Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.1 L+₹4.6 L (23.3%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹34.8 L+₹15.3 L (78.0%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | - | Rejected-Technical Residual work load more than 50 lakhs and ESIC certificate not uploaded | |
| 5 | Rejected-Technical WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | - | Rejected-Technical Residual work load is more than 50 lakhs |
Tender Value
Refer Docs
EMD Value
₹68,560
Closing Date
23 Jul 2021, 6:00 pmClosed
CWE (AF) Palam Delhi Cantt-10
HQ CWE (AF) Palam Delhi Cantt-10
REPAIR MAINT OF HT SWITCHGEAR TRANSFORMERS HT LT CABLES OF CAMERO AREAS UNDER GE (AF) SUBROTO PARK DELHI CANTT-10
2021_MES_449860_2
CA NO CWE/PM/SP-08/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Subroto Park Delhi Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Subroto Park
₹68,560
Yes
30 Sept 2021
28 Jun 2021
26 Jul 2021
28 Jun 2021
23 Jul 2021
8 Jul 2021
Amount
Disconnecting worn out HT connections any size from VCB, cutting worn out leads ( near lugs ), re fixing new Aluminium lugs , cleaning the bus bar chamber with 2-26 CRC solution , insulating with HT tape , connecting the cables with bus bar and testing for smooth functioning complete all as specified and as directed by Engineer-in-Charge.
Repair/servicing of 400/630/800 A 11 KV mechanism/ calibration of HT VCB with highly skilled mechanic specialist in electric HT breakers line, by taking out trolley, decarborizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/smooth contact, tightening of all connections, checking of alignment for easy moving of breaker, checking of ON/OFF operation with setting of buffer gap adjustment, inspecting the wiring of IDMT relays contact travel contact alignments, roller gap, hard or light setting of breaker greasing of all moving mechanism complete, all as specified and directed by Engineer-in-Charge. Note ; Carlibration will be carried out by auth contractor / Tech and test certificate will be kept on record.
S & F in replacement of following spares of VCB complete including required necessary spares :-
Geared motor 230V AC/DC
Closed Coil 24/110V DC
Close Latch
Trip Latch
Interrupter Housing
Vaccume Interrupter - 800A, 13.1 KA
P.T. 11 KV/110 V-100 VA
Disconnecting worn out HT connections any size from HT RMU, cutting worn out leads ( near lugs ), re fixing new Aluminium lugs, cleaning the insulator and post of cable conector with 2-26 CRC solution , insulating with HT tape , connecting the cables with post top and testing for smooth functioning complete, all as specified and directed by Engineer-in-Charge.
Repair/servicing of 400/630/800 A 11 KV mechanism/ calibration of HT RMU with highly skilled mechanic specialist in electric HT breakers line,by taking out breaker mechanism, decarborizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/smooth contact, tightening of all connections, checking of alignment for easy moving of breaker, checking of ON/OFF operation with setting of buffer gap adjustment, inspecting the wiring of relays contact travel contact alignments, hard or light setting of breaker greasing of all moving mechanism complete, all as specified and directed by Engineer-in-Charge. Note - Carlibration will be carried out by auth contractor / Tech and test certificate will be kept on record.
S & F in replacement of Gum boot of RMU of various capacity
Repair/servicing of compact Sub station including dry type transformer of various capacity with air blower and necessary insulation and VCB 400 A 11 KV mechanism/ calibration of VCB with highly skilled mechanic specialist in electric HT breakers line,by taking out breaker mechanism, decarborizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/smooth contact, tightening of all connections, checking of alignment for easy moving of breaker, checking of ON/OFF operation with setting of buffer gap adjustment, inspecting the wiring of relays contact travel contact alignments, hard or light setting of breaker greasing of all moving mechanism complete, all as specified and directed by Engineer-in-Charge. Note - Carlibration will be carried out by auth contractor / Tech and test certificate will be kept on record.
S & F in replacement Digital type single pole non directonal relay for one earth fault & two over current, type CDG-31,3D Horz 2 No S/R 3 element O/C & EF comprising over current operator with DC current connecting setting as per ratio including complete wiring complete, all as specified and directed by Engineer-in-Charge.
S & F in replacement Indicator lamp with and including holder & cover to show all the three phase i.e RYB to be mounted on 11 KV HT switch gear, supplying, fixing and connecting complete, all as specified and directed by Engineer-in-Charge.
S & F in replacement Push button for trip and hold of 11 KV 400 A OCB/VCB, S & F complete, all as specified and directed by Engineer-in-Charge.
S & F in replacement Primary copper wound type HT resin cast CTs, air cooled, dual current 3.0 VA, class 1 5P10 of ratio 400/1A, for 3 section protection and suitable burden for metering including making all, connection for relay meter indicator etc. and including connecting testing conforming to IS-2705-1992; complete, all as specified and directed by Engineer-in-Charge.
-Ditto- all as per srl item No 12.00 here-in-before but burden of ratio 2.5 VA, class 1.0 of ratio 300/1A
S & F in replacement Primary copper wound type HT resin cast CTs, air cooled , dual current 15 VA burden of ratio 50/25/5 A, class 5P1O accuracy S T C 18.4 KA for 3 section protection and suitable burden for metering including making all, connection for relay meter indicator etc. and including connecting testing conforming to IS-2705-1992; complete, all as specified and directed by Engineer-in-Charge.
All as per srl item No 14 here-in-before but burden of ratio 100/50/05 A.
All as per srl item No 14 here-in-before but burden of ratio 200/100/5 A.
M&L Maintenance free battery 12 Volt, 40/45 AH complete, all as specified and directed by Engineer-in-Charge.
Excavating in trenches in hard / dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of cable etc not exc 10 Sq mtr on plan and not exc 1.5 mtr in depth and getting out complete, all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete, all as specified and directed by Engineer-in-Charge.
Removing excavated surplus soil to a distance upto 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete, all as specified and directed by Engineer-in-Charge.
Supply and laying un-reinforced precast concrete cable cover class HV type-I flat size 300 mmx180mmx40mm complete, all as specified and directed by Engineer-in-Charge.
Laying only unreinforced precast concrete cable cover class HV type-I flat size 300mm x 180 mm x 40 mm obtained from item Srl No 32.00 complete, all as specified and directed by Engineer-in-Charge.
Material and labour for sand cushioning by using fine sand ( Jamuna dry and clean sand ) in two layers , first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable complete, all as specified and directed by Engineer-in-Charge.
Supply & Laying GI pipe light grade 80mm bore for cable protection with all fittings for passing the under ground HT cable under road crossing along poles walls and floors complete, all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out existing unserviceable defective HT cable any size any type from trenches/duct/ poles including taking out old bricks/PCC cover and keeping serviceable brick/PCC covers in safe custody for reuse complete, all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning for XLPE insulated, screened PVC bedded, galvanized strip, armoured, electric power cable, heavy duty, with aluminium conductor 11 KV (E) grade, cross sectional area 95 Sqmm x 3 core confirming to IS-7098 (Part II) (amended upto date) including supplying, jointing and testing, complete, all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning for XLPE insulated, screened PVC bedded, galvanized strip, armoured, electric power cable, heavy duty, with aluminium conductor 11 KV (E) grade, cross sectional area 120 Sqmm x 3 core confirming to IS-7098 (Part II) (amended upto date) including supplying, jointing and testing, complete, all as specified and directed by Engineer-in-Charge.
Dismantling of old unserviceable cable joints kit of any type and Material and labour for cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete, all as specified and directed by Engineer-in-Charge. Make : RAYCHEM/M-Seal/Birla 3M.
Dismantling of old unserviceable cable joints kit of any type and Material and labour for cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete, all as specified and directed by Engineer-in-Charge. Make : RAYCHEM/M-Seal/Birla 3M
Dismantling of old unserviceable cable joints kit of any type and Material and labour for cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size upto 95 sqmm complete, all as specified and directed by Engineer-in-Charge. Make : RAYCHEM/M-Seal/Birla 3M
Dismantling of old unserviceable cable joints kit of any type and Material and labour for cable jointing kit for 11 KV (E) grade cable for straight through termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete, all as specified and directed by Engineer-in-Charge. Make : RAYCHEM/M-Seal/Birla 3M
Material and labour for cable jointing kit for 11 KV (E) grade cable outdoor for straight through cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete, all as specified and directed by Engineer-in-Charge. Make : RAYCHEM/M-Seal/Birla 3M
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core. The fault located equipment will be brought to site within 02 hours of instruction received from Engineer-in-Charge complete, all as specified and directed by Engineer-in-Charge.
Notes for Srl. Item No.33 : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 24 hours of receipt of intimation from Engineer-in-charge failing which recovery of Rs. 500.00 per hour shall be recovered from the contractors dues w.e.f the time immed -iately after the expiry of 24 hours duration.(ii) For the purpose of payment one unit of “each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch , irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii.) Joints , jointing materials and cable required shall be measured and paid for separately.
Disconnecting the electric supply to the transformer, opening the top cover of 11 KV/0.433KV step down transformer upto 500 KVA capacity by removing the inspection cover/top cover, decanning of the transformer oil upto required level for replacement of LT/HT bush from the shell and replacement for burnt out/ unserviceable LT/HT bush, studs and gasket of buchholes to avoid leakge of oil, refilling of oil into the transformer after required repair works complete, all as specified and directed by Engineer-in-Charge. Note : (a). HT /LT metal studs, HT/LT bushes and gaskets will be measured and paid seperately under respective items here-in after. (b). Replacement of unserviceable bolts, nuts and washers are deemed to be included in the quoted rate.
Disconnecting the electric supply to the transformer,opening the top cover of 11 KV/0.433KV step down transformer of capacity 630 to 1000 KVA by removing the inspection cover/top cover, decanning of the transformer oil upto required level for replacement of LT/HT bush from the shell and replacement for burnt out/ unserviceable LT/HT bush, studs and gasket of buchholes to avoid leakge of oil, refilling of oil into the transformer after required repair works complete, all as specified and directed by Engineer-in-Charge. Note : (a). HT /LT metal studs, HT/LT bushes and gaskets will be measured and paid seperately under respective items here-in after. (b). Replacement of unserviceable bolts, nuts and washers are deemed to be included in the quoted rate.
Supply & fix of HT porcelain bush suitable for any make of transformers upto 500 KVA capacity complete, all as specified and directed by Engineer-in-Charge.
M&L for painting of transformer upto 500 KVA including connected LT bus duct in the transformer room with synthatic enameled grey paint by using spray gun machine after removing all dust and rust. and writing date of paint with black synthetic enamel paint complete, all as specified and directed by Engineer-in-Charge.
Supply and filling of fresh transformer oil in transformers having diaelectric strength 45 KV in 3 mm gap including testing complete, all as specified and directed by Engineer-in-Charge. Make :-M&I MATERIAL (MIDEL) POWER LINK/POWER OIL/SAVITA.
Purification, filtration and Dehydration of transformer oil of transformer installed at various indoor/outdoor sub station by ultra high vaccum filtration machine with stream line filtration plant at a temp 60 to 70 deg. celsius and achieving minimum dieectric withstand strength of 60 KV for 1 minute in 2.5 mm gap setting (for used oil) complete, all as specified and directed by Engineer-in-Charge.
Supply and fix digital type Ammeter of size 96X96 mm on HT panel as that of existing range model to suit to existing CT ratio 100/1A including taking out unserviceable one connectiong testing and commissioning complete, all as specified and directed by Engineer-in-Charge. Make- L&T/SCHNEIDER/LEGRAND.
Supply and fix digital type Ammeter of size 96X96 mm on HT panel as that of existing range model to suit to existing CT ratio 150/1A including taking out unserviceable one connectiong testing and commissioning complete, all as specified and directed by Engineer-in-Charge.
Supply, laying and pasting on floor suitable for HV 11KV synthetic insulating rubber mat of size 2m x1m class A complete with ISI marked.
M&L for disconnecting HT & LT side cables of follwing indoor/outdoor transformer of capacity 63 KVA to 1000 KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure/staging/sub stn and taking down the transformer manually/using mechanical means and lifting loading and transportation to MES store yard/site to civil workshop for repair and opening of covers,draining out existing transformer oil,lifting of core,cleaning of oil tank,using chemicals,cleaning of core after removing HT/LT winding,re-assembling of new HT/LT windings with core varnishing heating and bringing back the same after repairs to the same point complete, all as specified and directed by Engineer-in-Charge. Note-(i) Rewiding of HT/LT coil any type/material, dihydretion of transformer oil reassembling after repair etc.will be measured and paid seperately under relevant item of the schedule. (ii) Spare part shall be measured and paid seperately as supply only and cost of fixing and connection of spare shall be deemend to included in the quoted rate of the above items.
M&L for taking out old unserviceableHT/LT coil removing insulation complete by brushing coil,cleaning the the inner body complete making free from dust and dirt,all impurities, applying paper insulation(IS specified) of transformer complete of capacity 63 to 1000 KVA complete, all as specified and directed by Engineer-in-Charge.
M&L for re-winding of HT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity 63 to 1000 KVA complete, all as specified and directed by Engineer-in-Charge.
M&L for re-winding of LT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity 63 to 400 KVA complete, all as specified and directed by Engineer-in-Charge.
M&L for painting of old painted surfaces with synthetic enemel paint to LT steel tubular/swan neck pole 9 mtr long including clamps,brackets,chanel,cross arms,bracing support,pipe of support for cable and swan neck etc including zebra painting at bottom up to 1.5 mtr above from the PCC couping and writing pole No with white paint complete etc complete, all as specified and directed by Engineer-in-Charge.
Supply and fix in repair hot moulded FRP looping/Junction box size 280 mmx200 mm for street light poles with locking arrangement and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting incl controlled MCB SP-10 Amps -01 Nos enclosed in thermo plastic in closed shock froof safe IP-65, weather,vermin proof,dust and water proof complete with two nos cables entry incl gland of standard size with suitable size mild steel clamps to fixed on pole complete, all as specified and directed by Engineer-in-Charge. Make-Neptune/Hensel/Sintex
Taking out old unserviceable under ground LT cable upto 300 sqmm from trenches/floor/road/pipe/along poles including taking out old bricks complete, all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing in replacement of XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 50 sqmm 3.5 core conforming to IS- 1554 laid in trenches/ducts/along poles/ through pipes complete, all as specified and directed by Engineer-in-Charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Supplying, laying, jointing and testing in replacement of XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 25 sqmm 4 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes complete, all as specified and directed by Engineer-in-Charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Supplying, laying, jointing and testing in replacement of XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 6 sqmm 2 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes complete, all as specified and directed by Engineer-in-Charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Supplying, laying, jointing and testing in replacement of XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 120 sqmm 3.5 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes complete, all as specified and directed by Engineer-in-Charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Supplying, laying, jointing and testing in replacement of XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 240 sqmm 3.5 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes complete, all as specified and directed by Engineer-in-Charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Supplying, laying, jointing and testing in replacement of XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 150 sqmm 3.5 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes complete, all as specified and directed by Engineer-in-Charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable complete, all as specified and directed by Engineer-in-Charge.
S & F In replacement of MCCB 4 pole 415 V, adjustable type 400 amps with breaking capacity of 36 KA complete, all as specified and directed by Engineer-in-Charge.
S & F in replacement of MCCB 4 pole 415 V, adjustable type 250 amps with breaking capacity of 36 KA complete, all as specified and directed by Engineer-in-Charge.
S & F in replacement of MCCB 4 pole 415 V, adjustable type 100 amps with breaking capacity of 36 KA complete, all as specified and directed by Engineer-in-Charge.
Supply and replacement of Silica gel of superior quality for transformers of any capacity and at various sites complete, all as specified and directed by Engineer-in-Charge.
Supply and replacement of breather assembly including Silica gel of superior quality for transformers of any types capacity and at various sites complete, all as specified and directed by Engineer-in-Charge.
M&L for painting of LT panels of various sizes including connected ducting with synthatic enameled grey paint by using spray gun machine after removing all dust and rust complete, all as specified and directed by Engineer-in-Charge.
S&F HT 11 KV cable route indicator made out of cast iron in elliptical shape with embossed HT cable 11 KV on route indicator including standing stamp with fixing arrangement into ground with necessary PCC block of required size complete, all as specified and directed by Engineer-in-Charge.
Ridhi engineers and builders
Commercial Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .