| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹42.9 CrAccepted-AOC | ₹42.9 Cr | L-1 | Accepted-AOC L-1 Bidder. |
| 2 | L-2₹43.3 CrRejected-Finance | ₹43.3 Cr | L-2 | Rejected-Finance Rejected. Other than L-1. |
| 3 | L-3₹43.5 CrRejected-Finance | ₹43.5 Cr | L-3 | Rejected-Finance Rejected. Other than L-1. |
| 4 | L-4₹43.8 CrRejected-Finance | ₹43.8 Cr | L-4 | Rejected-Finance Rejected. Other than L-1. |
| 5 | L-5₹44.7 CrRejected-Finance 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹44.7 Cr | L-5 | Rejected-Finance Rejected. Other than L-1. |
Tender Value
₹49 Cr
EMD Value
₹15 L
Closing Date
6 Nov 2024, 6:00 pmClosed
CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
PROVN OF OTM ACCN FOR CERTAIN UNIT (PH-II OF TWO PHASES) AT SEVOKE ROAD MILITARY STATION UNDER GE (P) SILIGURI
2024_MES_669057_1
98778/SEV/SZ/E8
Open Tender
Civil Works
900 days
SEVOKE ROAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (P) SILIGURI
₹15 L
Yes
HQ CE SILIGURI ZONE
19 Dec 2024
31 Aug 2024
13 Nov 2024
31 Aug 2024
6 Nov 2024
30 Oct 2024
31 Aug 2024 - 5 Sept 2024
7 Sept 2024
Amount
BUILDINGS & STRUCTURE (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 33,16,47,400.00 inserted by the MES in Schedule ‘A’ Part-I.
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 64,30,700.33 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 46,308.98 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 19,15,221.29 inserted by the MES in Schedule ‘A’ Part-IV.
ROAD, PATH, CULVERT & HARDSTANDING (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,25,05,631.14 inserted by the MES in Schedule ‘A’ Part-V.
SEWAGE DISPOSAL (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,26,543.27 inserted by the MES in Schedule ‘A’ Part-VI.
AREA DRAINAGE (Sch 'A' Part-VII)
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 52,89,865.01 inserted by the MES in Schedule ‘A’ Part-VII.
SECURITY WALL AND CHAIN LINK FENCING (Sch 'A' PART-VIII)
Lump sum price worked out by the Contractor for “(SECURITY WALL AND CHAIN LINK FENCING )” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,42,82,835.94 inserted by the MES in Schedule ‘A’ Part-VIII.
EXTERNAL WATER SUPPLY (Sch 'A' PART-IX)
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,74,190.06 inserted by the MES in Schedule ‘A’ Part-IX.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-X)
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 45,78,222.62 inserted by the MES in Schedule ‘A’ Part-X.
FIRE FIGHTING (Sch 'A' PART-XI)
Lump sum price worked out by the Contractor for “FIRE FIGHTING” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,16,84,330.77 inserted by the MES in Schedule ‘A’ Part-XI.
FIRE ALARM (Sch 'A' PART-XII)
Lump sum price worked out by the Contractor for “FIRE ALARM” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 24,28,744.00 inserted by the MES in Schedule ‘A’ Part-XII.
LIGHTNING PROTECTION (Sch 'A' PART-XIII)
Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 16,25,813.10 inserted by the MES in Schedule ‘A’ Part-XIII.
DG SET (Sch 'A' PART-XIV)
Lump sum price worked out by the Contractor for “DG SET” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,21,166.40 inserted by the MES in Schedule ‘A’ Part-XIV.
SUMMER APPLIANCES (Sch 'A' PART-XV)
Lump sum price worked out by the Contractor for “SUMMER APPLIANCES” as listed in Schedule ‘A’ Part-XV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 86,820.78 inserted by the MES in Schedule ‘A’ Part-XV.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XVI)
SITE CLEARANCE AND SITE DEVELOPMENT Bringing approved Earth or RBM (River Bed Materials) may be mixed with granules / pebbles not exceeding 40 mm size (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any, transportation, taxes if any etc. complete all as specified and directed. NOTE :- (a) Earth or River Bed Materials required for the item shall be supplied by contractor from outside of MOD land at any lead, at his own arrangement. (b) All cost of procurement of earth including cost of transportation, compaction royalties, tax etc shall be deemed to be included in the unit rate quoted by the contractor. (c) Forming embankments / filling in low lying areas including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering ramming / rolling and finishing of required size, shape etc not exceeding 1.5 m high from base / natural ground level. (d) With reference to Clause 3.6 of MES Schedule Part-II on Serial Page No. 21, it is clarified that measurement of the above item shall be of finished embankment / traverse of filled earth after consolidation / compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk. (e) Total quantity / partial quantity of earth may not be available in Sevoke Area. The contractor shall bring the earth outside area and it is advised to quote the rate considering available of soil and its lead involved.
INTERNAL WATER SUPPLY S&F two way bib cock with wall flange quarter turn (low-flow) 16 mm dia complete all as specified and directed.
S&F Wall Mixer with provision for Overhead Shower with 115 mm Long Bend pipe on upper side, connecting legs & wall flanges complete all as specified and directed.
S&F Central Hole Basin Mixer without Popup Waste System with 450 mm Long Braided Hoses complete all as specified and directed.
INTERNAL ELECTRIFICATION Supplying and fixing of Modular type RJ-11 telephone socket outlet in the modular metal flush box and cover plate including concealed 25 mm PVC conduit in wall/ceiling/fixed to roof, connections etc complete all as specified and directed.
Fabrication, supply & fixing of GI pipe bracket up to 32 mm dia 0.9m long & 2 set of clamps made out of 30x5mm MS flat & fixed with anchor bolt suitable for mounting 1x35W LED security light fitting and painting complete all as specified and directed.
S & F 50W, highbay light with electronic driver and other connected accessories, IP 65 including connecting up with twin core twisted flexible copper conductor cable of suitable size including provision of metal chain upto 1.5 metre length, 230V, 50Hz complete all as specified and directed.
S & F 80W, highbay light with electronic driver and other connected accessories, IP 66, with system efficacy upto 150 lm/w, 10KV SPD, toughened glass round highbay in PDC housing including connecting up with twin core twisted flexible copper conductor cable of suitable size including provision of metal chain upto 1.5 metre length, 230V, 50Hz complete all as specified and directed.
S & F 100W, highbay light with electronic driver and other connected accessories, IP 66, with system efficacy upto 150 lm/w, 10KV SPD, toughened glass round highbay in PDC housing including connecting up with twin core twisted flexible copper conductor cable of suitable size including provision of metal chain upto 1.5 metre length, 230V, 50Hz complete all as specified and directed.
ROAD, PATH, CULVERT & HARDSTANDING M&L for 3.00 mm thick painting to road surfaces as in lines, dashes, arrows, letters, zebra cross etc, on roads, pavements and the like etc with thermoplastic road marking paint (not exceeding 10 cm wide) @ 5 Kg/Sqmm and applying glass grit @300 gms/sqm over painted surfaces while the painting surfaces are hot including cleaning surfaces complete all as specified and directed. NOTE : Painting to road surface shall be carried out through mechanical application by the approved applicator of manufacturers instruction.
M&L for 150 mm (OD) DWCPE (SN-8) pipes with all fittings and laid in trenches and jointed complete all as specified and directed.
SUMMER APPLIANCES S&F for voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity of 2KVA complete all as specified and directed.
FIRE FIGHTING & EXTERNAL WATER SUPPLY Supply and laying ductile iron (DI) pressure pipe S/S, class K-9, confirming to IS: 455:1989, laid in trenches under floor/ walls/ columns etc of bore size 150mm, including rubber gasket push on joints complete all as specified and directed.
Supply and laying ductile iron (DI) pressure pipe S/S, class K-9, confirming to IS: 455:1989, laid in trenches under floor/ walls/ columns etc of bore size 100mm, including rubber gasket push on joints complete all as specified and directed.
S&F for ductile fitting/flange/SS/bend/reducer for 80 to 200 mm dia of different size complete all as specified and directed.
M&L for construction of brick masonary valve pit of internal dimensions 900mm x 900mm x 1000mm complete and fabrication of 3.0 mm thick MS sheet cover and angle iron frame made out of 40mm x 40mm x 6mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as specified and directed.
M&L for construction of brick masonary valve pit of internal dimensions 1000mm x 1000mm x 1000mm complete and fabrication of 3.0 mm thick MS sheet cover and angle iron frame made out of 40mm x 40mm x 6mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as specified and directed.
M&L for construction of brick masonary valve pit of internal dimensions 600mm x 600mm x 1000mm complete and fabrication of 3.0 mm thick MS sheet cover and angle iron frame made out of 40mm x 40mm x 6mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as specified and directed.
S&F for ABC type dry powder extinguisher of capacity 6kg as per IS:2171 consisting of welded MS cylindrical body, with discharge valve, nozzle and CO2 cartridge and hanging arrangement complete all as specified and directed.
S&F for CO2 fire extinguisher consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS:934 finished externally with red enamel paint and fixed to wall with brackets with wall plug/dash fasteners complete with internal charge capacity 4.5 Kg ISI marked 4.5 litres capacity complete all as specified and directed.
S&F Fire extinguisher water stored pressure type 9.0 Ltr capacity BIS standard complete all as specified and directed.
S&F Fire Bucket 9.0 Ltr made of iron with high functionality, able to withstand very high temperature with ring handle complete all as specified and directed.
S&F auto-illuminated (glow-in-dark) exit sign board with red colour background with appropriate symbol, made up of acrylic sheet for fire escape in minimum 10cm x 30 cm size to be pasted on wall with high quality adhesive or to be hanged with ss hook-chain system complete all as specified and directed.
Supply and fixing rechargeable type ceiling/wall mounted Escape lighting showing exit sign in green colour provided with in-built battery suitable to provide minimum 90 min continuous lighting after power cut complete all as specified and directed.
FIRE ALARM Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sqmm, 2 core, 1100 volts grade complete all as specified and directed.
S&F for UPS for 30 min back up power, single phase AC input 160 to 260 V and out put 230 + 1% of capacity 1 KVA complete all as specified and directed.
DG SET Supply install testing and commissioning Silent type built in within an acoustic enclosure Diesel Engine driven Generating set water cooled including AMF panel for standby power supply 415 volts, 3 Phase, 4 wire, 50 cycles / sec,0.8 power factor, 125 KVA (100 KW) or next higher standard size available KVA,1500 RPM. Self excited self regulated brushless AC generator installed. The alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter 24 volt. Acoustic enclosure suitable for ambient condition at Siliguri area and confirming to condition under IS 10002, 13364 Part I 1992, BS 5514/5000 to meet exhaust emission test as per revised MoEF norms/as per CPCB-IV Plus or as per latest. Fuel tank capacity not less than 08 hours fuel requirement & battery as recommended by OEM battery leads, sound proof canopy etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based gen-set controller governor with the following under-mentioned features & all as specified & directed NOTE : The capacity of Generator set shall be net after all due derating factors as per relevant IS/BS Standards design. Item Continued as Srl No. 16.32 to 16.43
(A) Alternator :- Standard design alternator rated at 125 KVA/ nearest higher available capacity at 0.8 (lag) power factor AC, 3 - phase 4 - wire, 415 volts, 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS: 13364 Part I (1992) and shall be in position to generate supply with frequency regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. (i) Insulation class - 'H' (ii) Temperature rise Class - 'H' (iii) Excitation : Self Excited (iv) Regulation performance: The voltage is kept constant with + 1%. (v) Frequency regulation + 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete, with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- (i) Fly wheel with housing (ii) Cooling system :- Moulded radiator with fan & belts. (iii) Cooling Water pump : - Centrifugal type belt driven.
(iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade. MS Exhaust pipe with bends/flanges and all accessories to be supplied and erected as per OEM recommendation. The Exhaust Pipe shall be insulated with low resin bounded wool of min 75 mm thickness min 144 Kg/m density. The dia/thickness and Stack height of the Exhaust pipe shall be as per OEM recommendation and CPCB norms. The minimum height of Stack to be provided with each generator set shall be worked out as per CPCB norms. Turbo charger type Exhaust manifold Silencer : Residential type
(v) Fuel System :- Diesel Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/ (as recommended by OEM) for 1% speed /frequency regulation. Comprising with Fuel Filters and Fuel Hoses. (vi) Lub oil System :- Comprising of Lubricating oil filter, Lubricating oil pump etc. (vii) Air Intake System :- Air intake Manifold, Air cleaner dry type etc (viii) Governer Electronic type (ix) Starting System :- Electric Self starter with and including battery charging alternator 24 Volts DC. (x) Batteries :- Batteries of maintenance free of capacity 12 V, 180 AH- 02 Nos complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified.
Start and stop push button Ignition key / Switch Radiator with blower fan & first fill of coolant oil Corrosion inhibitor coolant (xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. (xii) Safety Controls : - Engine low lube oil pressure, high water temperature and over speeding of engine. (xiii) Coupling arrangement : - Flexible coupling
(xiv) Accessories :- AVM Pads built- in or separately mounted to manufactrer base frames. (xv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes as per manufacturer. (xvi) Fuel Tank :- Daily service fuel tank made complete on a common base inside the acoustic enclosure as per manufacturer guidelines for min 8 hrs continuous operation. (xvii) MS/Steel flexible pipe line to and from the fuel tank to the DG Set. (xviii) Battery Charger shall be provided as per manufacturer guidelines (xix) The DG Set shall comply to the emission limits requirement as per Govt of India, The DG Set shall be complied with all test requirements as stipulated in the gazette notification. All relevant test results from NABL accredited lab shall be produced.
(b) Digital Volt meter with slector switch of 0 to 500 volts - 1 Set (c) Digital Frequency meter - 1 No (d) Digital KW meter - 1 No (e) Digital KWH meter panel mounted type - 1 No (f) Digital PF meter - 1 No (g) Annuciation with indication lamps for : (i) Low lub oil pressure. (ii) High Water Temparature. (iii) Engine over speed. (iv) Battery low voltage. (v) Over voltage, under voltage and over current (vi) Display shall be alphanumeric LCD display with LED backlight.
Controls and Records:- (a) Load on Indication (b) Load off indication (c) Engine start push button (d) Engine stop push button (e) Fault accept / reset push button (f) Battery Charger shall be provided as per manufacturer guidelines (g) Suitable to provide a record of most recent fault conditions & fault history. (h) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA , frequency etc. (j) Complete engine data viz, starting battery voltage, engine temp, engine runnning hours, engine oil pressure etc. (k) Control incl provn of service adjustment & calibration of DG control functions.
(D) Civil Works :- All civil works including PCC platform and related foundations including for panel and equipments including making good of distrubed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the manufacturer. Note:- The contractor shall arrange for artificial load for testing of DG Set at site and the cost is deemed to be included in the above offer. (E) Acoustic Enclosure:- Manufactured by OEM suitable for 125 KVA DG Set. (i) Tested by NABL approved lab as per CPCB-IV Plus or as per latest. (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating set battery should be inside the enclosure.
(iv) Fuel tank should be inside the enclosure, however, the fuel storage shall be enough for 8 hrs continuous operation. If required contractor may arrange outside fuel storage capacity to achieve this (v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick (c) Sound Insulation :- 100 mm thick rock wool (minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level (vi) The acoustic should be composite in construction and fully assembled integral unit. (vii) The DG Set should be provided with external Emergency stop push button. (viii) The enclosure should be suitably internally illuminated by CFL/FTL Lamp fittings. (ix) The noise level should be 75 dB at 1m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade.
Supply, installation, testing and commissioning out door type LT feeder pillar box of suitable size, pedastal mounted, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and aluminium busbar wrapped with PVC tape/sleeves and maintained the colour code and aluminium strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 50 x 50 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (Main DG panel) Item Continued as Srl No. 16.45 to 16.46
Supply, installation, testing and commissioning out door type LT feeder pillar box of suitable size, pedastal mounted, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and aluminium busbar wrapped with PVC tape/sleeves and maintained the colour code and aluminium strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 50 x 50 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- ( DG Panel-1) Item Continued as Srl No. 16.48 to 16.49
Supply, installation, testing and commissioning out door type LT feeder pillar box of suitable size, pedastal mounted, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and aluminium busbar wrapped with PVC tape/sleeves and maintained the colour code and aluminium strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 50 x 50 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- ( DG panel-2) Item Continued as Srl No. 16.51 to 16.52
Supply, installation, testing and commissioning out door type LT feeder pillar box of suitable size, pedastal mounted, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and aluminium busbar wrapped with PVC tape/sleeves and maintained the colour code and aluminium strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 50 x 50 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- ( Fire panel at Pocket-2) Item Continued as Srl No. 16.54 to 16.55
EXTERNAL ELECTRIFICATION Supply, install pre fabricated outdoor compact secondary sub station, (CSS) with distribution transformer, high voltage switch gear, low voltage switch gear/control gear and corresponding interconnections (Cable flexible, bus bar) connection between RMU & transformer shall be using 3 nos 1Cx 95 sq mm aluminium unarmoured (E) XLPE cable and connection from transformer to LT panel shall be by CU busbar and auxiliary equipments in enclosed common encloser assembly of enclosure made out from sheet steel tropicalized to local weather conditions raised platform (1.2M height) incl foundation all as specified or directed shall be consisting of the following (a) HT switch gear (manufactured as per refrence standerd (IEC 62271-(1,100,102,105,200) IEC-1, IEC 60529) 11 KV 630 Amps 21 KA for 3 sec. SF6 insulated Non-extensible compact switch gear consisting of one numers motorised load breck switch & one no motorised vaccum circuit breaker in SF6 insulated stainless steel enclosure with self -powered series trip microproseeor base numerical over current short circuit & earth fault relay (IDMTL+Inst) for protection in VCB and fault passage indicator in LBS. CSS shall be supplied from OEM only and make of RMU, VI & CSS shall be same. (CSS-1) (b) RMU panel-(1 load break switch (LBS) 1 Vacuum circuit braker (VCB) + CU busbar) BIL 28/75 kV, LBS function type:- 3 position disconnector and earthing switch equipped with seprate drive unit. Item Continued as Srl No. 16.57 to 16.62
1. Operation of LBS- Motorised 2. Cable switch rating-12 KV, 630A,21 KA/3 sec. 3. cable busing rating-630A 4. Cable cover : as per standered 5.Fixed type capacitive voltage indication-provided 6. ON/OFF/Earth switch via MIMIC-provided 7. Bottom cable termination- suitable up to 1 No. x3Cx150 sq mm 8. LBS should have fault oassage indicator 9. compatiable for SCADA based remote monitoring and operation facility. (c) VCB FUNCTION Type:- 3 position disconnector and earthing switch equipped with separate drive unit. VCB equipped with O/C, S/C, E/F time release for transformer protection. 1.Vacuum circuit breaker 12 kV, 630 A, 21 KA/3 Sec
2. Opertaion of breaker- motorised 3. Self powered electronic numerical protection relay providing over-current, short circuit & earth fault protection with ring core protection current transformers. 4. Capacitive voltage indication fixed type. 5.ON,OFF, EARTH indication on the front mimic of the panel. 6.Cable box for termination of cable up to 3 nos. x1Cx 95 sqmm/120 sq mm. 7. cable cover standered 8. Emergency trip push button. 9. Shunt trip coil-230 V AC 10. Multifunction meter with RS485 port and associated metering CTs (3/4 line display with import/ Export Energy meatures.) 11. Compatible for SCADA based remote monitoring and operation facility. 12. The cable compartment of ring main unit shall be internal arc tested for 21 kA for 1 Sec.
(d) RMU accessories: 1. Manual operating handle 2.Manometer with remote contacts for SF6 gas pressure indication. (e) Transformer: ( Manufactured as per refrence standered IS 11171, IS 2026-Part I to V, IEC 60076-11& IEC 60076-12) Type: Cast Resin dry type AN cooling Transformer 1. Ratio-11kV/0.415 kV, 2. Capacity: 250 KVA 3. No of phase: 3 & frequency: 50 Hz. 4.Vector group: dyn 11. ( 11 KV side delta, 0.415 KV side star.) 5. Off load tap Changer links. 6. Class of insulation: F 7. 50 % load losses : 1430 W ( Sub to IS tol.) 100 % load losses : 4100 W ( Sub to IS Tol.)
8. Percentage Imp: 4.5% 9. Winding material: Copper (f) Transformer Accessories: 1. Winding temperature indicator (g) LT panel ( Incomer) : 1000 Amps rated aluminium busbar for three phase and neutral with PVC sleeves supported on insulators-04 Nos 1. ACB 630Amps, 50KA, 4 Poles,rated operational voltage 415-690 volt , Manual draw out (MDO) type microproceesor relese with LSIG protection unit with over current, short circuit and earth fault protection with LCD display with the manual setting nobs & current measurement on screen and battery back up with over temperature protection and indication for protection unit,shunt trip, under voltage release Terminals,dedicated slots for releases in built Temperature Protection ,Ics=Icu=Icw rated impulse withstand voltage 12 KV-01 No.
2. ON/OFF/TRIP lamps 3. MCCBs shall have the feasibility of SCADA based remote monitoring & operation facility. (j) ENCLOSURE for CSS: 1.Outdoor type 2 mm thick galvanised enclosure shall have IP 54 degree protection for HT & LT switchgear compartment & IP 23 D degree of protection for Transformer compartment. The enclosure exterior shall be powder coated with PP based paint. HT & LT compartment will be provided with cover. The compartment illumination lamp with door operated switch shall be provided for HT and LT compartment. Note: Lifting (Bucket) (k) EARTHING: Internal earthing connection by using 50 x 6 aluminium strips
Supply, install pre fabricated outdoor compact secondary sub station, (CSS) with distribution transformer, high voltage switch gear, low voltage switch gear/control gear and corresponding interconnections (Cable flexible, bus bar) connection between RMU & transformer shall be using 3 nos 1Cx 95 sq mm aluminium unarmoured (E) XLPE cable and connection from transformer to LT panel shall be by CU busbar and auxiliary equipments in enclosed common encloser assembly of enclosure made out from sheet steel tropicalized to local weather conditions raised platform (1.2M height) incl foundation all as specified or directed shall be consisting of the following (a) HT switch gear (manufactured as per refrence standerd (IEC 62271-(1,100,102,105,200) IEC-1, IEC 60529) 11 KV 250 Amps 21 KA for 3 sec. SF6 insulated Non-extensible compact switch gear consisting of one numers motorised load breck switch & one no motorised vaccum circuit breaker in SF6 insulated stainless steel enclosure with self -powered series trip microproseeor base numerical over current short circuit & earth fault relay (IDMTL+Inst) for protection in VCB and fault passage indicator in LBS. CSS shall be supplied from OEM only and make of RMU, VI & CSS shall be same.(CSS-2) Item Continued as Srl No. 16.64 to 16.68
(b) RMU panel- (1 load break switch (LBS) 1 Vacuum circuit braker (VCB) + CU busbar) BIL 28/75 kV, LBS function type:- 3 position disconnector and earthing switch equipped with seprate drive unit. 1. Operation of LBS- Motorised 2. Cable switch rating-12 KV, 250A,21 KA/3 sec. 3. cable busing rating-250A 4. Cable cover : as per standered 5.Fixed type capacitive voltage indication-provided 6. ON/OFF/Earth switch via MIMIC-provided 7. Bottom cable termination- suitable up to 1 No. x3Cx95 sq mm 8. LBS should have fault passage indicator 9. compatiable for SCADA based remote monitoring and operation facility.
(c) VCB FUNCTION Type:- 3 position disconnector and earthing switch equipped with separate drive unit. VCB equipped with O/C, S/C, E/F time release for transformer protection. 1.Vacuum circuit breaker 12 kV, 250 A, 21 KA/3 Sec 2. Opertaion of breaker- motorised 3. Self powered electronic numerical protection relay providing over-current, short circuit & earth fault protection with ring core protection current transformers. 4. Capacitive voltage indication fixed type. 5.ON,OFF, EARTH indication on the front mimic of the panel. 6.Cable box for termination of cable up to 3 nos. x1Cx 95 sqmm/120 sq mm. 7. cable cover standered 8. Emergency trip push button.
9. Shunt trip coil-230 V AC 10. Multifunction meter with RS485 port and associated metering CTs (3/4 line display with import/ Export Energy meatures.) 11. Compatible for SCADA based remote monitoring and operation facility. 12. The cable compartment of ring main unit shall be internal arc tested for 21 kA for 1 Sec. (d) RMU accessories: 1. Manual operating handle 2.Manometer with remote contacts for SF6 gas pressure indication. (e) Transformer: ( Manufactured as per refrence standered IS 11171, IS 2026-Part I to V, IEC 60076-11& IEC 60076-12) Type: Cast Resin dry type AN cooling Transformer 1. Ratio-11kV/0.415 kV, 2. Capacity: 100 KVA 3. No of phase: 3 & frequency: 50 Hz. 4.Vector group: dyn 11. ( 11 KV side delta, 0.415 KV side star.) 5. Off load tap Changer links.
(h) Outgoing 1. MCCB FP, 200 Amps rating, Ics=100%Icu, 25 kA breaking capacity, adjustable thermal magnetic release - 02 Nos ( 1 No for fire panel & 1 No Spare , (ii) MCB SPN 32 Amps, 10 kA -02, (iii) MCB SPN 10 Amps,10 kA -5 Nos. 2. ON/OFF/TRIP lamps 3. MCCBs shall have the feasibility of SCADA based remote monitoring & operation facility. (j) ENCLOSURE for CSS 1.Outdoor type 2 mm thick galvanised enclosure shall have IP 54 degree protection for HT & LT switchgear compartment & IP 23 D degree of protection for Transformer compartment. The enclosure exterior shall be powder coated with PP based paint. HT & LT compartment will be provided with cover. The compartment illumination lamp with door operated switch shall be provided for HT and LT compartment. Note: Lifting (Bucket) (k) EARTHING Internal earthing connection by using 50 x 6 aluminium strips
Supply and fixing 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm, with Single type arm bracket 1500 mm long, top dia 70 mm, suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and directed.
Supply,installation, testing and commissioning of out door type LT feeder pillar box of suitable size, pedastal mounted, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and aluminium busbar wrapped with PVC tape/sleeves and maintained the colour code and aluminium strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 50 x 50 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (LT panel-1) Item Continued as Srl No. 16.71 to 16.72
Supply,installation, testing and commissioning of out door type LT feeder pillar box of suitable size, pedastal mounted, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and aluminium busbar wrapped with PVC tape/sleeves and maintained the colour code and aluminium strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 50 x 50 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (LT panel-2) Item Continued as 16.74 to 16.75
Supply,installation, testing and commissioning of out door type LT feeder pillar box of suitable size, pedastal mounted, CPRI type tested, factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof, degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and aluminium busbar wrapped with PVC tape/sleeves and maintained the colour code and aluminium strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing with MS angle iron 50 x 50 x 6 mm and MC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaces having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected, and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be made and comprising with and including following accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 40 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (LT panel-3) Item Continued as Srl No. 16.77 to 16.78
M&L for cable route marker made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint ( HT cable 11/33 KV or LT cable 1100 Volts) on route marker including necessary excavation and earthwork complete all as specified and as directed. NOTE : - (i) The spacing between two consecutive cable route indicators shall not be more than 50 meters & also shall be provided at each & every bend or corner. (ii) PCC will be measured and paid separately
Arun Deo Kumar (BID ID -3158803)
CHHABINDRA KUMAR PRADHAN (BID ID -3158783)
AKM CONSTRUCTION AND ENGINEERING LLP (BID ID -3158075)
NARSINGH DEVELOPERS LLP (BID ID -3158992)
Aalaya Engineering Project Private Limited (BID ID -3155073)
KARMA TSHERING LAMA BHUTIA (BID ID -3158764)
Som Projects Pvt Ltd (BID ID -3158687)
MAHINDER PAL CONSTRUCTIONS PVT LTD (BID ID -3157578)
Hariom Projects Pvt Ltd (BID ID -3158313)
stage.html
html • 0.08 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid