Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC S 170 B 192 VILLAGE JHARERA DELHI SOUTH WEST DELHI DELHI 110010 | NEW DELHI | DELHI | 110010 | ₹26.4 L Quoted ₹26.7 L | L1 | Accepted-AOC contract was awarded to lowest bidder |
| 2 | L2₹28.0 L+₹1.3 L (4.82%)Rejected-Finance | ₹28.0 L+₹1.3 L (4.82%) | L2 | Rejected-Finance not become lowest bidder |
| 3 | L3₹28.1 L+₹1.4 L (5.24%)Rejected-Finance | ₹28.1 L+₹1.4 L (5.24%) | L3 | Rejected-Finance not become lowest bidder |
| 4 | L4₹28.5 L+₹1.8 L (6.66%)Rejected-Finance | ₹28.5 L+₹1.8 L (6.66%) | L4 | Rejected-Finance not become lowest bidder |
| 5 | L5₹28.7 L+₹2.0 L (7.35%)Rejected-Finance | ₹28.7 L+₹2.0 L (7.35%) | L5 | Rejected-Finance not become lowest bidder |
Tender Value
₹34.9 L
EMD Value
₹69,700
Closing Date
16 May 2024, 6:00 pmClosed
Major Sunny Kumar Attri
Garrison Engineer Jhansi
REPAIR/MAINT TO CEILING FANS, EXHAUST FANS, WALL MOUNTING FANS, AIR CIRCULATOR FAN UNDER AGE E/M AT GE JHANSI
2024_MES_650512_1
GE/JHA/TOK/04 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Jhansi
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
Yes
GE Jhansi
₹69,700
Yes
10 Jul 2024
19 Apr 2024
18 May 2024
19 Apr 2024
16 May 2024
3 May 2024
19 Apr 2024 - 2 May 2024
Amount
Taking down ceiling fan of any sweep, removing blade, checking its servicability for reuse, cleaning the fan completely of dust and dirt, greasing and cleaning blades and fan with kerosene oil and checking of aligment of shaft ,oiling and Re- hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc including replacement of old unserviceable fan hook, rubber reel, nut bolts, lock pin and washers etc, complete all as specified and directed by Engr-in-Charge. Note: (a) The fan shalll be checked for its servicability and if rewinding of ceiling fan is required then it shall not be carried out and u/s ceiling fan shall be deposited to MES store yard of AGE E/M Jhansi for further disposal. Decision of AGE E/M for servicablity of fan shall be final and binding. The checking of fan shall be carried out in presence of AGE E/M or JE E/M at AGE E/M yard of MES. (b) Replacement of defective parts i.e. Ball bearing, capacitor, fan hook, rubber reel, nut bolts, lock pin and washers etc shall be measured and paid separately. (c) Painting of serviceable fans shall be measured and paid seperately.
Taking down carefully the Exhaust fans/wall mounted fans /Air circulating fans of any capacity/sweep after disconnecting the eletric supply from any site and opening fans for repairs/over hauling including removing dust and greasing and cleaning blades and fan with kerosene oil and checking of aligment of shaft , oiling including re-assembling ,nut bolt checking and connecting/refixing of fans in its original position burnt out fan shall be kept seperately for rewinding complete all as specified and directed. Note: Rewinding and replacment of defective parts shall be measured and paid separately.
Material and labour for Rewinding of exhaust fan of size up to 250/300mm with suitable gauge copper winding wire (super enamelled) including all insulating material after necessary heat varnishing testing etc. complete all as specified and directed.
All as per Ser item No 03 above but exhaust fan of size up to 380/450mm complete all as specified and directed.
All as per Ser item No 03 above but wall mounted fan of size up to 300 mm sweep complete all as specified and directed.
All as per Ser item No 03 above but wall mounted fan of size up to 450 mm sweep complete all as specified and directed.
All as per Ser item No 03 above but industrial air circulator fan of size up to 600mm sweep complete all as specified and directed.
Note for item No 02 to 07. (a) Repairing /rewinding of Exhaust fans/Aircirculating fans shall be carried out in AGE E/M yard Jhansi in presence of JE E/M. (b) Contractor shall detail the staff to collect defective fans from concerned JE E/M , check the fan after opening it, and intimate the defects in the fan to JE E/M before carrying out the repairs. (c) The bearing of fan should be of NBC/SKF/TATA make only. No other make will be accepted. (d) Contractor will be provided by sticker of each repairing fan with date and name of firm. (e) Contractor shall establish workshop with proper equipments and skilled staff for repairs/winding work, rent and allied charges will be applied as per tender norms.
M & L for painting of Ceiling fan of any sweep complete, in situ with synthetic enamel paint by spraying including filling cavties with one coat of filler after cleaning all dust including MES Nos are entered in all ceiling in site only, complete all as specified and directed.
Replacement of following accessories from ceiling fans taken down vide item No 01.00 here in before complete all as specified and directed.
Ball Bearing No 6201
Ball Bearing No 6202
Ball Bearing No 6203
Rubber Bush, nut, bolts, washer and split pin etc as required at site suitable for ceiling fan.
Condensor 2.5 mfd
Condensor 4 mfd
Ceiling fan shaft
Supply and fixing in repair metal fan blade of any type and any size suitable for 1200 mm/ 1400 mm Ceiling fan complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair metal fan blade of any type and any size suitable for Exhuast fan of any capacity, of any make, complete all as specified and directed.
Supply and fix in replacement of standard GI fan clamp with rubber bush, bolts, nuts, spring washers & split pins etc complete all as specified and directed.
Supply and fix in replacement of Fan down rod of suitable size up to 600mm to 1000mm long as per site requirement, having suitable holes on top and bottom of rod for inserting bolts and for drawing wires etc complete all as specified and directed by Engineer-in-Charge.
All as per ser item No. 13.00 here-in-before but of size above one meter and up to two meters long.
Supply and fix of PVC insulated and PVC sheathed 3 core x 0.75 sqmm stranded copper conductor cable conforming to IS:694 complete all as specified and directed by Engineer-in-Charge.
All as per ser item No. 15.00 here-in-before but of size 3 core x 1.5 sqmm.
Supply and fix in replacement of front and rear grill complete set incl suitable nuts & bolts as per existing of exhaust fan 300/450mm sweep all as specified and directed.
Supply and fix in replacement of front grill suitable of wall mounted fan 300/450mm sweep complete all as specified and directed.
Supply and fix in replacement of fan blade of metallic body suitable of wall mount fan 300/450mm sweep complete all as specified and directed.
Supply and fix of ventilating fan with plastic body with louvers, 250mm sweep, single phase, 230 volts, 50 Hz. Complete all as specified and directed.
Supply and fixing in replacement exhaust fan, steel body AC single Phase, 230 V of size 450 mm sweep heavy duty with blades, frames and louvers including taking down existing unserviceable exhuast fan of any description complete all as specified and directed. Note :- Old and u/s exhaust fan deposited to E/M yard store as a govt property.
Supply and fix in replacement of exhaust fan with steel body 300mm sweep with blade , frame and louvers , single phase, 230 volts, 50 Hz. including taking down existing unserviceable exhuast fan of any description complete all as specified and directed. Note :- Old and u/s exhaust fan deposited to E/M yard store as a govt property.
Supply and fix wall mounted fan, 300 mm sweep, 2150 RPM Air delivery 90 CFM, three blade, Adjustable upward and downward, with tilt mechanism, motor proection with thermal overload protection and auto-resetting, 230V complete all as specified and directed by Engineer-in-Charge.
Supply and fix wall mounted fan, 400 mm sweep, 1350 RPM . Air delivery 65 CMM, three blade, Adjustable upward and downward tilt mechanism, motor proection with thermal overload protection and auto-resetting, 230V complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep 3 blade, white colour,. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated, copper winding with brushless direct current motor (BLDC)(with remote) and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable from ceiling rose all as specified and directed by Engr-in-Charge. Note : Make of fan shall be one of the make mentioned in List of Makes and model No. of Fan shall be got approved from GE in writing, Contractor shall supply technical litrature of Fan and model comprising of all requirements mentioned in description which he intend to use in the work, without approval of GE contractor shall not place order of Fan.
Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1400 mm sweep 3 blade, white colour,. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated, copper winding with brushless direct current motor (BLDC)(with remote) and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable from ceiling rose all as specified and directed by Engr-in-Charge. Note : Make of fan shall be one of the make mentioned in List of Makes and model No. of Fan shall be got approved from GE in writing, Contractor shall supply technical litrature of Fan and model comprising of all requirements mentioned in description which he intend to use in the work, without approval of GE contractor shall not place order of Fan.
Supply and fix in replacement of exhaust fan with steel body 380mm sweep with blade , frame and louvers , single phase, 230 volts, 50 Hz. including taking down existing unserviceable exhuast fan of any description complete all as specified and directed. Note :- Old and u/s exhaust fan deposited to E/M yard store as a govt property.
Soni Traders
AGRASEN ENTERPRISES
M/s Ratan Mechanical Works
JAI BALAJI CONSTRUCTIONS
M/S SHARADA ASOCIATE
PRAGATI ELECTRICALS AND ELECTRONICS
FTH Traders
ADARSH ENTERPRISES
HARNAM SINGH ANIL SINGH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .