Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAdmitted-Finance 01 BAMLOORA SALOORA GANDERBAL GANDERBAL JAMMU KASHMIR 191131 | GANDERBAL | JAMMU AND KASHMIR | 191131 | L1 | Admitted-Finance | |
| 2 | L2₹9.4 L+₹12,244 (1.32%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹11.3 L+₹2.0 L (22.2%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | GLOBAL AQUATECH L2 | ZAID GULZAR L3 | new lever valley corporation L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing and Commissioning of a Medical Grade Online Reverse Osmosis (RO) Plant of 500 Liters Per Hour Capacity, double Pass along with allied works for the Hemodialysis Unit in Sub District Hospital, Gandoh on Turnkey basis.Complete job as per site condition in all respect as detailed below: complete scope of work had from SBD. | 1 | job | 8,46,744 ₹8,46,744 | 8,50,000 ₹8,50,000 | 50,000 ₹50,000 Lowest |
| 2.00 | Supply, Installation, Testing and Commissioning of Hybrid 5KVA 48V UPS system & Stabilizer for power back up for RO Plant at Dialysis Center in Sub District Hospital, Gandoh for uninterrupted Power Supply with minimum backup of 5-6 hours to the system along with 2-years Warranty as detailed below: 5 KVA UPS design with input voltage range 160-280VAC complete scope of work had from SBD. | 1 | job | 58,000 ₹58,000 Lowest | 1,50,000 ₹1,50,000 | 1,50,000 ₹1,50,000 |
| 3.00 | The work involves installation of inlet and wastewater pipe connections for a 500 LPH RO plant. Existing aluminium partitions are to be modified by covering all transparent glass panels with translucent or patterned film to ensure privacy. Additionally, appropriate soundproofing measures, such as acoustic foam or damping panels, must be installed to reduce operational noise approx. 500 sqft. The materials used should be durable, moisture-resistant, and suitable for healthcare environments. The scope ensures the RO room is functional, private, and compliant with hygiene and acoustic standards necessary for a medical facility. | 1 | job | 27,000 ₹27,000 Lowest | 1,25,000 ₹1,25,000 | 7,00,000 ₹7,00,000 |
| 4.00 | HSD/ POL charges for site inspection during site selection as well as execution of work. | 1 | job | 5,500 ₹5,500 | 5,000 ₹5,000 Lowest | 25,000 ₹25,000 |
Tender Value
₹12.7 L
EMD Value
₹25,400
Closing Date
21 Nov 2025, 12:00 pmClosed
EXECUTIVEV ENGINEER M AND H DIVISION DODA
KHELLANI DODA
Supply Installation Testing and Commissioning of a Medical Grade Online Reverse Osmosis RO Plant of 500 LPH Capacity double Pass along with allied works for the Hemodialysis Unit in CHC Gandoh on Turnkey basis
2025_PWDJK_294614_1
MHDD/TS/2025-26/90
Open Tender
Pumps/Motors
Turn-key
60 days
CHC GANDOH
AS PER SBD
2 documents required · 2 mandatory
₹500
EXECUTIVEV ENGINEER M AND H DIVISION DODA
₹25,400
EXECUTIVE ENGINEER M AND H DIV DODA
6 Dec 2025
8 Nov 2025
21 Nov 2025
8 Nov 2025
21 Nov 2025
8 Nov 2025
17 Nov 2025
Amount
Supply, Installation, Testing and Commissioning of a Medical Grade Online Reverse Osmosis (RO) Plant of 500 Liters Per Hour Capacity, double Pass along with allied works for the Hemodialysis Unit in Sub District Hospital, Gandoh on Turnkey basis.Complete job as per site condition in all respect as detailed below: complete scope of work had from SBD.
Supply, Installation, Testing and Commissioning of Hybrid 5KVA 48V UPS system & Stabilizer for power back up for RO Plant at Dialysis Center in Sub District Hospital, Gandoh for uninterrupted Power Supply with minimum backup of 5-6 hours to the system along with 2-years Warranty as detailed below: 5 KVA UPS design with input voltage range 160-280VAC complete scope of work had from SBD.
The work involves installation of inlet and wastewater pipe connections for a 500 LPH RO plant. Existing aluminium partitions are to be modified by covering all transparent glass panels with translucent or patterned film to ensure privacy. Additionally, appropriate soundproofing measures, such as acoustic foam or damping panels, must be installed to reduce operational noise approx. 500 sqft. The materials used should be durable, moisture-resistant, and suitable for healthcare environments. The scope ensures the RO room is functional, private, and compliant with hygiene and acoustic standards necessary for a medical facility.
GLOBAL AQUATECH (BID ID -2646778)
ZAID GULZAR (BID ID -2647110)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.85 MB
BOQ_953073.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .