| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC | ₹42.2 L Quoted ₹43.5 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹43.6 L+₹7,493.42 (0.17%)Rejected-Finance | ₹43.6 L+₹7,493.42 (0.17%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹45.4 L+₹1.9 L (4.31%)Rejected-Finance | ₹45.4 L+₹1.9 L (4.31%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹46.4 L+₹2.9 L (6.70%)Rejected-Finance | ₹46.4 L+₹2.9 L (6.70%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹49.9 L+₹6.4 L (14.8%)Rejected-Finance | ₹49.9 L+₹6.4 L (14.8%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
12 Dec 2023, 6:00 pmClosed
GE NORTH BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
REPAIR REPLACEMENT MAINTENANCE OF WATER SUPPLY SWIMMING POOL PUMP SET AND OVER HEAD SUMP UNDER AOR OF AGE BR NORTH OF GE NORTH BANGALORE
2023_MES_627763_1
8422
Open Tender
Electrical and Maintenance Works
Item Rate
BANGALORE
Class D Category a(ii)
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH BANGALORE
₹98,000
Yes
23 Jan 2024
9 Nov 2023
19 Dec 2023
9 Nov 2023
12 Dec 2023
29 Nov 2023
9 Nov 2023 - 29 Nov 2023
Amount
Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5m depth and getting out in hard / dense soil for laying of pipe lines.
Returning, refilling in incl spreading, levelling watering and well ramming in layers not exceeding 25 cm thick with any type of soil all as directed
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified as directed.
Taking up CI/DI water mains (including all fittings), with spigot and socket ends and lead joints/Titan Joints for the following size :- 150 mm bore
All as per item No. 4 above but for 100 mm bore
All as per item No. 4 above but for 80 mm bore
S&F DI pipe line type K-7 flanged / spigot and socket, in any length laid in trenches. Note :- (i) Cost of DI specials shall be measured and paid separetely. 150 mm bore
All as per item No. 7 above but for 100 mm bore
All as per item No. 7 above but for 80 mm bore
Cutting of DI/CI pipe in position for insertion of CI/DI specials of following sizes;- 150 mm bore
All as per item No. 10 above but for 100 mm bore
All as per item No. 10 above but for 80 mm bore
M&L for DI Specials like bends, tapers, tee pieces all sockets, all spigot, collars, caps & plugs any size & shape as ordered by Engineer- in- charge incl testing complete as specified & directed for the following sizes:- Up to 150 mm bore
M&L Run lead joint for water mains of the following size of CI pipes :- 150mm
All as per item No. 14 above but for 100mm
All as per item No. 14 above but for 80mm Note:- Excavation and earth work shall be measured and paid separately
Dismantaling the sluice valves in various location and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts, gland packing etc and refixing after repairs of the following sizes:- 200 mm dia bore
All as per item No. 17 above but for 150 mm dia bore
All as per item No. 17 above but for 100 mm dia bore
All as per item No. 17 above but for 80 mm dia bore
M&L for repacking stuffing box of sluice valve spindle including taking apart and reassembling of following sizes:- 150 mm bore
All as per item No. 21 above but for 100 mm bore
All as per item No. 21 above but for 80 mm bore
Taking up the GI pipes with fittings and connected control gate valves/ Sluice valve/non return valve/foot valve etc. from sump/ trenches/ floors/roof for the following size:- . 15 mm dia
All as per item No. 24 above but for 20mm dia
All as per item No. 24 above but for 25mm dia
All as per item No. 24 above but for 40mm dia
All as per item No. 24 above but for 50mm dia
All as per item No. 24 above but for 80mm dia
All as per item No. 24 above but for 100mm dia
All as per item No. 24 above but for 150mm dia
S& F GI water tubing medium grade with all fitting (flanged/socket/union/tee etc) laid in trenches/walls/floors/roof of following sizes :- 15 mm dia
All as per item No. 32 above but for 20mm dia
All as per item No. 32 above but for 25mm dia
All as per item No. 32 above but for 40mm dia
All as per item No. 32 above but for 50mm dia
All as per item No. 32 above but for 80mm dia
All as per item No. 32 above but for 100mm dia
All as per item No. 32 above but for 150mm dia
Supplying laying and testing 25mm outer dia 3 - layer PP-R Polypropylene random copolymer) pipes SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches / wall / floors complete all as per manufacture's instruction and as directed by Engineer-in-Charge. Make : SFMC/ WETFLOW / SAFE (Manufactured by poineer) 25 mm outer dia
Supply & fixing in replacement of the following size gun metal Gate valve with iron wheel :- 15 mm dia
All as per item No. 41 above but for 20 mm dia
All as per item No. 41 above but for 25 mm dia
All as per item No. 41 above but for 40 mm dia
All as per item No. 41 above but for 50 mm dia
All as per item No. 41 above but for 65 mm dia
Dismantling Old valve pit complete with deteriorated MS cover and Construction of new brick masonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement complete all as directed by Engr-in-charge.
Dismantling Old valve pit complete with deteriorated MS cover and Construction of new brick masonry valve pit chamber of inner dimension 150x150x100 cms suitable for sluice valves upto 150 mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement complete all as directed by Engr-in-charge.
Dismantling Old valve pit complete with deteriorated MS cover and Construction of new brick masonry valve pit chamber of inner dimension 200x225x115 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement complete all as directed by Engr-in-charge.
Dismantling Old valve pit complete with deteriorated MS cover and Construction of new brick masonry valve pit chamber of inner dimension 200x250x115 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in CM 1:6, rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement complete all as directed by Engr-in-charge.
S & F in replacement sluice valve both side flanged and ISI marked (IS-780) of sluice valve cast iron body with S/S spindle and brass fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt, washers and rubber insertion packing 6mm thick etc of following sizes:- 150 mm dia bore
All as per item No. 51 above but for 100 mm dia bore
All as per item No. 51 above but for 80 mm dia bore
All as per item No. 51 above but for 200 mm dia bore
Removing of unserviceable foot valve from tank and replacement with new CI foot valve of following sizes:- 150 mm dia bore
All as per item No. 55 above but for 100 mm dia bore
All as per item No. 55 above but for 80 mm dia bore
All as per item No. 55 above but for 50 mm dia bore
Removing old unserviceable float valve from service tank and supply and fix new float valve with PVC body aluminium float rod, nylon float high presure type for the following size:- 20 mm bore
All as per item No. 59 above but for 25 mm bore
Taking out old unserviceable foot valve from UG sump and removing unserviceable leather from suction line and replacement of the same with high quality leather including nuts, bolts, washer etc and servicing for the following sizes:-. 150 mm dia bore
All as per item No. 61 above but for 100 mm bore
All as per item No. 61 above but for 80 mm bore
S&F in replacement Voltmeter (0-500 V), Ammeter (0-400A) (Make Meco) & indication lamps
S&F in replacement Electronic Timers ST 100 operating range of 160V to 500V make L & T cat No. ST80328OOOO/ST80329OOOO as required
Supply & laying in replacement of flat Copper cable of following sizes:- 3 core 2.5 Sqmm
All as per item No. 66 above but for 3 core 4 Sqmm
All as per item No. 66 above but for 3 core 6 Sqmm
Taking out the existing unsv LT panel & supply & fixing of new accessories like starter single phase preventor, fuse cut outs, indicating lamp etc suitable for 5 HP, submersible pump set for outdoor application. Note :- Job includes necessary civil works such as foundation, grounding of panel etc & connecting back existing old cables.
S&F in replacement of non return valve flanged and threaded type including complete fixing accessories like nuts, bolts, packing etc of following sizes:- 100 mm dia bore
All as per item No. 70 above but for 80 mm dia bore
All as per item No. 70 above but for 63/65 mm dia bore
Supply and installation with testing complete of digital water level indication device operating on single phase supply direct display in 19 mm size (letter display) digit system in meter/CM of water of overhead tank ensuring alarm while water fall or rise over predetermined limits with the following description complete all as specified and as directed by Engineer-in-charge including dismantling old unserviceable water level indicator. (a) The entire unit must operate through a compact electronic circuit which must ensure reliable operation at 230V +10% at 50 Hz +5%, with reliable in display and alarm at low and high level head tank. (b) One circuit must be housed in high impact polystyrne molded box nylon mlded connection strips. The level system must resistance transducer, while unattested by corrosion and other contents avilable in water the product must be controlled by Micro switch. (c) The whole unit must electronically contolled and the upper level and lower level indications must be in two parts. Each complete part must be fitted in MS CRS sheet box separetaly.
M&L for testing 04/05 core copper conductor PVC insulated heavy duty unsheathed cable 1100 volts grade 0.5 Sqmm from control box to display meter in ducts/on ground/through existing pipes etc including taking out unserviceable flexible cable all as specified and as directed.
M&L in replacement of Mechnical joints with rubber washer, nuts and bolts as existing at site of the following sizes of CI/DI pipes :- 200 mm bore
All as per item No. 75 above but for 150 mm bore
All as per item No. 75 above but for 100 mm bore
All as per item No. 75 above but for 80 mm bore
Replacement of Air release valve of existing size suitable for centrifugal pump set complete all as specified and as directed.
Repairs / Maintenance of centrifugal / monoblock pumpsets regularly / systematically including inspection, adjustment repairs by opening the pump set for carrying out the preventive maintenance and repair by checking the serviceability alignment of various spares, removing the unserviceable pump spares and replacing with new spare parts, components servicing, cleaning and overhauling the same by lubricating, replacement of gasket, refixing the same after servicing, testing the same for smooth running, replacing minor parts like Gland rope, bolts & nuts, packing, threading and replacing spares and matching inclusive etc all as specified and as directed by Engr-in-charge of the following capacities pump sets. Note : New spares other than minor spares shall be measured and paid separately. 15 to 25 HP any model & make at Gunatha vihar Pump house
All as per item No. 80 above but for 5 to 12.5 HP any model & make at CQAL & DIQA Pump house
Disconnecting the electric cable from the terminal box of upto 5HP motor, disconnecting the motor from them pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop and performing following works as specified and directed by Engr-in-Charge. (i) Dismantling the motor and taking out the burnt copper winding /fiber strip/insulating materials and worn out ball bearing - 2 Nos (ii) Clean the stator slots by CTC solution and rewind on stator slots with super enamelled copper wire of existing gauge with insulating materials/fiber strip/varnishing and made terminal connection of fiber glass coated wire. (iii) Replacement of ball bearing - 2 Nos (iv) Assembling the motor and painting with two coat of primer and one coat of synthetic enamel paint including marking flow of water and MES NO all as per norms and all as specified and as directed as directed by the engr-in-charge. (v) Transporting to the motor to the site refixing on foundation channel with new bolts and nuts, coupling the pump and motor with correct alignment apply grease and connecting electrical connections testing complete alll as directed and specified by the Engr-in-charge
All as per item No. 82 but Disconnecting the electric cable from the terminal box of 10 to 15HP motor, disconnecting the motor from them pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop as specified and directed by Engr-in-Charge
All as per item No. 82 but Disconnecting the electric cable from the terminal box of 25HP motor ,disconnecting the motor from them pump, remove the motor from the foundation bed and taking out the motor and transporting to authorised work shop as specified and directed by Engr-in-Charge
Scraping the old paint by using wire brush and emery paper and preparation of the surface for painting the following pumpset's /control panel /suction and delivery pipe of the pump house with one coat of primer and two coat of synthetic enamel paint all as specified and directed at site of the following capacity including marking flow of water and MES NO all as per norms and all as specified and as directed. 15 to 25 HP Pump set
All as per item No. 85 above but for 5 HP Pump set
Disconnect the electrical connection,Lifting the submersible pumpset with 50mm GI pipe from 500 to 700 feet depth bore well up to 7.5 HP capacity and dismantling the pump set and rewinding the submerssible motor with super enamelled copper wire of suitable gauge replacing the damaged impeller, bearing , bushes, stainer as per exisiting size and assembiling the same including necessary lathe works, fixing the motor and proper insulation, connecting and testing with applying one coat of primer and two coat of synthetic enamel paint and lowering the same and testing and commissioning all as directed at specified by the Engr-in-charge
Disconnect the electrical connection,Lifting the submersible pumpset with 50mm GI pipe from 500 to 700 feet depth bore well 10 to 15 HP capacity and dismantling the pump set and rewinding the submerssible motor with super enamelled copper wire of suitable gauge replacing the damaged impeller, bearing , bushes, stainer as per exisiting size and assembiling the same including necessary lathe works, fixing the motor and proper insulation, connecting and testing with applying one coat of primer and two coat of synthetic enamel paint and lowering the same and testing and commissioning all as directed at specified by the Engr-in-charge. Note : for items Nos 89 & 90 : Quoted rates is inclusive of necessary to and for transporation of pumpset to workshop.
Removing the defective single phase preventer from star/delta starter and supply and fixing new single phase preventer suitable for various capacity of motors 5/7.5 /15/25 HP(Make : L&T or equivalent)
Taking down carefully electric driven centrifugal / Monoblock pump 5 to 25 HP from foundation/ MS channel after disconnecting suction/ delivery lines/main electric supply from motor starter panel for replacement of ball bearing -02 Nos as per existing size at site / nearest repairing workshop including bring back and reassembling the same complete all as directed by Engr-in-charge.
Taking down carefully electric driven Motor 5 to 25 HP from foundation/ MS channel after disconnecting suction/ delivery lines/main electric supply from motor starter panel for replacement of ball bearing -02 Nos as per existing size at site / nearest repairing workshop including bring back and reassembling the same complete all as directed by Engr-in-charge.
Repair the star/delta starter fully automatic starter including replacing with new spares ie. Contactor, timer, relays etc suitable for existing make and capacirty of ML1/ML2/ML3/ML4/ML1.5/MK1. Note : Spares shall be measured and paid separately.
Supply only starter contactor of ML 1.5 Type Make L & T Cat No. SS91851 or its equivalent approved make
Supply only starter contactor of ML 2 W Type Make L & T Cat No. CS96005LOOO or its equivalent approved make
Supply only starter relay of ML 2 /3Type Make L & T Cat No. SS91859OOCO/ SS91859OOEO or its equivalent approved make
Supply only standard operating coil for ML 1.5 Type Make L & T Cat No. SS90873POOO or its equivalent approved make
Taking out the existing unsv submersible panel, supply & fixing of new accessories like starter single phase preventor, fuse cut outs, indicating lamp, coil, terminal block etc suitable for 5/7.5 HP, submersible pump set for outdoor application. Note :- Job includes necessary civil works such as foundation, grounding of panel etc & connecting back existing old cables.
S&F in replacement of Electronic Timers ST 100 operating range of 160V to 500V make L & T cat No. ST80328OOOO / ST80329OOOO or its equivalent approved make
Dismantling the existing old pressure gauge from the pump set/water supply line and provision of new pressure guage 1-10.6 kg per sq cm 100 mm dia dial 3/8" threaded type with stop cock arrangement.
S&F new pump shaft as per existing size of the following capacity pump sets 10 to 25 HP Pump set
All as per item No. 100 above but for Up to 7.5 HP Pump Set
S&F new rubber with CI coupling set suitable for 15 to 25 HP for centrifugal pumping set including key, lock, stud etc complete all accessories.
S&F in replacement of GI pipe heavy duty 50 mm dia with heavy duty socket.
Dismantling the existing old Vacuum gauge from the pump set/water supply line and provision of new pressure guage 0-760 mm Hg pressure 100 mm dia dial 3/8" threaded type with stop cock arrangement.
S&F in replacement of LED indication lamps from Lt panels of colours Red, Green and Yellow.
Dismantaling the old shaft and performing the necessary work and remetalling the shaft as per existing size of the following capacity pump sets Less than / Equal to 7.5 HP Pump Set
Preparing the surface and applying One coat of painting with approved synthetic enamel paint to external surface of pipes of sizes 200mm/150mm/100mm/80mm/50mm dia and marking arrows indicating direct flow with approved enamel paint all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of Voltmeter (0-500 V) / Ammeter (0-400A) with suitable capacity of CTs. (Make Meco/AE).
M&L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the UG sump suitable to store potable drinking water incl one coat white washing inside and marking outside sump in visible place the capacity of sump, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following sumps:- Capacity of 5000 gallons at CQAL
All as per item No. 109 above but for Capacity of 30000 gallons at AFSOD
All as per item No. 109 above but for Capacity of 33000 gallons at AFSOD
All as per item No. 109 above but for Capacity of 15000 gallons at DIQA
All as per item No. 109 above but for Capacity of 100000 gallons at DGQA Res Accn (Guatha vihar)
M&L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the OH reservoir of any staging suitable to store potable drinking water incl one coat white washing inside and marking out side sump in visible place the capacity of Tank, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following overhead reservoirs including staging:- Capacity of 1000 gallons at CQAL
All as per item No. 114 above but for Capacity of 100000 gallons at DGQA Res Accn (Guatha vihar)
All as per item No. 114 above but for Capacity of 30000 gallons at AFSOD
All as per item No. 114 above but for Capacity of 33000 gallons at AFSOD
Supply and installed avaiation lights of LED Based all as specified and directed by Engr-in-Charge.
Maintenance of swimming pool 18 lakh ltrs capacity at MEG and Centre including maintenance of water parameters all as per IS 3328 : 1993, quality tolerances of water suitable for swimming pools complete all as specified and directed by Engineer In charge along with the following specifications shall be maintened while executing the work :- (i) pH Value : 7.5-8.5 (ii) Total Alkalinity as CaCO3 mg/L : 50-500 (iii) Total Residual Chlorine as Cl2 mg/L a) At inlet Max : 0.5 b) At outlet Min : 0.2 (iv) Oxygen absorbed in 4 hrs at 27 deg C mg/L Max : 1 (v) Total Dissolved solids mg/L : 1500 (vi) Chlorides as Cl mg/L : 500 (vii) Total Iron as Fe mg/L : 0.1 (viii) Heavy metals as Pb mg/L Max : 0.1 (ix) Colour Hazen units Max : 10 (x) Turbidity NTU Max : 10 (xi) Odour Less (xii) Palatable Taste (xiii) Standard Plate count cfu/ml shall not be more than 100/ml (xiv) Total coliforms MPN/100ml Max : 10/100ml
All as per Sl Item No. 119 above but capacity of swimming pool 8 lakh ltrs (PRTC). NOTE FOR SL ITEM NO. 121 and 122 :- (i) Rate is deemed to be inclusive of all necessary chemicals / cleaning agents, chlorine granules (90%), alum, copper sulphate, soda ash, bleaching powder etc., of approved make. (ii) Pump operator will be provided by the department. (iii) Rate also deemed to be inclusive of weekly water sample test of above parameters from Government approved NABL recognised lab. (iv) If any blockage occurred in the suction/ delivery pipe / back wash pipe , the contrcator has to recify the blockage / obstruction and the rate of the same shall be included in the quoted rate. (iv) Register for daily consupmption of chemicals such as calcum hypo, alum, soda ash, bleaching powder, copper sulphate to be maintained by the contractor & initials of Engr in Charge/User to be endorsed regularly.
M&L for Cleaning the swimming pool of capacity 18 lakhs ltrs once in a week all around and bottom of pool to remove the algae, by means of scrapping/ scrubbing the walls with wire brush, removing the sediments deposited at bottom with the help of suction sweeper complete all as specified and directed.
M&L for Cleaning the swimming pool of capacity 8 Lakh Litres once in a week all around and bottom of pool to remove the algae, by means of scrapping/ scrubbing the walls with wire brush, removing the sediments deposited at bottom with the help of suction sweeper complete all as specified and directed. NOTE FOR SL ITEM No 121 & 122:- (i) suction sweeper required for the cleaning will be provided by the department, but replacement of sweeper brush and minor repairs/gernal services rates of will be deemed in the quoted rate. (ii) Rate quoted shall be deemed to be inclusive of all necessary chemicals /cleaning agents etc.
Servicing pressure filter of capacity 90000 LPH by opening pressure filter and taking down filter media of different sizes approximately (10000 Kg) carefully, opening the strainer and reset the same after replacement of filter media cleaning filter nozzles with pressure water, refill the filter bed with fresh media and cleaning the pebbles/ 20 mm/10mm /40 mm/2 mm topping up the short fall with new media, servicing the backwash system, replacing the u/s pressure gauge, testing & commissioning all as specified and as directed.
Servicing pressure filter of capacity 60000 LPH by opening pressure filter and taking down filter media of different sizes approximately (7000 Kg) carefully, opening the strainer and reset the same after replacement of filter media cleaning filter nozzles with pressure water, refill the filter bed with fresh media and cleaning the pebbles 20 mm/10mm /40 mm/2 mm topping up the short fall with new media, servicing the backwash system, testing & commissioning all as specified and as directed.
M&L for Cleaning balancing tank of swimming pool of capacity 50000 ltrs complete with:- (i) Cleaning the balancing tank with high pressure water jet to remove all masses, algae and dirt (ii) Taking out dirt and sludge with sludge machine and disposing the same to a safe distance. (iii) Scrubbing the internal walls/floor with industrial vacuum cleaner. (iv) Applying anti bacterial sterilization to walls and floor of balancing tank.
Supply in replacement for PVC hose pipe 50 mm dia.
Removing the UNSV motor starter by disconnecting incoming / outgoing supply and S&F DOL motor starter MK1 type suitable for 10 HP motor. Make-L&T Cat No DOL SS96211 or its equivalent
Removing the old / damaged fully automatic motor starter by disconnecting incoming/ outgoing supply and S&F new fully automatic motor starter ML 1.5 FASD type suitable for 10 HP motor. Make-L&T Cat No SS91856POAO or its equivalent
Repairing the existing un serviceable star delta starter, fully automatic by dismantling / opening of the starter, check the faulty spares / wiring, removing the un serviceable spares and fixing only of the new spares including re fixing of the star delta starter and electrical connections to motor testing etc., complete all as specified and as directed. NOTE :- Spares shall be measured and paid separately.
S R CONSTRUCTIONS
SHRI NARAYANADRI ENGINEERS & BUILDERS
DIVYA CONSTRUCTIONS
V.R.Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .