Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC OFFICE NO 608 6 TH FLOOR 89 91 DURGADEVI DARSHAN BLDG DURGADEVI STREET 4KUMBHARWADA MUMBAI | L1 | Accepted-AOC L1 Bidder | |
| 2 | L1₹4.8 LAccepted-AOC 77 78 EVERGREEN HOUSE 2ND MAIN CHIKKALAXMAIAH LAYOUT DRC POST HOSUR ROAD BANGALORE KARNATAKA 560029 | BENGALURU URBAN | KARNATAKA | 560029 | L1 | Accepted-AOC L1 Bidder | |
| 3 | L1₹5.7 LAccepted-AOC 9 KRISNA KUNJ PLOT NO 148 P K ROAD MULUND WEST MUMBAI 400080 | MUMBAI | MUMBAI | MAHARASHTRA | 400080 | L1 | Accepted-AOC L1 Bidder | |
| 4 | L1₹20.3 LAccepted-AOC 101 BILESHWARPURA NEAR CHATTRAL TAL KALOL DISTT GANDHI NAGAR 382729 GUJARAT | KALOL | GANDHI NAGAR | GUJARAT | 382729 | L1 | Accepted-AOC L1 Bidder | |
| 5 | L1₹61.7 LAccepted-AOC ROOM NO 9 105 RATNA SADAN 2ND PATHAN STREET 5TH KUMBHARWADA MUMBAI MAHARASHTRA 400004 | MUMBAI | MAHARASHTRA | 400004 | L1 | Accepted-AOC L1 Bidder |
Tender Value
Refer Docs
Closing Date
23 Jun 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr. Nilesh Sathe
thyssenKrupp Industrial Solutions (India) Private Limited (Formerly Uhde India Private Limited) Uhde House, L B S Marg, Vikhroli (W), Mumbai - 400083, India
SUPPLY OF PIPE/TUBE- AS (SEAMLESS) FOR P25 PROJECT AT IOCL PANIPAT REFINERY
2022_REFHQ_152108_1
6745-PPM-000-CA-PI32
Limited
Mechanical - Piping, materials, flanges, valves, seals
Supply
120 days
IOCL Panipat Refinery
Please refer Tender documents.
5 documents required · 5 mandatory
Exempted
22 Jan 2025
8 Jun 2022
24 Jun 2022
8 Jun 2022
23 Jun 2022
16 Jun 2022
120 days
SUPPLY OF PIPE/TUBE- AS (SEAMLESS)
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH XS, SEAMLESS, PIPE A335 Gr.P5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH XS, SEAMLESS, PIPE A335 Gr.P5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH XS, SEAMLESS, PIPE A335 Gr.P5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH XS, SEAMLESS, PIPE A335 Gr.P5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH XS, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH XS, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH XS, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH XS, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, BW ENDS,SCH XS, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS (H2 SER.), B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P11, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,SMLS,AS (H2 SER.), B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P11, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,SMLS,AS (H2 SER.), B36.10M, BW ENDS,SCH STD, SEAMLESS, PIPE A335 Gr.P11, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,SMLS,AS (H2 SER.), B36.10M, BW ENDS,SCH XS, SEAMLESS, PIPE A335 Gr.P11, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,SMLS,AS, B36.10M, PE,SCH XS, SEAMLESS, PIPE A335 Gr.P5, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, PE,SCH XS, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS, B36.10M, PE,SCH 160, SEAMLESS, PIPE A335 Gr.P9, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,SMLS,AS (H2 SER.), B36.10M, PE,SCH XS, SEAMLESS, PIPE A335 Gr.P11, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,SMLS,AS (H2 SER.), B36.10M, PE,SCH 160, SEAMLESS, PIPE A335 Gr.P11, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .