| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-Finance G 2 BIDHAN NAGAR P O MIDNAPUR P S KOTWALI DIST PASCHIM MEDINIPUR PIN 721101 | MIDNAPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹4.8 L+₹7,641 (1.63%)Rejected-Finance 130 OLD 110 BINAY BABU DHAR RD HINDMOTOR HOOGHLY 712233 | HINDMOTOR | HOOGHLY | WEST BENGAL | 712233 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹4.9 L+₹18,860 (4.02%)Rejected-Finance RAGHUNATHPUR P S JHARGRAM DIST JHARGRAM WEST BENGAL PIN 721507 | JHARGRAM | JHARGRAM | WEST BENGAL | 721507 | L3 | Rejected-Finance 3rd lowest bidder | |
| 4 | Rejected-Technical 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | - | Rejected-Technical Technically Rejected due to 1) Technical Person Agreement Copy Not found 2) Latest GST Return Not found 3) Affidavit X Not submitted in the prescribed format 4) Affidavit Y Not submitted in the prescribed format as per the Notice |
| Sl No | Description | Qty | Unit | DUTTA ELECTRIC WORKS L3 | SUN ENTERPRISE L2 | M/S JOGMAYA ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector (VDS /EN/ UL / FM / ULC approved) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detector sensor with decentralised intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per corresponding standard. (Note : detectors without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) No. of addressable devices in a group will be as per latest recommended Indian/International standards) .(Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / GST/Ravel/Secutron/Honeywell) [NS] | 50 | Mtrs | 3,620 ₹1,81,000 | 3,600 ₹1,80,000 | 3,500 ₹1,75,000 Lowest |
| 2.00 | Supply, Installation,Testing & Commisioning of Analogue Addressable Intelligent Heat Detector (VDS / EN/ UL / FM / ULC approved) (fixed & rate of rise temperature) with twist lockable removal base, built-in fault isolator, etc. including connections as per specifications complete as per NFPA style 7 wiring complete with base and having IP as per corresponding standard (Note : detectors without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) No. of addressable devices in a group will be as per latest recomended Indian/International standards) (Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / GST/Ravel/Secutron/Honeywell) | 10 | Mtrs | 3,700 ₹37,000 | 3,500 ₹35,000 Lowest | 3,500 ₹35,000 Lowest |
| 3.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (VDS / EN / UL / FM / ULC approved) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) (Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / System Sensor/IFC/Secutron/Honeywell) [NS] | 6 | Mtrs | 4,620 ₹27,720 | 4,600 ₹27,600 | 4,500 ₹27,000 Lowest |
| 4.00 | Supply, Installation, Testing & Commissioning of Addressable loop / external powered Hooter (sound output of minimum 90db) cum strobe (strength of light 10cd) complete with inbuilt isolator & IP 42 base (VDS /EN / UL / FM / ULC approved) (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for group of addressable devices.) (Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / GST/Ravel/Secutron/Honeywell) | 2 | Mtrs | 5,200 ₹10,400 | 5,100 ₹10,200 | 5,000 ₹10,000 Lowest |
| 5.00 | Supply, Installation, Testing & Commissioning of LED type Response Indicator (VDS / EN / UL / FM / ULC approved) including connections etc. complete in all respect.(Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / GST/Ravel/Secutron/Honeywell) | 8 | Mtrs | 730 ₹5,840 | 710 ₹5,680 | 700 ₹5,600 Lowest |
| 6.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / KEI / Polycab) with 25mm NB PVC rigid conduit pipe on the surface of the wall. (Make : Precission-Medium/Honeywell)[NS] | 850 | Mtrs | 110 ₹93,500 | 102 ₹86,700 | 100 ₹85,000 Lowest |
| 7.00 | Supply, Installation,Testing & Commisioning of VDS Approved Microprocessor based minimum 6 Loops , fire alarm control panel fully networkable with each loop capable of taking atleast 125 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, provision for external & internal printer (if required),Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, having minimum 1000 event memory, integral SMF lead acid batteries with sealed cells of 24 V / 12 V with integral battery charger complete as required and as per specification.(Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / GST/Ravel/Secutron/Honeywell) | 1 | Mtrs | 1,33,000 ₹1,33,000 | 1,32,061 ₹1,32,061 | 1,32,000 ₹1,32,000 Lowest |
| 8.00NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand. | ||||||
| 8.01TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. | ||||||
| 8.02TERMS & CONDITIONS :- | ||||||
Tender Value
Refer Docs
EMD Value
₹9,415
Closing Date
9 Feb 2026, 2:30 pmClosed
SENIOR SUPERINTENDING ENGINEER
OFFICE OF THE SENIOR SUPERINTENDING ENGINEER (P.W.Dte) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Construction of Single Storied New multipurpose Building with provision of with of (Gplus 2) Storied foundation at ITI Midnapore SITC of FDA System
2026_WBPWD_995655_1
WBPWD/SSE/SWEC/NIQ133/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
PASCHIM MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,415
OFFICE OF THE SENIOR SUPERINTENDING ENGINEER
20 Jul 2026
29 Jan 2026
11 Feb 2026
29 Jan 2026
9 Feb 2026
4 Feb 2026
3 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector (VDS /EN/ UL / FM / ULC approved) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detector sensor with decentralised intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per corresponding standard. (Note : detectors without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) No. of addressable devices in a group will be as per latest recommended Indian/International standards) .(Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / GST/Ravel/Secutron/Honeywell) [NS] | |||||
| 2Supply, Installation,Testing & Commisioning of Analogue Addressable Intelligent Heat Detector (VDS / EN/ UL / FM / ULC approved) (fixed & rate of rise temperature) with twist lockable removal base, built-in fault isolator, etc. including connections as per specifications complete as per NFPA style 7 wiring complete with base and having IP as per corresponding standard (Note : detectors without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) No. of addressable devices in a group will be as per latest recomended Indian/International standards) (Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / GST/Ravel/Secutron/Honeywell) | |||||
| 3Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (VDS / EN / UL / FM / ULC approved) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices.) (Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / System Sensor/IFC/Secutron/Honeywell) [NS] | |||||
| 4Supply, Installation, Testing & Commissioning of Addressable loop / external powered Hooter (sound output of minimum 90db) cum strobe (strength of light 10cd) complete with inbuilt isolator & IP 42 base (VDS /EN / UL / FM / ULC approved) (Note : devices without built-in fault isolator is also acceptable provided the vendor provides one independent fault isolator module for group of addressable devices.) (Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / GST/Ravel/Secutron/Honeywell) | |||||
| 5Supply, Installation, Testing & Commissioning of LED type Response Indicator (VDS / EN / UL / FM / ULC approved) including connections etc. complete in all respect.(Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / GST/Ravel/Secutron/Honeywell) | |||||
| 6Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / KEI / Polycab) with 25mm NB PVC rigid conduit pipe on the surface of the wall. (Make : Precission-Medium/Honeywell)[NS] | |||||
| 7Supply, Installation,Testing & Commisioning of VDS Approved Microprocessor based minimum 6 Loops , fire alarm control panel fully networkable with each loop capable of taking atleast 125 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, provision for external & internal printer (if required),Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, having minimum 1000 event memory, integral SMF lead acid batteries with sealed cells of 24 V / 12 V with integral battery charger complete as required and as per specification.(Approved make : Esser / Cerberus Pro / Secutron Notifer / Edward / Bosch / Apollo / GST/Ravel/Secutron/Honeywell) | |||||
| 8.01 | TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system.
2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. | - | - | - | - |
| 8.02 | TERMS & CONDITIONS :- | - | - | - | - |
| 8.03 | The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 1.82 MB
BOQ_2436524.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .