RequiredOEM Authorization Certificate Bid to RA enabled No ICU Bed ( 15 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standard Parameter Conformity to standard for safety & electromagnetic compatibility IEC-60601-1-2:2001 Standard or IS-13450 IEC-60601-1-2:2001 Standard or IS-13450 Performance Parameter Purpose ICU Bed are required to be used in Intensive Care Unit for comfort of Patient & facilitate comfortable transfer to & from Emergency/OT Ward etc. & also to ICU Bed are required to be used in Intensive Care Unit for comfort of Patient & facilitate comfortable transfer to & from Emergency/OT Ward etc. & also to 1/8 carry out point of care process including Radio- logical procedure at bed side carry out point of care process including Radio- logical procedure at bed side Type of ICU Bed Actuator Electro-Mechanical (Motorized ) Mechanical (Handle Operated)
RequiredElectro- Mechanical (Motorized )
RequiredHydraulic Actuator (Pump/Compressor Operated) Type of mechanism for functioning or controlling angular motion of bed part Hydraulic mechanism (Motorized) Super Smooth Crank Screw Mechanism
RequiredHydraulic mechanism (Motorized) Type of mechanism for functioning or controlling Height of bed Counter weight mechanism Super Smooth Crank Screw Mechanism
RequiredHydraulic mechanism
RequiredCounter weight mechanism Number of section provided in Bed Top 4 * Base frame and support frame should be fabricated using metallic square rectangular section of adequate cross section and thickness to provide high structural strength and stability Yes * Bed top perforated Yes Yes
RequiredNo Bed should have radio translucent top (X-Ray translucent) No Yes
RequiredNo Availabilty side panel/Side safety guard Yes * Type of side panel Swing Up Down type Collapsible type
RequiredSwing Up Down type
RequiredDetachable type
RequiredCollapsible & Detachable type Number of Side panel 4 1
Required2
Required3
Required4 Availability Head & Foot panel/Board Yes * Shape of Head & Foot panel/Board B-type shape B-type shape
RequiredC-type
RequiredD- type Type of Head & foot Panel Detachable type Detachable type
RequiredSwing Up Down type Material of head and ABS (acrylonitrile- * 2/8 foot panel butadiene styrene) Availability of good grip for head/foot or side panel Yes * Slots for IV rod at four corners provided Yes * Number of hooks provided in IV rod 2 2
Required4 Availability of rectangular telesccopic tube box housing for tension spring Yes Yes
RequiredNA for Super Smooth Crank Screw Mechanism & Hydraulic mechanism for height Degree Angle & Height indicator shall be provided at both foot & head side Yes Yes
RequiredNo X-Ray film holder used from Both side One side
RequiredBoth side Type of X-Ray Film holder Cassettle Based System * Power of motor in HP(for non motorized put NA) 0.5 hp 0.5 hp
Required0.7 hp
Required0.8 hp
RequiredN/A Better quality bearing should be used Yes * Avaiability of patient constraint belt provided on both side of bed No yes
RequiredNo Availability of Noiseless
Requirednon rusting swivel castor wheel roller with for easy Mobility & Steering yes * Facility of braking and locking mechanism provided in castor roller Yes * Number of caster to which braking system provided 2 2
Required3
Required4 Availiability Corner buffer in all four corner to protect patient from collision shock Yes * Safe working load capacity of ICU bed in kg 200 150
Required200
Required250
Required120
Required170 3/8 Facility of instant non powered/mechanical CPR( Cardiopulmonary Resuscitation) release at the head end for emergency Yes * Lilen Holder/Urine Bag holder provided Yes * Accessory Rail Provided at all four side of bed Yes * Mattress provided with ICU bed No Yes
RequiredNo ICU mattress must X- ray translucent NA (If mattress is not provided) Yes
RequiredNA (If mattress is not provided) Mattress foam of the Bed should be with Anti Microbial agent incorporated into all components that assists in Prohibiting growth of bacteria & fungi and easy to clean NA (If mattress is not provided) * Mattress shall be made of High resilient & bio- density foam NA (If mattress is not provided) Yes
RequiredNA (If mattress is not provided) Mattress should be translucent to allow radiography using portable X-ray machines NA (If mattress is not provided) Yes
RequiredNA (If mattress is not provided) Mattress should be made in cube cut design & independent cubes promote air flow to reduce moisture NA (If mattress is not provided) Yes
RequiredNA (If mattress is not provided) Material for ICU Bed Mattress NA (if mattress not provided) Latex Foam
RequiredPU Foam
RequiredNA (if mattress not provided) Maximum thickness of Mattress in mm with tolerance of ± 2 mm NA (if mattress not provided) * Approx foam Density for Head/sacrum in kg/m3 tolerance NA (if mattress not provided) * Approx foam Density for Heel in kg/m3 NA (if mattress not provided) * Therapeutic Weight limit for mattress in NA (if mattress not provided) 150
Required175
RequiredNA (if mattress not provided) 4/8 kg Operating temperature & humidity for ICU bed 10 -40 Deg C and relative humidity of 15-90% * Power Supply ( as appropriate fitted with Indian plug) Single phase 230 Volt
Required50 Hz ( AC Supply ) Single phase 230 Volt
Required50 Hz ( AC Supply )
RequiredN/A for mechanical operated Facility of Resettable overcurrent breaker shall be fitted for protection Yes Yes
RequiredN/A for handle operated ICU Bed frame and top must be Rust Proof Yes * Type of powder/Paint coating done to ICU Bed frame
Requiredtop & side panel Epoxy Polyester Coating 50-60 microns * ICU Bed should be made up of high quality metal
Requiredpretreated with materials providing good finish
Requiredscratch resistant
Requiredbacteriostatic coating Yes * Process used for pre chemically treatment of metallic bed component Dip tank processes * Facility of easily cleaning/maintenance to ICU Bed Yes * Warranty in years 3 3 Product instruction manual shall be supplied Yes * Standard Tool Kit for maintananace and Trouble Shooting to be provided with ICU bed Yes * Demonstration of working to be provided after completing supplies before Acceptance Yes * Dimensional & Material Parameter Material for the frame of bed MS MS
RequiredSS
RequiredAl-alloy
RequiredPolymer Material for side railling/Side Safety ABS Plastic MS
RequiredSS
RequiredAl-alloy
RequiredABS Plastic 5/8 guard Material for Head & Foot Panel/Board ABS Plastic MS
RequiredSS
RequiredAl-alloy
RequiredABS Plastic Material for Bed top Section ABS Plastic MS
RequiredSS
RequiredABS Plastic Material of wheels Polyester Polyester
RequiredMS
RequiredSS Material for IV rod with chromium plated SS SS
RequiredMS
RequiredAl-alloy Maximum Adjustable Back Rest Angle in Degree 0-70 0-70 Maximum Adjustable Knee Rest Angle in Degree 0-40 0-40 Diameter of Castor Roller in mm 130-150 * Maximum Trendlenburg Angle in Degree with tolerance ±2 degree 15 10
Required15
Required20 Maximum Reverse Trendlenburg Angle in Degree with tolerance ± 2 degree 15 10
Required15
Required20 Bed height adjustibility range in mm 500-900 * Mean coil diameter of tension spring used in counter weight mechanism in mm 40 40
RequiredN/A for Super Smooth Crank Screw Mechanism & Hyraulic mechanism for height Spring coil diameter used in counter weight mechanism in mm 6 6
RequiredN/A for Super Smooth Crank Screw Mechanism & Hyraulic mechanism for height Clearance between Bed Base frame and Floor surface in mm 150 120
Required150 Length of bed in mm with 2% tolerance 2100-2200 2100-2200 Width of bed in mm with 2% tolerance 1000-1050 1000-1050 Weight of ICU Bed in Kg 120 * Additional Parameters Spares ICU Bed Mainframe supplied Not supplied 1
Required2
RequiredNot supplied Spares Pair of Bed Ends
Requireddetachable Not supplied 1
Required2
RequiredNot supplied 6/8 supplied Spares Collapsible side rails supplied Not supplied 1
Required2
RequiredNot supplied Spares IV Rods supplied Not Supplied 1
Required2
RequiredNot Supplied Spares Matress simmilar to one supplied with ICU bed not supplied 1
Required2
Requirednot supplied Reports Certifications for Product European CE European CE Electric Shock Protection level- Class-B/class-1 Yes Yes
RequiredNA for handle operated Availability of ISO certification with manufacturer Yes * ISO certification Number and Date if ISO certificate not availiable then put NA - * Copies of test Reports/certificates and other certifications to be furnished to buyer on demand at time of supplies Yes * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.