Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC 1ST FLOOR GURJEET MARKET DHANGU ROAD | ₹24.5 L Quoted ₹26.0 L | L1 | Accepted-AOC Lowest Bid |
| 2 | L2₹30.9 LRejected-Finance | ₹30.9 L | L2 | Rejected-Finance Other than lowest bid |
| 3 | L3₹32.8 LRejected-Finance | ₹32.8 L | L3 | Rejected-Finance Other than lowest bid |
| 4 | L4₹34.6 LRejected-Finance | ₹34.6 L | L4 | Rejected-Finance Other than lowest bid |
| 5 | L5₹35.4 LRejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹35.4 L | L5 | Rejected-Finance Other than lowest bid |
| Sl No | Description | Qty | Unit | RATTAN CHAND CHANDAN AND CO L6 | AGGARWAL ASSOCIATES L2 | KULBHUSHAN AGGARWAL L3 | JAI DURGA CONSTRUCTION CO L8 | kailu construction co L7 | Abrol construction co L9 | Vijay Kumar Contractor and Engineers L1 | SATISH AND CO L5 | M/s Swastik Engineers L10 | Standard engineers L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for overhauling & servicing of electrically operated hanger sliding steel door, each panel of approximate size 3.5 to 4.0 Metre in width and 10 Metre in height, by taking out mechanical parts and electrical connections & carry out repairs of motor, gear box assembly, electric control panel including replacement of unserviceable components/spares/ greasing etc. complete and re-assembling/reconnecting all the parts/portions including testing to ensure efficient and smooth functioning of door, both electrically & manually etc, complete all as specified and directed.
Notes :-
1. Parts shall be measured & paid for seperatly as supply only.
2. Cost of minor replacment of spares part of panels etc shall be included in qouted rate. | 2 | Each Job | 5,002 ₹10,004 | 4,800 ₹9,600 | 6,000 ₹12,000 | 5,050 ₹10,100 | 4,980 ₹9,960 | 5,075 ₹10,150 | 4,000 ₹8,000 | 5,100 ₹10,200 | 5,200 ₹10,400 | 5,000 ₹10,000 |
| 2.00 | Supply only gear of size 4" to 6" ( existing pattern / type and make) of gear assembly suitable for Electric motor for operating hanger door, complete all as specified and directed. | 1 | Each | 15,350 ₹15,350 | 13,500 ₹13,500 | 18,000 ₹18,000 | 15,400 ₹15,400 | 14,950 ₹14,950 | 15,075 ₹15,075 | 4,000 ₹4,000 | 15,100 ₹15,100 | 15,500 ₹15,500 | 15,000 ₹15,000 |
| 3.00 | Supply only gear box of existing make / pattern and type suitable for Electric motor for operating for hanger door, complete all as specified and directed. | 1 | Each | 7,550 ₹7,550 | 7,500 ₹7,500 | 8,000 ₹8,000 | 7,600 ₹7,600 | 7,548 ₹7,548 | 7,575 ₹7,575 | 4,000 ₹4,000 | 7,550 ₹7,550 | 8,000 ₹8,000 | 7,500 ₹7,500 |
| 4.00 | M & L for rewinding of electric motor 1.1 KW / 1.5 HP with super enamelled copper winding wire of same gauge & Nos of turns including impregnated paper, varnish and tape etc. including minor repairs and making the motor servicable, complete all as specified and directed. | 2 | Each | 3,150 ₹6,300 | 2,500 ₹5,000 | 2,500 ₹5,000 | 3,200 ₹6,400 | 3,148 ₹6,296 | 2,575 ₹5,150 | 2,000 ₹4,000 | 2,550 ₹5,100 | 3,000 ₹6,000 | 2,500 ₹5,000 |
| 5.00 | M & L for rewinding of 3 phase AC induction motor of Cap - 1.5 HP, S1 duty, IP-55, 415 v AC (+/-) 10 %, RPM- 1415, efficiency - 78 %. Including dismantling and taking down old defective damaged motor carefullly from the existing sliding hanger doors by provn of suitable safety measures,including minor repairs and making the motor servicable, complete all as specified and directed. | 2 | Each job | 5,000 ₹10,000 | 4,000 ₹8,000 | 4,000 ₹8,000 | 5,050 ₹10,100 | 4,980 ₹9,960 | 5,075 ₹10,150 | 2,000 ₹4,000 | 5,100 ₹10,200 | 5,500 ₹11,000 | 5,000 ₹10,000 |
| 6.00 | M & L for rewinding of 3 phase AC induction motor of Cap - 4-5 HP, S1 duty, IP-55, 415 v AC (+/-) 10 %, RPM- 1415, efficiency - 78 %. Including minor repair and making the motor servicable, dismantling and taking down old defective damaged motor carefullly from the existing sliding hanger doors by provn of suitable safety measures compete all as specified and directed. | 1 | Each Job | 5,000 ₹5,000 | 4,500 ₹4,500 | 4,500 ₹4,500 | 5,050 ₹5,050 | 4,980 ₹4,980 | 5,075 ₹5,075 | 3,500 ₹3,500 | 5,100 ₹5,100 | 5,500 ₹5,500 | 5,000 ₹5,000 |
| 7.00 | Supply, installation and testing of 200 Watt, optical design runway edge high intensity, yellow filter Bi-directional elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed. | 6 | Each | 21,950 ₹1.3 L | 18,000 ₹1.1 L | 21,500 ₹1.3 L | 22,000 ₹1.3 L | 21,048 ₹1.3 L | 22,075 ₹1.3 L | 7,000 ₹42,000 | 21,950 ₹1.3 L | 22,500 ₹1.4 L | 22,000 ₹1.3 L |
| 8.00 | Supply, installation and testing of 200 Watt, optical design runway edge high intensity, Clear filter Bi-directional elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed. | 4 | Each | 22,000 ₹88,000 | 18,000 ₹72,000 | 21,500 ₹86,000 | 22,050 ₹88,200 | 21,048 ₹84,192 | 22,075 ₹88,300 | 7,000 ₹28,000 | 21,950 ₹87,800 | 22,500 ₹90,000 | 22,000 ₹88,000 |
| 9.00 | Supply, installation and testing of 200 Watt, optical design runway edge high intensity, 180⁰ Green/Red filter Bi-directional elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed. | 3 | Each | 22,500 ₹67,500 | 18,000 ₹54,000 | 21,500 ₹64,500 | 22,550 ₹67,650 | 22,032 ₹66,096 | 22,075 ₹66,225 | 7,000 ₹21,000 | 22,050 ₹66,150 | 22,500 ₹67,500 | 22,000 ₹66,000 |
| 10.00 | Supply, installation and testing of 200 Watt, optical design runway edge high intensity, Uni-directional approch elevated halogen lamp light fitting with die cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/ description etc complete all as specified and directed. | 3 | Each | 22,500 ₹67,500 | 18,000 ₹54,000 | 15,000 ₹45,000 | 22,550 ₹67,650 | 22,032 ₹66,096 | 22,075 ₹66,225 | 7,000 ₹21,000 | 22,050 ₹66,150 | 22,500 ₹67,500 | 22,000 ₹66,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Sept 2025, 6:00 pmClosed
GE (S) Mamun
MEGE (South) Mamun, MES Complex, Mamun Cantt, Pathankot
As specified in BOQ and Tender Documents
2025_MES_728604_1
GE(S)/M-49/2025-26
Open Tender
Civil Works
270 days
GE (South) Mamun, MES Complex, Mamun Cantt, Pathan
As per NIT
10 documents required · 10 mandatory
₹500
Yes
GE (South) Mamun
₹60,000
Yes
31 Dec 2025
30 Aug 2025
29 Sept 2025
30 Aug 2025
21 Sept 2025
14 Sept 2025
Amount
M&L for overhauling & servicing of electrically operated hanger sliding steel door, each panel of approximate size 3.5 to 4.0 Metre in width and 10 Metre in height, by taking out mechanical parts and electrical connections & carry out repairs of motor, gear box assembly, electric control panel including replacement of unserviceable components/spares/ greasing etc. complete and re-assembling/reconnecting all the parts/portions including testing to ensure efficient and smooth functioning of door, both electrically & manually etc, complete all as specified and directed. Notes :- 1. Parts shall be measured & paid for seperatly as supply only. 2. Cost of minor replacment of spares part of panels etc shall be included in qouted rate.
Supply only gear of size 4" to 6" ( existing pattern / type and make) of gear assembly suitable for Electric motor for operating hanger door, complete all as specified and directed.
Supply only gear box of existing make / pattern and type suitable for Electric motor for operating for hanger door, complete all as specified and directed.
M & L for rewinding of electric motor 1.1 KW / 1.5 HP with super enamelled copper winding wire of same gauge & Nos of turns including impregnated paper, varnish and tape etc. including minor repairs and making the motor servicable, complete all as specified and directed.
M & L for rewinding of 3 phase AC induction motor of Cap - 1.5 HP, S1 duty, IP-55, 415 v AC (+/-) 10 %, RPM- 1415, efficiency - 78 %. Including dismantling and taking down old defective damaged motor carefullly from the existing sliding hanger doors by provn of suitable safety measures,including minor repairs and making the motor servicable, complete all as specified and directed.
M & L for rewinding of 3 phase AC induction motor of Cap - 4-5 HP, S1 duty, IP-55, 415 v AC (+/-) 10 %, RPM- 1415, efficiency - 78 %. Including minor repair and making the motor servicable, dismantling and taking down old defective damaged motor carefullly from the existing sliding hanger doors by provn of suitable safety measures compete all as specified and directed.
Supply, installation and testing of 200 Watt, optical design runway edge high intensity, yellow filter Bi-directional elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed.
Supply, installation and testing of 200 Watt, optical design runway edge high intensity, Clear filter Bi-directional elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed.
Supply, installation and testing of 200 Watt, optical design runway edge high intensity, 180⁰ Green/Red filter Bi-directional elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed.
Supply, installation and testing of 200 Watt, optical design runway edge high intensity, Uni-directional approch elevated halogen lamp light fitting with die cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/ description etc complete all as specified and directed.
Supply, installation and testing of 45 Watt, optical design, Omni directional taxi way edge elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondary lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed.
S&F in repairs 200 Watt 6.6 Amps bi-pin halogen lamp including taking out existing fused lamp of any type/description etc, complete all as specified and directed.
S&F in repairs 45 Watt 6.6 Amps bi-pin halogen lamp including taking out existing fused lamp of any type/description etc, complete all as specified and directed.
S&F in repairs lamp holder for halogen lamp suitable for 200/45 Watt runway/taxi light fitting including taking out existing unserviceable lamp holder of any type/description etc, complete all as specified and directed.
S&F in repairs base plate with breakable coupling suitable for 200/45 Watt runway/taxi light fitting including taking out existing unserviceable coupling of any type/description etc, complete all as specified and directed.
S&F in repairs mounting assembly suitable for 200/45 Watt runway/taxi light fitting including taking out existing unserviceable mounting assembly of any type/description etc, complete all as specified and directed.
S&F in repairs Lens filter of any type/colour suitable for 200 Watt halogen Uni/Bi directional optical design high intensity runway light fitting including taking out existing unserviceable lens filter of any type/description etc, complete all as specified and directed.
S&F in repairs Lens filter of any type/colour suitable for 45 Watt Omni directional taxi way edge elevated halogen lamp taxi light fitting including taking out existing unserviceable lens filter of any type/description etc, complete all as specified and directed.
Supply only printed circuit control Power card (thyristor type) suitable for 15 KW CCR panel to suit existing etc, complete all as specified and directed.
Supply only plug receptacle connector (ESSMA) suitable for 5KW, 6 sqmm copper conductor cable etc, complete all as specified and directed.
S&F in repairs multifunctional meter, 3 lines LCD display in 96x96 Sqmm flush mounted case Accuracy class 1.0 & 0.5, Panel mounted complete all as specified and directed.
S&F in repairs industrial panel socket of rating 16A -6h, 2P+Earth of cap 200-250 VAC complete all as specified and directed.
S&F in repairs industrial panel socket of rating 63A -6h, 3P+N+Earth of Cap 415 VAC complete all as specified and directed.
S&F in repairs MCB TPN of Cap 32 Amps C series complete all as specified and directed. Note:- Cutting chases in walls/floors/ceilings wherever required for electric work shall be deemed to be included in respective item of Schedule ‘A’.
Supply, fixing and testing of 200W LED highbay Light luminaire with tapered fin design and excellent thermal management along with IP-66 protection. LED highbay Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete available up to CCT 6500K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED highbay light shall be top cover maintainable for easy maintenance. LED highbay Light shall use multiple LEDs to get sufficient light output from the luminaire more than 20000 luman. The LED Flood Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver with SPD shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Light shall have power factor more than 0.95 complete all as specified and directed.
S&F in repairs, turbo ventilator stainless steel of 600 mm dia including top cover, vertical shaft wind blade, bearing, stand bar, bearing seal coat fibre sheet as per existing size/on site requirement including taking down old unservicable turbo ventilator complete all as specified and directed.
M&L for dismantling and taking out burnt winding by cutting, cleaning slouts of AC ceiling fan motor1200mm/1400mm of any make and re winding with super enameled heat resistant copper winding wire of existing gauge & nos of turns including, sleeve work, varnishing with E class insulation, greasing , threading, connection with flexible wire 0.472 mm copper wire upto connector block and re-assembling and testing for 4 Hrs after repair complete all as specified and directed Note:- (i) Fan shall be collected by the contractor from site at thier own arrangement. (i) Motor shall be wound with machine only and repair of fan shall be undertaken inside complex / office of GE (S) Mamun. (ii) Super enameled copper winding wire of make Khaitan/RPG/KEI or equivalent shall only be used. (iii) Rates are deemed to be include cost of repair / servicing & replacement of minor spare part i.e. blade screws, capacitors, clamps, terminal connection, split pin, spring washer etc.
All as per description of Srl item No. 31.00 here in before but for cabin fan/wall mounted fan alongwith connected accessories minor repair i.e. body repair, clips and blade complete all as spd and directed.
Supply only gun metal bush of ceiling fan complete all as specified and directed.
Supply only capacitor AC 415 volts 2.5 mfd oil filed ISI marked complete all as spd Make: L&T/Havells/Epcos.
All as per description of Srl item No. 34.00 here in before but 3.15mfd.
All as per description of Srl item No. 34.00 above but 4.5 mfd.
Supply only ball bearing of suitable size as per existing make and size of ceiling fan complete all as specified and directed. (bearing with 8 balls shall only be used).
Supply only ball bearing of suitable size as per existing make and size of exhaust fan/wall mounted Fan complete all as specified and directed. (bearing with 8 balls shall only be used)
Supply only shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed.
Supply only fan blades as per existing shape, colour and design suitable for 1200mm sweep ceiling fan of any make complete all as specified.
Supply only down rod of ceiling fan complete with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) complete all as specified and directed.
Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, checking defective / unservicable parts, cleaning, greasing/oiling of bush and bearings, replacement of defective set of split pins, cotter pins, blade screws, cup of both side with new one if required, and refixing to the existing site after servicing complete all as directed. (supply of replaced parts if any, other than catered for in item, shall be measured and paid seperately).
M&L for servicing of exhuast fans of capacity 380mm / 450mm including taking down from site, dismantling, checking defective un servicable parts, cleaning, greasing/oiling of bush and bearings, replacement of outer gasket and nut & Bolts incl cleaning of outer part & fixing wall and refixing to the existing site after servicing complete all as directed.(supply of replaced parts if anyother than catered for in item, shall be measured and paid seperately).
Supply and Fix PVC insulated and overall sheathed cable with flexible copper conductor 3 core of size 0.5 sqmm
All as per description of Srl item No. 45.00 here in before but 450mm sweep as per site requirement complete all as specified and directed. Note:- Total weight of binding wire shall not be less than 200gm per fan. The weight of old winding for credit shall also be taken as 200gm.
All as per description of Srl item No. 45.00 here in before but 500mm to 750mm sweep complete all as spd and directed. Note:- Total weight of binding wire shall not be less than 300gm per fan. The weight of old winding for credit shall also be taken as 300gm.
M&L for removing old paint from ceiling fan 1200-1400mm sweep by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to at workshop with heat resistant synthetic enamel paint by spray painting incl, writing MES No as directed. Note: Paint qaulity and colour shall be get approved from GE.
Supply only PVC canopy top & bottom of ceiling fan as per exisintg size & shape complete all as per specified and directed
Supply only metallic casing set (upper and lower) for housing ceiling fan motor of size required at site for ceiling fan 1200mm / 1400mm sweep made of cast iron, surface powder coated complete all as specified and directed
Supply and Fix in repairs shutter and louver of exhaust fan as per existing size & shape complete all as specified and directed.
Supply only MS fan blade of exhaust fan as per existing size & shape duly painted with synthetic enamel paint complete all as specified and directed.
Supply and replace existing unserviceable PVC fan blade of exhaust fan as per existing size & shape complete all as specified and directed.
M & L for lathe work incl re-alignment to rotor, stater sloter, cleaning welding, bracing and polishing etc and refixing after repair and testing complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, ceilling roses, holder, regulators, etc, removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be made as per conditions separately) and making good surfaces, wall, floors etc complete all as specified and directed.
M& L for Point wiring for one light point / fan point / bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed, FRLS, Multistranded copper conductor cable in and including non metalic rigid PVC concealed conduit ISI marked, not less than 20mm dia, medium duty with all necessary fittings Tee, elbow, socket including sunken steel boxes of suitable size with 3mm thick plastic laminated backelite sheet including FRLS PVC insulated unsheathed multistranded copper conductor cable of size 1.5sqmm (green colour) as continious earth wire and connecting to earth dolly, and making good to distrubed surfaces of wall/floor to match to existing finishes etc complete all as specified and directed. Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
All as per description of Sl item No 56.00 here in before but in existing PVC Conduit Pipe.
All as per description of Sl item No 56.00 here in before but in PVC Casing and capping with all the necessary fittings accessories such as tee, socket, elbow, junction box etc.
M& L for Point wiring for one light point etc controlled by 02 two ways switches with copper conductor cable FRLS multistrand of size 1.5 Sqmm(red or yellow or blue colour) PVC insulated and unsheathed with 1.5 Sqmm PVC insulated copper conductor cable as earth wire (green colour), in and including non metalic rigid PVC Conduit of medium duty not less than 20mm dia,and with sunk cast iron boxes for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover connecting to earth dolly and makes good surface all as specified. Note: The unit rate quoted include the cost of cutting chases in surfaces for conduits and fixing of sunken boxes and making good the distrubed surfaces to match the existing surfaces.
All as per description of Srl item No 59.00 here in before but in existing PVC Conduit Pipe
All as per description of Srl item No 59.00 here in before but in PVC Casing and capping with all the necessary fittings accessories such as tee, socket, elbow, junction box etc.
M& L for Point wiring for one socket outlet 5 Amp 3/5 pin for independent board etc controlled by one switch with copper conductor cable FRLS type multistrand of size 1.5 Sqmm(red or yellow or blue colour) PVC insulated and unsheathed with 1.5 Sqmm PVC insulated copper conductor cable as earth wire (green colour) connecting to earth dolly, in and including non metalic rigid PVC Conduit medium duty not less than 20mm dia,and with sunk cast iron boxes for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified.
All as per description of Srl item No 62 here in before but for one 3 pin 5 amps socket outlet independent board in existing Conduit.
All as per description of Srl item No 62 here in before but for one 3 pin 5 amps socket outlet independent board in PVC casing & caping with all the necessary fittings & accessaries tee, elbow, socket, junction box etc all as specified and directed.
All as per description of Srl item No 62 here in before but for one 3 pin 5 amps socket outlet on the same board with other switch.
All as per description of Srl item No 62 here in before but for one 3 pin 5 amps socket outlet on the same board with other switch in existing conduit.
All as per description of Srl item No 66 here in before but for one 3 pin 5 amps socket outlet on same board board in PVC casing & caping with all the necessary fittings & accessaries tee, elbow, socket, junction box etc all as specified and directed.
M&L for point wiring for one 15 Amp independant socket outlet using 4 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor cable drawn (red, yellow & blue) through & including non metalic rigid PVC concealed conduit (ISI marked) not less than 20mm dia, medium duty with all necessary fittings & accessaries including sunken steel boxex of suitable size with 3mm thick plastic laminated bakelite sheet incl FRLS PVC insulated unsheathed multistranded copper conductor cable of size 4 Sqmm (green colour) earth wire connecting to earth dolly , all as specified adn directed. Note :- The unit rate quoted includes the cost of cutting chases in surfacesfor conduits and fixing of sunken boxes and making good the disturbed surfaces to match the existing surfaces.
All as per description of Sl item No 68.00 here in before but for 15 Amp socket outlet in existing PVC Conduit Pipe
All as per description of Sl item No 68 here in before but for 15 Amp socket outlet in PVC casing & caping with all necessary fitting & accessaries tee, elbow, socket, junction box etc. all as specified and directed.
M&L for point wiring for metal plug top for Geyser / AC using 4.0 Sqmm FRLS PVC insulated unsheathed multi-strand copper conductor cable drawn through & including non metalic rigid PVC concealed conduit (ISI marked) not less than 20mm dia medium duty with all necessary fittings, incl FRLS PVC insulated unsheathed multistranded copper conductor cable of size 4.0 Sqmm (green colour) earth wire connecting to earth dolly , all as specified and directed. Note :- The unit rate quoted includes the cost of cutting chases in surfacesfor conduits and fixing of sunken boxes and making good the disturbed surfaces to match the existing surfaces.
All as per description of Sl item No 71.00 here in before but for Geyser / AC socket outlet in existing PVC Conduit Pipe
All as per description of Sl item No 71.00 here in before but for in PVC casing & caping with all necessary fitting & accessaries tee, elbow, socket, junction box etc. all as specified and directed.
S&F in repairs Switch piano flush button single pole one way 6 Amps 240 volts with polycarbonate body complete all as specified and directed.
S&F in repairs two way switch piano, flush button, single pole 6 amps 240 Volt with polycarbonate body complete all as specified and directed.
S&F in repairs Bell push switch piano flush button single pole one way 5 Amps 240 volts with polycarbonate body.
S&F in repairs multi purpose socket outlet for 2 &3 pin, 6A, flush type complete all as specified and directed.
S&F in repairs socket outlet 2 in 1, 3 pin, 6 and 16 Amps, flush type, single pole, one way, 230Volts complete all as specified and directed.
S&F in repairs switch piano, flush type, single pole, one way, 16 Amps 230Volts complete all as specified and directed.
S&F in repairs stepped type electronic mini/deluxe fan regulator 100 Watt rotary step all as specified and directed.
S&F for modular point wiring for one light/fan/bell point controlled by one switch complete with 1.5 Sqmm multistranded FRLS PVC insulated unsheathed, FRLS, multistranded copper conductor cable 1100 volts grade in and including non metallic rigid PVC medium duty concealed conduit with wall thickness not less than 20 mm dia including conduit accessories like bends, tees junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC green insulated unsheathed multi stranded copper conductor 1100 Volts grade as earth continuity wire connected to earth dolly including inner and outer frame plate of suitable moudle matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size, complete all as specified and directed. Note :- The unit rate quoted includes the cost of cutting chases in surfacesfor conduits and fixing of sunken boxes and making good the disturbed surfaces to match the existing surfaces.
All as per description of Srl item No 81.00 here-in-before but in existing PVC Conduit Pipe.
All as per description of Sl item No 81 here in before but in PVC casing & caping with all necessary fitting & accessaries tee, elbow, socket, junction box etc. all as specified and directed.
S&F for modular point wiring for one light point controlled by two 2-way switches complete with 1.5 Sqmm multistranded FRLS PVC insulated unsheathed, FRLS, multistranded copper conductor cable 1100 volts grade in and including non metallic rigid PVC medium duty concealed conduit with wall thickness not less than 20 mm dia including conduit accessories like bends, tees junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC green insulated unsheathed multi stranded copper conductor 1100 Volts grade as earth continuity wire connected to earth dolly including inner and outer frame plate of suitable moudle matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size, complete all as specified and directed. Note :- The unit rate quoted includes the cost of cutting chases in surfacesfor conduits and fixing of sunken boxes and making good the disturbed surfaces to match the existing surfaces.
All as per description of Sl item No 84.00 here-in-before but in existing PVC Conduit Pipe.
All as per description of Sl item No 84.00 here in before but in PVC casing & caping with all necessary fitting & accessaries tee, elbow, socket, junction box etc. all as specified and directed.
S&F for modular point wiring for one socket outlet 5 Amp, 5 pin for independent board controlled by one way switch complete with 1.5 Sqmm multistranded FRLS PVC insulated unsheathed, FRLS, multistranded copper conductor cable 1100 volts grade in and including non metallic rigid PVC medium duty concealed conduit with wall thickness not less than 20 mm dia including conduit accessories like bends, tees junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC green insulated unsheathed multi stranded copper conductor 1100 Volts grade as earth continuity wire connected to earth dolly including inner and outer frame plate of suitable moudle matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size, complete all as specified and directed. Note :- The unit rate quoted includes the cost of cutting chases in surfacesfor conduits and fixing of sunken boxes and making good the disturbed surfaces to match the existing surfaces.
All as per description of Sl item No 87.00 here-in-before but in existing PVC Conduit Pipe.
All as per description of Sl item No 87.00 here in before but in PVC casing & caping with all necessary fitting & accessaries tee, elbow, socket, junction box etc. all as specified and directed.
All as per description of Srl item No 87.00 here-in-before but for 5 pin 5 Amps socket outlet on same board controlled by one switch 5 Amps one way.
All as per description of Srl item No 87.00 here-in-before but for 5 pin 5 Amps socket outlet on same board controlled by one switch 5 Amps one way in existing conduit.
All as per description of Srl item No 87.00 here-in-before but for 5 pin 5 Amps socket outlet on same board controlled by one switch 5 Amps one way in PVC casing & caping with all necessary fitting & accessaries tee, elbow, socket, junction box etc.
S&F for modular point wiring for one socket outlet 15 Amp, on independent board controlled by one way switch complete with 4 Sqmm multistranded FRLS PVC insulated unsheathed, FRLS, multistranded copper conductor cable 1100 volts grade in and including non metallic rigid PVC medium duty concealed conduit with wall thickness not less than 20 mm dia including conduit accessories like bends, tees junction boxes etc fixed concealed/recessed in wall or ceiling etc including 4 Sqmm single core FRLS PVC green insulated unsheathed multi stranded copper conductor 1100 Volts grade as earth continuity wire connected to earth dolly including inner and outer frame plate of suitable moudle matching with surrouding with modular sunken steel boxes zinc oxide plated of suitable size, complete all as specified and directed. Note :- The unit rate quoted includes the cost of cutting chases in surfacesfor conduits and fixing of sunken boxes and making good the disturbed surfaces to match the existing surfaces.
All as per description of Sl item No 93.00 here-in-before but in existing PVC Conduit Pipe.
All as per description of Sl item No 93.00 here in before but in PVC casing & caping with all necessary fitting & accessaries tee, elbow, socket, junction box etc. all as specified and directed.
S&F in repairs one Module switch 1 way 10 Amps 240 volts complete all as specified and directed.
S&F in repairs one Module switch 1 way 16 Amps 240 volts complete all as specified and directed.
S&F in repairs Moduler bell push 6A, 240 volts 1 Module complete all as specified and directed.
S&F in repairs Modular socket 10A, 2 way, 240 volts pin 1 Module complete all as specified and directed.
S&F in repairs Modular socket 6A, 240 volts 2/3 pin 2 Module complete all as specified and directed.
S&F Modular socket 6A &16A, 240 volts 2/3 pin 2 Module complete all as specified and directed.
S&F in repairs Modular Fan step regulator 120W , 240 volts 2 Module complete all as specified and directed.
S&F in repairs ceiling rose surface bakelite 2 to 3 terminals with polycarbonate body complete all as specified and directed.
S&F in repairs lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F in repairs LED Lamp of 9W, Base B22, BEE 3Star complete all as specified and directed.
Supply & fix in repairs wall mounted 1x20 watt LED 6500K tube light fittings (4 feet long), Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with all accessories and making connection using 2 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
S&F in repairs LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V, AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repairs Energy efficient LED ceiling light 15W of size 1 feet x1 feet complete with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repairs Energy efficient LED ceiling/surface light of 12W to 15W, circular shape complete with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing in repairs of LED light fittings mirror type with high output diffuser 2 feet,10 watt 220 volt AC decorative type with driver holder and LED lamp including connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED in repairs of Bulk Head luminaries 10W complete with all accessories and including connector and connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete.
S&F in repairs decorative wall light white in colour made up of poly carbonate including 9 watt retrofit LED Lamp complete all as specified and directed.
Supply & Fixing in repairs building security LED light luminaire 30 W, IP 66, IK-07, AC 230 volts, made up of pressure di cast iron housing complete making connection using PVC insulated and sheathed3 core multi stranded copper conductor cable of size 0.50 Sqmm from ceiling rose including all as specified and directed by Engr-In-Charge.
Note for srl item No 105 to 113 above:- 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. Lenses shall be Modular Type. 8. PCB used shall be MC PCB type. 9. CA No. shall be written on each fitting before installation. 10. The name of manufacturer to be embossed on the fitting.
Note for srl item No 105 to 113 above:- (Contd..) 11. The fitting shall have arranged so that maintenance required, if any can be carried out from top cover. 12. The defect libility period of LED lights shall be 05 years from the certified date of completion & the contractor shall replace the defective fitting within 07 days after handing over for replacement. 13. A guaranty of 05 years shall be provided by contractor supported by OEM covering all parts of luminaire. Contractor shall deposit security on account of @ 5% of work done against these items otherwise the same shall be deducted from the dues payable to him in RAR/Final Bill.
S&F in repairs Bell, Ding Dong AC. 230 volts, single pole complete all as specified & directed.
S & F in repairs sheet metal enclouser single pole and neutral 240 volt , 20/32 Amps with two pin and earth plug and socket plug top complete with single pole MCBs all as specified and directed.
Supply and fix in repairs Sheet metal enclousre for DBs double door single pole and neutral with 200 amps rated bus bar of 4 - way, 240 volts complete all as spd and directed.
Supply and fix in repairs Sheet metal enclousre for DBs double door single pole and neutral with 200 amps rated bus bar of 8- way, 240 volts complete all as spd and directed.
Supply and fix in repairs Sheet metal enclousre for DBs double door single pole and neutral with 200 amps rated bus bar of 12- way, 240 volts complete all as spd and directed.
Supply and fixing in repairs MCB single pole and neutral 63 Amps, 240 volts, B-series complete all as specified and directed.
Supply and fixing in repairs MCB single pole and neutral, 40 Amps, 240 volts, B-series complete all as specified and directed.
Supply and fixing in repairs MCB single pole 16 to 32 Amps, 240 volts, B-series all as specified and directed.
M&L for sub main wiring with 6.0 sqmm copper conductor cable multistrand, FRLS PVC sheathed two run (as phase and neutral) and one run 6.0 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity drawn in existing surface / recessed steel / PVC conduit complete all as specified and directed.
M&L for sub main wiring with 6.0 sqmm copper conductor cable multistrand, FRLS PVC sheathed two run (as phase and neutral) and run 6.0 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity drawn in and including rigid non metalic PVC conduit complete all as specified and directed. Note:- The rate for concealed type point wiring shall deemed to include the cost of cutting, chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plasterand matching the surface by white wash/colour wash all as per existing finishes complete.
S&F sub main wiring with 10 sqmm copper conductor cable multistrand, FRLS PVC sheathed two run (as phase and neutral) and run 10 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in drawn in and including rigid non metalic PVC conduit complete all as specified and directed. Note:-the rate for concealed type point wiring shall deemed to include the cost of cutting,chasing in wall by using electric cutter and making good the disturbed surface of wall by providing cement plasterand matching the surface by white wash/colour wash all as per existing finishes complete.
S&F in repairs 2 module box cover plate with back plate for fixing of switches and sockets completeall as specified and directed.
S&F in repairs 3 module box cover plate with back plate for fixing of switches and sockets completeall as specified and directed.
S&F in repairs 4 module box cover plate with back plate for fixing of switches and sockets completeall as specified and directed.
S&F in repairs 6 module box cover plate with back plate for fixing of switches and sockets completeall as specified and directed.
S&F in repairs 8 module box cover plate with back plate for fixing of switches and sockets completeall as specified and directed.
S&F in repair bakelite sheet of size 5"x5" including cutting to required shape for fixing of existing switches and sockets completeall as specified and directed.
S&F in repair bakelite sheet of size 8"x5" including cutting to required shape for fixing of existing switches and sockets completeall as specified and directed.
S&F in repair bakelite sheet of size 10"x12" including cutting to required shape for fixing of existing switches and sockets completeall as specified and directed.
S&F in repair bakelite sheet of size 8"x10" including cutting to required shape for fixing of existing switches and sockets completeall as specified and directed.
S&F as in repairs sunken steel boxes zinc oxide plated of size 4''x4'' including cutting the wall to required shape and making good the disturbed surfaces to match existing one complete all as specified and directed.
S&F as in repairs sunken steel boxes zinc oxide plated of size 7''x4'' including cutting the wall to required shape and making good the disturbed surfaces to match existing one complete all as specified and directed.
S&F as in repairs sunken steel boxes zinc oxide plated of size 9''x11'' including cutting the wall to required shape for fixing and making good the disturbed surfaces to match existing one complete all as specified and directed.
S&F as in repairs sunken steel boxes zinc oxide plated of size 7''x9'' including cutting the wall to required shape for fixing and making good the disturbed surfaces to match existing one complete all as specified and directed.
Excavating in trenches in hard/dense soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n. exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
M&L for dry clean fine river sand as in sand cushioning to undergrouing cable including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
Supplying, jointing and connecting in repairs cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting in repairs cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting in repairs cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 150 sqmm to 185 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting in repairs cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 240 sqmm to 300 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting in repairs cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting in repairs cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting in repairs cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 150 sqmm to 185 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting in repairs straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 240 sqmm to 400 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supply and fixing as in repair/replacement of pole mounted street light factory fabricated junction box of size 200 x 160 x 250 mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet, including 63A, Three Phase four wire having four no of Alumimium Bus Bar including 6A SP MCB. The box shall have auto Door Lock facility with magnetic. Lock having Size box fixed on pole using necerssary fixing arrangement such as clamps, nut, bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed.
M&L for repairing, servicing and replacement of LT panels unserviceable part including complete broken accessories such as partialy open door, broken door, unserviceable aluminium bus bar, unserviceable/ broken locking arrangement, repairing of LT Panel legs, welding work, neceassry PCC work, excavtaion and earth work including disconnection and reconnection of cables with suitable size of Al Lugs in proper engineering practice, for any size of cables in any capacity LT Panel also Fixing of LT Danger Notice Plate both side of the panel, complete all as specified and directed. Note :- Only Danger Notice plate shall be measured and paid seperately.
M&L for painting of LT panel after removing old dust particles, oily portion by rubbing with sand paper and painting a coat of synthetic enamel paint with spray pump, and writing/digital printing, Capacity Descripton, date of installation,etc complete all as specified and directed.
M&L for painting of PCC pole 9/11 Mtr height without removing accessories with two coats of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamell paint . marking the pole number with black synthetic enamel paint over yellow circle of dia 100mm, Painting the steel parts i.e clamps, channels etc by applying two coats of aluminium paint all as required at site, complete all as specified and directed.
Taking down street light fitting or flood light fitting of any type and rating from poles, walls or any other indicated situation / location including removal of GI bracket pipe as directed, after disconnecting electrically. seggregating serviceable and unservicable fittings, keeping aside serviceable for re-use at same location or any other location with in the zone and removing unserviceable from site, complete all as specified and directed.
Supply, fixing and testing of 60W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete available CCT 5700K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance. LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply, fixing and testing of 150W LED Flood Light luminaire. LED Flood Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete available CCT 5700K, IP66 for Optical Compartment and Control Gear Compartment. The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Flood light should be top maintainable for easy maintenance. LED Flood Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Flood Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Flood Light shall have power factor more than 0.95 complete all as specified and directed.
Note for srl item No 157 to 158 above:- 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. Lenses shall be Modular Type. 8. PCB used shall be MC PCB type. 9. CA No. shall be written on each fitting before installation. 10. The name of manufacturer to be embossed on the fitting.
Note for srl item No 157 to 158 above (Contd..):- 11. The fitting shall have arranged so that maintenance required, if any can be carried out from top cover. 12. The defect libility period of LED lights shall be 05 years from the certified date of completion & the contractor shall replace the defective fitting within 07 days after handing over for replacement. 13. A guaranty of 05 years shall be provided by contractor supported by OEM covering all parts of luminaire. Contractor shall deposit security on account of @ 5% of work done against these items otherwise the same shall be deducted from the dues payable to him in RAR/Final Bill.
S&F in repairs electronic LED bldg security light driver of electronic driver after taking down bldg light, ISI approved company made as per existing make and size for suitable for LED fittings of cap upto 45 watts any type and make, and refixing the same complete all as specified and directed.
S&F in replacement of electronic LED security light driver ISI approved company suitable for LED fittings of cap upto 60 to 90watts any type and make, including taking out old one complete all as specified and directed.
S&F in replacement of electronic LED security light driver ISI approved company suitable for LED fittings of cap upto 100 to 200watts any type and make, including taking out old one complete all as specified and directed.
M & L for maintenance /repairs or periodical check by skilled crane repairer to all component of EOT crane 5 Ton capacity including limit switches vertical and horizontal motion and longitudial motion and load testing, greasing/ lubrication to all movable parts, rail track line of crane, adjustment/ rectification of flexible cable with cable carrier/ replacement of PVC cable carriers, rectification/ tightening of all electrical connections at main EOT panels and connected electrical drive motors, checking and rectification of brake system with checking of tie rod, checking of gear oil/ replacements of gasket/oil seal and required nut and bolts checking/rectification of portable/ pendent control panel and checking/rectification of cranes light points for smooth functioning and cleaning and dusting of all components complete all as specified and directed by Engr-in-Charge. Note-(i) All spares parts/ item/stores reuired for replacement shall be measured and saperately as respective sch 'A' ser items. (ii) Srl item No 1 in above labour only charges has been considered.
Supply and Fixing in repairs Lever Type Limit Switch 2 Way Type LS /2SH2 in IP54 enclosure with two Contacts for 2 ton to 5 Ton crane complete all as specified and directed.
S&F in repairs Rotary Type Limit Switch Gear Ratio 48:1 with 2 N.C.+ contact in IP 54 enclosure with two contacts for 2Ton to 5Ton crane complete all as specified and directed.
Supply and fixing in repairs electromagnetic break 200 mm 415 V AC supply for hoist motion complete suitable for 5 ton crane complete all as specified and directed.
Supply and Fixing in repairs of Electro hydraulic thruster operated brake suitable for hoisting motion/cross travel motion for crane 2 to 5 Ton crane, 415V, AC supply complete all as specified and directed.
Supply and Fixing in repairs of Electro hydraulic thruster operated brake suitable for long travel motion for crane 2 to 5 Ton crane, 415V, AC supply complete all as specified and directed.
Supply and fixing in repairs of Electro Hydraulic Thruster Break shoe 250 mm and 18 Kg for Hoist Motion/cross travel motioncomplete all as specified and directed.
Supply and fixing in repairs of Electro Hydraulic Thruster Break shoe 250 mm & 18 Kg for long travel motion complete all as specified and directed.
M&L for repairing of Helical Gear Box for Hoist Motion Horizontal Type opening and removing Hoist Gear Box Top Cover by unscrewing Nut Bolts , side shaft plates etc & replacement of damage oil Seal , gaskets of suitable size and replacement of gear oil after washing flushing & cleaning gear Box Chamber completely by kerosene oil,and refixing the same as directed. Note : Gear oill shall be measured & Paid separately
M&L for repairing of Helical Gear Box of L.T. & C.T. Motion Vertical Type for 2 ton to 5 ton crane and opening and removing of LT & CT Box Top Cover by unscrewing Nut Bolts , side shaft plates etc. replacement of Damage Oil Seal , Gaskets of Suitable size and replacement of Gear Oil after washing flushing & cleaning Gear Box chamber completely by kerosene Oil and refixing the same as directed. Note :( Gear oil will be measured & paid separately).
Supply and filling of Gear Oil complete all as specified and directed.
Supply and fixing of stainer wire 6 mm with end bracket 2 Nos for E.O.T Crane End Carriage side welded including cutting welding complete all as specified and directed.
M & L for power contactor 3 pole /2pole upto 30 Amp, 110 volt as per existing make model and size complete all as specified and directed.
M&L for overload relay upto 10 Amp as per existing make model and sizecomplete all as specified and directed.
M&L for dismantling/strip opening micro drive box complete with rectifier transformer arrangement, megnatic disc both side coupling for remotting both side ends of driving shaft (gear box coupling side and braking arrangement coupling side) making multi key arrangement on both the shaft and coupling (Teeth system) to avoid any kind of play in coupling and shaft including replacement of 04 Nos carbon bushes, replacement of 02 Nos gun metal bushes including making oiling arrangement in bushes and side covers of bushes/housing of micro drive reassembling/testing complete (crane capacity 2 to 5 Ton) all as specified and directed..
M &L for servicing of Push Button Station 8 way by opening, cleaning, soldering where required and replacement of unservicable Push Button with Element complete all as specified and directed. Cost of new Push Button with element included in unit rate.
M&L for break /compresure oil for EOT crane up to 5 Ton capacity complete all as specified and directed by engr-in-Charge.Make Survo/HP
M and L for grease for EOT crane up to 5 Ton capacity complete all as specified and directed.
M & L for replacement of flexible coupling suitable perfect allignment beetween motor and driven machine with greasing and replacement of suitable nuts and bolt complete all as specified and directed.
M & L for replacement of tie rod of break system and nut, bolt complete all specified and directed.
M&L for repairing of wheel for LT and CT upto 5 ton crane and removing bearing Cover by unscrewing Nut Bolts , side shaft plates etc & replacement of gaskets of suitable size and greasing of bearing after washing flushing & cleaning bearing and casing Chamber completely by kerosene oil,and refixing the same as directed by Engineer-in-charge. Note : Greasing will be measured & Paid separately.
M&L for earthing with steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI medium grade watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in electrical plate No 3 of SSR Part-I. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. all specified
Supply and fix in replacement of old unserviceable copper conductor cable 3 core PVC insulated and sheathed copper conductor cable of size 1.5 sqmm drawn through existing pole/GI pipe bracket complete all as specified and directed.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable , with aluminium conductor of size 16 Sqmm 2 core including taking out existing cable from trenches or fixed to wall/pole or passing through ducts or pipe of any size, any core , complete all as specified and directed.
All as per description of srl item No. 188.00 above but 16 Sqmm 2 core size complete all as specified and directed.
All as per description of srl item No. 188.00 above but 25 Sqmm 3.5 core size complete all as specified and directed.
All as per description of srl item No. 188.00 above but 35 Sqmm 3.5 core size complete all as specified and directed.
All as per description of srl item No. 188.00 above but 50 Sqmm 3.5 core size complete all as specified and directed.
All as per description of srl item No. 188.00 above but 70 Sqmm 3.5 core size complete all as specified and directed.
All as per description of srl item No. 188.00 above but 95 Sqmm 3.5 core size complete all as specified and directed.
All as per description of srl item No. 188.00 above but 120 Sqmm 3.5 core size complete all as specified and directed.
All as per description of srl item No. 188.00 above but 185 Sqmm 3.5 core size complete all as specified and directed.
All as per description of srl item No. 188.00 above but 240 Sqmm 3.5 core size complete all as specified and directed.
S & F in repair MCCB 4 Pole, 415 V, Adjustable Thermal Adjustable Magnetic (TM) type, 160 Amps rating, microprecesser based energy with rupturing capacity 36 KA complete all as specified and directed.
All as per description of srl item No. 198.00 here in before, but 200 Amps complete all as specified and directed.
All as per description of srl item No. 198.00 here in before,, but 250 Amps complete all as specified and directed.
All as per description of srl item No. 198.00 here in before,, but 315 Amps complete all as specified and directed.
All as per description of srl item No. 198.00 here in before, but 400 Amps complete all as specified and directed.
All as per description of srl item No. 198.00 here in before, but 600 Amps complete all as specified and directed.
AGGARWAL ASSOCIATES (BID ID -3429791)
KULBHUSHAN AGGARWAL (BID ID -3430396)
Standard engineers (BID ID -3427443)
SATISH AND CO (BID ID -3431478)
RATTAN CHAND CHANDAN AND CO (BID ID -3426792)
kailu construction co (BID ID -3430859)
JAI DURGA CONSTRUCTION CO (BID ID -3430430)
Abrol construction co (BID ID -3430997)
M/s Swastik Engineers (BID ID -3431481)
Bidder Name
kailu construction co
RATTAN CHAND CHANDAN AND CO
Standard engineers
KULBHUSHAN AGGARWAL
Vijay Kumar Contractor and Engineers
Abrol construction co
SATISH AND CO
AGGARWAL ASSOCIATES
JAI DURGA CONSTRUCTION CO
M/s Swastik Engineers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid