| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹23.2 L+₹1.2 L (5.39%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹28.0 L+₹5.9 L (27.0%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹28.3 L+₹6.3 L (28.4%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹28.6 L+₹6.6 L (29.9%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹67,940
Closing Date
26 Apr 2025, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
MAINT OF LT FEEDER PANELS AND VARIOUS LT BREAKERS INCL RERPLACEMENT OF OLD EARTHING UG CABLES OF MD AND OTM ACCN AT EME WKSP, QMTI MAP AND RH AND REP AND MAINT INCL REPLACEMENT OF SPARE AND SERVICING OF FIRE HYDRANT PUMPS AND FIRE WATER MAINS AT MH
2025_MES_702884_1
8657/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹67,940
Yes
5 Jun 2025
28 Mar 2025
28 Apr 2025
28 Mar 2025
26 Apr 2025
12 Apr 2025
28 Mar 2025 - 19 Apr 2025
Amount
Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 50x50x6mm with bottam of panel having minimum 60cm height from existing ground/floor level.
Aluminium bus bar strips with proper colour code -04 No, 400 A cap, insulator, nuts bolts etc complete.
Indicator Lamp-01 Set (Set of three)
Incommer MCCB 4P 315 Amp, 415V, 36 KA Ics = 100 Icu Adjustable type - 01 No
Outgoing, MCCB 4P 160 amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 02 No ( 01 for RH Bunglow panel and 01 nos spare MCCB)
Outgoing, MCCB 4P 125 amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 01 No
Outgoing, MCCB 4P 63 amp, 415V, 16 KA Ics = 100 Icu Adjustable type - 02 No (for Aashray Bldg DB's)
Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles.
Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 50x50x6mm with bottam of panel having minimum 60cm height from existing ground/floor level.
Aluminium bus bar strips with proper colour code -04 No, 300 A cap, insulator, nuts bolts etc complete.
Indicator Lamp-01 Set (Set of three)
Incommer MCCB 4P 250 Amp, 415V, 36 KA Ics = 100 Icu Adjustable type - 01 No
Outgoing, MCCB 4P 125 amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 05 No
MCB TPN 32A,10KA B CURVE - 01 Nos for Street light panel
Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles.
Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 50x50x6mm with bottam of panel having minimum 60cm height from existing ground/floor level.
Aluminium bus bar strips with proper colour code -04 No, 400 A cap, insulator, nuts bolts etc complete.
Indicator Lamp-01 Set (Set of three)
Incommer MCCB 4P 315 Amp, 415V, 36 KA - 01 No Ics = 100 Icu Adjustable type - 01 No
Outgoing, MCCB 4P 250 amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 03 Nos
Outgoing, MCCB 4P 160 amp, 415V, 25 KA - 01 No Ics = 100 Icu Adjustable type
Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles.
Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 50x50x6mm with bottam of panel having minimum 60cm height from existing ground/floor level.
Aluminium bus bar strips with proper colour code -04 No, 300 A cap, insulator, nuts bolts etc complete.
Indicator Lamp-01 Set (Set of three)
Incommer MCCB 4P 400 Amp, 415V, 36 KA Ics = 100 Icu Adjustable type - 01 No
Outgoing, MCCB 4P 250 amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 02 No (for Ashok Nagar panel 01 nos spare)
Outgoing, MCCB 4P 160 amp, 415V, 25 KA Ics = 100 Icu Adjustable type - 01 No (for KG School)
Outgoing, MCCB 4P 63 amp, 415V, 16 KA Ics = 100 Icu Adjustable type - 05 No (for Bldg Panels BDTC area)
MCB TPN 32A,10KA B CURVE - 01 Nos for Street light panel
Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles.
Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 50x50x6mm with bottam of panel having minimum 60cm height from existing ground/floor level.
Aluminium bus bar strips with proper colour code -04 No, 300 A cap, insulator, nuts bolts etc complete.
Indicator Lamp-01 Set (Set of three)
Incommer MCCB 4P 160 Amp, 415V, 36 KA Ics = 100 Icu Adjustable type - 01 No
Outgoing, MCCB 4P 63 amp, 415V, 16 KA Ics = 100 Icu Adjustable type - 04 No (02 for bldg panel BDTC area and 01 for KG school bldg panel and 01 nos spare)
Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles.
Note : (i) Electrical connection from switchgear to bus bar would be through copper strips of suitable size. (ii) The internal electrical connection for measuring instruments would be through multi-stranded PVC insulated copper conductor cables of suitable size. (iii) The termination of incoming and outgoing cable into and from switchgear would be through properly crimped aluminum lugs of suitable rating incommensurate with that of switchgear. (iv) Cable glands would be provided for incoming & out going cables in panels. (v) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (vi) The panel is to be fixed with Angle Iron Frame of size 65x65x6mm with bottam of panel having minimum 60cm height from existing ground/floor level.
Aluminium bus bar strips with proper colour code -04 No, 800 A cap, insulator, nuts bolts etc complete.
Indicator Lamp-01 Set (Set of three)
Incommer MCCB 4P 630 Amp, 415V, 50 KA - 01 No Ics = 100 Icu (Adjustable type TM MCCB range) - 01 No
Outgoing, MCCB 4P 400 amp, 415V, 36 KA Ics = 100 Icu Adjustable type - 03 Nos (01 no for MT area Panel and 01 no for Aaya qtr panel and 01 nos spare)
Outgoing, MCCB 4P 315 amp, 415V, 36 KA - 01 No Ics = 100 Icu Adjustable type - 01 Nos (for proposed Helipad area panel)
Connection with Aluminium bus bar strip duly insulated with coloured sleeves /stranded copper cable of suitable size with thimbles.
M & L in replacement Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to 32x6 mm GI strip as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 50 MM dia GI pipe light grade for protection of wire/strip etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
Supply, installation and commissioning of advance maintenance free system based earthing comprising of following accessories (a) Set of 04 Nos 3000 mm long, 17.0 mm dia earth electrode made of 99.99% copper circular rods with connect copper strip and electrode with the help of copper brazzing of incoming copper strips of size 25 x 3 mm of length as per site requirement upto Bus bar as decided by Engr - in-Charge and distance between each copper earth electrode is minimum 3 Meter . (b) Copper bus bar of size (300 x 25 x 6)mm act as test point connect with copper nuts and bolts with post insulator.(Nuts/bolts as required is included in the cost). (c) Poly propylene earth pit cover of size 300 x 300 mm (with safe working load 2000 Kg) - 04 Nos (d) Copper bus bar of size (250 x 50 x 6)mm exothermically welded with main earth electrode (e) Each pit filled with earth enhancement compound /chemical (Magnesium sulphate) only (min 75 Kgs/pit) all as specified.
(f) Required result of earthing less than 01 Ohm . If desired Ohmic value is not achieved then additional set of 1 No of 3000 mm long, 17.0 mm dia earth electrode made out of 99.9% copper rod with allied items, 01 x Pit cover, 01 x Sub bar as (d) above 75 Kg of chemical shall be provided by contractor without any extra cost to Govt. No price adjustment shall be made, if additional set is not required complete all as directed of Engr- in-charge (g) Necessary excavation work in any type of soil/strata, returning filling and removal of soil is included in the aquoted rates. (h) Site inspection for complete Earthing work is mandotry for the Contractor befour quoting the tender. No explanation/doubts will be entertained later. (j) Any damage done to govt property during the execution of work will be make good by the contractor at his own cost.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable in replacement with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by Enginner in -Charge for following sizes . Make :- Havells / Gloster / Finolex / Polycab
300 sq mm 3.5 core .
240 sq mm 3.5 core
185 Sqmm 3.5 core
150 sq mm 3.5 core
95 sq mm 3.5 core
70 sq mm 3.5 core
50 sq mm 3.5 core .
35 sq mm 3.5 core
25 sq mm 3.5 core
16 sq mm 4 core
NOTE :- Earth work , bricks , riddled earth , GI pipe for protection of cable will be measured & paid under under relevant items of schdule .
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying pipes complete and getting out :-
Soft/Loose soil
Hard/dense soil
Hard Rock
Removing excavated material soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
M & L for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed. Note - Punned thickness shall only be measured & paid .
M& L for road cutting / foot path and making good with PCC 1:3:6 TYPE C-2 ( using 40 mm graded stone aggregate ) of 150 mm
Supply and laying un-reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mm for Under ground cable all as specified and directed.
Supply and laying GI tubes light grade, galvanized, 40 mm bore in repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed
All as per item No -16 but 80 mmm bore.
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size 25 to 50Sqmm 3.5/4 core cable complete all as directed .
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 70 up to 120 sq mm3.5/4 core cable complete all as directed .
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 150 to 185 sq mm 3.5/4 core cable complete all as directed .
Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 240 to 300 sq mm 3.5/4 core cable complete all as directed .
M&L for cleaning of MES electric supply installations/campus by surface dressing or trimming of natural ground to remove small unequalities not exc 15 cm deep (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away complete at an interval of every 30 days for the various sub stations. Note: Spray of herbsite deemed included in quoted rate.
M&L for servicing of electric motor of capacity 120 HP, 3 Ph, 415 volt, cleaning of winding, removing of dust, varnishing and greasing of ball / roller bearing complete and refixing the same in position with proper balancing and allignment including testing all as directed by Eng-in-charge.
M & L for painting of motor coupled pump for removing the existing deteriorated paint by scrapping the complete body, filling cavities with filler, spray painting with synthetic enamel paint two coats over a coat of red oxide zinc crome primer and marking of SM/MES No. with black paint for 120 HP pump.
M & L for painting of motor coupled pump for removing the existing deteriorated paint by scrapping the complete body, filling cavities with filler, spray painting with synthetic enamel paint two coats over a coat of red oxide zinc crome primer and marking of SM / MES No. with black paint for 60 HP pump.
S&F Pressure gauge with 8'' dial and 0-21 kgs rating including taking down old unserviceable gauge complete all as directed by Engineer In Charge.
S&F Non return valve CI with bypass arrengement and GI pipe 20mm dia and gatevalve etc , Double flanged swing type as per IS-5312 (Part I) of pressure rating PN 1.6, 200mm single Door type incl removal of old gasket , nutbolts etc & removal of Unsv NRV all as specified and directed.
S & F in replacement cast iron Foot valve of confirming to IS 4038, all as specified and directed of size 200mm dia.Make KIRLOSKAR/ LEADER/ KARTAR/ NORMEX
Material & labour for attending breakdown of fire fighting pipe lines upto 300mm dia, bursting/cracks including broken pipe pieces of various sizes through gas cutting or manual cutting as required at site and providing new CI/MS pipes of required length (not more than 2m) and removing out the damaged CI pipe and inserting necessary specials such as CI flange collar MS cut pieces etc as required at site and providing 4 Nos of flange joints required at site if required including testing for the leakages of lead joints for 200/150mm dia MS/CI pipes complete all as specified and directed by Engr-in -charge Note: The rates are also inclusive of Excavation in any type of strata , returning and refilling.
M&L for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding of the motor and rewinding the same with super enamelled copper wire 'H' Class of same size to get the same output of motor including materials such as varnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacity 120HP all as specified and directed.
Repairs to CI Non return valves flange type of size from 150mm dia to upto 200 mm dia by opening the cover and cleaning the valve by removing all scales, dirt etc and reassembling the valve with new packing nut and bolts including painting with one coat of synthetic enamel paint all as directed by the Engineer-in-Charge for the following:
M&L in replacement of butterfly valve slim seal standard lever operated type confirming to IS -13039 of following sizes, with replacement of required flanges, nuts bolt, handle etc - CI Heavy ISI--to suit the system including taken down unserviceable accessories all as directed by Engineer In Charge. Make kirloskar/ jindal/Kartar
Supply and fix maintainecnce free batteries of capacity 12V 180 AH for fire fighting Engine all as specified
Painting of fire control cabinet indoor type size 2 x 1.5 x 0.9 meter with two coats of paint over a coat red oxide primer by spray paint including scrapping out old rusted paint complete all as directed by Engineer-in-Charge
Replacement of unserviceable/broken glass & rubber beading in cabinate all as directed by Engineer In Charge
Replacement of unserviceable key & lock in cabinate all as directed by Engineer In Charge
Painting fire hydrant pipe line up to 200 mm dia by scrapping old rusted paint and applying one coat of red oxide primer and two coats of synthetic enamel paint of fire red colour including marking fire hydrant flow all as specified and as directed Note :- The rates are inclusive of T&P involved in painting the Fire line at any heights in hospital bldg.
Construction of valve pit in repairs of size 120x120x60cm internal dimensions with 100 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate for sub base of floor, 50mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in floor, finished even and fair without using extra cement , PCC solid block masonry in CM 1:4, rendering with15 mm thick plaster in CM 1:4 including 3 mm thick MS sheet pit cover fixing with angle iron frame 40x40x6 mm thick complete with locking arrangement having provision of lifting handle including 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surface including excavation in soft/loose soil, returning filling and removal of surplus soil up to 50m distance complete and all as specified and directed by Engr-in- Charge.
Taking up old pipe line (cast iron/MS) including all fittings, with flange ends and joints complete of following sizes:-
200 mm dia
150 mm dia
100 mm dia
80 mm dia
M & L for MS ERW Pipes of following size including all specials in any lengths & welding , cutting , bending etc complete laid in trenches/on wall all as specified and directed .
200 mm dia
150 mm dia
100 mm dia
80 mm dia
Supply and Fix in replacement of Flanged stand post CI of 80mm dia 1.5m height all as specified and directed including PCC plateform
Supply and Fix in replacement Electrically operated Siren Horizontal mounting, with 2 kilometers range Single Phase 200/250Volts, 6000 RPM, 50 Hz AC model no - SS200. Make :- Kheraj or equivalent
Supply & Fix in replacement of single type fire hydrant landing valve type A ( Single headed outlet) of 63mm dia size all as specified and directed by Engr-in-charge.
Supply & Fix in replacement of single type fire hydrant landing valve type A ( Double headed outlet) of 63mm dia size all as specified and directed at by Engr-in-charge.
Supply and Fix in replacement of Hose box made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside yard complete all as specified and directed.
All as per item No 45 above but internal type all as specified and directed
Supply and Fix in replacement of hose reel of 15/20mm dia and 30 mtrs long confirming to IS 5132 all as specified and directed
Supply and Fix in replacement of Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short all as specified and directed
Supply and fix in replacement of 63mm dia 15 mtr long hose confirming to IS 636 complete with male and female coupling confirming to IS 903 all as specified and directed
Supply and Fix Sluice Valve 200 mm bore size type 1.6 PN with MS Spindle including taking out old sluice valve complete all as specified and directed
Supply and Fix Sluice Valve 150 mm bore size type 1.6 PN with MS Spindle including taking out old sluice valve complete all as specified and directed
Supply and Fix Sluice Valve 100 mm bore size type 1.6 PN with MS Spindle including taking out old sluice valve complete all as specified and directed
Material and Labour for Mild Steel brackets, frames ,supports, I channels and stands of type as required at site made out of angle iron, flat or strip of grade, MS plate Fe-410-S of any size as per site requirement for fixing fire fighting pipes to wall, roofs, ducts etc complete all as specified and as directed by Engr-in-charge .
Cleaning of RCC underground/semi underground watersupply sump, static water tank of capacity Exceeding 10,000 GLNS to 30,000 GLNS by dewatring and taking out all scales,dirts, mud. algae etc from inside the tank and from mouth of circulating pipes includinand taking out sludge with help of sludge pump of suitable capacity including washing of tank wall with bleaching powder solution and then with water and draining out sludge, water completely
Note : (i) Cleaning should be done by scraper and removing dirt with brush and washing with bleaching powder all as directed by Engr-in-Charge. (ii) The inlet and outlet / over flow pipe of sump should be cleaned properly and care should be taken to prevent entry of sludge into pipe line by blocking mouth of pipe. Any blockage of the inlet / outlet / overflow pipe line shall be cleaned by contractor at no extra cost. (iii) Date of cleaning 'CLEANED ON ___________ NEXT due DATE ______________' should be painted with black and white paint as per Existing size. (iv) Tank / Sump capaciting 'CAPACITY ________ GLNS' should be painted on tank as per existing size. (v) Painting of all pipes & MS items with matching with the existing colour.
PURVA ELECTRICALS AND ENGINEERS (BID ID -3284882)
M/s Harshal Traders (BID ID -3284826)
Adinath Technical Services (BID ID -3284495)
M/S kirpan Enterprises (BID ID -3284900)
SBS Enterprises (BID ID -3284647)
Mahindra Electric Stores (BID ID -3283967)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .