Refilling of Fire Extinguishers of Co2 type and ABC dry powder type installed inside the buildings and other common spaces, repairing of firefighting pump set and supply and replacement of defective LED street light fittings at Pocket-7, Sector-A1-A4
2026_DDA_912742_1
22/EE/ELD-4/DDA/2026-27
Open Tender
Electrical Works
60 days
NARELA
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹20,460
16/06/2026 at 12.00 Noon in the chamber of EE/ ELD
12 Jun 2026
12 Jun 2026
20 Jun 2026
12 Jun 2026
20 Jun 2026
17 Jun 2026
16 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Refilling, servicing, testing and refixing of 4.5 Kg CO₂ Type Fire Extinguisher, conforming to relevant BIS specifications and IS 2190, including dismantling, internal and external cleaning, replacement of defective washers, seals, safety pins, discharge horn/hose and other minor components as required, hydraulic pressure testing wherever due, refilling with approved extinguishing media, weighing, leak testing, fixing of service tag/sticker, repainting/touch-up wherever required, refixing the extinguisher at its designated location etc. complete as required. | - | Nos. | 1,904 | - | BI01010001010000000000000515BI0100001113 |
| 2 | Refilling, servicing, testing and refixing of 6 Kg ABC Dry Powder Type Fire Extinguisher, conforming to relevant BIS specifications and IS 2190, including dismantling, internal and external cleaning, replacement of defective washers, seals, safety pins, discharge hose/nozzle and other minor components as required, hydraulic pressure testing wherever due, refilling with fresh ABC dry chemical powder, pressurization, weighing, leak testing, fixing of service tag/sticker, repainting/touch-up wherever required, refixing the extinguisher at its designated location etc. complete as required. | - | Nos. | 1,630 | - | BI01010001010000000000000515BI0100001114 |
| 3 | Dismantling & repairing of 3 phase, 415 V induction motor i/c supply & replacement of suitable ball bearing- 2Nos., connection plate, varnishing, cartage to & fro, painting reinstallation at site, testing etc complete as required.
10 HP (Jockey pump set) | - | Nos. | 12,457 | - | BI01010001010000000000000515BI0100001115 |
| 4 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120<135 lm/Watt)
Supplying, Replacement, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as
per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
120 Watt (Ref. DSR 8.13.16) | - | Nos. | 2,808 | - | BI01010001010000000000000515BI0100001116 |