Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.2 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹70.4 L+₹47,936 (0.69%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹74.7 L+₹4.8 L (6.93%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹99.9 L+₹30.0 L (42.9%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L4 | Rejected-Finance Other than being lowest |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
30 Mar 2023, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR MAINT OF VARIOUS DG SETS AND COMPREHENSIVE MAINT CHLORONOME PLANT INCLUDING CONNECTED ACCESSORIES FOR WATER SUPPLY INSTALLATIONS INCLUDING MANNING AND OPERATION AND MAINTENANCE OF COMMAND TARANG SWIMMING POOL UNDER GE NW NAVY NAGAR COLABA MUMB
2023_MES_578853_2
8117/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) Navy Nagar
Class B
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Navy Nagar
₹1.8 L
Yes
15 May 2023
2 Mar 2023
1 Apr 2023
2 Mar 2023
30 Mar 2023
16 Mar 2023
2 Mar 2023 - 13 Mar 2023
Amount
Comprehensive Maintenance of DG Set of Make Cummins/Kirloskar and Capacity 160 KVA at Kanya Pump House, consisting daily, monthly, half yearly and yearly Periodical Routine Maintenance/Checks as per OEM Recommendation, minor repairs and testing of DG set, including under mentioned works complete :- (a) Examine suction and Exhaust Valves and Cleaing if necessary for smooth operation (b) Examine and clean fuel injection, nozzles (c) Check clearance of suction and exhaust valves and adjust if required (d) Changing of Oil filters, Fuel filters, Screen filters assy as and when required (e) Clean Alternator winding in position by forced air and internal surfaces, lubricate DE & NDE bearings as and when required (f) Test IR value of alternator winding and recording the readings (g) Tightining of all nut bolts (h) Greasing wherever is requird (j) Checking of any leakage of fuel & Oil lines (k) Cleaning of fuel tank when due (k) Checking and servicing of Turbo Charger as and when required. Note : (a) Work is including consumables like cotton waste cloth kerosene oil etc. (b) 'B' Check shall be carried out every month (c) Complaints if any shall be attended as and when ordered (through Phone/in writing) by Engineer-in-Charge (d) Major over hauling of Parts and spares will be measured and paid separately) (e) DHPP (N) required at the time of mainteance/ testing will be issued by MES complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 above but 125 KVA capacity at Vidya/Vijaya Pump House complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 above but 125 KVA capacity at Jyestha/Dhanista Pump House complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 above but 125 KVA capacity at Dhanush Pump House complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 above but 250 KVA capacity at MT Section complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 above but 320 KVA capacity at Main Pump House complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 above but 2 x 400 KVA capacity at Central P/H No 1 and Central P/H No 2 House complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement against item No.1 to 7 here in before the following items:-
Fuel filter for DG Sets of Kirloskar for capacity 160 KVA to 250 KVA complete all as specified and directed by Engineer-in-Charge.
Fuel filter for DG Sets of Kirloskar for capacity 125 KVA complete all as specified and directed by Engineer-in-Charge.
Fuel filter for DG Sets of Kirloskar for capacity 75 KVA complete all as specified and directed by Engineer-in-Charge.
Lubrication oil filter element with 'O' ring for DG Set of Kirloskar for capacity 400 KVA complete all as specified and directed by Engineer-in-Charge.
Lubrication oil filter element with 'O' ring for DG Set of Kirloskar for capacity 320 KVA complete all as specified and directed by Engineer-in-Charge.
Lubrication oil filter element with 'O' ring for DG Set of Kirloskar for capacity 125-160 KVA complete all as specified and directed by Engineer-in-Charge.
Air filter element inner and outer with 'O' ring for DG of Kirloskar for capacity 400 KVA complete all as specified and directed by Engineer-in-Charge.
Air filter element inner and outer with 'O' ring for DG Set of Kirloskar for capacity 320 KVA complete all as specified and directed by Engineer-in-Charge.
Air filter element inner and outer with 'O' ring for DG Set of Kirloskar for capacity 125-160 KVA complete all as specified and directed by Engineer-in-Charge.
Lub oil SAE 15 W - 40 (Make : Castrol/Power Supreme or as approved by GE) for Top up or filling up the oil complete all as specified and directed by Engineer-in-Charge.
Distilled water to be filled in batteries complete all as specified and directed by Engineer-in-Charge.
Coolant
Fan Belt for DG Sets of Kirloskar for capacity 400-320 KVA complete all as specified and directed by Engineer-in-Charge.
Fan Belt for DG Sets of Kirloskar for capacity 160 KVA to 250 KVA complete all as specified and directed by Engineer-in-Charge.
Fan Belt for DG Sets of Kirloskar for capacity 125 KVA complete all as specified and directed by Engineer-in-Charge.
Voltmeter 0 to 500 Volts AC complete all as specified and directed by Engineer-in-Charge.
Tachometer/Speedo Meter
Material & labour for Descaling the radiator assembly and inter cooler assembly after disconnecting and dismantling from the engine, cleaning with acid, checking/rectifying any leakage, replacing gaskets, hose pipes, clips, reassemble/refix with the engine, refilling the coolent oil complete for DG Set of Kirloskar for capacity 75 to 160 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repairs battery of Kirloskar for capacity12 V, 150 AH suitable for DG Set complete all as specified and directed by Engineer-in-Charge.
Material & labour for Repairs to 12V battery charging dynamo assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly reaffixing to the engine and testing for satisfactory charging of battery all as directed by Engineer-in-Charge.
Material & labour for Repairs to 12 V self starter assy by removing, dismantling and taking it to authorised workshop and replacing unserviceable armature including field coil tapping, re-fixing to the engine testing for satisfactory function complete all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable AVR from DG Set and Supply and Fixing AVR (Automatic Voltage Regulator) suitable for DG Set of Make Kirloskar/Cummins of Kirloskar for capacity 125 to 400 KVA having input voltage 2 phase + neutral sensing voltage 415, output voltage 95 V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4 A, fast acting and frequency 50 Hz complete all as specified and directed by Engineer-in-Charge. Make: Kirloskar / Cummins or as approved by GE.
Material & labour for Preperation of old painted exposed surface of DG Set, removing all dirt, dust, grease oil etc and Painting exposed surfaces of DG set including accessories fixed with the DG Set, with two coat of synthetic enamel paint of approved colour complete all as specified and directed by Engineer-in-Charge for DG Set of Kirloskar for capacity 320 to 400 KVA.
All as per item No. 14 above but 160 - 180 KVA capacity complete all as specified and directed by Engineer-in-Charge.
All as per item No. 14 above but 75 -125 KVA capacity complete all as specified and directed by Engineer-in-Charge.
Repair/Maintenance to Chlorine dozing system assembly with chlorine injector dozing pump, cleaning, servicing, carrying out minor repairs and testing. (Note : (a) Work is including consumables like cotton waste cloth etc. (b) Parts and spares requied to be replaced shall be measured and paid separately complete all as specified and directed by Engineer-in-Charge.
Supply only in replacement against item No.17 here in before the following items:-
Gear motor 230 volt 50 Hz suitable for decrin dosing pump Part No PM 682 CE complete all as specified and directed by Engineer-in-Charge.
Rotor assembly with bearing brackets and tolerance rings. Part No PMBR PL2 complete all as specified and directed by Engineer-in-Charge.
Coil 250 volt, 50 Hz Part No. MP 6 J222 complete all as specified and directed by Engineer-in-Charge.
Single head feed rate control with shaft. Part No FC 5040D complete all as specified and directed by Engineer-in-Charge.
Pump head (Ferrules 1/4" including duckbill Part No UCPH 7 FD complete all as specified and directed by Engineer-in-Charge.
Roller assembly Part No. MC3ASYD complete all as specified and directed by Engineer-in-Charge.
Pump tube. Part No MCCP 207 complete all as specified and directed by Engineer-in-Charge.
Injection check valve 3/8" Part No MCINJ 38 complete all as specified and directed by Engineer-in-Charge.
Weighted suction line strainer 3/8" Part No. ST 138 complete all as specified and directed by Engineer-in-Charge.
White suction/discharge tube Part No. MAL T002 complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair dosing Pump high pressure single head gear motored adjustable dosing pump with accessories include lead tubing, connecting nuts, injection check valve, clay weight, ferules etc complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair dosing system consisting 40 ltr-100 ltr PE/FRP Tank with PE/FRP Lid & level gauge along with agitator with shaft & blade in plastic tank complete all as specified and directed by Engineer-in-Charge.
Chemical Earthing Set-2 No. of Copper Bonded Rod of diameter 17.2 mm and length of 10 feet UL approved with 25 KA current discharge test from CPRI . The material shall be low carbon high tensile copper bonded rods with 99.9 % of copper on the surface. The UL Approval certificate shall be provided. shall be filled with highly conductive and eco friendly ground enhancing compound as per IEC 62561- 7 shall be not less than 30Kg per pit & Poly pit cover, complete all as specified and directed by Engineer-in-Charge.
Labour only for Cleaning of entire Floor/ Wall Surface area of Command Swimming Pool by brush or Suction Sweeper to avoid development of algae etc, scraping foreign materials and cleaning the entire surfaces of bottom and side walls and remove complete dirt etc, anti-bacterial treatment using chemical disinfectant complete all as directed . (Note : The Cleaning work is in addtion to the daily cleaning of pool work included in the Sch Item No. 23 to 25 above. Cleaning shall be carried out with not less than two labours once in a week or as directed) complete all as specified and directed by Engineer-in-Charge.
All as per item No 22 above but for Tarang Swimming Pool complete all as specified and directed by Engineer-in-Charge.
Supply and lay in replacement Pipes ERW Steel including specials, nominal dia 150 mm, as per IS 3589 (1981) thickness 5.4 mm complete all as specified and directed by Engineer-in-Charge.
All as per item no 24 above but size of pipe 80 mm dia complete all as specified and directed by Engineer-in-Charge.
All as per item no 24 above but size of pipe 200 mm dia thickness complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement butterfly flanged ends, cast iron body flanged and drilled end with nut, long body of class PN 1.6 as per IS 14846 ISI marked including material and labour for joints with rubber or fiber board, bolts and nuts, washers etc complete all as specified for 200 mm dia pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Valves butterfly flanged ends, cast iron body flanged and drilled end with nut, long body of class PN 1.6 as per IS 14846 ISI marked including material and labour for joints with rubber or fiber board, bolts and nuts, washers etc complete all as specified for 150 mm dia pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Valves butterfly flanged ends, cast iron body flanged and drilled end with nut, long body of class PN 1.6 as per IS 14846 ISI marked including material and labour for joints with rubber or fiber board, bolts and nuts, washers etc complete all as specified for 80 mm dia pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement reflux Valve,with by-pass arrangement complete of size 150 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repalcement installing testing and commissioning Trolley mounted self primming , non-clog Trolley mount suction sweeper with pump (i) Trolley mounted suction pump capacity 2 HP self priming pump including rope & starter complete Make : Kirloskar or as approved by GE (ii) Pool cleaner semi type with trolley, 6 Nos of float complete and including PP Rope & vacuum point with ABS material - 10 Nos and piping with 50 mm grade ISI mark, pump with trolley starter, cable etc complete complete all as specified and directed by Engineer-in-Charge.
Material and Labour for construction of valve chamber in repair as per the following description complete all as specified and directed by Engineer-in-Charge.
Foundation in PCC 1:4:8 of size 1.8x1.8x0.15 mtr
Brick walling 230mm thick inside finished size 1.2x 1.2x 1.2 mtr
PCC coping in 1:2:4 on top of walling 100mm thick
MS angle iron frame made out if angle iron 50x50x6mm
MS plate 5mm thick swivel joint with angle iron frame of size 1.10x1.30 including handle of 10mm dia MS round 200mm long and locking arrangement. One rectangular opening 100x150mm duly hinged and welded.
Plaster 10mm thick inside chamber and outside exposed surface above GL.
Painting frame and plate two coats of synthetic enamelled paint red colour over a coat of red oxide primer. Note :- Rates deemed to be included for earth work required as pe site primises.
Disconnecting Power Supply and remove the old unservicable power contactor by opening of nut bolt, washer ,contractor link bar, cable lugs manually replacement of new power contractor of capacity 4 Pole,600 Amp including copper bus bar link of size 30/12 (Vertical) complete all as specified and directed by Engineer-in-Charge.
Replacement of all aluminium bus bar change in Copper bus bar of capacity 800 Amp.including Control wiring as per requirement of Size 1.5 Sqmm to 2.5 Sqmm and bus bar with colour code heat shrink sleave complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Disconnecting motor power cables of various sizes from electrical motor of different capacities and decoupling from the pump sets,removing and taking down carefully and transporting to authorised workshop ,Dismantaling stator and rotor carefully and rewinding stator assembly with supper enamelled copper winding wire of suitable gauge matching to existing gauge and cleaning of slots ,core with carbon tetra chloride solution and apply two coats of insulation varnish and keep stator assembly in heating chamber to improve insulation strength ,reassemble motor completey and transporation to site ,coupling pump to motor and check for proper shaft alignments such that no vibratiobn produce during opertioncoupling to pump with exact allinment ,connect power cables to motor and testing of following capacity motor complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement of copper unamoured power cable of size 25sqmm from motor starter panel to motor in HDPE pipe in ground complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement of copper unamoured power cable of size 35sqmm from motor starter panel to motor in HDPE pipe in ground complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement of copper unamoured power cable of size 50 sqmm from motor starter panel to motor in HDPE pipe in ground complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Disconnecting motor from pump of any Make, model and remove Bearing using bearing puller gear and fix new bearings at DE /NDE including necessary greasing ,check for proper shaft alignments such that no vibratiobn produce during opertion of following capacity Motors complete all as specified and directed by Engineer-in-Charge.
Pump coupled with 15 HP motor (Bearing size 6307 ZZ & 6309ZZ make SFC/NBC/SKF) complete all as specified and directed by Engineer-in-Charge.
Pump coupled with 20 HP motor (Bearing size 6309 ZZ & 6308ZZ make SFC/NBC/SKF) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of MCCB of following capacity including disconnecting the cable, replacement of burntout lugs, spreaders of suitable size including nuts and bolts and fixing to existing panel including necessary alternation to existing busbar and panel all as specfied and directed by Enginner-in-charge.
MCCB of 250 A ,Breaking capacity 36KA,4P with adjustable thermal magnetic setting Ics=Icu=100% complete all as specified and directed by Engineer-in-Charge.
MCCB of 200 A ,Breaking capacity 36KA,4P with adjustable thermal magnetic setting Ics=Icu=100% complete all as specified and directed by Engineer-in-Charge.
MCCB of 125 A,Breaking capacity 16KA,3P fixed type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Pressure gauge 100 mm dia with ball valve of pressure 25 Kg/Sqcm complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repalcement Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finished box complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repalcement PH test kit with coloured ample covered under BTB (range 6.0 to 7.0) or phenol red (range 6.8 to 8.4) with necessary fitments and 100 ml testing solution in Rexene finished box complete all as specified and directed by Engineer-in-Charge.
Supply ,install, test and commissioning in replacement of LT Panel board from CPRI approved panel manufacturer made out of of 2mm CRCA sheet cubical totally enclosed with frame made out of 50mm x 50mm x 6mm angle iron door front and back openable with locking arrangement indoor type vermin and weather proof floor mounting type, suitable for 3 phase 4 wire,50 HZ , 415 Volt AC supply with 800A capacity main copper bus bar (4 Nos) All MCCB shall be connected with suitable size of copper strip from main bus & with terminate point and complete wiring of panel board with suitable size PVC insulated multistranded copper conductor including lugs/thimbles etc suitable Cable alley with for provn of cable entries at bottom with cable glands with soft starter for 75 HP including the following :- (a) MCCB 4 pole, 415V,630Amps 50 KA - 02 Nos (incoming) thermo magnetic adjustable release type,ICS=ICU=100% (b) MCCB 4 pole, 415V,400Amps 36 KA - 03 Nos (Out going) thermo magnetic adjustable release type,ICS=ICU=100% (c) Soft starter minimum switch current 10 mA at 6 V DC for relay outputs, 1.8 A at 230 V AC inductive load, cos phi =0.5 20 ms relay output 1.8 A at 30 V DC inductive load, cos phi = 0.5, Staring current 0.4 1.3 IcI adjustable 3 Nos Analogue output type current output AO : 0-20 mA or 4-20 mA, impedance < 500 = 03 Nos (d) S&F multimeter with suitable CT and PT 0 to 300 Amp and 0 to 500 Volts -04 Nos (e) Phase indicating lamps(RYB)-04 set (f) Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96X96mm-01 set.
Supply and fixing in replacement 150 mm dia ball type foot valve 10/15 Kg/Sqcm model (B-5) of NORMEX (ISI Marked or as approved by GE) including for flanged joint and taking up and down suction pipe, cutting pipe and welding flanges, alteration in sump opening and making good to the disturbed portion of UG sump/wall complete all as specified and directed by Engineer-in-Charge.
Completely Overhauling of Filteration plant having tank capacity 1280mm dia and media depth size 830 mm installed at Tarang swimming pool Opening top cover of filter media and remove all unserviceable material fine sand,filter nozzle,header pipe nozzle and aggegate supply and filled in sequeience layera sand includind painting inside and out side of filteration tank red oxide grey colour functioning of proper filtration plant as per existing complete all as specified and directed by Engineer-in-Charge.
Completely Overhauling of Filteration plant having tank capacity 2200mm dia and media depth size 915 mm installed at Command/ Tarang swimming pool Opening top cover of filter media and remove all unserviceable material fine sand,filter nozzle,header pipe nozzle and aggegate supply and filled in sequeience layera sand includind painting inside and out side of filteration tank red oxide grey colour functioning of proper filtration plant as per existing complete all as specified and directed by Engineer-in-Charge.
Manning and operation of IMSC Pump House by employing one FGM (Skilled) one shift from 0600 Hrs to 1400 Hrs and one FGM (Skilled ) one Shift from 1400 hrs to 2000 Hrs including Sundays and Holidays complete all as specified and directed by Engineer-in-Charge.
Manning and operation of IMSC Pump House by employing one Mate FGM Semi Skilled one shift from 0600 Hrs to 1400 Hrs including Sundays and Holidays complete all as specified and directed by Engineer-in-Charge.
NOTES for Ser No 49.00 & 50.00:- (i) Passes will be processed alongwith (after verification on signed certificate, Pass shall not be granted without submission of qualification proof & experience certificate of FGM and valve man.(ii) Contractor shall submit ID proof, Residential proof, Bank A/C details to department and obtain approval of Engineer-in-Charge before employing a person as Operator (iii) Contractor shall submit the labour licence VAT & copy of GST regn registered number issued by concerned authority.(iv) Working hours of a particular team of workers shall not exceed 08 hrs per day and no workmen shall be allowed to work beyond 08 hrs per day. (v)Duty roster of manpower deployed shall be displayed otherwise recovery of Rs 500/- per day shall be made. (vi)Surprise check will be carried out by department representative and if any employees is not available at his working place, he will be treated as absent and recovery shall be made @ Rs 1500/- per day per person.(vii)Payment as per quoted rate shall also be deducted in addition to the penalty as specified above. (viii) Payment to employees shall be done by crossed cheque through Aadhaar linked bank account only and it shall not be less than minimum fair wages as per act in vogue. The contractor shall submit proof to Engineer-in-Charge before claiming any payment. (ix) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws/ regulations including all relevant taxes as applicable. (x) The rate quoted by the contractor shall be inclusive of life insurance for the tradesmen employed by him in case of untoward incident such as injuries fracture or casualty while on duty. (xi) Contractor shall quote not less than SMFW rates.
Manning & Operation of Command Swimming Pool, consisting of following equipments & Electrical Panel boards etc. by employing one FGM (Skilled) Labours Per Shift of 8 hrs for 2 Shifts, 16 Hrs per day, (0600 Hrs to 1400 Hrs First Shift and 1400 to 2200 Hrs Second Shift) including Sundays & Holidays
Manning & Operation of Command Swimming Pool, consisting of following equipments & Electrical Panel boards etc. by employing one (Valve Man) Labours Per Shift of 8 hrs for 2 Shifts, 16 Hrs per day, (0600 Hrs to 1400 Hrs First Shift and 1400 to 2200 Hrs Second Shift) including Sundays & Holidays
Notes : (i) For Srl No 51.00 and 52.00 (ii) the rate also included cleaning of backwash sump of capacity 1.00 lakh litre every month. (a) Operating Pump sets of any capacity as directed (b) Checking water level in the Swimming Pool. (c) Operating Chlorination/Ionization Plants as directed (d) Maintaining Log Book for Swimming Pool (e) Maintaining record of timing of Swimming Pool operation (f) Operating Sluice/Gate Valves located within 1 KM from the Swimming Pool for Supply of water to pool as per the time schedule/requirement. (g) Routine maintenance & cleaning/back washing of filtration plant. (h) Carrying out necessary measure to achieve quality of swimming pool water as per para 3.1.1 of IS-3228 (1993) such as separating dirt/ dust /suspended particles from water and chlorination of water etc. (Note : Disinfectant chemicals and other consumable chemicals required for Operation and maintenance of Swimming Pool will be measured and paid separately under relevant item of the schedule) A. EQUIPMENTS : (a) (i) Starter Panel - 01 No (b) Vertical type pressure filter capacity 30000 gallons/ hour - 02 Nos (c) Pump set capacity 15 HP - 02 Nos (d) Suction sweeper complete with Accessories and suction hose along with 2 HP pump set - 01 No. (e) Connecting Valves of various type/sizes.
Manning & Operation of Tarang Swimming Pool, consisting of following equipments & Electrical Panel boards etc. by employing one FGM (Skilled) Labours Per Shift of 8 hrs for 2 Shifts, 16 Hrs per day, (0600 Hrs to 1400 Hrs First Shift and 1400 to 2200 Hrs Second Shift) including Sundays & Holidays
Manning & Operation of Tarang Swimming Pool, consisting of following equipments & Electrical Panel boards etc. by employing one (Valve Man) Labours Per Shift of 8 hrs for 2 Shifts, 16 Hrs per day, (0600 Hrs to 1400 Hrs First Shift and 1400 to 2200 Hrs Second Shift) including Sundays & Holidays
(i) For Srl No 53.00 and 54.00 (ii) the rate also included cleaning of backwash sump of capacity 1.00 lakh litre every month. (a) Operating Pump sets of any capacity as directed (b) Checking water level in the Swimming Pool. (c) Operating Chlorination/Ionization Plants as directed (d) Maintaining Log Book for Swimming Pool (e) Maintaining record of timing of Swimming Pool operation (f) Operating Sluice/Gate Valves located within 1 KM from the Swimming Pool for Supply of water to pool as per the time schedule/requirement. (g) Routine maintenance & cleaning/back washing of filtration plant complete all as specified and directed by Engineer-in-Charge. (h) Carrying out necessary measure to achieve quality of swimming pool water as per para 3.1.1 of IS-3228 (1993) such as separating dirt/ dust /suspended particles from water and chlorination of water etc. (Note : Disinfectant chemicals and other consumable chemicals required for Operation and maintenace of Swimming Pool will be measured and paid separately under relevent item of the schedule) A. EQUIPMENTS :- (a) (i) Starter Panel - 01 No (b) Vertical type pressure filter capacity 10000 gallons/ hour - 02 Nos (c) Pump set capacity 10 HP - 02 Nos (d) Suction sweeper complete with Accessories and suction hose along with 3 HP pump set - 01 No. (e) Connecting Valves of various type/sizes.
NOTES for Ser No 49,50,51,52,53,54:- (i) Contractor shall submit ID proof, residential proof, bank A/C details to department and obtain approval of Engineer-in-Charge before employing a person as operator. (ii) Plant operator shall be available as per the shift timings specified in the tender and he will report to JE E/M in-Charge In case of emergency he will function according to their direction. If he is found absent or move without intimating to in-Charge or JE E/M he will be treated as absent for the said shift and recovery of Rs 1500/- per shift shall be affected. (iii) Payment as per quoted rate shall also be deducted in addition to the penalty as specified above. (iv) Contractor shall submit the labour licenece VAT & Copy of GST Regn registered number issued by concerned authority. (v) Payment to employees shall be done by crossed cheque through Aadhaar linked bank account only and it shall not be less than minimum fair wages as per act in vogue. In case payments are made in current coin or currency notes, contractor shall submit certificate alongwith undertaking of employee that asking for payment other than by cheque or by crediting in the bank account of the employee. The contractor shall submit prof to Engineer-in-Charge before claiming any payment. (vi) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (vii) The rate quoted by the contractor shall be inclusive of life insurance for the tradesmen employed by him in case of untoward incident such as injuries fracture or casualty while on duty
Note :- (i) The cost of employment of supervisior and any assitance required to operate and maint the installations by operating staff shall deemed to be included in above offer. (ii) Total 02 Number of Refg/Mech are required to be depolyed to run the installation 16 hours in 2 shifts ( each shift of continuous 8 hours durations). As per industrial act one person should not be continued on duty more than 06 days and he should be given weekly off day for his personel maintenance and one reliver should be employed for off duty by arrangement of contractor without any extra cost to the Govt.The rate quoted includes Oustourcing for operation & maintenance of installation on all days including Sunday/Gazetted Holidays. (iii) The cost of maintenance of documents installations charts and daily records as clarified under relevant particulars specifications shall deemed to be included in the rates quoted for above items. (iv) The location of AC plants to be outsourced are lying inside restricted area and therefore the contractor/operating staff shall comply to all security measures/restrictions imposed by the unit from time to time. (v) The contractor has to arrange the dry/wet bulb thermometer for recording hourly room temperature. (vi) The cost of maintenance of documents installations charts and daily records as clarified under relevent particulars,specification shall deemed to be included in the rates quoted for above items. (vii) The operator on duty should have proper uniform in light blue colour shirt and dark blue trauser duly printed name as MES and contractor with all protective arrangement during the duties like shoes etc and required tools for operation and maintenance of installation.The rate quoted deemed to be inclusive of minor servicing like greasing of bearings, replacment of glands/ rubber coupling, belts etc.Periodical cleaning of cooling tower and AHU filters is contractors responsibility. (viii) The installation will be handed over in operating state on the commencement of contract though work order.
(ix) The contractor shall be solely responsible for all personnel deployed for carrying out the above jobs and all transport required for conveyance. (x) Passes will be processed only after verification of antecedence of deployed employees and submission of verified experience certificate, Pass shall not be granted without submission of qualification proof & experience certificate. (xi) Contractor shall submit ID proof, Residential proof, Bank A/C details to department and obtain approval of Engineer-in-Charge before employing a person as Operator (xii) Payment to employees shall be done by crossed cheque through Aadhaar linked bank account only and it shall not be less than minimum fair wages as per act in vogue. The contractor shall submit proof to Engineer-in-Charge before claiming any payment. (xiii) AC and Installation Operator shall be available as per the shift timings specified in the tender and he will report to JE E/M in-Charge. In case of emergency he will function according to their direction. If he is found absent or move without intimating to in-Charge or JE E/M he will be treated as absent for the said shift and recovery to this effect for Rs 1500/- per shift shall be affected. (xiv) Payment as per quoted rate shall also be deducted in addition to the penalty as specified above. (xv) The individual employed as operator should has minimum qualification of ITI course equivalent from state or central board
(xvi) Contractor shall submit the labour licenece VAT as applicable as per latest laws/acts & Copy of GST Regn registered number issued by concerned authority. (xvii) Contractor has to submit proof of payment of EPF subscription made by him as applicable as per latest laws/acts alongwith RAR failing which RAR will not be progressed for payment. (xviii) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (xix) The bidders are advised not to quote rate less than minimum fair wages as circulated by competent authority. If the quoted amount is less than the estimated cost of work mentioned in BOQ item No 49,50,51,52,53,54, i.e Rs 37,49,339.00, the lowest bidder will have to deposit FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (Cover No 2). The deposited amount shall be the difference between estimated cost mentioned in BOQ item No 49,50,51,52,53,54 (i.e) Rs 37,49,339.00 and amount quoted by lowest bidder. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to withheld the said amount which will be verified by GE. The decision of Accepting Officer regarding amount to be withheld shall be final and binding. The withhold amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall sumbit 03 Nos of BGBs/FDRs of equal amount as mentioned above. The BGBs/FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment/ release as the case may be. (xx) The rates quoted shall be inclusive of suitable reliver wherever sundays & holidays are mentioned for working
AGRAWAL ASSOCIATES
Chakshu Enterprise
Darpan Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .