Executive Engineer Electrical
Executive Engineer Electrical SKIMS Soura
SITC of Fans, Geysers and Safety Devices in Ground and First floor of Psychiatry block at SKIMS MCH Bemina
2021_SKIMS_139354_1
eNIT NO.SIMS/HEE/E/ET/14 of 2021-22 Dt. 13-09-2021
Open Tender
Electrical Works
Item Rate
30 days
SKIMS MCH Bemina
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
CAO SKIMS MCH Bemina
₹5,900
Yes
20 Dec 2021
14 Sept 2021
2 Nov 2021
14 Sept 2021
29 Oct 2021
14 Sept 2021
270 days
Amount
Supply, Installation, Testing and Commissioning of Cieling Fan 1200 mm sweep, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, controlled by electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Providing and fixing of Fan hooks of suitable size complete as required.
provinding and fixing of Fan regulater stepped type one way complete as required
P/installation of Exhaust fans 250 mm plastic Shutter type (ISI marked).
Providing fixing of ply board 12 mm thick suitable size for above mentioned exhaust fans 12" with central hole and screws etc. complete with civil work.
Providing and fixing of Switch socket Combine 15/16 A for above item no 3.
P/f of bakelite /Phenolic Laminated Sheet 3 mm thick for fixing of S.S comb.15/16 A socket outlet and inspection boxes/computer system..
Supply ,Installation testing & commissioning of fresh Geyser 50 liters along with foundation bolts, top,lead and pvc connection.
Supply ,Installation testing & commissioning of fresh Geyser 35 liters along with foundation bolts, top,lead and pvc connection.
Supplying and fixing TPN 8 way, single pole and neutral, sheetsteel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper insulated bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required.in wards and rooms .
Supplying and fixing following rating, 240/415 volts, “C”curve,10KA miniature circuit breaker suitable for inductive load the MCB DB should be complete with connections, testing and commissioning etc. as required.
a) P/F of MCB TPN 63A lighting and heating points in Sub D.B normal power
b) P/F of MCB SP 10A to 16A for lighting and heating points in above D.B and industrial sockets.
c) P/F of RCCBs 63A/ 300 MA 240/415 volts to be fixed in above mentioned DB's. For heating circuits
Providing and fixing 100amps with 25 KA breaking capacity Four pole MCCB including drilling holes in MCCB enclosure, making connections, etc. as required..
a) Providing and fixing sheet steel MCCB enclosure suitable for 100 amps,25 KA breaking capacity Four pole MCCB complete with lockable door, dust/vermin proof, hinged type, cable entry houles and power coated painted.
P/f of TPN Bus bar 100 A 4way wall mounted (industrial switch gear busbar chamber)
Providing & Laying of 95 mm Sq. 3.5 core XLPE /PVC insulated Al. Cable Armoured (ISI marked) from Main DB psychiatric block to Grounfd floor psychiatric block .
Providing & laying of 1x 16mm Sq. copper wire For light points sub main 2 ckts of 1x16 mm sq.
Providing and making of End Termination of the 95 mm Sq. 3.5 core LT cable including thimbling ,crimping, tapping ,testing & connecting at Site.
Same as above item but for 16 sq. mm copper wire
Fixing of above cable 95 mm sq. mm 3.5 core on wall clamped with 25x3 mm MS flat clamps
P/Laying of 25 mmx 5 mm G.I earthing strips including nut ,bolts from existing earth point upto DB as per site requirement
M/S BHAT SYNDICATE
ASIAN TRADING COMPANY
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .