| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | ₹46.8 L Quoted ₹47.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹48.5 L+₹1.3 L (2.74%)Rejected-AOC | ₹48.5 L+₹1.3 L (2.74%) | L2 | Rejected-AOC L2 |
| 3 | L3₹48.9 L+₹1.6 L (3.45%)Rejected-AOC | ₹48.9 L+₹1.6 L (3.45%) | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
13 Nov 2021, 6:00 pmClosed
GE (AF) Hakimpet
GE (AF) Hakimpet Secunderabad
PROVISION OF CERTAIN E/M WORKS AT AFS BEGUMPET UNDER GE (AF) HAKIMPET
2021_MES_479370_2
8227/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BEGUMPET
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) HAKIMPET
₹84,000
Yes
6 Dec 2021
29 Oct 2021
15 Nov 2021
29 Oct 2021
13 Nov 2021
30 Oct 2021
Amount
Supply, installation, testing & commissioning of Feeder Pillar Box cubical type, factory made, totally enclosed dust and vermin proof, IP 54, free standing, fully compartmentalized in design suitable for 3 phase, 4 wire, 415 volts, 50 Hz system, with 600 Amps capacity, aluminium bus bar, outdoor type, 3mm thick CRCA sheet with inspection doors at front & rear side inclusive of necessary locking arrangement, suitable glands, opening for vent and cable entry, with angle Iron of size 40mm thick including internal wiring with PVC insulated copper cable, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish including taking down old unserviceable panel:- (Location -NTS) (a) MCCB, 4 pole 315A, 25 KA -01 No (Thermal magnetic release, Adjustable type) with rotary switch attachment. (b) MCCB, 3 pole 200A, 25 KA -02 Nos (Thermal magnetic release, Adjustable type). (c) MCCB, 3 pole 160A, 25 KA -01 No (Thermal magnetic release, Adjustable type). (d) MCCB, 3 pole 125A, 25 KA -01 No (Thermal magnetic release, Adjustable type). (e) MCCB, 3 pole 50A, 25 KA -01 No (Thermal magnetic release, Adjustable type). (f) Digital display VAF Panel meter - 01 No. (g)LED Indicator RYB - 01 set of 3
Supply, installation, testing & commissioning of Feeder Pillar Box cubical type, factory made, totally enclosed dust and vermin proof, IP 54, free standing, fully compartmentalized in design suitable for 3 phase, 4 wire, 415 volts, 50 Hz system, with 400 Amps capacity aluminium bus bar, outdoor type, 3mm thick CRCA sheet with inspection doors at front & rear side inclusive of necessary locking arrangement, suitable glands, opening for vent and cable entry, with angle Iron of size 40mm thick including internal wiring with PVC insulated coper cable, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish incluidng takin down old unserviceable panel :- (Location - Wesley S/S) (a) MCCB, 4 pole 160A, 25 KA-01 No (Thermal magnetic release, Adjustable type) with rotary switch attachment. (b) MCCB, 3 pole 125A, 25 KA-02 Nos (Thermal magnetic release, Adjustable type) (c) MCCB, 3 pole 80A, 25 KA-01 No (Thermal magnetic release, Adjustable type) (d) MCCB, 3 pole 50A, 25 KA-01 No (Thermal magnetic release, Adjustable type) (e) MCCB, 3 pole 32A, 25 KA-01 No (Thermal magnetic release, Adjustable type) (f) Digital display VAF Panel emter - 01 No (g) LED Indicator RYB - 01 set of 3
Supply, installation, testing & commissioning of Feeder Pillar Box cubical type, factory made, totally enclosed dust and vermin proof, IP 54, free standing, fully compartmentalized in design suitable for 3 phase, 4 wire, 415 volts, 50 Hz system, with 400 Amps capacity, aluminium bus bar, outdoor type, 3mm thick CRCA sheet with inspection doors at front & rear side inclusive of necessary locking arrangement, suitable glands, opening for vent and cable entry, with angle Iron of size 40mm thick including internal wiring with PVC insulated copper cable, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish including taking down old unserviceable panel:- (Location -CWE S/S) (a) MCCB, 4 pole 160A, 25 KA -01 No (Thermal magnetic release, Adjustable type) with rotary switch attachment. (b) MCCB, 3 pole 160A, 25 KA -01 No (Thermal magnetic release, Adjustable type). (c) MCCB, 3 pole 100A, 25 KA -02 No (Thermal magnetic release, Adjustable type). (d) MCCB, 3 pole 80A, 25 KA- 01 No (Thermal magnetic release, Adjustable type). (e) MCCB, 3 pole 50A, 25 KA- 01 No (Thermal magnetic release, Adjustable type). (f) Digital display VAF Panel meter- 01 No. (g) LED Indicator RYB - 01 Set of 3
Supply, installation, testing & commissioning of Feeder Pillar Box cubical type, factory made, totally enclosed dust and vermin proof, IP 54, free standing, fully compartmentalized in design suitable for 3 phase, 4 wire, 415 volts, 50 Hz system, with 400 Amps capacity, aluminium bus bar, outdoor type, 3mm thick CRCA sheet with inspection doors at front & rear side inclusive of necessary locking arrangement, suitable glands, opening for vent and cable entry, with angle Iron of size 40mm thick including internal wiring with PVC insulated copper cable, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish including taking down old unserviceable panel:- (Location -Gas Agency S/S-R/A side) (a) MCCB, 4 pole 160A, 25 KA -01 No (Thermal magnetic release, Adjustable type) with rotary switch attachment. (b) MCCB, 3 pole 160A, 25 KA -01 No (Thermal magnetic release, Adjustable type). (c) MCCB, 3 pole 80A, 25 KA- 02 No (Thermal magnetic release, Adjustable type). (d) MCCB, 3 pole 50A, 25 KA- 02 Nos (Thermal magnetic release, Adjustable type). (e) Digital display VAF Panel meter- 01 No. (f) LED Indicator RYB - 01 Set of 3
Supply, installation, testing & commissioning of Feeder Pillar Box cubical type, factory made, totally enclosed dust and vermin proof, IP 54, free standing, fully compartmentalized in design suitable for 3 phase, 4 wire, 415 volts, 50 Hz system, with 400 Amps capacity, aluminium bus bar, outdoor type, 3mm thick CRCA sheet with inspection doors at front & rear side inclusive of necessary locking arrangement, suitable glands, opening for vent and cable entry, with angle Iron of size 40mm thick including internal wiring with PVC insulated copper cable, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish including taking down old unserviceable panel:- (Location -DSC S/S) (a) MCCB, 4 pole 160A, 25 KA -01 No (Thermal magnetic release, Adjustable type) with rotary switch attachment. (b) MCCB, 3 pole 100A, 25 KA -02 Nos (Thermal magnetic release, Adjustable type). (c) MCCB, 3 pole 80A, 25 KA -01 No (Thermal magnetic release, Adjustable type). (d) MCCB, 3 pole 50A, 25 KA -02 Nos (Thermal magnetic release, Adjustable type). (e) Digital display VAF Panel meter - 01 No. (f) LED indicator RYB - 01 set of 3
Supply, installation, testing & commissioning of Feeder Pillar Box cubical type, factory made, totally enclosed dust and vermin proof, IP 54, free standing, fully compartmentalized in design suitable for 3 phase, 4 wire, 415 volts, 50 Hz system, with 400 Amps capacity, aluminium bus bar, outdoor type, 3mm thick CRCA sheet with inspection doors at front & rear side inclusive of necessary locking arrangement, suitable glands, opening for vent and cable entry, with angle Iron of size 40mm thick including internal wiring with PVC insulated copper cable, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish including taking down old unserviceable panel:- (Location -Tern Block) (a) MCCB, 4 pole 200A, 25 KA -01 No (Thermal magnetic release, Adjustable type) with rotary switch attachment. (b) Change over switch ON-LOAD type 4 pole 200 Amps - 01 No. (c) MCCB, 3 pole 160A, 25 KA -01 No (Thermal magnetic release, Adjustable type). (d) MCCB, 3 pole 100A, 25 KA -01 No (Thermal magnetic release, Adjustable type). (e) MCCB, 3 pole 63A, 25 KA -03 Nos (Thermal magnetic release, Adjustable type). (f) Digital display VAF Panel meter - 01 No. (g) LED indicator RYB - 01 set of 3
M&L earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, Earth plate shall be connected to & including the galvanized iron strip 32x6 mm upto test point and connected with bolts, nuts, check nuts & washers including suitable size light grade GI pipe for protection of galvanized iron strip up to plinth, and further connecting with GI wire for Distribution boards, including excavation, earth work, Charcoal & Salt all as specified, PCC chamber, RCC cover slab, watering pipe 20 mm dia bore med. grade, wire net, funnel etc. & testing on completion all as specified in plate No.3 of SSR Pt I, including taking down exisiting earthing. Note: Protection pipe for earthing lead beyond 7.5m shall be measured and paid seperetly under relevant items.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 MPa working pressure, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core includnig taking down old unserviceable cable, complete all as specified and directed.
All as per item No.9.00 above but of size 3.5 core 70 sqmm
All as per item No.9.00 above but of size 3.5 core 95 sqmm
S&F in repair 4 pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 25 KA housed inside outdoor type enclosure made of 3mm thick CRCA sheet and fitted over existing wall, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m in wide and not exceeding 1.5m in depth for laying of cables / pipes and getting out in soft/loose soil, complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering, well ramming in layers not exceeding 25 cm thick in any type of soil, complete all as specified and directed.
Removing, surplus excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and spreading clean, fine, dry river sand in trenches for cushioning of under ground cable / inside transformer yard complete all as specified and directed by Engineer-in-Charge. Note:Only punned thickness shall be measured for payment purpose.
Supply and laying un-reinfored pre-ast concrete cable coveres, class LV, Type I, flat, size 250mm x 150mm x 40mm for LT cable protection, complete all as specified and directed.
S&F in repair Galvanised iron earth strip 32x6mm earth continuity conductor as main earthing lead fixed to equipment etc as required, complete all as sepciied and directed.
S&Lay in repair Galvanised iron pipe fixed in ceilings or lain in floors / trenches / road crossings for the protecteion of cables for the following sizes, complete all as sepciied and directed:-
50mm bore
80mm bore
Supply, install and commissioning hi wall 1.5 ton split units indoor / outdoor complete with cordless remote control unit, copper tubing and thermal insulation between IDU & ODU, anti dust filter, HD filter, star rating - Inverter 5 Star, Refrigeranc type-R 32, condenser-copper, Compressor - Twin Rotary, LED Display, Self Diagnosis. Anti fungal feature, Auto Restart, Timer etc all as specified and as directed, Note : (i) Quoted rate deemed to be included cost of making necessary hole into stone / brick wall for copper tube & power cord and making good to damage all as existing. (ii) Outdoor unit shall be mounted on MS bracket and quoted rate is inclusive. (iii) Copper tube suction & discharge with thermal insulation puff beyond length as provided by OEM with AC unit will be measured and paid separately. Make : VOLTAS / HITACHI / CARRIER / DAIKIN
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with built-in-thermal overload protection, initial time delay system, Low and High voltage cut-off protection and of capacity 4 KVA.
S & F Sub main wiring with Two runs of single core wires of 6.0 Sqmm PVC insulated and unsheathed stranded copper conductor cable FRLS drawn through and including non metallic rigid PVC conduit (surface), ISI marked, medium grade of suitable size complete with all accessories/ fittings including earth continuity wire withone run of 6.0 Sqmm PVC insulated, unsheathed copper cable, single core and connecting to earth dolly with all fixing material complete all as specified and directed. Note: Two runs of 6 Sq mm + one runs of 6 Sq mm for earth continuity conductor and One run of suitable size PVC conduits measured as one unit length. Make: For Copper wire 1100V: Finolex, Havells, HPLand For PVC Conduit: Sudhakar, Tirupati, Atul
Supply and fix 20 Amps SP MCB C Curve 10 KA breaking capacity alongwith metal clad Plug and socket with enclosure suitable for Air Conditioner.
Supply and fix new copper tubes of suitable size for suction and discharge lines for split type air conditioners including necessary brazing, thermal insulation puff etc allas directed by the Engineer-in-Charge. Note:- One run of suction, one run of discharge pipe and one run of thermal insulation puff shall be measured as one unit length.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron or steel earth lead strip 32x6 mm size by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 40mm dia light grade pipe for protection of GI earth strip etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to LT panel board as indicated including testing complete all as specified and directed. Note: Rate qouted is deemed to include cost of earth strip and protection pipe upto 7.50 m.
Taking down the damaged / punctured cable from the excavated trench for cutting and removing the damaged portion of the cable, jointing the serviceable part of the cable of cross-sectional area 70 Sqmm, 3.5 Core, complete all as specified and directed. Note: Excavation and relaying shall be measured separately under relevant items.
Relaying the repaired and serviceable part of the cable in the same trench or new trench as per site conditions, of cross-sectional area 70 Sqmm, 3.5 Core, complete all as specified and directed. Note: Excavation and jointing shall be measured separately under relevant items.
Supply and laying of XLPE insulated, armoured, heavy duty electric cables with aluminium conductor, 1100 volts grade, of following cross-sectional area 70 sqmm, 3.5 core, complete all as specified and as directed. Make: Nicco / Gloster / Havells / CCI.
Supply, install, testing and commissioning of single phase Isolation transformer, indoor type, air cooled, input range 230 volt and output range 230 volt +/- 1% of capacity 1 KVA all as specified and directed. Note : Quoted rate shall deemed to be included cost of connecting incoming/outgoing three core copper wire of suitable size upto length of 2 RM x 2 sides of transformer=2 RM. Make: Volina, Bajaj, V-Guard, Power one, Power one micro system.
All as per item No.30.00 above but of capacity 2 KVA single phase
All as per item No.30.00 above but of capacity 10 KVA single phase
M&L for earth continuity GI conductor strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to wall or any other indicated situation for loop earthing etc. of size 25x4mm, complete all as specified and directed.
S&F Single core copper flexible wire of 50 Sqmm size
S&F Porcelian insulators for fixing earthing strip all as specified and directed
M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge, including taking down.
Cutting and removing the damaged portion of the LT cable, supply, prepare and connect cable jointing kit for 1.1KV grade cable for cold shrink typeTermination end joint complete with jointing material and accessories suitable for XLPE, armoured aluminium conductor cable of size 3.5 x70 Sqmm complete all as specified and as directed. Make:3M/Reychem/Dension. Note: Earth work will measured and paid seperately under relevant items.
Taking down carefully existing 20/36 watt FTL fitting and handing over to AGE E/M store yard for taking into charge/ considering under schedule of credit.
S&F 10W LED light fitting 2" wall mounted decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack including suitable copper cable all as specified and directed by Engineer - in - Charge. Make : Havells / Phillips / CG.
S&F 20W LED light fitting 4" wall mounted decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack including suitable copper cable all as specified and directed by Engineer - in - Charge. Make : Havells / Phillips / CG.
Supply and fixing of 7/9 W LED, bulb all as directed by Engineer-in-charge including taking down existing CFL bulbs.
Supply and Install wind operated Turbo Air Ventilator 600mm sweep over roof sheets complete with all fixing accessories :- Note : (a)Wind operated Turbo Ventilator shall be of size 600mm sweep and material of construction for ventilator shall be of high grade industrial aluminium of thickness not less than 0.5mm and material of construction for hardware as stain less steel 304. The bearings shall be steel in completely enclosed and dust proof integrated housing and aligned each other. (b) Fixing arrangement shall have high quality material all as recommended by OEM to prevent rain ingress and all Turbo ventilators to be installed by manufacturers authorised person only. (c ) Contractor shall give NO rain water leakage guarranty for minimum three years from date of installation of Turbo ventilator. (d) Cost of cutting of existing roof sheet of hanger all as per manufacturer recommendation and making good is deemed to be included in quoted rate Make:Sudha Ventilator System, RK Aircon, Airwell System.
Supply and lay cable XPLE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:-
35 sqmm , 3.5 core
25 sqmm, 4 core
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed by Engineer-in-Charge.
Material and labour for GI tubing light grade 40mm bore with fittings in replacement laid for protection of cable under road crossing fixed to walls or pole complete all as specified and directed.
Feeder Pillar Box cubical type, factory made, suitable for 3 phase, 415 volts, 50 Hz system, with 200 Amps capacity aluminium bus bar, Outdoor type, factory fabricated with 3 mm thick CRCA sheet with inspection doors at front & rear side inclusive of necessary locking arrangement, suitable opening for vent and cable entry, Spare terminal for MCCB- 01 Nos, change over switch and VDB-01 Nos with angle Iron of size 50x50x5 mm thick, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish complete with the following items. (i) MCCB TPN 100A, 415V, 25KA - 01 (ii) VDB TPN 4 way - 01 (iii) MCCB TP 63 Amps , 25KA, Suitable for fixing in MCB DB 'C' series (iv) MCB SPN 40A, 230V (v) MCB TP 40A, 230V (vi) Power & Control wiring (vii) Change over switch 100 Amps
M & L earth continuity conductor or main earthing lead fixed to wall on batten or chases or buried in ground or drawn in conduit / pipe or fixed to wall or any other indicated situation for loop earthing etc. as required 4.0 mm galvanised iron wire.
S&F MCB distribution board double door, verticle type, TPN 4way , sheet steel powder painted with bus bar neutral link earth bar etcNote :- MCCB and MCB will be measured and paid separately under relevant items..
Supply & fix MCCB TP 63 Amps , 10KA , suitable for fixing in MCB DB 'D' series complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixed MCB SP 5 to 32 Amps, 240 volts, suitable for fixing in MCB DB 'C' series complete all as specified and as directed by the Engineer-in-charge.
M&L for High galvanized mast light suitable for 6 to 9 lantern symmetrically fitted alongwith their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 7/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation for 16 m height all as directed by the Engineer-in-Charge. Make:- Crompton Greaves Ltd or equivalent make of Philips / Bajaj.
Specifications: High mast structure (a)Bottom Dia:360 mm (b)Top Dia: 150 mm (c)Material of construction: BSEN 10025/IS 2062 (d)Material Thickness: 3 mm (e)Type of Joint: Stress slip fit joint (f)Length of overlap: 1.5 times Dia of insertion (g)Metal protection Treatment: Hot dip galvanised as per IS 4759/IS 2629 (h)Thickness of Galvanisation: 70 Micron (i)Size of Door opening at base of Mast:Not less than 900 mm x 250 mm (j)Type of locking: Close fitting door with alllen key,locking with suitable reinforcement to avoid buckling at base of mast (k)Lightning protection: GI single spike of length 1600 mm (l)Size of base plate: 520 mm dia 25 mm thickness
Dynamic Loading on site (a)Max wind speed: 180km/hr (IS 875-1987) (b)Number of Foundation bolts: 06 No (c)PCD of foundation Bolts: 445 mm (d)Dia of foundation bolts: M24 (e)Length of foundation bolts: 750 mm Lantern Carriage (a) Material of construction of lentern carriage : 40 NB ERW Class B-MS Pipe (b) Diameter of Lantern carriage ring : 600mm (ID) (c) Contruction of Lantern Carriage : 4 Arm Welded (d) Number of Joints of Lantern carriage : 2 Segments (e) Load carrying capacity of lantern carriage : 6 Luminaire, Symmetrical
Winch (a) Number of Drums per Winch : Double Drum (b) Gear Ratio : 50 : 1 (c) Capacity : SWL 500 Kgs (d) Method of operation : Motor OR Manual (e) Lubrication Arrangement : Self lubricating in permanent oil bath (f) Type of Lubricant : SAE - 90 / 140 Stainless Steel Wire Rope (a) Grade : AISI 316 (b) Diameter of SS Rope : 6mm (c) Construction of SS Rope : 7/19 (d) Number of SS Ropes : Two Wire Rope System (e) Thimbles & Terminals : Provided (f) Breaking load Capacity : 2350 Kgs per SS Wire Rope
Trailing Cable (a) Type : Flexiable copper 5 core 2.5 Sq mm (b) Materials : EPR insualted PCP sheathed / PVC (c) Make : I S Approved Brand (d) No of circuits per mast : One Power Tool (a) Model : Integral (b) Capacity (HP) : 1 HP (c) Number of Speeds : Single Speed (d) Reversible / Non-Reversible : Reversible (e) Input Supply : 415 Volts / 240 Volts
Feeder pillar box: (a)MCB 4 pole 20 A,10 KA - 01 No (b)LED indicator RYB - 01 set (c)Digital display VAF panel meter - 01 No (d)3 Phase power contactor - 01 No (e)Digital Timer - 01 No Note: Contractor must produce the Foundation drawing duly approved by the OEM for installing the Highmast.
Supply & fix LED Flood light luminaire,120 watt with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 protection Make: C&S Orion-3.0,120 watt, ordering code LTEF120WHPLED Bajaj Product code 169641, Luminaire type BARFEG 120W LED
M&L for cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core, 16 Sqmm.
Road cutting/hard standing upto a depth of 15 cm after taking up cable,well ramming the excavated soil and repair the excavated portion of road/hard standing by providing suitable PCC 1:2:4, 75mm thick over hard core 75mm thick all as specified and directed
M&L for sub-main wiring alongwith earth wire, with 4 runs of 6.0 Sqmm (3Ph+1N) +2x4.0 Sqmm (earth) FRLS PVC insulated, unsheathed, 1100 volts grade, multi-stranded, copper cable single core, drawn through and including double locking type PVC casing and caping and its all accessories of suitable size on wall/roof surfaces including taking down unserviceable submain wiring of any description complete all as specified and directed by Engineer-in-charge. Note-Four runs of 6.0 Sqmm and two runs of 4.0 Sqmm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.
Chandana Enterprises
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .