Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹1.7 L
EMD Value
₹1,690
Closing Date
13 Jul 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC-II ALIGARH
ALIGARH
Various works under business plan against sanctioned packages in the jurisdiction of EDC-II, Aligarh.
2020_DVVNL_486929_2
EDC2A-21/2020-21
Open Tender
Electrical Works
Item Rate
30 days
ALIGARH
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
DVVNL AGRA WEBSITE
₹1,690
8 Aug 2020
8 Jul 2020
13 Jul 2020
8 Jul 2020
13 Jul 2020
8 Jul 2020
30 days
Amount
Cartage of following PCC/ST poles Store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of dragging etc. and also including the cost of labour, T&P carrier etc. required for proper completion of work. (Dist. 0 to 50 Kms.).
PCC poles 8.5 Mtr./ 9 Mtr.
Cartage of line material viz Conductor/Cable, AB Cable, Transformer, GI earth wire, Cross Arm, Angle, Channel, Insulator, Clamps & other line material from Store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of dragging etc. and also including the cost of labour, T&P carrier etc. required for proper completion of work. (Dist. 0 to 50 Kms.).
Erection of single support including complete H.T/L.T fittings as per RESPO manual and as per direction of Engineer incharge including the cost of labour, T & P and carrier etc. required for proper completion of work.
PCC poles 8.5 Mtr./ 9 Mtr.
Erection of double pole on PCC pole/ST pole including the work of complete line as per RESPO norm manual and as per direction of Engineer Incharge including the cost of labour, T & P and carrier etc. required for proper completion of work.
PCC poles 8.5 Mtr/9 Mtr.
Laying, sagging, stringing, binding and jumpering etc. of new/old line conductor on the newly erected pole as per RESPO manual and as per direction of supervising engineer, including the cost of arrangement of labour, T&P carrier etc. required for proper completion of work.
ACSR Weasal Conductor
Safe carriage of LT cable of size 4x16/3.5X70/35/3.5/150/70 Sq.mm. from store to respective site of work including loading unloading at both ends.
Laying of 4x16/3.5X70/35/3.5/150/70 Sq.mm. LT Cable Jumphering from L.T. Site transformer to Line.
Replacement/Re-fixing of following damaged/ disturbed/de-aligned accessories:-
11 KV Disc Insulator
11 KV Pin Insulator
F-Bracket
Fixing of T-off Channel as per RESPO Norms.
Fixing of Top Channel as per RESPO Norms.
Fixing of Dropper Channel as per RESPO Norms.
Fixing of T/F Base Channel/Angle as per RESPO Norms.
Fixing of V- type cross arm as per RESPO Norms.
Fixing of Holding Clamp with bolt nut as per RESPO Norms.
Different type of insulators/clamps /connectors/ fittings.
Drilling and cutting of tee off channel, V cross arms, Top channel, cross bracing angle, MS garding angle, Dropper chanel. as per specification of UPPCL construction manual including including loading and unloading at the both ends.
Grouting of poles as per RESPO norms including cost of grouting material (cement: sand: brick ballast) size as per RESPO norms. This qty also includes the additional work of old & existing LT line which has to be converted into HT line. Presently the supports of old line do not have grouting.
PCC poles 8.5 Mtr.
Chopping of tree branches which are touching to 11 KV/LT lines.
Retighting of stay complete with nozelling & binding including cost of labour T&P etc required for proper completion of work.
Straightening of tilted PCC/ST poles at various places as per direction of JE.
Re-sagging of loose HT/LT line conductor as per direction of supervising engineer. It includes the cost of labour T&P carrier etc. required for proper completion of work.
ACSR Weasol Condutor
Guarding of 11 KV line by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 Mtr. as per RESPO manual and also including the cost of arragement of labour, T & P etc. required for proper completion of work.
Fixing of earthing rod as per RESPO manual and as per direction of supervising engineer including the cost of labour, T&P etc. Required for proper completion of work.
Erection and grouting of stay set including the work of nozzling etc. as per RESPO manual and also including the cost of arrangement of all grouting material, labour, T&P etc. required for proper completion of work.
Providing and fixing of stay insulator.
Demounting & carriage of following capacity transformer due to damage of PCC poles including the work of its loading & unloading, dragging etc. and also including the cost of labour and T&P etc. required for proper completion of work.
25 KVA T/F
63 KVA T/F
Carriage and installation of site to Store of following capacity transformer due to damage of PCC poles including the work of its loading & unloading, dragging etc. and also including the cost of labour and T&P etc. required for proper completion of work.
25 KVA T/F
63 KVA T/F
100 KVA T/F
Safe carriage of Old line material viz. Conductor, G.I. Earth wire, ABC conductor, Cross Arm, Angle, Channel, Insulators, Clamps & other line material from any other place or from site of work to store centre/ J.E. Store of its loading & unloading at the respective ends including the cost of labour, T&P and carrier etc. required for proper completion of work.
Safe carriage of new 11 KV VCBs from Store Center Aligarh to 33/11 KV S/S Sahajpura.
Dismentling of old 11 KV VCBs after opening its 11 KV cable with connection removing earthing, bus bar CTs and taking it out side control room.
Errection and Installation of 11 KV VCB including all labour out going incoming connection with bus bar 11 KV cable boxes tapping with empire tape & H.T. tape and connecting with earthing at 33/11 KV S/S Sahajpura.
Earthing of 11 KV VCBs providing & laying M.S. earth strip 50x6 mm including welding bending etc at 33/11 KV S/S Sahajpura.
Safe carriage of old 11 KV VCBs from 33/11 KV S/S Sahajpura to Store, Lal Diggi, Aligarh including loading & unloading at both ends.
SSK ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .