PROVN OF UPGRADATION OF EXTERNAL ELECTRIFICATION SERVICES IN SHAUGAON TRG AREA AT BAGRAKOTE MIL STN UNDER GE SEVOKE ROAD
2021_MES_424956_4
8010/BIN/(SEV)/ 89 OF 2020-21
Open Tender
Civil Works
Item Rate
90 days
BAGRAKOTE MIL STN
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SEVOKE ROAD
₹18,000
Yes
26 Jun 2021
4 May 2021
1 Jun 2021
4 May 2021
31 May 2021
18 May 2021
Amount
Schedule 'A'
Excavation in trenches n exc 1.5m wide and n exc 1.5m depth for foundation etc. and getting out in hard/dense soil completed all as specified and as directed.
Surface dressing n exc 15cm deep in hard/dense soil completed all as specified and as directed.
M&L for PCC 1:4:8, type D2 (using 40 mm graded agg) as in foundation, filling and mass concrete completed all as specified and as directed.
M&L for brickwork with sub class `B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 completed all as specified and as directed.
M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 completed all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in hard/dense soil completed all as specified and as directed.
Removing excavated materials to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point completed all as specified and as directed.
M&L for 40 mm thick PCC 1:2:4, type B0 (using 12.5 mm graded stone agg) for DPC to horizontal or vertical surfaces including necessary form work incl mixing WPC as per manufacturer's instructions completed all as specified and as directed.
M & L for hardcore of broken stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface completed all as specified and as directed.
M&L 100mm thick PCC 1:4:8, type D2, using 40mm graded aggregate as in sub base completed all as specified and as directed.
M&L 50mm thick PCC 1:2:4, type B1 (using 20mm graded agg) as in floor and paving completed all as specified and as directed.
M&L for dividing glass strips, 3mm thick and inserted in position to conform to design completed all as specified and as directed.
S&F for Steelwork in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161 - 1979 Grade St - 240 (Including preparation of surface and one shop coat of zinc chromate primer paint) at contractors workshop before fabrication completed all as specified and as directed.
S&F mild steel screw bolts, 5 to 10mm dia (machine made) with hexagonal head at one and screwed the other or screwed both, each screwed end to be fitted with one washer and one hexagonal or square nut, exc 5 cm n exc 10 cm. completed all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self drilling and self tapping screws, neoprene and limpet washers complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self drilling and self tapping screws, neoprene and limpet washers complete all as specified and directed.
S&F Mild steel flat iron for wind ties, incl drilling holes, securing bolt etc. and similar work conforming to Fe-290 Gde-E 165 completed all as specified and as directed.
M&L rendering 15mm thick in CM 1:6 on fair faces of brick or concrete surfaces finished even & smooth w/o using extra cement completed all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including mixing WPC as per manufacturers instruction, finished even and smooth w/o using extra cement completed all as specified and as directed.
Supply only integral water proofing compound completed all as specified and as directed.
Preparation of new plaster surfaces and applying three coats of white wash on wall completed all as specified and as directed.
M&L 75mm thick cement concrete 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection & paving, finished even & smooth without using extra cement completed all as specified and as directed.
Preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer completed all as specified and as directed.
S&F pressed steel frames (Size-165X60mm) for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate etc completed all as specified and as directed.
S&F factory made 2nd class hard wood rail and style 35mm thick plain framed, panelled shutter (two panel ) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 (part I), kiln seasoned and chemically pressure treated completed all as specified and as directed.
S&F 300 mm long mild steel sliding door bolts plate type stove anamelled black with bright bolts not less than 12mm dia with including a minimum of 6 bolts nut four on bolts plate & two on staple plate completed all as specified and as directed..
S&F mild steel pressed handle oval type stove enamelled black 150 mm long completed all as specified and as directed.
M&L for preparation of new untreated wood and wood base material of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer completed all as specified and as directed.
M&L PCC 1:2:4, type B0 (using 12.5mm graded aggregate) as in copings, kerbs and the like incl weathering, slightly rounded or chamfered angles and throating, as directed incl necessary form work as reqd completed all as specified and as directed.
S&F for polished chequered cement concrete tile 30 cm x 30 cm x 25 mm thick set, jointed and pointed in neat cement slurry in floor with grey cement and pigments complete all as specified and directed.
Point wiring for light/fan/call bell etc. controlled by one switch with 1.50 Sqmm (nominal area) FRLS PVC insulated 1100 volts grade multi stranded copper conductor single core unsheathed cable drawn through and unsheathed single core solid copper conductor cable of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, including rigid PVC concealed conduit (Medium Grade) of suitable size, with all fittings and accessories including provision of mild steel terminal boxes of suitable size made with 1.2 mm thick mild steel sheet duly galvanised, for fixing switches / sockets / regulators etc. fixed in recess of wall with brass chromium plated screws and cap washer complete for one light / fan point controlled by one switch completed all as specified and as directed.
S&F Switch piano flush type, single pole, one way, 5/6Amp complete all as specified and as directed.
S&F Ceiling rose, 3 terminals, PVC/polycarbonate, isolated body complete all as specified and as directed.
S&F LED tube light fitting 20 watt complete all as specified sand directed.
S&F Sheet Metal enclosure for SPN DBs,2 Ways, complete suitable for 240 Volts, AC, 50 Hz supply, and fixed in recess in brick masonary wall completed all as specified and as directed.
S&F SPN MCB of capacity 32 Amps, 240 volts, complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm completed all as specified and as directed.
Supply and fix lightning arrestor non linear resistor type conforming to IS 3070 (part-3) 1993 complete line discharge class -3m, nominal discharge current 10KA peak, 12 KV rated system, voltage peak value high current impulse 4/3micro Sec, assembly suitable for 11KV HT 11 KV 65 KA station class completed all as specified and as directed.
Supply and fix HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 12 insulators of rating upto 200 Amps including expulsion fuse single pole for each phase including necessary operating pipe, clamp for fixing and operating handle complete all as specified and directed
Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.0 metres long) completed all as specified and as directed.
M&L in repair for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completed all as specified and as directed.
M&L in repair for earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completed all as specified and as directed.
Supply installation, commissioning and testing of transformer copper wound step down 100 KVA outdoor type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed naturally cooled, delta connected on HV side and star connected in LV side in accordance with vector symbol DY-II with neutral brought out on secondary side and having tapping in step of ± 2 ½ %, ± 5% and ± 7 ½ % to be changed by mean of hand operated OFF load tap changing gear including first fill of transformer oil as per IS-335, and including all fittings/accessories as specified in SSR Part I and IS-2026, the transformer should have cable box on LT side and brass bushings on HT side, oil temperature gauge, dehydrating breather with first fill of dehydrating agent, oil conservator tank, explosion vent, rating and terminal marking plate, oil level gauge, oil drain and filter valve, providing independent earthings and neutral fittings, lugs and two earthing terminal etc,complete in all respect and all other standard accessories all as specified comprising with the following:- (i) 01 No cable box on LT side consisting of 03 Nos porcelain bushing with bushing brass rod and nuts washers etc. (ii) HV bushing with arching horn on 11 KV side. (iii) Oil conservator with filter type drain valve and oil level fuage. (iv) Dehydrating breather with first filling of Dehydration agent. (v) Explosive vent. (vi) Thermometer pocket. (vii) Two Earthing terminal on tank body to facilitate fixing of 32x6 mm GI strips. (viii) One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge: Max reading painted terminal. (ix) Rating plate with terminal plate. (x) Oil level guage . (xi) Oil draing filter valve. (xii) Oil filing port on top cover with plug. (xiii) Air release valve/plug. (xiv) 4 Nos plain sold cast steel detachable rollers. (xv) Shut of valve between conservator and bucholz relay. (xvi) First fill of transformer oil conforming to relevant ISI and tested upto 60 KV dielectric strength. (xvii) Inspection cover. (xviii) Lifting lugs and jack lifting pad support. (xix) Bi-directional plan/falnged rulers. (xx) Explosion vent with double diaphragm and sight glass. (xxi) Hand hole of sufficient size to assess the interior of the tank. (xxii) Cover lifting eyes. (xxiii) Double float bucholz relay with trip and alarm contacts. (xxiv) Necessary fencing, gate and gravel filling in switch yard area all as directed. Note:- (i) Transformer shall be fixed on two pole structure all as specified. (ii) The contractor shall arrange factory visit as detailed by accepting officer to check the above system.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core completed all as specified and as directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint completed all as specified and as directed.
Excavation in trenches not exc.1.5 mtr in width & depth for laying of pipe/cables of various size and getting out in soft / loose soil completed all as specified and as directed.
Excavation in trenches not exc.1.5 mtr in width & and exceeding 1.5 mtr to 3.0 mtr depth for fixing of poles of various size and getting out in soft / loose soil completed all as specified and as directed.
Returning ,filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil completed all as specified and as directed.
Removing excavated soil/material not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point completed all as specified and as directed.
M&L for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. (Punned thickness shall be considered for payment).
M&L for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class"B" laid dry and flat and width wise along the axis of the trench complete all as specified and as directed by Engineer-in-Charge.
M&L for P.C.C. 1:4:8 (Type D-2,40mm graded aggregate) as in foundation filling or for mass concrete of poles,stays,struts or any other indicated work including form work(if required) complete all as directed by Engr-in-Charge
M&L for P.C.C. 1:2:4 (Type B-1,20mm graded aggregate) for coping of poles / platform of feeder pillar box or any other indicated work including form work(if required) duly plastered and making the surface smooth and even by using extra cement complete all as directed by Engr-in-Charge
Supply, installing, testing and commissioning out door type LT feeder pillar box of suitable size, pedestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : (FPB near Bus Bar OR Living) BUSBAR :- 150 Amps rated Aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance INCOMING:- (i) MCCB 4P of capacity 100 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16KA with thermal magnetic release -01 No (ii) 3 Ph digital volt meter Class 1, 0-500 volts, 3 Phase, 4 digi with LED display-- 01 No (iii)3 Ph digital Ampere meter Class 1 accuracy , 0.5 VA burden with LED display-- 01 No (iv) Modular indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (v) CT (100/5A) -03 Nos OUTGOING:- (i) MCCB 4P of capacity 80 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16KA with thermal magnetic release -03 No (i) MCCB 4P of capacity 63 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16KA with thermal magnetic release -02 No (a) MCB 4 Pole of capacity 32 Amp , breaking capacity 16 KA with thermal release -4 Nos (b) MCB 2 Pole of capacity 6-32 Amp , breaking capacity 10 KA with thermal release -7 Nos (c) Time Switches astro type (having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp Rating With 3 phase 63A Contactor fitted inside steel enclosure
S&F cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 95 Sqmm completed all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for LT side transformer complete with Jointing material cold Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 95 sqmmsqmm,Indoor/Outdoor type completed all as specified and as directed.
M&L for aluminium conductor steel reinforced (ACSR) of size as directed by Engr -in-Charge duly binded with the insulators joined for the overhead lines complete all as directed by Engr-in-charge
S&F GI pipe 80mm bore light grade with all fittings for passing of cables fixed to pole/wall/laid under floors or roads including all fixing accessories complete all as specified and as directed
M&L for ant climbing device spikes type fabricated out of MS bars (round square and flat) including nut bolts washer and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed
M&L pin type porcelain vitreous white brown or green insulators including one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nut, 150mm dia for 150volts, 11KV complete all as specified and directed
M/s. MD IRSHAD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .