| 1 | Design, fabricate, supply, testing and commisioning of CPRI approved factory made LT Panel Board double door, out door type fabricated out of 3.15mm thick CRCA sheet steel for outer body and 2.00mm thick CRCA Sheet for inner partition walls, independent cabinate with cabinate doors for MCCBs, Bus Bars, cable trays, metering equipment, vertical type floor mounted on angle iron frame of 50x50x6mm with minimum height of legs 45 cm, minimum IP-54 protection, comprising of solid aluminium bus bar 4 strips suitable of 1000 Amps, suitablily grouted to PCC complete with internal wiring, epoxy powder coated, connections of cable ends with suitable size of aluminium cable lugs with the following accessories.
(a) INCOMING
(i) ACB 4 Pole, 415 V, with Thermal Magnetic
Release (Manual Fixed type) of capacity 630 Amps - 01 No
(b) OUTGOING
(i) MCCB 160 Amps, 4 Pole, 415 V, 25 KA - 04 No
(ii) MCCB 100 Amps, 3 Pole, 415 V, 25 KA - 03 No
(iii) Digital volt meter of size 4"x4" - 01 No
(iv) Selector Switch for Amp/Volt Meter - 02 Nos
(v) Current Transfer (CT) - 3 Nos
(vi) Phase indicator lamp (RYB) set of three - 01 No | 2 | Each | 100 | ₹200 |
| 2 | Design, fabricate, supply, testing and commisioning of CPRI approved factory made LT Panel Board double door, out door type fabricated out of 3.15mm thick CRCA sheet steel for outer body and 2.00mm thick CRCA Sheet for inner partition walls, independent cabinate with cabinate doors for MCCBs, Bus Bars, cable trays, metering equipment, vertical type floor mounted on angle iron frame of 50x50x6 with minimum height of legs 45 cm, minimum IP-54 protection, comprising of solid aluminium bus bar 4 strips suitable of 800 Amps, suitablily grouted to PCC complete with internal wiring, epoxy powder coated, connections of cable ends with suitable size of aluminium cable lugs with the following accessories. S/S- 01)
(a) INCOMING
(i) MCCB 350 Amps, 4 Pole, 415 V, 36 KA - 01 No
(b) OUTGOING
(i) MCCB 125 Amps, 4 Pole, 415 V, 25 KA - 04 No
(ii) Digital volt meter of size 4"x4" - 01 No
(iii) Selector Switch for Amp/Volt Meter - 02 Nos
(iv) Current Transfer (CT) - 3 Nos
(v) Phase indicator lamp (RYB) set of three - 01 No | 2 | Each | 100 | ₹200 |
| 3 | Design, fabricate, supply, testing and commisioning of CPRI approved factory made LT Panel Board double door, out door type fabricated out of 3.15mm thick CRCA sheet steel for outer body and 2.00mm thick CRCA Sheet for inner partition walls, independent cabinate with cabinate doors for MCCBs, Bus Bars, cable trays, metering equipment, vertical type floor mounted on angle iron frame of 50x50x6 with minimum height of legs 45 cm, minimum IP-54 protection, comprising of solid aluminium bus bar 4 strips suitable of 400 Amps, suitablily grouted to PCC complete with internal wiring, epoxy powder coated, connections of cable ends with suitable size of aluminium cable lugs with the following accessories.
(a) INCOMING
(i) MCCB 200 Amps, 4 Pole, 415 V, 36 KA - 01 No
(b) OUTGOING
(i) MCCB 125 Amps, 4 Pole, 415 V, 16 KA - 01 No
(ii) MCCB 100 Amps, 4 Pole, 415 V, 16 KA - 03 No
(iii) MCCB 63 Amps, 4 Pole, 415 V, 16 KA - 02 No
(iv) Digital volt meter of size 4"x4" - 01 No
(v) Selector Switch for Amp/Volt Meter - 02 Nos
(vi) Current Transfer (CT) - 3 Nos
(vii) Phase indicator lamp (RYB) set of three - 01 No | 3 | Each | 100 | ₹300 |
| 4 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 185 Sqmm 3.5 core all as specified and directed. | 76 | RM | 100 | ₹7,600 |
| 5 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 120 sqmm 3.5 core all as specified and directed. | 320 | RM | 100 | ₹32,000 |
| 6 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 50 Sqmm 3.5 core all as specified and directed. | 300 | RM | 100 | ₹30,000 |
| 7 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 35 Sqmm 4 core all as specified and directed. | 100 | RM | 100 | ₹10,000 |
| 8 | M&L for Precast concrete cable cover class LV Type 1, flat, size 250mm 150mm x 40mm , ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed. | 4,245 | Each | 100 | ₹4,24,500 |
| 9 | Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable incl spreading, levelling, watering and consiolidation, thickness 18 cm after punning complete all as specified and directed. | 52 | Cum | 100 | ₹5,200 |
| 10 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge. | 2 | Cum | 100 | ₹200 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.89 MB
Tender.pdf
Tender Documents • 6.44 MB
BOQ_886233.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .