Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹1.3 Cr+₹4.4 L (3.45%)Rejected-Finance | ₹1.3 Cr+₹4.4 L (3.45%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹1.4 Cr+₹8.2 L (6.41%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | ₹1.4 Cr+₹8.2 L (6.41%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹1.4 Cr+₹8.9 L (6.91%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹1.4 Cr+₹8.9 L (6.91%) | L4 | Rejected-Finance Other than lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
17 Oct 2023, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura
As per tender documetns
2023_MES_618599_1
CWE/MTR/BPR of 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
As per NIT
7 documents required · 7 mandatory
₹1,000
GE BHARATPUR
₹2.1 L
Yes
8 Dec 2023
13 Sept 2023
19 Oct 2023
13 Sept 2023
17 Oct 2023
4 Oct 2023
Amount
S&F lnsulated PVC Wall Lining consisting of PVC Insulated Panels having expanded polystyrene (EPS) stuck to 2mm thick wood grain printed PVC sheet duly fitted into the wall as per specifications and drawing complete all as specified and as directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawining complete all as specified and as directed.
Taking down of frame with shutter exc. 1.5sqm but nexc. 4.00sqm complete all as specified and as directed.
Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 42x50 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per direction.
M&L for Toughened glass of 12mm as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and as directed.
M&L for Mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, Mithrivedted, bolted or welded attachment, confirming to Fe-410-W Gde E-250 quality-A complete all as specified and as directed.
M&L for Mild steel framed work as in doors or gates of angle or other section guesset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc.to prepared for sliding with (execlusive of steel plate) also fastening and fixing complete all as specified and as directed.
M&L for two coat fire resisting paint over primed Surfaces of any description wood, steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth complete all as specified and as directed.
Demolition Cement concrete (reinforced) concrete of any description and in any position not otherwise specifically provided etc complete all as specified and directed.
M&L for Cement concrete type D-2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete including earthwork if required complete all as specified and as directed.
M&L for Cement concrete 1:2:4 type B1 using 20mm aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts complete all as specified and as directed.
M&L for preperation of old Brick/concrete /plastered / stone /Asbestos surface of any description and applaying one coat of Camouflage pattern exterior emulsion paint complete all as specified and as directed complete all as specified and as directed.
M & L Preparation of old decorated plastered or un decorated plastered surface of wall including cornices, pilasters etc by brooming down, steel wire brushing ,scraping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coat of distemper oil emulsion on wall complete all as specified and as directed.
All as per Srl item No 14 here in above but applying two coat of Distemper oil emulsion on ceiling complete all as specified and as directed.
Taking down of old unserviceable copper / aluminium point wiring (light) with conduit complete including fitting & fixture such as switches, ceiling roses, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
Taking down old unserviceable sub main wiring of any size complete all as specified and as directed.
Taking down old unserviceable distribution boards of any size complete all as specified and as directed.
M&L existing conduit point wiring complete with two runs of 2.5 sqmm, single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable, 1100volts grade IS-694 marked drawn through with teflon tape sealed in all threaded joints in conduit and fittings for light points and including 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade earth continuity wire (connecting to earth dolly) & wiring shall be done as per STEC-7 for Two light points controlled by one switch/MCB complete all as specified and as directed.
Point wiring complete with 2.5sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable 1100 volts grade drawn through and including rigid steel ERW conduit (stove enamled) heavy duty as per IS 9537 Part I and all necessary flame proof, weather proof conduit accessories and fitting fixed to the surface of wall/ceiling with teflon tape sealed in all threaded joints in conduit and fittings for light points and including 2.5 sqmm (or nearest equivalent metric size) single core multi stranded copper conductor PVC insulated and unsheathed cable 1100 volts grade continuity wire (connecting to earth dolly) & wiring shall be suitable for frame proof area as per STEC-7 for Two light points controlled by one switch/MCB complete all as specified and as directed.
Supply and fixing in replacement of factory made mild steel flame froof distribution boards, class LM-6 , protection class (IP-55) CMRI certified suitable for gas group IIA & IIB suitable for mounting MCB/RCCBs, DBs TP&N 4 way, 415 volts conforming to IS-2143 with minimum 200A rating copper bus bar Comprising complete all as specified and directed of following :- (i) Lighting distribution panel (ii) Incoming: - MCB , 4P 63AMP - 01 Nos (iii) Outgoing :- MCB, 1P, 6AMP -12Nos (MCB - L&T/Schneider or equivalent make) with complete internal Bus bar & wiring up to terminals.
Supply and fixing in replacement of factory made mild steel flame froof distribution boards, class LM-6 , protection class (IP-55) CMRI certified suitable for gas group IIA & IIB suitable for mounting MCB/RCCBs, DBs TP&N 4 way, 415 volts conforming to IS-2143 with minimum 200A rating copper bus bar Comprising complete all as specified and directed of following :- (i) Lighting distribution panel (ii) Incoming: - MCB , 4P 63AMP - 01 Nos (iii) Outgoing :- MCB, 4P, 32AMP -02Nos ( MCB, 1P, 6AMP - 4Nos (MCB - L&T/Schneider or equivalent make) with complete internal Bus bar & wiring up to terminals.
M&L sub main wiring with two runs of single core PVC insulated but unsheathed FRLS cable of 2.5 sqmm with multi stranded copper conductors, 1100 volts grade, IS-694 marked , drawn-through rigid steel ERW conduit (stove enameled) 20 mm dia heavy duty and including suitable size and fittings/accessories, concealed in wall and also including the one run of 2.5 sqmm earth continuity conductor of similar type cable complete all as specified and directed. Note :- Two runs of single core of 2.5 sqmm, one run of 2.5 sqmm earth continuity conductors and one run of 20mm dia ERW conduit with accessories shall be measured as one unit run length (surface conduit).
Supply & Fix & connecting totally enclosed CMRI Certified in replacement of LED flameproof wellglass suitable for hazardous area laden with gases or vapours of Group IIA & IIB and Zone 1&2. Die Cast Aluminum housing with heat resistant toughened glass cemented into a retaining ring fixed with screws to the main housing external reflector 40W including matching control gears and lamp complete all as specified and directed.
M & L for Earthing complete with Copper plate electrode 60 x 60cm x 3.15mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to copper earth strip of 20 mm x 3 mm size by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus soil and providing charcol dust & salt layers all around the earth plate upto 15 cm complete all as specified and directed. Note:- Quoted rates shall be deemed to include for copper strip with protection pipe 40m dia up to 7.5 M length.
Supply and fixing copper strips of size 20mm x 3 mm all fixing arragement such as clamps/MS screws/saddles /PVC gutka/Brass Nut bolt/Porcelain insulator & washers etc complete all as specified and directed .
Taking down of old unserviceable rubber insulated matting & prepare flooring for new matting complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats for electrical purpose as per IS 15652-2006, suitable for electrical shock safety of sizes 1 meter wide x 10m length with following specification:- (i) Thickness - 3.0 MM (ii) Maximum use voltage -33KV (iii) Ac Proof Voltage - 36 KV for 1 minutes (iv) Ac Di Electric Strength - 65 KV (v) Maximum Leakage Current - 10mA (vi) Minimum Insulation Resistance Measured by 5000V megger -1,00,000 M (vii) Minimum Tensile Strength (/MM2) - 15 (viii) Minimum Elongation (%) - 250 (ix) Minimum Retention in Tensile and Elongation from Original Value on Ageing at 70+1C for 168 Hrs - T.S Min 75%, E.L Min 75% (x) Minimum Retention in Tensile and Elongation strength from Original Value when Immersed in Acid /Alkali/Diesel & Transformer oil for 48 Hrs - T.S Min 80%, E.L Min 80% (xi) Low Temperature Resistance - YES (xii) Flame Retardance -YES (xiii) Composition - Synthetic Elastomer (xiv) Color - Blue or Black
Note:- (a) Mats shall be ISI marked at every meter. (b) Mats shall be Type tested by ERDA/CPRI or NTH. (c) Mats shall be pastable type. Pasting/Fixing on site with suitable adhesive material. (d) Test certificate shall be produceed before laying. (e) Mats shall be replaced on first sign of any damage. (f) Warranty certificate of 24 months shall be provided.
M&L for complete servicing to AHUs of Capacity 8000CFM complete with various accessories i.e. blower with casing, Chiller water coil, Hot water coil, pre filter & fine filter frame, drive motor, humidification kit, motorised control valves, control panel including descaling of chilled/hot water coils, Greasing, Lubricating of moving parts and Repair/Replacement of bush, thrust plate, gland packing, driver pully, driver shaft and re-assembling all the dismantled componenets to its original position, testing complete to the entire satisfaction of Engr-in-Charge. Note :- (i) AHU chilled/hot water coils using chemical with brass brush in-order to remove all type of sledge/dust precipitatated on the coil without any damage to the copper coil then wash the cooling with fresh water and air blower upto the satisfactory of Engr-in-Charge. (ii) Iron body of the AHU inside and outside shall be scrap down and rub out with sand paper then apply one coat primer over a coat of synthetic enameld paint including part of duct portion in the AHU shall be completed upto the satisfactory of Engr-in-Charge
Supply & fixing AHU Pre Filter of Box Type for one AHU unit, Efficiency 90% down to 20 Microns and EU-4, 04 Nos X Size 610 x 610 x 50mm Depth and CFM - 8000 as per site requirement complete all as specified and as directed. Make : Thermadyne, Camfil, Puromatic, Primide, Dyna
Supply & fixing AHU Fine Filter of Bag Type For one AHU unit , Efficiency (95% to 98%) down to 10 Microns and EU-6, 04 Nos X Size 610 x 610 x 305mm Depth and CFM - 8000 as per site requirement complete all as specified and as directed. Make : Thermadyne, Camfil, Puromatic, Primide, Dyna
Supply and fixing in replacement of digital Whirling Hygrometer Dimple (Sling Psychometer) complete all as specified and as directed.
M&L duct cleaning with vacume cleaner/ suitable device with necessary dismantaling of feasiable components and install the same of the clearity of duct to the entire satisfaction complete all as specified and as directed.
M&L for replacement of damaged insulation of chilled/hot water pipeline upto 150 mm thickness of thermo cole insulation 50 mm of density 16 Kg/Cum and insulated with thick resin bonded fiber glass and plaster by sand cement (1:3) complete suitable for above ground with all mounting arrangements like clamps with nut bolt etc, complete all as specified and as directed.
M/s KUMAR BUILDERS
Vijay Electricals
imran construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .