Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹38.3 LAccepted-AOC C 2 MADEL INDUSTRIAL ESTATE NEAR VIRWANI INDUSTRIAL ESTATE ROAD NO 2 GOREGAON E MUMBAI 400063 | MUMBAI | MUMBAI | MAHARASHTRA | 400063 | L-1 | Accepted-AOC Successful Lowest L-1 Bidder |
Tender Value
₹38.3 L
EMD Value
₹76,655
Closing Date
27 Aug 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sr.Manager (Engg.-Elect.)
Airports Authority of India, Room No.002, Ground Floor, ATS Complex, Sutar Pakhadi Road, Andheri (East), Mumbai - 400 099.
Replacement of Electro Hydraulic Bollards at ATC Sky Tower, C.S.M.I.Airport, Mumbai
2024_AAI_202640_1
MUM/ATS/ENGG-E/eNIT-02/2024-25
Open Tender
Electrical Works
Works
120 days
ATC Sky Tower, C.S.M.I.Airport, Mumbai
As per PQ Performa
5 documents required · 5 mandatory
₹1,180
₹76,655
24 Oct 2024
26 Jul 2024
28 Aug 2024
26 Jul 2024
27 Aug 2024
26 Jul 2024
26 Jul 2024 - 16 Aug 2024
Amount
SH-I : Supply, Installation, Testing and Commissioning of Electro Hydraulic Bollard system
Supply, Installation, Testing and Commissioning of K8 Crash Rated Electro Hydraulic Bollard system comprising of 4 number of Bollards, suitable for operations in temperature range from 0 degree to +60 degree Celsius and also capable of working in the heavy rainfall of Mumbai, to work on 230V (1-Phase) / 415V (3-Phase) 50Hz AC supply consisting of controllers, control panel and logic circuits with all other associated accessories like provision of manual operation during power shut down, Hydraulic Power Pack/Unit with accumulator/ battery back up, safety interlock detector, self priming sump pump for draining water, control and logic circuit in a weather proof enclosure compliant to IP67 standards with provision for integrating with external access control system like loop detectors, crash pads etc. if any, operational alerts /system alerts with blinking LED, audio signal during operation, capable to perform switching operation in local & remote location. Each Bollard shall be of SS-316 with thickness not less than 16mm and having a diameter not less than 273 mm(OD), mounted at a height not less than 800 mm (height ), the Bollards shall be grouped in set of 4 and the distance between each bollards shall be less than or equal to 1250 mm and the Bollards shall be duly tested as per NABL/ASTM/DOS/PAS/IWA 14:2013, including provision of cables with all accessories, laying of cables in suitable HDPE/DWC/GI pipes, connections, interconnections, earthing, civil foundation work, cutting & repairing the roads, fixing the bollard, concrete work etc. complete as per site requirement. (4 Hydraulic Bollards of K8 Rating and associated system= 1 SET) i. Height- minimum 800 mm(measured from the top of the bollard to the top of foundation frame) ii. Bollard Dia.- minimum 273 mm (OD) iii. Thickness - 16 mm (min) iv. Rising/Descent Time - 3 to 6 sec v. Frequency of Operation - minimum 100 cycles/hr vi. Power Fail Operation - minimum 03 (three) full cycle operation. vii.Control Panel - UP/Down/Stop, middle stop operation and maintenance switch
Dismantling of existing Hydraulic Bollards System alongwith Control Panel, Cables etc including stacking of serviceable material and disposal of unserviceable civil material/debris, finishing the damaged pavement with cement concrete etc. as per direction of Engineer-in-charge complete as required. (4 Bollards and associated system=1 SET)
Excavation and refilling in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) as and where required alongwith amking good of the surface.
SH-II: All inclusive Comprehensive Maintenance after DLP
All inclusive Comprehensive Maintenance Contract (AICMC) of 1 complete system of Bollard as mentioned in BOQ Item No. 1 after completion of Defects Liability Period (DLP) during the following years, including all components, spares, consumables and carrying out monthly preventive maintenance as per standard practice/ OEM recommendations, unlimited breakdown maintenance and submission of service reports of all activities. (DLP will be 01(one) year from the certified date of completion of S.I.T.C work)
For the First Year after DLP (% of BOQ Item.1)
For the Second Year after DLP (% of BOQ Item.1)
For the Third Year after DLP (% of BOQ Item.1)
For the Fourth Year after DLP (% of BOQ Item.1)
For the Fifth Year after DLP (% of BOQ Item.1)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .