all as directed by Engr -incharge. Notes: - (a) Single wire run of conductor in LT lines shall be measured as one lenght for payment purpose. (b) ACSR conductor shall be measured and paid separately.
Restringing of existing earth continuity conductor for removing exessive sag including removing the existing binding wire and rebinding with new binding wire after tightning complete all as directed by Engr -incharge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note for Item No. 18 to 22:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Taking up exising LT cable of size 35 sqmm 3.5 core complete and relaying in trenches, fixed to wall or drawn through pipe etc., in same location or in new location and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge.
Taking up exising LT cable of size 50 to 95 sqmm 3.5 core complete and relaying in trenches, fixed to wall or drawn through pipe etc., in same location or in new location and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge. Note for Item No. 23&24:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately.
Material and labour for 40 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge.
Material and labour for 50 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge.
Material and labour for 80 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge.
Material and labour for 100 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge. Make for iItem No. 25 to 28: TATA/ZENITH/JINDAL
Material and labour for taking down/out existing 40 mm dia bore GI tubing Light grade, and relaying in same location or new location under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection complete all as specified and directed by Egineer-in-Charge.
Material and labour for taking down/out existing 50 mm dia bore GI tubing Light grade, and relaying in same location or new location under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection complete all as specified and directed by Egineer-in-Charge.
Material and labour for taking down/out existing 80 mm dia bore GI tubing Light grade, and relaying in same location or new location under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection complete all as specified and directed by Egineer-in-Charge.
Material and labour for taking down/out existing 100 mm dia bore GI tubing Light grade, and relaying in same location or new location under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection complete all as specified and directed by Egineer-in-Charge.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5 in depth for taking out /laying of cable etc., and getting out in soft/loose soil.complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5 m and not exceeding 3 m in depth for taking out /laying of cable etc., and getting out in soft/loose soil.complete all as specified and directed by Engineer-in-Charge.
Returning, filling in soil, including spreading leveling, watering and wall ramming in laying not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exe 50m and depositing where directed at alevel n.exe 1.5m above the starting point complete all as directed by Engineer - in -Charge.
M&L for Plain cement concrete 1:3:6 mix type C2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete etc., all as specified and directed by Engineer-in-Charge.
M & L Plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping including necessary formwork, weathering, slightly rounded or chamfered andgles, finishing of exposed surfaces of concrete to even and smooth without using extra cement all as specified and directed by Engr-in-charge.
M&L for Plain cement concrete 1:2:4 mix type B2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete etc., repair to plinth, foot path, panel foundation etc., at Power house and sub stn including necessary form work coplete all as specified and directed by Engineer-in-Charge.
M&L for common burnt bricks, sub class 'B', of size 250 x 125 x 75 mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Taking out existing common burnt bricks, and relaying in same location or in new location for cable protection complete all as specified and directed by Engineer-in-charge.
Supply and spreading of dry sand in trenches for cable coushioning and punned down complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.
S& F in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as directed by Engr-in-charge.
S&F factory made, powder coated, indoor type switch disconnector fuse ( panel mounting cubical type) bus bar chamber, made out of 2mm thick MS sheet suitable for housing and including Three pole and neutral AC -23 A, 50 HZ, 415 Volts and 3 Nos HRC fuse rating 200 Amps mounted on insulators with cable gland to top & bottom for cables suitable for surface mounting type with openable door and locking arragement including taking down existing bus bar chamber complete all as specified and as directed by Engr-in-charge. Make: Havells cat Part No for Panel IHFKTW4200 and for HBC fuse IHHCD01200 or equivalent of Schnider/Hager
S&F of MCCB of Four Pole, 415V, AC 50 Hz, 36KA breaking capacity 200 Amps Ics=100%Icu with overload and thermal release range 70 to 100% and magnetic setting adjustable features including taking down old unserviceable MCCB complete all as specified and directed by Engineer-in-Charge.
S&F of MCCB of Four Pole, 415V, AC 50 Hz, 36KA breaking capacity 160 Amps Ics=100%Icu with overload and thermal release range 70 to 100% and magnetic setting adjustable features including taking down old unserviceable MCCB complete all as specified and directed by Engineer-in-Charge.
S&F of MCCB of Four Pole, 415V, AC 50 Hz, 36KA breaking capacity 125 Amps Ics=100%Icu with overload and thermal release range 70 to 100% and magnetic setting adjustable features including taking down old unserviceable MCCB complete all as specified and directed by Engineer-in-Charge. Make for Item No. 45 to 47: LEGRAND/SIEMENS/SCHNEIDER/L&T
Earhing complete with galvanized steel earth plate electrode 600X600X6 mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to GI earth strip of size 32x6mm, by means of galvanized iron or steel bolts, nuts, check nuts and washers, and conneced to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh charcoal or coke and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and suitable handle of 10 mm dia round bar, 40 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, 15 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
Supply & Fixing LED street Light in aluminum PDC housing toughened glass cover with IP 66 protection of 80 Watt to existing system by providing suitable length of three core 1.5 sqmm PVC insulated copper conductor cable including taking down old unserviceable street light fittings of any type, complete all as specified and as directed Make: - SURYA cat part No. SLE UL 80W IP66 LXN or equivalent make of Philips /CG approved by GE.
Supply & Fixing LED street Light in aluminum PDC housing toughened glass cover with IP 66 protection of 20 Watt to existing system suitable for solar battery 12 Volt DC including providing suitable length of three core 1.5 sqmm PVC insulated copper conductor cable including taking down old unserviceable street light fittings of any type, complete all as specified and as directed Make: - SURYA cat part No. SLE UL 20W IP66 LXN or equivalent make of Philips /CG approved by GE.
M & L topping up distill water of adequate qty in battery of existing Standalone solar street light complete all as specified and directed by Engineer-in-Charge.
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 41,795.00 B/F from Ser page No. 29 NOTE: Bidder shall insert credit amount as rate Rs. 41,795.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
SUNIL PRADHAN
C. M. AGARWAL AND CO
PRASAD PRADHAN AND SON
SANJAY MITTAL
MS BRAHMA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .