Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | ₹38.6 L Quoted ₹40.4 L | L1 | Accepted-AOC AOC |
| 2 | L2₹44.7 L+₹4.3 L (10.7%)Rejected-Finance | ₹44.7 L+₹4.3 L (10.7%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹45.1 L+₹4.7 L (11.6%)Rejected-Finance CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | ₹45.1 L+₹4.7 L (11.6%) | L3 | Rejected-Finance Other than lowest |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
20 Feb 2023, 6:00 pmClosed
GE (AF) Utarlai
GE (AF) Utarlai PB No. 11 Barmer (Raj) 344001
SPECIAL REPAIR TO SWITCH ROOM AT OPS COMPLEX, LIGHTNING, CONDUCTOR, EARTHING AND ALLIED WORKS OF CERTAIN BLAST PENS AT AF STN UTARLAI
2023_MES_576768_1
8360/E8
Open Tender
Civil Works
Item Rate
180 days
Utarlai
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹81,000
Yes
12 May 2023
23 Jan 2023
27 Feb 2023
24 Jan 2023
20 Feb 2023
6 Feb 2023
Amount
Taking down old unsv sub main wiring including connected items complete all as specified and directed.
Supply and fixing of wiring for circuit/submain wiring alongwith earth wire with the FRLS PVC insulated copper conductor single core cable of size 2x1.5 sqmm+1x1.0sqmm earth wire in suitable size of steel conduit complete all as specified and directed. Note :- (i) Rates are deemed to be included chases of conduit and making holes in wall/floor for passing in or through conduit (ii) Two runs of 1.5 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 1.00 sqmm copper conductor cable (FRLS) as a earth leadand one run of steel conduit will be measured as a one unit.
Supply and fixing in repair LED street light fitting 70 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make:- (i) Crompton Cat part-TRP-409-70-57-SL-GI-NSG (ii) Havells Cat Part-ENDURAOMNIPLUSSL 70 WLED 57SASYTOPC (iii)Orient Cat Part- LSFS-070-C or Equivalent in Philips/ Wipro/ Syska/ Polycab
Supply and fixing in repairs GI pipe bracket 'light grade' of 50mm dia bore ISI marked duly bent to shape with an angle including clamps, nuts, bolts, washers etc along with two coats of synthetic enamel paint over a coat of red oxide primer with preparation of new steel surface complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 mtr depth for laying of cable and getting out in soft/loose type of soil and n.exc 10sqm on plan complete all as specified and directed.
Removing of excavated surplus soil not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specifed and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exc 25 cm thick in soft/loose soil complete all as specified and directed.
M & L for sand cushioning to all around the cable protection of natural Tibba sand all as directed. (Note : Punning thickness will be measured and paid for payment purpose.)
S & L stone patti quarry faced Jodhpur type 4 to 5 cm thick and 25 to 30 cm wide putting on cable abutting to each other for cable protection all as directed.
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 32mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete all as specified and directed.
Disconnecting and taking down old U/S changeover switch of any type/rating/make incl supply and installation On load changeover switch 4 pole 63 Amp in sheet steel enclosure complete with required electric accessories and mounting arrangement complete all as specified and directed.
S & F in repair TPN distribution board 8 way I/C-8 , O/G-24 including incoming MCB 63 A C curve FP-01 No.,RCBO 63 A sensitivity 300mA -01 No., MCB 6 A C curve DP -03 Nos MCB 32 A C curve DP -07 Nos fixing on pole/wall with MS Clamps/nuts/bolts and connecting with incoming and outgoing cable complete all as directed .
Supply & install testing and commmissioning outdoor LT electric panel ( KIOSK) consisting of double door, weather proof,separate compartment with locking arrangement, cubical panel floor mounting fabricated out of 3.15 mm thick MS sheet on angle iron frameof 25x25x5mm and legs made of angle iron 40x40x6mm, painted with powder coated and pre coated primer including necessory PCC 1:3:6 using 40mm graded stone aggregate type C2 foundation and earth work and comprising the following :- (a) Bus bar of 3 phase 4 strip 415 volts with 400 Amps copper strip 1 set Incomer- (b) MCCB 250 Amp 35 KA adjustable TM range 4 pole -01 Nos Outgoing- (c) MCCB 100 Amp 25 KA adjustable TM range 4 pole -08 Nos (d) MCCB 63 Amp 25 KA adjustable TM range 3 pole -03 Nos (e) Voltmeter digital 0-500 volt = 01 (f) Amp meter digital 0 -200 Amp = 01 (g) Indicator lamp yellow , Red , blue - 01 Set (h) Complete Int wiring with copper condutor - 1 Lot (j) Extra space for two feeders Note :(I) All termination of cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth lead wire 4.0mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing wire shall be protected by galvanised iron or steel pipe 20 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete all as specified and directed.
M &L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required to, 25x3 mm galvanised iron strip galvanised iron or steel wire complete all as specified and directed.
M &L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required to, 4 mm galvanised iron or steel wire complete all as specified and directed.
Supply & Laying, Jointing and testing in replacement underground armoured cable LT XLPE insulated cable 1100 Volts PVC bedded galvanised steel strip or wire armoured electric LT UG cable heavy duty with multi stranded aluminium conductor laid in trenches / walls/ ducts passing through pipe cable of following size complete all as specified:-
95 Sqmm 3.5 core
50 Sqmm 3.5 core
25 Sqmm 4 core
10 Sqmm 4 core
Supply and fixing automatoc power factor correction APFC panel for 3 phase 415 V 50 Hz system of capacity 100 KVAR (Combination of Steps from 1 KVAR to 20 KVAR as per site requirement) with incoming MCCB of rating 160 Amps adjustable TM range complete all as specified and directed by Engr-in-charge
Supply and fixing in repair GI pipe medium grade of 50mm dia of bore ISI marked including clamps, nuts, bolts, washers etc compltete all as specified and directed by Engineer-in-Charge.
S & F end termination cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing of following sizes:-
25 to 50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
S & F Straight through cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing of following sizes:-
25 to 50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
Labour for drilling hole under road for laying of U/G cable through pipe of suitable size complete all as specified and directed at site.
Supply install and testing out door wheather proof bus bar chamber of size 120 cm x 40 cm x 40 cm made out of 18 SWG MS sheet having one side openable hinged door shuter with looking arangement mounted on 40x40x6mm anlge iron frame with legs welded and 04 nos copper bus bar of 300 Amp rating provn of one MCCB TPN 200 Amp 16 KA for controlling Electric supply complete erracted on ground with necessary PCC 1:3:6 type C2 using 40mm graded stone aggregate foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbles complete all as specified. NOTE: Cost of dismantling/ taking down old unserviceable bus bar chamber shall be included in the quoted rate of this item.
Supply install and testing of out door wheather proof bus bar chamber of size 80 cm x 30 cm x 25 cm made out of 18 SWG MS sheet having one side openable hinged door shuter with looking arangement mounted on 40x40x6mm anlge iron frame with legs welded and 04 nos copper bus bar of 200 Amp rating provn of one MCCB TPN 100 Amp 16 KA for controlling Electric supply complete erracted on ground with necessary PCC 1:3:6 type C2 using 40mm graded stone aggregatefoundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland , lugs/thimbles complete all as specified. NOTE: Cost of dismantling/ taking down old unserviceable bus bar chamber shall be included in the quoted rate of this item.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75mmx75mmx25 mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw all as specified & directed.
Material and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as directed by Engr-in-Charge
Material and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25X20cm size complete all as directed by Engr-in-Charge
Supply and fixing LT cable route indicator cast iron of suitable size mounted on 40 x 40 x 3 mm angle iron with height of 1.5 metre along with LT cable trench including planting in ground with PCC complete all as specified and directed.by Engr-in-Charge.
Supply and fixing in repair LED street light fitting 35 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make:- (i) Crompton Cat part-LSTS-36-CDL-M (ii) Havells Cat Part-ENDCITYPLAT+SL35WLED757SASYBOPCWOSPD (iii)Orient Cat Part- LSFS-070-CF or Equivalent in Philips/ Wipro/ Syska/ Polycab
Supply and fixing of wiring for circuit/submain wiring alongwith earth wire with the FRLS PVC insulated copper conductor single core cable of size 4x16 sqmm+2x10.00sqmm earth wire in suitable size of steel conduit complete all as specified and directed. Note :- (i) Rates are deemed to be included chases of conduit and making holes in wall/floor for passing in or through conduit (ii) Four runs of 16 sqmm single core (FRLS) PVC insulated copper conductor cable two runs of 10.00 sqmm copper conductor cable (FRLS) as a earth leadand one run of steel conduit will be measured as a one unit.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galavanised steel wire or tape and overall PVC sheathed 4 Sqmm 4 core nominal cross section multi stranded conductor all as specified and directed.
S & F in replacement of HDPE junction box of size 32 cm x 23 cm with cable glands, connector 3 P+1 N on insulators and necessary mounting arrangement ,MCB SP upto cap of 2 Amp and fixing on poles with MS Clamps and connecting with existing cable complete all as directed.
S&F repairs Aluminium Strip 25 x3 mm with Saddles (with CC not more than 50cm) and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground and all Joints should be connected complete all as specified and as directed. NOTE: All Joints should be joined by Brazing
S&F in repair Air Termination Single Pointed Aluminium Rod 12 mm dia and 300mm long with Galvanised Steel Tubing 40mm bore (dia), 1.20 Metre long, light grade fixed on cement concrete block of size 300x300x300mm made on Cement Concrete 1:2:4 (20mm graded stone aggregate) and necessary Fixing Arrangement at Roof, complete all as specified and as directed. NOTE PCC will be measured and paid saperately under relevant item of Sch. If threaded of the GI Tubing is damaged then Contractor will be responsible for cutting of thread for fixing the GI Tubing
M&L for Cement Concrete block of size 300x300x300 mm made with cement concrete 1:2:4 (20mm graded stone aggregate) necessary Fixing Arrangement at Roof for fixing of GI pipe of air termination rod and Block of size 150x150x150 for fixing of Aluminium strip on roof, complete all as specified and as directed.
Material & labour in replacement for Electrical Earthing with GI plate electrod of size 60 cm x 60 cm x 6mm thick burried directly in ground vertically earth pit not less than 2.5 mtr deep below normal ground level with the top edge of the earth plate at a depth not less 1.5 mtr below normal ground level connected to Gl strip earth lead of size 32 x 6 mm by means of bolts, nuts, washers made of galvanised iron and connected main control board/switch gear/pannel boards all as specified and shown in Electrical plate No 3 of MES shcedule (SSR) Part-1, 2009 including necessary excavation and earth work in any type of soil, charcoal dust, salt and PCC 1:2:4 type B1 in chamber RCC 1:2:4 type B1 in cover slab with 6 mm dia mild steel bars at 100 mm center to center both ways and with 6 mm dia MS hook complete and testing resistence all as specified and directed. Note:- (1) GI strip 32 x 6 mm upto 7.5 mtr length shall be deemed to include in this items rate. (ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contractor.
S&F test point terminal block made of gunmetal or prosperous bronze size 75x75x25 mm drilled and screwed including 3 nos 8 mm dia 25 mm long hexagonal screw complete all as specified and directed.
Supply and lay Low density poly ethylene pipes (LDPE) of pressure rating 6 kg/cm2 40 mm dia laid in trenches complete all as specified and directed.
Supply and fix in replacement GI strip 32x6mm for loop earthing laid in ground. Note:- Earth work will measured and paid saperately.
S&F earthing pit identifier / marker for lightening arrester made of MS plate 3 mm thick oval size having major axis 30 cm & minor axis 20 cm mounted on 25 mm dia GI pipe medium grade project 60 cm above the ground and embeded suitably in concrete PCC 1:2:4 type B2 of size 20 cm x 20 cm x30 cm. The oval shape identifier & earthing pit cover shall be painted with two coat of synthetic enamel paint over a coat of primer and writing letter e.g. LA 1/10 on the plate and earth pit cover complete all as specified and directed.
S&F Aluminium gutka 40mm dia and 40mm long externally threaded as per the GI socket of 40mm and internally threaded suitable for fixing 12mm dia aluminium air terminal rod all as specified and directed.
Dismantling of Air termination rods
M/s Pankaj Enterprises
M/S PRASHANT BENIWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .