Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 02 PARIMPORA NEAR NEW BUS STAND SRINAGAR SRINAGAR JAMMU KASHMIR 190017 | SRINAGAR | JAMMU AND KASHMIR | 190017 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical INSUFFICIENCY |
Tender Value
Refer Docs
Closing Date
13 Apr 2022, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER STD 2ND RAJBAGH
OFFICE OF THE EXECUTIVE ENGINEER STD 2ND RAJBAGH
Annual rate contract for Repairs and Maintenance of 33/11KV Receiving Stations falling under the jurisdiction of Sub Transmission Division-II, Rajbagh, Srinagar for the year 2022-23 or till next rate contract
2022_PDD_164785_1
eNIT No. STD-II / 02 of 2022-23 Dated 16-03-2022
Open Tender
Electrical and Maintenance Works
Item Rate
1 days
SRINAGAR AND BUDGAM
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,100
EXECUTIVE ENGINEER STD 2ND RAJBAGH
Exempted
23 Apr 2022
24 Mar 2022
14 Apr 2022
24 Mar 2022
13 Apr 2022
29 Mar 2022
180 days
Amount
Dismantalling of 11KV VCB Panel
Dismantalling of 33KV C&R Panel
Dismantalling of 33KV VCB / MOCB
Installation,testing and commissioning of 11KV VCB Panel complete (material to be provided by the department)
Installation,testing and commissioning of 33KV C&R Panel complete (material to be provided by the department)
Installation,testing and commissioning of 33KV VCB complete (material to be provided by the department)
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Alsthom make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Easun Reyroll Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Vijay Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Sudhir Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Electric Field Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Crompton Greeves Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Allind Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Pascal Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of L&T Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of ABB Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of S&S Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of BHEL Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Beeco Lawrie Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Stelmec Make
Supply,installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Southern Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Alsthom make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Easun Reyroll Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Vijay Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Sudhir Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Electric Field Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Crompton Greeves Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Allind Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Pascal Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of L&T Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of ABB Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of S&S Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of BHEL Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Beeco Lawrie Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Stelmec Make
Installation,testing and commissioning of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB Panels of Southern Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Alsthom make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Easun Reyroll Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Vijay Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Sudhir Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Crompton Greeves Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Electric Field Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Allind Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Pascal Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of L&T Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of ABB Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of S&S Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of BHEL Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Beeco Lawrie Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Stelmec Make
Supply,installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Southern Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Alsthom make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Easun Reyroll Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Vijay Make
Installation, testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Sudhir Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Crompton Greeves Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Electric Field Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Allind Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Pascal Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of L&T Make
Installation, testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of ABB Make
Installation, testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of S&S Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of BHEL Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Beeco Lawrie Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Stelmec Make
Installation,testing and commissioning of 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels of Southern Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Alsthom make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Easun Reyroll Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Vijay Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Sudhir Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Electric Field Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Crompton Greeves Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Allind Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Pascal Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of L&T Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of ABB Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of S&S Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of BHEL Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Beeco Lawrie Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Stelmec Make
Providing and fixing of fresh male contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Southern Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Alsthom make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Easun Reyroll Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Vijay Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Sudhir Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Electric Field Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Crompton Greeves Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Allind Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Pascal Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of L&T Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of ABB Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of S&S Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of BHEL Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Beeco Lawrie Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Stelmec Make
Providing and fixing of fresh female contact set for following 11KV VCB by way of Replacement of Damaged/Burnt Out male contact set of same composition,type,make and class already installed in 11KV VCB panel of Southern Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Alsthom Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Easun Reyroll Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Vijay Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Sudhir Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Electric Field Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Crompton Greeves Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Allind Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Pascal Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels L&T Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels ABB Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels S&S Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels BHEL Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Beeco Lawrie Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Stelmec Make
Supply,installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Southern Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Alsthom Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Easun Reyroll Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Vijay Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Sudhir Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Electric Field Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Crompton Greeves Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Allind Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Pascal Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels L&T Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels ABB Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels S&S Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels BHEL Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Beeco Lawrie Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Stelmec Make
Installation,testing and commissioning of 11 KV Espout Bushing for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Espout Bushing of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Southern Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Alsthom Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Easun Reyroll Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Vijay Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Sudhir Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Electric Field Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Crompton Greeves Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Allind Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Pascal Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels L&T Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels ABB Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels S&S Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels BHEL Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Beeco Lawrie Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Stelmec Make
Supply,installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Southern Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Alsthom Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Easun Reyroll Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Vijay Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Sudhir Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Electric Field Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Crompton Greeves Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Allind Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Pascal Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels L&T Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels ABB Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels S&S Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels BHEL Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Beeco Lawrie Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Stelmec Make
Installation,testing and commissioning of 11 KV Bush with rods for 11KV VCB Panels by way of replacement of Damaged/Burnt Out 11 KV Bush with rods of same type,make and class already installed in panel confirming to IEC 60044-1-2000 standards suitable for 11KV VCB panels Southern Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Alsthom make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Easun Reyroll Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Vijay Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Sudhir Make
Supply, Installation, testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Electric Field Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Crompton Greeves Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Allind Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Pascal Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of L&T Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of ABB Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of S&S Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of BHEL Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Beeco Lawrie Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Stelmec Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Southern Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panelof Alsthom make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Easun Reyroll Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Vijay Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Sudhir Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Electric Field Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Crompton Greeves Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Allind Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel (MATERIAL TO BE PROVIDED BY DEPARTMENT) of Pascal Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of L&T Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of ABB Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of S&S Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of BHEL Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Beeco Lawrie Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Stelmec Make
Installation,testing and commissioning of 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in 11kV VCB panel of Southern Make
Providing & fixing of damaged clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A, 33KV Isolator) with fresh one complete.
Fixing of damaged clamps (A.A) confirming to IS:617 standards (for 33KV VCB,33KV L.A,33KV Isolator) with fresh one complete.
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Alsthom make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Easun Reyroll Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Vijay Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Sudhir Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Electric Field Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Crompton Greeves Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Allind Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Pascal Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of L&T Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of ABB Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of S&S Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of BHEL Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Beeco Lawrie Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Stelmec Make
Supply,installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Southern Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Alsthom make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Easun Reyroll Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Vijay Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Sudhir Make
Installation,testing, commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Electric Field Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Crompton Greeves Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Allind Make
Installation,testing, commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Pascal Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of L&T Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of ABB Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of S&S Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of BHEL Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Beeco Lawrie Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Stelmec Make
Installation,testing,commissioning of Tripping coils (36V) by way of Replacement of Damaged/Burnt Out Tripping coil of same composition, type, make already installed in 11kV VCB panel of Southern Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Alsthom make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Easun Reyroll Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Vijay Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Sudhir Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Electric Field Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Crompton Greeves Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Allind Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Pascal Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of L&T Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of ABB Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of S&S Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of BHEL Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Beeco Lawrie Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Stelmec Make
Supply,installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Southern Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Alsthom make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Easun Reyroll Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Vijay Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Sudhir Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Electric Field Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Crompton Greeves Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Allind Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Pascal Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of L&T Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of ABB Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of S&S Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of BHEL Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Beeco Lawrie Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Stelmec Make
Installation,testing,commissioning of Closing coils (36V) by way of Replacement of Damaged/Burnt Out Closing coil of same composition, type, make already installed in 11kV VCB panel of Southern Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Alsthom make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Easun Reyroll Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Vijay Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Sudhir Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Electric Field Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Crompton Greeves Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Allind Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Pascal Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of L&T Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of ABB Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of S&S Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of BHEL Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Beeco Lawrie Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Stelmec Make
Supply, Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Southern Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Alsthom make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Easun Reyroll Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Vijay Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Sudhir Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Electric Field Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Crompton Greeves Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Allind Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Pascal Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of L&T Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of ABB Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of S&S Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of BHEL Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Beeco Lawrie Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Stelmec Make
Installation,testing and commissioning of 11KV Vacuum Interruptor Housing Assembly by way of Replacement of Damaged/Burnt Out one of same composition,type,make already installed in 11kV VCB panel of Southern Make
Providing and fixing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps,Transformer Clamps(Both H.V & L.V Side),Pad Clamps)
Fixing of clamps (Bi-Metallic) confirming to IS: 1285 standards ( for 33KV P.T Clamps,C.T clamps,Transformer Clamps(Both H.V & L.V Side),Pad Clamps)
Providing and fixing of 33KV Post Insulators by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type)
Fixing of 33KV Post Insulators by way of replacement of damaged one confirming to IEC 61109/92-93 with latest amendments (porceline type)
Providing and fixing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type)
Fixing of 33K VCB Bushes complete assembly by way of replacement of damaged one confirming to IS:2099 standard (porceline type)
Providing and fixing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damaged one confirming to IS:2099 standards (porceline type)
Fixing of 33KV HV Bushes of power transformers complete assembly by way of replacement of damaged one confirming to IS:2099 standards (porceline type)
Providing and fixing of 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type)
Fixing of 11KV LV Bushes of transformers complete assembly by way of replacement of damaged one confirming to IS: 2099 standards (porceline type)
Supply,installation,testing and commissioning of 33KV C.T(3-core) confirming to IEC:185 and IS:2705 (part-1 to 4) standards of ratio 300-150/5-5-5A/ 250-125/5-5-5A) outdoor type
Fixing,installation,testing and commissioning of fresh 33KV CT (3-core) of different ratio confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be provided by the department) outdoor type
Supply, installation,testing and commissioning of 33KV P.T of (110V/√3) confirming to IS:3156 (part-I to Part-III) outdoor type
Fixing,installation,testing and commissioning of fresh 33KV PT (110V/√3) confirming to IEC:185 and IS:2705 (part-1 to 4) standards by way of replacement of damaged one (material to be supplied by the department) outdoor type
Providing and fixing of 33KV isolator 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards with earthing blade
Providing and fixing of 33KV isolator 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards without earthing blade
Fixing,installation,testing and commissioning of fresh 33KV isolators 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (material to be supplied by the department) (with earthing blade / without earthing blade)
Providing, Installation,Testing and commissioning of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damaged one heavy duty 600amps.
Installation,Testing and commissioning of 33KV link set (610x50x6mm male copper balde and female part 200X50x3mm ) by way of replacement of damaged one heavy duty 600amps. (material to be supplied by the department)
Providing,Installation,Testing and commissioning of 11KV G.O Set 600 Amps (with earthing blade) heavy duty conforming to latest version of IS - 9921 (part-I to V) with earthing blade by way of replacement of damaged one
Installation,Testing and commissioning of 11KV G.O Set 800 Amps heavy duty conforming to latest version of IS - 9921 (part-I to V) (material to be supplied by the department)
Providing, fixing, installation, testing and commissioning of 11KV Isolators,630amps. conforming to IS 9921/IEC-129 standards with earthing blade
Providing, fixing, installation, testing and commissioning of 11KV Isolators,630amps. conforming to IS 9921/IEC-129 standards without earthing blade
Installation,Testing and commissioning of 11KV Isolators,630amps. conforming to IS 9921/IEC-129 standards (with earthing blade/without earthing blade ) (material to be supplied by the department)
Providing, Installation,Testing and commissioning of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damaged one heavy duty 600amps.
Installation,Testing and commissioning of 11KV link set (400x50x6mm male copper balde and female part 100X50x3mm ) by way of replacement of damaged one heavy duty 600amps. (material to be supplied by the department)
Providing and fixing of 33KV Drop out set with porcelaine insulator by way of replacement of damaged one as per latest IS standard with latest amendments therof.
Installation,Testing and commissioning of 33KV D.O. set by way of replacement of damaged one as per latest IS standard with latest amendments therof.(material to be supplied by the department)
Providing, Installation,Testing and commissioning of 33KV L.A. set (porcelaine type with clamps) by way of replacement of damaged one as per latest IS standard with latest amendments therof.
Installation,Testing and commissioning of 33KV L.A. set by way of replacement of damaged one as per latest IS standard with latest amendments therof. (material to be supplied by the department)
Oil Toping in 33/11 KV Power Transfromers and 33KV MOCB's (Transformer oil to be supplied by the department)
Providing,installation, testing and commissioning of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers
Installation, testing and commissioning of Winding Temperature meter by way of replacement of damaged one suitable for 33/11 KV, 10MVA/6.3MVA/5.0MVA Power Transformers
Providing,installation, testing and commissioning of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV , 10MVA/6.3MVA/5.0MVA Power Transformers
Installation, testing and commissioning of Oil Temperature meter by way of replacement of damaged one suitable for 33/11 KV , 10MVA/6.3MVA/5.0MVA Power Transformers
Providing and fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one 33KV side
Fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one 33KV side
Providing and fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one 11KV side
Fixing of Bush Rods suitable for 33/11KV Power Transformer (10MVA/6.3MA/5.0MVA) by way of replacement of damaged one 11KV side
Supply ,installation,testing and commissioning of 30V,200 AH Maintenance free Battery Bank ( comprising of 15 number batteries of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards of Exide/HBL/AMAR Raja or equivalent make
Installation,testing and commissioning of 30V,200 AH Maintenance free Battery Bank ( comprising of 15 number batteries of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards of Exide/HBL/AMAR Raja or equivalent make
Supply,installation,testing and commissioning of automatic 30V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA
Installation,testing and commissioning of automatic 30V,DC,15amp. (constant current constant voltage ) fully automatic battery charger float cum boost type 2KVA
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,630mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,400mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,300mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,240mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,185mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,150mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,120mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,630mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,400mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,300mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,240mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,185mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,150mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,120mm^² 3-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,630mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,400mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,300mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,240mm^²1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,185mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,150mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 11KV (E) grade armoured ,120mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,630mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,400mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,300mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,240mm^²1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,185mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,150mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Laying,Testing,commissioning of 11KV (E) grade armoured ,120mm^² 1-core,Xlpe FRLS Power Cable (with stranded compact circular aluminium with extruded semi conducting compound,Xlpe insulated and overall PVC sheathed cable confirming to IS:7089 (Part-II)-1985 with the latest amendments by way of replacing the damaged cable of 11KV switchgear (havells or Glastor or finolex make)
Supply,laying,Testing,commissioning of 2Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Supply,laying,Testing,commissioning of 4Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Supply,laying,Testing,commissioning of 6Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Supply,laying,Testing,commissioning of 8Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Supply,laying,Testing,commissioning of 12Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Laying,Testing,commissioning of 2Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Laying,Testing,commissioning of 4Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Laying,Testing,commissioning of 6Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Laying,Testing,commissioning of 8Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Laying,Testing,commissioning of 12Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS conforming to IS:1554(Part 1),IS 8130,IS ;5831 (Havells or Gloster or finolex make )
Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 630mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 400mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 300mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make) suitable for
Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 240mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 185mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 150mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 120mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 630mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV Xlpe 400mm^²,3-core Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 300mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 240mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 185mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 150mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV ,3 core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 120mm^²,3-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 630mm^²,3-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 400mm^²,3-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 300mm^²,3-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 240mm^²,3-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 185mm^²,3-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 150mm^²,3-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 120mm^²,3-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 630mm^²,3-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 400mm^²,3-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 300mm^²,3-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 240mm^²,3-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 185mm^²,3-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 150mm^²,3-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 120mm^²,3-core Xlpe Power Cable
Supply,installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 630mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 400mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 300mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 240mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 185mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 150mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply,installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 120mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 630mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 400mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 300mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 240mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 185mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 150mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Installation,testing,commissioning of 11KV , 1core heat shrinkable straight through jointing cable kit(outdoor Type) suitable for already installed 11KV 120mm^²,1-core Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or RAYCHEM make)
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 630mm^²,1-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 400mm^²,1-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 300mm^²,1-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 240mm^²,1-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 185mm^²,1-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 150mm^²,1-core Xlpe Power Cable
Supply, Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 120mm^²,1-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 630mm^²,1-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 400mm^²,1-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 300mm^²,1-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 240mm^²,1-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 185mm^²,1-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 150mm^²,1-core Xlpe Power Cable
Installation,Testing and commissioning of 11KV cable termination kits (Indoor/ outdoor Type) 3M or Raychem suitable for 120mm^²,1-core Xlpe Power Cable
Loading of 10 MVA Power Transformer to the sub station bed / platform i/c manual dragging, rotation etc (if any required) (Complete Job)
Loading of 6.3 MVA Power Transformer to the sub station bed / platform i/c manual dragging, rotation etc (if any required) (Complete Job)
Loading of 5MVA Power Transformer to the sub station bed / platform i/c manual dragging, rotation etc (if any required) (Complete Job)
Unloading of 10 MVA Power Transformer from the sub station bed / platform i/c manual dragging, rotation etc (if any required) (Complete Job)
Unloading of 6.3 MVA Power Transformer from the sub station bed / platform i/c manual dragging, rotation etc (if any required) (Complete Job)
Unloading of 5 MVA Power Transformer from the sub station bed / platform i/c manual dragging, rotation etc (if any required) (Complete Job)
Carriage of 10 MVA Power Transformer upto 5km
Carriage of 6.3 MVA Power Transformer upto 5km
Carriage of 5 MVA Power Transformer upto 5km
Carriage of Power Transformer (10/6.3/5 MVA) beyond 5km upto 10km
Carriage of Power Transformer (10/6.3/5 MVA) beyond 10km upto 20km
Carriage of Power Transformer (10/6.3/5 MVA) beyond 20km
Unloading of material which are to be handled with care like 33KV CT / 33KV PT etc including manual carriage from dumping site upto proper stacking
Loading of of material which are to be handled with care like 33KV CT / 33KV PT etc including manual carriage stacking site upto loading
Manual Carriage of materials like 33KV CT / 33KV PT 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc upto first 100mtr lead
Manual Carriage of materials like 33KV CT / 33KV PT 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc For every additional 50mtr or part there off
Unloading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage from dumping site upto proper stacking
Loading of bulky material which are to be handled with care like 33KV C&R panel , 33KV VCB panel , 11KV VCB panel etc including manual carriage stacking site upto loading
Supply ,installation,testing and commissioning of copper Bus Bar (2ftx10mm)
Installation,testing and commissioning of copper Bus Bar (2ftx10mm)
Installation, testing & commissioning of 10 MVA Power Transformer ( including assembly viz fixing of bushes, radiators, fans (if any), thermometer, wiring of instruments etc. ) Complete Job
Installation, testing & commissioning of 6.3MVA Power Transformer ( including assembly viz fixing of bushes, radiators, fans (if any), thermometer, wiring of instruments etc. ) Complete Job
Installation, testing & commissioning of 5MVA Power Transformer ( including assembly viz fixing of bushes, radiators, fans (if any), thermometer, wiring of instruments etc. ) Complete Job
Complete Dismantelling of 10MVA Power Transformer (including assembly viz fixing of bushes, radiators, fans etc)
Complete Dismantelling of 6.3MVA Power Transformer (including assembly viz fixing of bushes, radiators, fans etc)
Complete Dismantelling of 5MVA Power Transformer ( including assembly viz fixing of bushes, radiators, fans etc)
Repairing of Re-Setting Links of 11 KV VCB Panel
Repairing of operating shaft of 11 KV VCB Panel
Repairing of Shower Contact of 11 KV VCB Panel
Repairing of Isolating Sockets of 11 KV VCB Panel
Repairing of High Tension Spring of 11 KV VCB Panel
Repairing of Tripping Shaft of 11 KV VCB Panel
Repairing of Rollers of 11 KV VCB Panel
Repairing of Latch Assembly of 11 KV VCB Panel
Repairing of Gear Assembly of 11 KV VCB Panel
Repairing of Tripping Mechanism of 11 KV VCB Panel
Repairing of Spring Charge Motor Assembly of 11 KV VCB Panel
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Alsthom make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Easun Reyroll Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Vijay Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Sudhir Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Electric Field Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Crompton Greeves Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Allind Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Pascal Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of L&T Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of ABB Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of S&S Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of BHEL Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Beeco Lawrie Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Stelmec Make
Repairing of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Southern Make
Replacement of Re-Setting Links of 11 KV VCB Panel
Replacement of operating shaft of 11 KV VCB Panel
Replacement of Shower Contact of 11 KV VCB Panel
Replacement of Isolating Sockets of 11 KV VCB Panel
Replacement of High Tension Spring of 11 KV VCB Panel
Replacement of Tripping Shaft of 11 KV VCB Panel
Replacement of Rollers of 11 KV VCB Panel
Replacement of Latch Assembly of 11 KV VCB Panel
Replacement of Gear Assembly of 11 KV VCB Panel
Replacement of Tripping Mechanism of 11 KV VCB Panel
Replacement of Spring Charge Motor Assembly of 11 KV VCB Panel
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Alsthom make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Easun Reyroll Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Vijay Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Sudhir Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Electric Field Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Crompton Greeves Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Allind Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Pascal Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of L&T Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of ABB Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of S&S Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of BHEL Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Beeco Lawrie Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Stelmec Make
Replacement of BMR Mechanism Complete suitable for of 11 KV VCB Panel of Southern Make
Deco Spray Painting
Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Voltmeter 11KV/110V
Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Ammeter
Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- LED panel Indicators
Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Push Button
Supply, Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- HRC fuse with Base -16 Amps
Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Voltmeter 11KV/110V
Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Ammeter
Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- LED panel Indicators
Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- Push Button
Installation, Testing and Commissioning of 11 KV Panel equipments/items by way of replacement of damaged one- HRC fuse with Base -16 Amps
Panel Control re-wiring with 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc
Supply,installation,testing and commissioning of Auxilary Relay -30 A by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Installation,testing and commissioning of Auxilary Relay -30 A by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Supply,installation,testing and commissioning of Auxilary Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Installation,testing and commissioning of Auxilary Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Supply,installation,testing and commissioning of TNC Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Installation,testing and commissioning of TNC Switch by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Supply,installation,testing and commissioning of Trip Circuit Supervision Relay by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Installation,testing and commissioning of Trip Circuit Supervision Relay by way of Replacement of Damaged/Burnt of type,make and class already installed in panel.
Supply,installation,testing and commissioning of Numerical/Digital Relay by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in panel.All relays shall conform to the requirements of IS:3231/IEC-60255 and IEC-61850 of (MIT113 ER / Ashida 141A) Operating Voltage 30-36Volts
Fixing , testing and commissioning of Numerical/Digital Relay (MIT113 / Ashida 141A) by way of Replacement of Damaged/Burnt of same ratio(A.C &D.C),type,make and class already installed in 11KV VCB panel.(material to be provieded by the department)
Providing and fixing of Arcing interrupting chambers suitable for 33 KV VCB panels of different makes by way of replacement of damaged one
Fixing of Arcing interrupting chambers suitable for 33 KV VCB panels of different makes by way of replacement of damaged one
Supply,installation,testing and commissioning of master trip relay 24-50 V by way of Replacement of Damaged/Burnt of ,type,make and class already installed in 11KV VCB panel
Installation,testing and commissioning of master trip relay 24-50 V by way of Replacement of Damaged/Burnt of same type,make and class already installed in 11KV VCB panel
Supply,installation,testing and commissioning of Yard lights by way of Replacement of Damaged/Burnt of type already installed
Installation,testing and commissioning of Yard lights by way of Replacement of Damaged/Burnt of type already installed
Note: The material utilized/works executed shall be stritctly as per REC Standards with Latest amendments there off.
M/S ENGINEERS ASSOCIATES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .