Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 LAccepted-AOC HEMANTA BASU PALLY SAINTHIA BIRBHUM | SAINTHIA | BIRBHUM | WEST BENGAL | 731234 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹1.3 L+₹903 (0.70%)Rejected-Finance 107 FCI GODOWN ROAD PO PS SAINTHIA BIRBHUM WEST BENGAL 731234 | SAINTHIA | BIRBHUM | WEST BENGAL | 731234 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹1.3 L+₹1,470 (1.13%)Rejected-Finance INDIRA HATIA BIRBHUM | BIRBHUM | BIRBHUM | WEST BENGAL | L3 | Rejected-Finance BEING L3 BIDDER |
Tender Value
Refer Docs
EMD Value
₹2,626
Closing Date
25 Sept 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
E.E P.W.DTE BIRBHUM ELECTRICAL DIVISION
OFFICE OF The EXECUTIVE ENGINEER P.W.DTE. Birbhum Electrical Division P.O. Suri Dist Birbhum Pin 731101
Electrical Repairing Works for toilet area of various ward like Gynae Post Natal II mother Room Paediatric Ward etc due to civil renovation at the Suri Sadar Hospital in the District of Birbhum.
2024_WBPWD_750981_1
BIRED/99/e-NIQ (1st call) of 2024-2025
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
SURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,626
OFC OF THE E.E P.W.DTE BIRBHUM ELECTRICAL DIVISION
25 Mar 2025
13 Sept 2024
27 Sept 2024
13 Sept 2024
25 Sept 2024
17 Sept 2024
17 Sept 2024
Amount
SUB-HEAD 1--DISTRIBUTION WIRING. Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire do---do---do on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]. Average run 6 Mtr.
SUB-HEAD 2--CUTTING CHANEL & WIRE LAYING. Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works. i) 20 mm size
ii) 25 mm size
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2x(6 sqmm) + 1x(4 sqmm) as ECC
Supplying & Fixing solderless Copper socket by crimping of Copper wires. a) 4 sq mm
b) 6 sq mm
SUB-HEAD 3. SPNDB, M.C.B etc. Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+8 Way[ Legrand ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ] 40 A DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS (Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. 6-32 SP
SUB-HEAD 4--FIXING OF LIGHT FITTINGS. Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps as per GS.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Fixing only lamp
SUB-HEAD 5--SUPPLY OF INTERNAL LIGHT FITTINGS. Supply and delivery of Single Industrial type LED luminaries with aluminium extrusion heat sink incl. Supply of 1nos. 18W LED Tube with LED Batten. [Make- SURYA , 1xT-8 cat no.- SLE TL DS 18 P AL EXT & SUB 118 T8 LED or equivalent Magik/ Philips/ CG / Bajaj / Wipro/Havells as approved by E.I.C]
Supply of 14W LED bulb (Magik/surya/ Bajaj/ CG/ Philips/ wipro) on existing batten holder
SUB-HEAD 6--FIXING OF FANS. Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter. For 23 cm (9") Exhaust fan.
For 30 cm (12") Exhaust fan.
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long). For 23 cm (9") Exhaust fan
For 30 cm (12") Exhaust fan.
SUB-HEAD 7--SUPPLY OF Exhaus FANS. Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC ) i) 9" ( 230mm ) Speed 1370 RPM
ii) 12" ( 300mm ) Speed 1420 RPM
N.B: i) Payment will be made after availability of fund from concern Department. ii) Payment will be made as per P.W.D norms.
M/S. S. D. CHATTERJEE AND CO. (BID ID -5599336)
B M ELECTRIC (BID ID -5599143)
technical_1659792.pdf
PDF • 0.40 MB
techsummary_1659792.pdf
PDF • 0.49 MB
finance_1659792.pdf
PDF • 0.42 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1659792.pdf
PDF • 0.97 MB
AOC99.pdf
PDF • 0.94 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .