| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC C 488 SC PLOT NO 10 EKTA NAGAR NEAR ANANT LEWIS PUBLIC SCHOOL BANAR ROAD NANDRI PO SARAN NAGAR JODHPUR 342015 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.0 L+₹65,964.73 (1.60%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹44.9 L+₹3.6 L (8.62%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹45.3 L+₹4.0 L (9.63%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹49.5 L+₹8.2 L (19.8%)Rejected-Finance PLOT NO 28 B NAHAR SINGH JI KA HATHA BHATI CIRCLE RATANADA JODHPUR RAJ 342011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹83,600
Closing Date
14 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (A) Central Jodhpur
GE (A) Central Multan Line Army Area Jodhpur
CONSTRUCTION OF 1X TOILET AND 01 X BATHROOM NEAR BLDG NO TG15 CONSTRUCTION OF TOILET 2 URINALS NEAR BLDG NO 717 CONSTRUCTION OF 01 X TOILET BLOCK NEAR GP OFFICE BLDG NO P20 AND CONSTRUCTION OF TOILET NEAR BLDG NO 905 OF HQ CORPS ARTY BDE AND (9006/E8
2021_MES_430765_1
GE/J/A- OF2021-22 (9006/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (A) Central Multan Line Army Area Jodhpur
SPL REPAIR FOR REWIRING ALONGWITH REPLACEMENT OF ELECTRIC FIXTURES AND FITTINGS IN BUILDING NUMBER 1856 OFFICE COMPLEX 1848 COOK HOUSE OR LINE AND 1857 JCOS OR LINE OTM BLDGS OF WARCEN OTM ACCN BLDG NO P696 OF HQ 12 CORPS ARTY BDE CAMP
6 documents required · 6 mandatory
₹500
Yes
GE (A) Central Jodhpur
₹83,600
Yes
25 Sept 2021
15 Mar 2021
16 Apr 2021
15 Mar 2021
14 Apr 2021
30 Mar 2021
60 days
Amount
B/R Works Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 M in depth and getting out in soft/loose soil, complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations filling, sub base and mass concrete filling, complete all as specified and as directed.
M&L for squarred rubble walling Jodhpur type regular course, well bonded, bedded & solidly hearted, built in cement mortar 1:6, complete all as specified and as directed.
Extra over for hammer dressing to face stone with max depression on face from a streight edge not exc 20mm and dressing face beds and joints, complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil, complete all as specified and as directed.
Earth filling under floor, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed.
Removing of excavated materials to a distance not exceeding 50 M and deposing where directed at a level not exceeding 1.5 M above the starting point, complete all as specified and as directed.
M&L Precast cement concrete block masonary type C1 (1:3:6) 20 mm graded crushed stone agg with solid blocks 10 cm thichk and setting in cement mortar 1:6, complete all as specified and as directed.
M&L for hard core broken stone of gauge n. exc. 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, water and rammed to a true surface, complete all as specified and as directed.
M&L for 75mm thick cement concrete 1:4:8 ,type D-2 as in sub base to floor, complete all as specified and as directed.
M&L for 30mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base of floors, finished the surface even and rough, complete all as specified and as directed.
M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick 1st quality (square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cm 1:4, complete all as specified and as directed Make: Hajaria/ Somany
M&L for Glazed ceremic coloured tiles size 300mm x 4500mm and 7mm thick 1st quality as per IS-13712 Grade II(a) over 15mm thick rendering in CM (1:6) set and jointed in neat cement slurry and pointed with colour cement to match on vertical surfaces as in dados, complete all as specified and as directed. Make: Kajaria/ Somany
M&L for mild steel TMT or twisted bars 10 mm dia and over as in reinforcement cut to length, bent in shape required including cranking, bending, spirally hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and as directed.
All as per above item No 14 above but mild steel deformed or twisted bar 6mm to 8 mm dia.
All as per above item 14 but 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders
M&L for M-25(20mm graded crushed stone agg) design mix RCC in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed.
M&L for M-25 (20mm graded crushed stone agg) design mix RCC in beams, cantilevers, bressummers; lintels over 1.5m span, complete all as specified and as directed.
M&L for M-25 (12.5mm graded crushed stone agg) design mix RCC in Chhajjas, complete all as specified and as directed.
M&L for form work to soffits of roof slabs, floor slabs and similar work n exc 200 mm thick fair finished surfaces (flat), complete all as specified and as directed.
M&L for form work to Edges to conc flat 10-20 cm fair finished surfaces (flat), complete all as specified and as directed.
M&L for form work to Chajja fair finished surfaces (flat), complete all as specified and as directed.
Formwork for flat fair finished surface to sides & soffits of floor or roof beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc, complete all as specified and as directed.
M&L for 30mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in roofs, finished the surface even and smooth with WPC, complete all as specified and as directed.
M&L for carrying out water proofing treatment for roofs in the following stages. (a) First coat of mitumen primer confirming to IS-3384-1986 @ 0.40 kg/Sqm over and including 10mm thick cement mortar 1:4 surface finished even and smooth without using extra cement all as specified. (b) Second coat of bonding material using blown type bitumen confirming to IS-702-1988 grade 85/25 @ 1.20 Kg/Sqm. (c) Third coat of APP modified polymeric membrane centre core of 100 microne HMHDPE outer film 20 microne both sides thickness 2.00mm having weight 3.00 Kg/Sqm. (d) Fourth coat of bondig material using blown type bitumen confirming to IS-702-1998 of grade 85/25 @ 1.20 Kg/Sqm and sprinkling coarse (sieved) sand over hot bitumenous surface to form keys to hold PCC. (e) Fifth and top most layer of surface finish which act as protective layer shall be of 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded agg of crushed stone pedding well compected with V-shaped groove 6mm wide and 10mm depth filled with mastic bitumen of (1:1) of proportion complete, size of PCC panel with grooves shall not be exceed 0.36 Sqm all as specified.
M&L for roguhly squarred stone lintels hammer dressed on face and soffits hoisted, set and pointed incm 1:6 complete n.exc 3.00 m in length, complete all as specified and as directed.
M&L for 7.5cm thick sand stone slabs as in chajjas n.exc 2m in length punched dressed on face and along exposed edges, self faced on other side and set andpointed in cm 1:4, complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in copings, bed plates, plinth courses, parapets and the like including weathering, slightly rounded or chamfered angles and throating including use and waste of necessary form work etc, complete all as specified and as directed.
M&L for 50 mm thick PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in plinth protection laid in bays not exc 1.5m with expansion joints 30x10mm filled with mixture of hot bitumen and sand, finished the surface even and smooth without using extra cement, complete all as specified and as directed.
M&L for 15mm thick rendering in cm 1:6 on stone masonry finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for 10mm thick rendering in cm 1:6 on ceiling, concrete surface, finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for Keyed pointing to square rubble masonry Jodhpur type regular course in CM 1:3, complete all as specified and as directed.
M&L for 3 coats of white wash on walls including preparation to newly plastered surfaces preparation to newly plastered surfaces, complete all as specified and as directed.
All as per above item No. 33 but on ceiling.
Preparation of newly plastered/unplastered surfacce and applying two coats of cement based paint over one coat of Primer on wall, complete all as specified and as directed.
S&F factory made PVC door frames of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube suitable for opening as per site condition, complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 28 to 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement , supply and fixing in the frame, complete all as specified and as directed.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing , complete all as specified and as directed.
S&F 100mm long butt hinges, extruded alluminium alloy with galvanized mild steel hinge pin, anodized and fixed, type B-21, complete all as specified and as directed.
S&F 200mm long aluminium anodized barrel tower bolt of extruded section and fixed, complete all as specified and as directed.
S&F 150mm long alluminium handles, cast type, anodized and fixed, complete all as specified and as directed.
S&F of aluminium alloy anodised sliding door bolt woth hasp and stalpe (bolt type and fixings clips of sheet cast or extruded sections and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long, complete all as specified and as directed.
S&F steel windows or ventilators partly fixed and partly top hung with glazing bars, complete all as specified and as directed.
M&L for applying two coat of synthetic enamel paint on steel surfaces of any description not otherwise described over 10 cm width or girth over red oxide including necessary preparation, complete all as specified and as directed.
S&F 3mm thick sheet glass Pin headed and glazing with oil putty in squares not exc 0.5 Sqm in each pane, complete all as specified and as directed.
S&F vitreous china wash down water closet pan orrisa pattern, white excluding flushing cistern and flush pipe, complete all as specified and as directed.
S&F PVC low level 10 lit capacity valve less syphonic action type flushing cistern with inlet ball valve and handle including brackets, complete all as specified and as directed. Make: Parryware/ Cera/ Hindware.
S&F PVC connections of 15mm size with PTMT nuts of 600mm long, complete all as specified and as directed.
M&L Salt glazed stoneware gully traps of 100x100mm size, square or round mouthed, type‘P’, complete all as specified and as directed.
S&F bib taps 15mm, chromium plated, fancy type, cast copper alloy with crutch or butter fly handle screwed down screwed for iron pipe 15mm bore, complete all as specified and as directed.
S&F stop valves, 15mm chromium plated, fancy type, cast copper alloy, screwed down, high pressure with crutch or butter fly handles, screwed both ends for iron pipe 15mm dia, fixed, complete all as specified and as directed.
Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats .(Minimum weight 170gms), complete all as specified and as directed.
S&F Soap dish, vitreous China white, approximate size 160x160x90mm, complete all as specified and as directed.
M&L for 75mm dia of outlet, PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall, complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in wall or in floors, complete all as specified and as directed.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to trenches, complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) bends any radius with oval access doors, complete all as specified and as directed.
S&F PVC (SWR) vent cowl suitable for 100mm bore of pipe, complete all as specified and as directed.
S&F 110 mm dia PVC (SWR) junction (single ‘T’) equal or un-equal with access door, complete all as specified and as directed.
S&F grating dome 100mm dia of PTMT (minimum weight 25 gms), complete all as specified and as directed.
S&F 110 mm dia PVC (SWR) reducers, complete all as specified and as directed.
M&L for vitreous China bowl urinal flat back, size of 465 x 355 x 265mm white, with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe), complete all as specified and as directed.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks triple layer white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including one 20mm PTMT ball valve with polythene float and fly nut, complete all as specified and as directed. Make: Sintex/ Rolex/ Polytuff
S&F 15 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid in floors, complete all as specified and as directed.
S&F 20 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid in floors, complete all as specified and as directed.
M&L for machine cut kota stone slab 40-50 mm thick as in partition of urinal, complete all as specified and as directed.
Cutting chasing pinning in making good to facing in CM 1:3 exe 10cm but n. exe 20 cm in stone wall, complete all as specified and as directed.
S&F guard bars with ends of bars shouldered, complete all as specified and as directed.
M&L 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate), complete all as specified and as directed.
M&L for 100mm thick cement concrete type D-2, 1:4:8, as in sub base to floor, complete all as specified and as directed.
M & L for Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted & set, jointed & grouted in cement mortar 1:3, complete all as specified and as directed.
Supply and fabrication of Mild steel guard bars and welded to window frames, complete all as specified and as directed.
Supply and fixing of vitreous china Squatting pan Orrisa pattern size 580x440mm white with integral foot rest one piece incl 'P' or 'S' trap complete as in repairs, complete all as specified and as directed. Make: Parryware/ Cera/ Hindware.
S&F vitreous china wash down water closet pan (Pedestal pattern) white connected to drain or out going pipe and flushing pipe complete as in repair including PVC sheet cover closed recesed type complete all as specified and as directed. Make: Parryware/ Cera/ Hindware.
S&F vetrious china wash basin white flat back 550x400mm including brackets, vitreous china padastal, 32mm bore CP coupling etc, complete all as specified and as directed. Make: Parryware/ Cera/ Hindware.
S&F 15mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and as directed. Make: Jaquar/ Cera
Flush pipe of polythylene of low or high density or PVC 32mm dia for WHB, complete all as specified and as directed.
S&F tubular towel rail 20mm dia brass chromium plated `D' type 60cm long with bracket and fixed , complete all as specified and as directed. Make: Jaquar/ Cera
S&F 100mm bore CI Tee ordinary or inverted, complete all as specified and as directed.
M&L cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete with outlet dia 100mm, complete all as specified and as directed.
M&L for SGSW gully trap , square or round mouthed, type "P" 180x150 mm, complete all as specified and as directed.
S&F100mm bore cast iron sand cast soil and vent pipe in any length with or without ears with cement joints on wall, complete all as specified and as directed.
All as per above item No. 86 but 75 mm bore in floor.
S&F100mm bore cast iron bends ( any radius ) diminishing piece ( larger bore measured), complete all as specified and as directed.
S&F for 75mm bore cast iron bends ( any radius ) diminishing piece or larger bore measured, complete all as specified and as directed.
Cast iron vent cowls sand cast, for 100 mm bore pipe jointed in cement mortar, complete all as specified and as directed.
S&F CP grating 100mm dia, complete all as specified and as directed.
S&F 100 mm CI bend, complete all as specified and as directed.
M&L for rendering 10mm thick on concrete surfaces in CM 1:3, finish the surface even & fair, complete all as specified and as directed.
M&L for vitreous china bowl urinal flat back size 465 x 355 x 265mm white (minimum) with grating and union for discharge pipe, complete all as specified and as directed.
M&L for 30mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in roofs, finished the surface even and smooth with WPC, complete all as specified and as directed.
M&L for 75mm thick cement concrete type D-2, 1:4:8, as in sub base to floor, complete all as specified and as directed.
S&F machine made precast cement concrete blocks (Interlocking pavers ) rubberised finished coloure of 60mm thick top layers of anti abrasive material and with including laid over 50mm thick sand cushion. The interlocking tiles joint will be filled with fine sand, complete all as specified and as directed.
S&F for providing precast cement concrete block in PCC 1:2:4 Type B-1 (Using 20mm graded agg) as in kerb stone etc. and setting in CM 1:6 complete with joints to match, complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in soft/ loose soil, complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations filling, sub base and mass concrete filling, etc, complete all as specified and as directed.
M&L for squarred rubble walling Jodhpur type regular course, well bonded, bedded & solidly hearted, built in cement mortar 1:6, complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings, bed plates, plinth courses, parapets and the like including weathering, slightly rounded or chamfered angles and throating including use and waste of necessary form work etc, complete all as specified and as directed.
Providing precast RCC using 20mm graded aggregate as in cover slab for man hloes set in CM 1:6, complete all as specified and as directed.
S&F TMT bars 6mm dia to 8mm dia , cut to length , bent to shape required, incld cranking, bending spirally for hooping for columns, hooking ends and binding with and incld mild steel wire (annealed) not less thaan 0.90mm dia or securing with clips, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils, complete all as specified and as directed.
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point, complete all as specified and as directed.
M&L for 150mm dia SWG pipes grade'A' laid in trenches and jointed in CM 1:1 complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore, complete all as specified and as directed.
Cutting into existing manholes for connecting new drain pipe and making good to pipe and rendering cutting out existing benching for and forming branch (1/2type B-1 smooth finished, and reforming benching as required] round or 3/4th Section) in cement concrete 1:2:4 channel, complete all as specified and as directed.
M&L for connecting 20 mm bore GI pipe from existing water supply line including necessary excavation ,clamping making holes to existing pipe line, complete all as specified and as directed.
S&F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20mm bore and fixed, complete all as specified and as directed
E/M Works Taking down carefully copper/aluminium point wiring for light, fan, bell socket power slocket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose etc, complete all as directed.
Taking down carefully sub-main wiring of any description and making good to ther disturbed surfaces to match the existing all as specified and as directed by EIC, complete all as directed.
Point wiring (Concealed) using approved colour coding as per IS Red Black and green for single phase circuits) with multi stranded copper conductor 1.5 Sqmm nominal cross area single core PVC insulated and unsheathed FR LS cable 1100 Volts grade ISI 694 marked with valid CML No. in and including medium grade PVC concealed conduit of dia not less than 20mm and conduit accessories (ISI Marked) with valid CML No. ( IS 9537 -1983 for wall/roof /floor etc with pressed flush metal boxes covered with inner plates & outer plates etc suitable for mounting of Modular switches & sockets including PVC insulated multi stranded copper conductor FRLS 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continully conductor to commonearth and connecting to earrth dolly complete all as specified and directed for the follwing, complete all as specified and as directed. (a) One light point controlled by one, one way switch
(b) All as per above item No. 115 but One fan /Exhaust fan, point controlled by one way switch complete.
(c) All as per above item No. 115 but One socket outlet 3 pin 6 Amps on same board complete.
(d) All as per above item No. 115 but One socket outlet 3 pin 6 Amp on independent board complete.
(e) All as per above item No. 115 but One bell point controlled by one bell push complete.
(f) All as per above item No. 115 but One light point controlled by two, two-way switches complete.
M&L for point wiring (surface) complete with FR LS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in PVC Caping/Casing of size 20x12 to 25x16, (ISI Marked), 19/20 mm dia including all accessories and making good the disturbed surface, with and including suitable modular boxes surface type of make legrand ,switch plates of make Legrand and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed by Engr-in-charge. Make of cable : Polycab, Finolex ,Havells (a) One light point controlled by one switch.
(b) All as per above item No. 121 but One ceiling/exhaust fan point controlled by one switch complete.
(c) All as per above item No. 121 but One 3 pin socket outlet 6 amps on independent board complete.
(d) All as per above item No. 121 but with 2.5 Sq mm single core multistanded copper conductor cable for 3 pin 16 Amp socket outlet on independent board complete.
(e) All as per above item No. 121 but with 4.0 Sq mm single core multistanded copper conductor cable for 3 pin 16 Amp socket outlet on independent board complete.
M&L for Point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC (FR) insulated unsheathed cable confirming to IS-694,1100 Volts grade (ISI Marked) in and including PVC rigid conduit (MMS) (ISI Marked) with accessories fixed Concealed in wall / roof / ceiling etc and including sunken pressed steel terminal boxes in wall and 1.50 sq mm PVC insulated unsheathed stranded copper conductor for common earth and connecting to earth dolly material and labour for, complete all as specified and as directed :- (a) One light point controlled by one, one way switch
(b) All as per above item No 126 above but One light point controlled by two two way switchs complete.
(c) All as per above item No 126 above but One fan /Exhaust Fan point controlled by one way switch complete.
(d) All as per above item No 126 above but One socket outlet 3 pin 5/6 Amps on same board complete
(e) All as per above item No 126 above but One socket outlet 3 pin 5/6 Amp on independent board complete
(f) All as per above item No 126 above but with 2.5 Sq mm single core multistanded copper conductor cable for 6 pin 15 Amp socket outlet on independent board complete.
S&F Modular switch flush type single pole one way 5 Amp (ISI Marked), complete all as specified and as directed. Make:Legrand/L&T/Schneider
S&F Modular switch flush type single pole one way 15 Amp (ISI Marked), complete all as specified and as directed. Make : Make:Legrand/L&T/Schneider
supply & Fix Modular Fix only switch flush type single pole two way 5 Amp (ISI Marked), complete all as specified and as directed. Make : Make:Legrand/L&T/Schneider
supply & Fix only Modular bell push, flush type, 5 Amp (ISI Marked), complete all as specified and as directed. Make:Legrand/L&T/Schneider
Supply and fix bell, AC 230 volts, single pole Multi tune type, complete all as specified and as directed. Make : Havells/Anchor/Cona
S&F Modular socket outlet 2 in 1, 5 pin, 5 Amp flush type, complete all as specified and as directed. Make:Legrand/L&T/Schneider
S&F Modular socket outlet 2 in 1, 6 pin, 5 and 15 amp flush type ISI Market, complete all as specified and as directed. Make:Legrand/L&T/Schneider
Supply and fix modular socketed stepped type electonic fan regulator flush type, complete all as specified and as directed. Make:Legrand/L&T/Schneider
S&F switch flush type single pole one way 6 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ ABB/ L&T/ Schneider
S&F switch flush type single pole two way 6 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ ABB/ L&T/ Schneider
S&F switch flush type single pole one way 16 Amp (ISI Marked), complete all as specified and as directed. Make : Legrand/ ABB/ L&T/ Schneider
S&F socket outlet 3 pin, 6 Amp flush type (ISI Marked), complete all as specified and as directed. Make : Legrand/ ABB/ L&T/ Schneider
S&F socket outlet 2 in 1, 6 pin, 6 and 16 amp flush type (ISI Marked), complete all as specified and as directed. Make : Legrand/ ABB/ L&T/ Schneider
supply and fix socketed stepped type electonic fan regulator (ISI Marked) . flush type, complete all as specified and as directed. Make : Legrand/ ABB/ L&T/ Schneider/HPL
S&F Ceiling rose, 3 terminal/PVC/ polycarbonate, isolated body, complete all as specified and as directed.
S&F insulated Batton lamp holder metal cased body of brass with back plate suitable for batton fittings including 9 watt LED Lamps (ISI Marked), complete all as specified and as directed.
Fixing only LED tube light 20 watt, complete all as specified and as directed. (LED will be issued under Sch 'B')
S&F LED tube light fitting Box type 20 watt complete with all accessories such as bipin holders connector block, etc internally pre-wired , including LED lamp-1No, connectiong up with , multistranded copper conductor of size 1.00 sq mm flexible cable Make :Crompton Fitting Cat No-DMLN1LTD8-16 & LED Lamp Cat No-LTT8-20 or equivalent in Havells Cat No LHEXBHP7PN1W020 /philips Cat part No-BN150W LED20S, complete all as specified and as directed.
S&F Surface mounting LED Luminaries and 1 x 9 Watt LED fitting with connecting up with copper 3 core flexible cord of minimum size 1.5 Sqmm size complete all as specified and as directed . Make : CG/ Phillips/ Wipro
Supply and Fixing LED bulk head light 8/10 watt, including taking down u/s fitting any type, complete all as specified and as directed. Make : Havelles/Philips/Bajaj
Supply & fixing 2'x2' LED flat panel (recess type)suitable for armstrong/grid/POP ceiling complete with separate electronic driver & high brightness diffused type, complete all as specified and as directed. Make : CG, Phillips, Wipro (CG Model No :- LBRP40CL22CD) or Equivalent
S&F LED security light fitting 25 Wmade out of pressure die cast aluminium powder coated housing high impact resistant 4 mm thick toughened glass cover and matrix of power LEDs in built electronic driver up to 4 KV surge protection fitted with adjustable pole adopter to enable on site tilt angle setting and input power 25 W system lumens 85/W operating voltage 160-260 V of make : CG Cat Part No. LSTS-25-CDL :- Note :(i) Rates are deemed to be included for security ligh brackets made out of 25 mm / 20 mm dia GI medium grade tubing of suitable length and bend to shape including fixing MS flat iron clamps, bolts & nuts as per site requirement complete in all respect complete all as specified and as directed.
M&L for sub main wiring (concealed) complete with four single core 10 Sqmm FR LS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 to 32 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 10 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface, complete all as specified and as directed. Make of cable : Polycab, Finolex,Havells Note: 5 run of 10 sqmm & one run of PVC conduit shall be measured as single unit
M&L for sub main wiring (concealed) complete with four single core 6 Sqmm FR LS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 6 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface, complete all as specified and as directed. Make of cable : Polycab, Finolex,Havells Note: 5 run of 6 sqmm&one run of PVC conduit shall be measured as single unit
M&L in repairs sub main wiring with 2 X 6.00 Sq mm single core multistrandred copper conductor PVC insulated and unsheathed cable passing through PVC concealed conduit and making good the distrurbed surface of wall inc 6 Sq mm single core copper conductor cable PVC insulated and unsheathed cable as earth wire. Note :- Two runs of cable 6 Sqmm and One run of 6 Sqmm shall be measured as unit length, complete all as specified and as directed.
M&L in repairs sub main wiring with 2 x 4.00 Sq mm single core multistrandred copper conductor PVC insulated (FR ) and unsheathed cable passing through in and including PVC conduit medium grade compleate with all acessories concealed in wall and making good the distrurbed surface of wall incl 4 Sq mm single core copper conductor cable PVC insulated and unsheathed cable as earth wire. Note :- Two runs of cable 6 Sqmm and One run of 4 Sqmm and one run of conduit shall be measured as unit length, complete all as specified and as directed.
Supply and fixing of sheet metal enclosure SPN with a two pin earth plug and socket with metal cladd top and one MCB,SP 20amps capacity, complete all as specified and as directed. Make: Legrand/ ABB/ Seimens.
S&F power unit for upto 2 ton AC and geyser up to 3.5 KW modular type , 4 module,240 volts , complete all as specified and as directed. by EIC. Make : Legrand Cat No. 675558
S & F sheet metal enclosures for DB V-TPN for incorporating MCCB 100 to 160 Amp as incoming & MCBs, TP, 4 way as outgoing, IP-54 with metal double door with 200 amps rated busbar, 415 volts, as per IS-8623 including taking down the old unserviceable TPN DB,, complete all as specified and as directed. Make : Legrand Cat No 507750/ ABB/ Seimens.
S & F sheet metal enclosures for DB V-TPN for incorporating MCB 100 Amp as incoming & MCBs, TPN, 6 way as outgoing, IP-54 with metal double door with 100 amps rated busbar, 415 volts, as per IS-8623 including taking down the old unserviceable TPN DB,, complete all as specified and as directed. Make : Legrand Cat No 507736/ ABB/ Seimens.
S&F Prewired distribution board in sheet metal encl , prewired when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 12 way , cat no. - SD 3707, complete all as specified and as directed. Make : Legrand Cat No 507736/ ABB/ Seimens.
S&F distribution board in sheet metal with 200 Amps rated copper bus bar Confirming to relevant IS.SPN 8 way, Note -Rate are deemed to be included for fixing in wall concealed complete, making good and matching existing surface, complete all as specified and as directed. Make;-Legrand/ ABB/ Havell's
S&F Prewired distribution board in sheet metal encl , prewired when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 4 way , cat no. - SD 3707, complete all as specified and as directed. Make: LEGRAND/ ABB/ Seimens
Taking out old U/S DB's with wooden board / boxes S&F distribution board manufacturer prewired , IP 42 in sheet metal enclosure dully flushed in wall, when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 4 way cat no.- SD-3809 ,and making good the disturbed surface, complete all as specified and as directed. by Engg-in-charge. Make: LEGRAND/ ABB/ Schneider
S&F Prewired distribution board in sheet metal Prewired when MCB to be used with 200 Amps rated copper bus bar Confirming to relevant IS TPN 4 way, Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface, complete all as specified and as directed. Make;-Legrand/ ABB/ Havell's
S&F MCB SP 10-32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and as directed. Make : Legrand or equivalent in ABB/ Seimens
S&F MCB SPN, 32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and as directed. Make : Legrand Cat No. 408617/ ABB/ Seimens
S&F MCB SPN, 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and as directed. Make : Legrand Cat No. 408617/ ABB/ Seimens
S&F MCB TPN, 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and as directed. Make : Legrand Cat No. 408704/ ABB/ Seimens
S&F RCCB DP 63 Amps, breaking capacity 30 mA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc, complete all as specified and as directed. Make : Legrand Cat No. 408704/ ABB/ Seimens
M&L for disconnecting electric supply, taking down fan, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan, exhaust fan of any make from existing position and bringing to AGE E/M store yard for repairs, overhauling, oiling, greasing and cleaning all dusts and rehanging in position and connecting up electrically including minor items like split pins complete all as specified and as directed by EIC. Note: Complaint slip regarding the fan should be obtained from concerned JE (E/M) of AGE E/M office every day and completion on the complaint must be intimated to concerned JE (E/M) after rectification every day. Rewinding work and replacement of spares shall be measured and paid separately under appropriate items. No supporting materials, tools and plants shall be issued by MES to contractor, complete all as specified and as directed.
Supply and fixing Ceiling fan 1200 mm sweep , 5 starrated and necessary electric connection, complete all as specified and as directed.by engineer-in-charge.Make:Bajaj/crompton/Havell's
Supply and fixing Exhaust fan 300 mm , sweep , Noise less, and necessary electric connection, complete all as specified and as directed. by engineer-in-charge.Make:Bajaj/crompton/Havell's
Supply and fixing Exhaust fan 250 mm , sweep , Noise less, and necessary electric connection , complete all as specified and as directed. by engineer-in-charge.Make:Bajaj/crompton/Havell's
Taking down and re fixing of exhaust fan repair work and making connection, complete all as directed.
Supply and fixing MCCB 160 Amps 25 KA including sheet metal enclosure powder coated finish and fixed flush in wall including making good to distrubed surface etc, complete all as specified and as directed.
S&F MCCB 4 Pole 100 A mps 16 KA, complete all as specified and as directed. Make: Legrand/ABB/Schneider
Supply and fixing Sheet metal Busbar chamber factory fabricated powder coated finish complete with copper busbar TPN 125 Amps including fixing arrangement etc, complete all as specified and as directed.
Supply,laying and fixing only along the poles,floor, ground or passing through walls etc jointing and testing LT Cross Linked Polythene Insulated galvanised steel strip armoured electric cable 1100 volt grade heavy duty (ISI Marked) with aluminium conductor and overall served with an outer sheath of PVC of cross sectional area 16 sqmm x 4 core (ISI Marked), complete all as specified and as directed. by Engg-in-charge.
Supply and fixing MCCB 125 Amps 25 KA including sheet metal enclosure powder coated finish and fixed flush in wall including making good to distrubed surface etc, complete all as specified and as directed Make: Legrand/ ABB/ Schneider
Supply and fixing Sheet metal Busbar chamber factory fabricated powder coated finish complete with copper busbar TPN 250 Amps including fixing arrangement etc, complete all as specified and as directed.
Excavating in trenchs in soft/loose soil, n exc 1.5m wide and n exc 1.5m in depth; for laying of cables etc. n.exc 10sq m on plan and n exc 1.5m in depth and getting out, complete all as specified and as directed.
Removing surplus excavated material (soil) not exceeding 50 metre and deposRing where directed at a level not exceeding 1.5 metre above the starting point, complete all as directed
Returning, filling in trenches with excavated soil, including, spreading, levelling, watering and well rammin in la ers not exceeding 25 cm thick, complete all as specified and as directed.
S&L Jodhpur stone quarry faced stone slab cover 40 to 50mm thick, 25cm to 30cm wide, 60cm long, laid dry and abutting each other with gap cetween adjacent slab not exceeding 10mm over under ground cables for protection, complete all as specified and as directed.
Sand cushioning to under ground cable using river sand and gently punning for cushioning to cable, complete all as specified and as directed.
S&F GI Pipe 40mm bore galvanized iron light grade complete with all fittings laid in road crossing, and on pole, floors buildings(ISI Marked), complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60 x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate no. 3 connected to Earthing test point all as specified or indicated including testing on completion Note : (i) Rates are deemed to be included for necessry earth work ,PCC pit , RCC cover etc complete. (ii) Earth lead shall be up to 7.5 Mtr and rates are deemed to be included for GI pipe 15mm Light grade upto 7.5 mtrs for protection of earth wire 4.0 mm dia.
M&L for Point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC (FR LS) insulated unsheathed cable confirming to IS-694,1100 Volts grade (ISI Marked) in and including PVC rigid conduit (MMS) (ISI Marked) with accessories fixed Concealed in wall / roof / ceiling etc and including sunken pressed steel terminal boxes in wall and 1.50 sq mm PVC insulated unsheathed stranded copper conductor for common earth and connecting to earth dolly material and labour for, complete all as specified and as directed : (a) One light point and Exhaust Fan point controlled by one, one way switch
(b) One socket outlet 3 pin 5/6 Amp on independent board
All as per item No 78 above but with 2.5 Sq mm single core multistanded copper conductor cable for 6 pin 15 Amp socket outlet on independent board .
S&F LED tube light fitting., 1 x 20 /22w, T8, Complete 230 v ( power factor not less than 0.90 ), etc. complete with all accesssories internally pre-wired , and connectiong up with PVC insulated and sheathed , 1100 volts grade , flexible , multistranded 1.0 sq mm copper conductor three core cable, complete all as specified and as directed. Make: Philips/ Bajaj/ Havells
Supply and Fix Exhaust Fan with Louvers 250 mm Sweep , 240 Volt , Single phase with proper conection to ceiling Rose, complete all as specified and as directed. Make: Philips/ Bajaj/ Havells
Supply and Fix Building Seurity Light LED Type 1x45W,, single phase 240V comprising of , all fittingslfixtures pre-wired, , with epoxy powder coated, with rubber gasket with hinge arrangement on one side and two latches on the other side including 25 mm dia galvinised iron pipe light grade bracket bent to shape over all length 1.6 mtr fixed to wall with 2 Nos F1 clamps made of 40x6 mm F1 and 15 cm long 8 mm dia boiJts and nuts with washers grouted in wall including , all accessories pre-wired all as specified. Street light fitting, complete all as specified and as directed.. Make: Philips/ Bajaj/ Havells
S&F MCB SPN 40 amps 10 Ka, "C' series, complete all as specified and as directed. Make: Legrand/ABB/C&S/Schneider
S&F MCB single pole 5 to 30 Amps, 10 Ka, "C' series, complete all as specified and as directed. Make: Legrand/ABB/Schneider
Note for all above items:-All items in BOQ are for"Materials and labour /Supply and fix" and to be executed in "Repairs i.e incl takng down old items" unless otherwise specifically mentioned as "Supply only" or "fixing only" in BOQ. Contractors are required to quote their rates accordingly.
Nikhat nirman
Narendra General Suppliers
Dwarka Enterprises
BEYLIM INFRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .